Omron-Electronics-G4A-1A-E-DC5
| Part # | Omron-Electronics-G4A-1A-E-DC5 |
| Download | Omron-Electronics-G4A-1A-E-DC5 |
G4A
PCB Power Relay
Miniature Single-pole Relay with
80A Surge Current and 20A
Switching Current
• Capable of Switching Motor Load of 80-A Surge Current and 20A
Switching/Cut-off Current
• Miniature, relay with high switching power and long endurance.
• Creepage distance conforms to UL and CSA standards.
• Highly noise-resistive insulation materials employed.
• Standard model available with flux protection construction.
RoHS Compliant
■
Model Number Legend
G4A-
@
@
–
@
–
@
■
Application Examples
• Air
conditioner
— —
—
—
1 2
3
4
1. Number
of Poles
3. Terminal
Shape
Non
e
:
#
250 quick-connect/
PCB coil terminals
4. Special
Function
E: For long endurance
1: 1-pole
G
4
A
2. Contact
Form
A: SPS
T
–
NO (1a)
P
: PCB terminals/
PCB coil terminals
■
Ordering Information
■
Characteristics
●
Quick-connect/PCB coil terminals
Contact resistance *1
Operate time
Release time
Max.
100 m
Ω
max.
20 ms max.
10 ms max.
Minimum
Contact form
Load Contact
T
e
rminal
Coil terminal
Model
Rated voltage
12, 24 VDC
packing unit
SPS
T
–
NO
(1a)
#250 quick-connect
terminals
PCB terminals
G4A-1A-E
50 pcs/tray
operating
frequency
Mechanical
18,000 operations/hr
●
PCB terminals
Insulation resistance *2
1,000 M
Ω
min.
4,500 VAC 50/60 Hz for
1 min
Minimum
packing unit
Between coil
and contacts
Contact form
Load Contact
T
e
rminal
Coil terminal
SPS
T
–
NO
Model
Rated voltage
12, 24 VDC
Dielectric
strength
PCB terminals
PCB terminals
G4A-1A-PE
50 pcs/tray
Between
contacts of
the same
polarity
(1a)
1,000 VAC 50/60 Hz for
1 min
Note. When ordering, add the rated coil voltage to the model number.
Example: G4A-1A-E DC12
Impulse
withstand
voltage
Rated coil voltage
Between coil
and contacts
8.5 kV (1.2 x 50
μ
s)
However, the notation of the coil voltage on the product case as well as on the packing will be marked
as
@@
VDC.
Insulation Between
coil
Clearance: 3.2 mm,
distance
and contacts
Creepage: 6.4 mm
10 to 55 to 10 Hz,
Destruction
Malfunction
■
Ratings
0.75 mm single amplitude
(1.5 mm double amplitude)
Vibration
resistance
●
Coil
10 to 55 to 10 Hz,
Item
Must operate voltage
Must release voltage
Max. permissible voltage
Rated
current
(mA)
Coil
0.75 mm single amplitude
Power consumption
(W)
(V)
(V)
(V)
resistance
(1.5 mm double amplitude)
Rated voltage
(
Ω
)
% of rated voltage
Destruction
Malfunction
1,000 m/s
2
200 m/s
2
2,000,000 operations min.
(at 18,000 operations/hr)
100,000 operations min.
(ON/OFF: 1 s)
200,000 operations min.
(ON/OFF: 1.5 s)
Shock
resistance
12 VDC
24 VDC
75
37.5
160
640
160%
(at 23°C)
70% max.
10% min.
0.9
Mechanical
Note 1. The rated current and coil resistance are
●
Motor Ratings
measured at a coil temperature of 23
with a tolerance of
10%.
°
C
Resistive
load
Switching
frequency
Electrical
durability
Load conditions
Durability
2. The inductances shown above are
reference values.
3. Operating characteristics are measured at
a coil temperature of 23 C.
4. Max. permissible voltage refers to the
maximum value in a varying range of
operating power voltage, not a continuous
voltage.
Motor load
250 VAC:
Inrush current: 80 A,
ON: 1.5 s
OFF: 1.5 s
200,000
operations
30,000 operations min.
(ON: 3 s, OFF: 5 s)
°
0.3 s (cos
φ
= 0.7)
Inverter load
Break current: 20 A
(cos =
0.9)
Failure rate (P level)
(reference value *3)
Ambient operating
temperature
Ambient operating humidity
5% to 85%
Weight Approx.
23 g
φ
100 mA at 5 VDC
●
Inverter Ratings
-20°C to 60°C (with no icing
or condensation)
Switching
frequency
Electrical
durability
●
Contacts
Load conditions
Load
100 VAC:
Resistive load
Single
Ag-Alloy (Cd free)
20 A at 250 VAC
20 A
Inrush current:
200 A (0.P)
ON: 3 s
OFF: 5 s
30,000
operations
Note. The data given above are initial values.
*1. Measurement
conditions: 5 VDC, 1 A, voltage
drop method.
*2. Measurement
conditions: The insulation
resistance was measured with a 500 VDC
megohmmeter at the same locations as the
dielectric strength was measured.
*3. This
value was measured at a switching
frequency of 120 operations/min.
Item
Break current: 20 A
Contact type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
●
Overload Durability (Reference Value)
Switching
frequency
Electrical
durability
Load conditions
250 VAC
20 A
250 VAC:
Inrush current: 80 A
Break current: 80 A
ON: 1.5 s
OFF: 99 s
1,500
operations
(cos
φ
= 0.7)
1
G4A
PCB Power Relay
■
Engineering Data
●
Maximum Switching Capacity
G4A-1A-(P)E
●
Durability
G4A-1A-(P)E
●
Ambient Temperature vs.
Maximum Coil Voltage
G4A-1A-(P)E
100
70
100
90
180
50
160
80
70
60
50
40
30
20
10
30
AC load
140
120
100
250 VAC resistive load
10
7
5
3
1
80
0
1
3
5
10
30 50
100
300 50
0
1
,000
0
5
10
15
20
25
-25
0
10
20
30
40
50
60
70 80
Switching voltage (V)
Switching current (A)
Ambient temperature (°C)
Note. The maximum coil voltage is the maximum
voltage that can be applied to the relay coil.
●
Ambient Temperature vs. Must
Operate and Must Release
V
o
ltages
G4A-1A-(P)E
●
Shock Malfunction
G4A-1A-(P)E
Number of Relays: 5 pcs
Y
100
1,000
Must Operating voltage
Must Recovery voltage
Sample:
G4A-1A-E DC12V
Number of Relays: 5 pcs
800
1,000
X
1,000
Z’
80
60
40
20
600
400
200
G
4
A
Test conditions
:
S
hock is applied in ±±, ±ꢀ, ±ꢁ
directions three times each with
and without energizing the Relays
to check the number of
malfunctions.
Requirement: 200
m/s
2
200
400
600
Shock direction
Z
X’
X
1,000
1,000
X’
800
Y
Z
contact A
1,000
Unit: m/s
2
Y’
Z’
Y’
0
-60
-40
-20
0
20
40
60
80 100
Ambient temperature (°C)
■
Dimensions
Mounting Holes
30.ꢀ max.
(30.1)*
#250 quick-connect/PCB coil terminals
G4A-1A-E
(Bottom View)
Four, 1.8
+
0.1
dia.
0
16 max.
(1ꢀ.7)*
0.1
6.2ꢀ
0.1
ꢀ.7ꢀ
0.0ꢀ
0.8
0.8
6.3ꢀ
12
0.1
22
8
0.1
27.6
Terminal Arrangement/Internal Connections
3.4
(Top View) (Bottom View)
2
23.ꢀ max.
(23.3)*
4
3
3
1
2
1
0.3
1.ꢀ
1.ꢀ
0.8
4
3.ꢀ
* Average value
Tab Terminal
PCB Terminal
(No coil polarity)
PCB Mounting Holes
30.5 max.
(30.1)*
Straight PCB/PCB coil terminals
G4A-1A-PE
(Bottom View)
Four, 1.8
+
0.1
dia.
0
16 max.
(15.7)*
9.4
0.1
0.1
6.25
5.75
0.05
12
0.1
22
0.1
27.6
Terminal Arrangement/
Internal Connections
(Bottom View)
26.8 max.
(26.5)*
23.3
4
3
1
2
1
0.3
1.5
1.5
3.5
0.8
* Average value
(No coil polarity)
2
G4A
PCB Power Relay
■
Approved Standards
●
The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in
this datasheet.
UL Recognized
(File No. E41643)
CSA Certified
(File No. LR31928)
Number of
poles
Number of test
operations
Number of
poles
Number of test
operations
Model
Coil ratings
Contact ratings
Model
Coil ratings
Contact ratings
20 A, 250 VAC (Resistive)
40°C
20 A, 250 VAC (Resistive)
40°C
100,000
10,000
15 A, 30 VDC (Resistive)
40°C
15 A, 30 VDC (Resistive)
40°C
G4A-1A-E
G4A-1A-PE
SPS
T
–
NO
(1a)
G4A-1A-E
G4A-1A-PE
SPS
T
–
NO
(1a)
12 to 24 VDC
12 to 24 VDC
23 A, 277 VAC (General
Purpose) 40°C
23 A, 277 VAC (General
Purpose) 40°C
30,000
25,000
30,000
25,000
TV-15 120 V AC 40°C
TV-15 120 V AC 40°C
EN/IEC, VDE Certified
(Certificate No. 107293)
Number of
poles
SPS
T
–
NO
(1a)
Number of test
operations
Model
Coil ratings
12, 24 VDC
Contact ratings
G4A-1A-E
G4A-1A-PE
20 A, 250 VAC (cos
φ
=1.0)
100,000
50°C
■
Precautions
●
Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
G
4
A
●
Mounting
●
Terminals
●
Other Precautions
• When
mounting more than two Relays
side by side, keep a 3 mm gap
horizontally and vertically between
Relays to ensure a good heat
dissipation. It may cause a malfunction
if heat is not dissipated smoothly from
the Rela
y
.
• The
terminals fit FASTON receptacle
250 and are suitable for positive-lock
mounting. Use only Faston terminals
with the specified numbers.
• This
Relay is suitable for power load
switching of air-conditioning
compressors and power supplies, etc.
Do not use the G4A to switch micro
loads less than 100 mA, such as in
signal applications.
Select leads for connecting Faston
receptacles with wire diameters that
are within the allowable range for the
load current.
Do not apply excessive force to the
terminals when mounting or
dismounting the Faston receptacle.
Insert and remove terminals carefully
one at a time. Do not insert terminals
at an angle, or insert/remove multiple
terminals at the same time.
Refer to the following table for
recommendations of connectors made
by OMRON.
Receptacle
terminals
T
y
pe
Housing
±T3W-S441-12
±T3W-S442-12
±T3W-S443-12
±T3B-1S white
#250 terminals
(width: 6.35 mm)
3
G4A
PCB Power Relay
G
4
A
•
Application examples pro
v
ided in this doc
u
ment are for reference only. In act
u
al applications, confirm e
qu
ipment f
u
nctions and safety
b
efore
u
sing the prod
u
ct.
•
Cons
u
lt yo
u
r OMRO
N
representati
v
e
b
efore
u
sing the prod
u
ct
u
nder conditions
w
hich are not descri
b
ed in the man
u
al or applying the prod
u
ct to n
u
clear control systems, railroad
systems, a
v
iation systems,
v
ehicles, com
bu
stion systems, medical e
qu
ipment, am
u
sement machines, safety e
qu
ipment, and other systems or e
qu
ipment that may ha
v
e a serio
u
s
infl
u
ence on li
v
es and property if
u
sed improperly. Make s
u
re that the ratings and performance characteristics of the prod
u
ct pro
v
ide a margin of safety for the system or
e
qu
ipment, and
b
e s
u
re to pro
v
ide the system or e
qu
ipment
w
ith do
ub
le safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Cat. No. J056-E1-09
1116(0207)(O)
4