Aimtec-AMFE305150-LN22-STD-28
| Part # | Aimtec-AMFE305150-LN22-STD-28 |
| Download | Aimtec-AMFE305150-LN22-STD-28 |
AMFE305150
AMFE305150
Aimtec’s AMFE305
150 series is designed to offer protection against AC
power surges. These filters can assist the AC-DC converters in meeting
the Surge level of IEC/EN61000-4-5 standard ±2
KV (2Ω internal
resistance) or ±4
KV (12Ω internal resistance) and EMI requirement of
CISPR32/EN55032 Class B standard.
With a wide input voltage range of 85-305 VAC in a compact package
these filter modules are best suited for AC-DC application that are
sensitive to noise interference.
Encapsulated
Features
Summary
•
•
•
•
Universal Input: 85 – 305VAC
AMFE305150
Operating Temp: -40 °C to +85 °C
High isolation voltage: 2000VAC
Surge Suppression Ability: L-N:up to ±4KV, L-G:
up to ±6KV
305
5
Passive
3
85
•
•
Attenuation Ability: Up to 30dB@150k~1GHz
EMI meet EN55032 Class B
Active
85
0.5
-40
Input voltage
(VAC)
Type
Max output current
(A)
Temp. range
(
℃
)
Applications
Training
Coming Soon!
Industrial
Instrumentation
Power Grid
Telecom
Application Notes
Product Training Video
(click to open)
F 052e R4
REV: 12/20/A
1
AMFE305150
Models & Specifications
Models
Input Voltage
Max Current
Surge Level
(IEC/EN61000-4-5, GB/T17626.5)
Model
(VAC)
(A)
L-N: ±2KV (
2Ω internal)
L-GND: ±4KV (
12Ω internal)
L-
N: ±4KV (2Ω
internal)
L-
GND: ±6KV (12Ω internal)
AMFE305150-LN22
AMFE305150-LN42
85 – 305
1.5
85 – 305
1.5
Note: Use suffix
“ST”
for chassis and suffix
“STD”
for DIN-Rail mounting (ex. AMFE305150-LN22-ST is chassis mounting and AMFE305150-LN22-STD
is DIN-Rail mounting version).
Output Specifications
Parameters
Tested Conditions
Typical
Maximum
Units
KV
Suppressed Output Peak Voltage
(AMFE305150-LN22)
Suppressed Output Peak Voltage
(AMFE305150-LN42)
Input surge voltage L-N: 2KV
Input surge voltage L-GND: 4KV
Input surge voltage L-N: 4KV
Input surge voltage L-GND: 6KV
1.13
3.18
3.16
5.06
KV
Frequency Attenuation Specifications
Parameters
Tested Conditions
Typical
Maximum
Maximum
Units
150KHz ~ 1GHz, AMFE305150-LN22
150KHz ~ 1GHz, AMFE305150-LN42
20
30
dB
dB
The attenuation coefficient of
frequency
General Specifications
Parameters
Conditions
Typical
Units
Operating temperature
Storage temperature
-40 to +85
-55 to +125
°C
°C
220VAC / 0.5A
220VAC / 1.0A
220VAC / 1.5A
5
20
30
°C
°C
°C
Case temperature rise
Isolation Voltage (L/PE; N/PE)
Case material
1 min,5mA leakage current
2000
VAC
Heat resistant black Plastic (flammability to UL 94V-0)
PCB mountable models
20
40
60
45
65
85
Weight
(AMFE305150-LN22)
With optional -ST mounting plate
With optional -STD mounting plate
PCB mountable models
With optional -ST mounting plate
With optional -STD mounting plate
PCB mountable models
With optional -ST mounting plate
With optional -STD mounting plate
PCB mountable models
g
g
Weight
(AMFE305150-LN42)
1.33 x 0.87 x 0.71 inches (33.70 x 22.20 x 18.00mm)
2.99 x 1.24 x 1.06 inches (76.00 x 31.50 x 26.80mm)
2.99 x 1.24 x 1.24 inches (76.00 x 31.50 x 31.40mm)
2.12 x 1.13 x 0.75 inches (53.80 x 28.80 x 19.00mm)
Dimensions (L x W x H)
(AMFE305150-LN22)
Dimensions (L x W x H)
F 052e R4
REV: 12/20/A
2
AMFE305150
(AMFE305150-LN42)
With optional -ST mounting plate
With optional -STD mounting plate
2.99 x 1.24 x 1.09 inches (76.00 x 31.50 x 27.80mm)
2.99 x 1.24 x 1.28 inches (76.00 x 31.50 x 32.40mm)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated
output load unless otherwise specified.
Safety Specifications
Parameters
Put AMFE305150-LN22 on to the input of AC/DC module can ensure the module meet Surge level of
IEC/EN61000-4-5 standard ±2KV
(2Ω internal resistance)
/ ±4KV
(12Ω internal resistance).
Standards
Put AMFE305150-LN42 on to the input of AC/DC module can ensure the module meet Surge level of
IEC/EN61000-4-5 standard ±4KV
(2Ω internal resistance)
/ ±6KV
(12Ω internal resistance)
and EMI requirement of
CISPR32/EN55032 Class B.
Dimensions
AMFE305150-LN22
3
3
.70
(1.33)
2
8
.00
(1.10)
Pin Output Specifications
1
2
3
3
4
5
Pin
1
Single
GND
5
4
Bottom View
2
1
2
3
4
5
-V Input
+V Input
+V Output
-V Output
Ø1.10
(Ø0.04)
Dimensions mm (inch).
Pin diameter tolerance ±0.1 (±0.004)
Pin height tolerance ±0.5 (±0.02)
Front View
0.60
(0.02)
AMFE305150-LN42
5
3
.80
(2.12)
4
5
.72
(1.80)
Pin Output Specifications
Pin
1
Single
GND
1
3
4
2
3
4
5
-V Input
+V Input
+V Output
-V Output
2
3
5
4
Bottom View
2
1
5
Ø1.50
(Ø0.06)
Dimensions mm (inch).
Pin diameter tolerance ±0.1 (±0.004)
Pin height tolerance ±0.5 (±0.02)
Front View
1.00
(0.04)
F 052e R4
REV: 12/20/A
3
AMFE305150
Dimensions with ST Optional
AMFE305150-LN22-ST
Pin Output Specifications
76.00
(2.99)
Pin
1
Single
GND
61.60
(2.43)
Ø3.30
2
3
4
5
-V Input
+V Input
+V Output
-V Output
1
5
4
2
Top View
3
Ø3.30
(0.13)
Front Vi
e
w
Dimensions mm (inch)
Wire range: 24-12 AWG
General tolerances ±0.50 (±0.02)
AMFE305150-LN42-ST
76.00
(2.99)
Pin Output Specifications
Pin
1
Single
GND
61.60
(2.43)
Ø3.30
2
3
4
5
-V Input
+V Input
+V Output
-V Output
1
5
2
Top View
4
3
Ø3.30
(Ø0.13)
Front Vi
e
w
Dimensions mm (inch)
Wire range: 24-12 AWG
General tolerances ±0.50 (±0.02)
F 052e R4
REV: 12/20/A
4
AMFE305150
Dimensions with STD Optional
AMFE305150-LN22-STD
76.00
(2.99)
Pin Output Specifications
Pin
1
Single
GND
61.60
(2.43)
2
3
4
5
-V Input
+V Input
+V Output
-V Output
1
2
5
4
Top View
3
Front Vi
e
w
Dimensions mm (inch)
Wire range: 24-12 AWG
General tolerances: ±0.50 (±0.02)
AMFE305150-LN42-STD
76.00
(2.99)
Pin Output Specifications
Pin
1
Single
GND
61.60
(2.43)
2
3
4
5
-V Input
+V Input
+V Output
-V Output
1
2
5
4
Top View
3
Front Vi
e
w
Dimensions mm (inch)
Wire range: 24-12 AWG
General tolerances: ±0.50 (±0.02)
F 052e R4
REV: 12/20/A
5
AMFE305150
Application Circuit
Fuse
Input (L)
+V output
-V output
Input (L)
Output (L)
AC EMC Filter
AC-DC Converter
Output (N)
Input (N)
Input (N)
GND
GND
Model
Recommended external circuit parameters
The fuse value varies with different power modules and must be selected in accordance with the
specified input current of the corresponding power converter, but not exceeding the filter specifications.
Fuse
F 052e R4
REV: 12/20/A
6
AMFE305150
Frequency Attenuation
AMFE305150-LN22 common mode
80
70
60
50
40
30
20
10
0
1
2
-10
10K
100K
1M
10M
100M
Hz (10K-200M)
1: 17.54MHz/58.81dB
2: 29.51MHz/32.14dB
AMFE305150-LN22 differential mode
80
70
60
50
40
30
20
10
0
1
2
3
-10
10K
100K
1M
10M
100M
Hz (10K-200M)
1: 5.02MHz/51.14dB
2: 19.82MHz/51.09dB
3: 29.98MHz/28.69dB
F 052e R4
REV: 12/20/A
7
AMFE305150
AMFE305150-LN42 common mode
80
70
60
50
40
30
20
10
0
1 2
3
-10
10K
100K
1M
10M
100M
Hz (10K-200M)
1: 20.02MHz/54.16dB
2: 23.53MHz/31.92dB
3: 26.83MHz/41.51dB
AMFE305150-LN42 differential mode
80
1
2
3
70
60
50
40
30
20
10
0
-10
10K
100K
1M
10M
100M
Hz (10K-200M)
1: 2.28MHz/74.15dB
2: 4.77MHz/68.62dB
3: 20.84MHz/48.06dB
F 052e R4
REV: 12/20/A
8
AMFE305150
Supporting the power module product model
EMI
EMI
(With
EMC
Surge
(With
AMFE305150-
Surge
(With
AMFE305150-
EFT
(Without
External Circuit)
EFT
(With EMC
filter)
Surge
(Without External
Circuit)
(Without
Model
External
Circuit)
CISPR32/
EN55032
Class B
filter)
LN22)
LN42)
AME1-JZ
AME2-JZ
IEC/EN61000-4-4
± 2KV
IEC/EN61000-4-5
± 1KV / ± 2KV
CISPR32/
EN55032
Class A
CISPR32/
EN55032
Class A
CISPR32/
EN55032
Class B
CISPR32/E
N55032
Class B
CISPR32/E
N55032
Class B
IEC/EN61000-4-4
± 2KV
IEC/EN61000-4-5
± 1KV / ± 2KV
AME3-CJZ
AMEL5-CJZ
AMEL5-JZ
IEC/EN61000-4-4
± 2KV
IEC/EN61000-4-4
± 4KV
IEC/EN61000-4-5
± 1KV / ± 2KV
IEC/EN61000-4-4
± 2KV / ± 4KV
IEC/EN61000-4-4
± 2KV
IEC/EN61000-4-4
± 4KV
IEC/EN61000-4-5
± 1KV
IEC/EN61000-4-4
± 2KV / ± 4KV
CISPR32/
EN55032
Class A
CISPR32/E
N55032
Class B
AMEL10-
MJZ
IEC/EN61000-4-4
± 2KV
IEC/EN61000-4-4
± 4KV
IEC/EN61000-4-5
± 1KV
IEC/EN61000-4-4
± 2KV / ± 4KV
CISPR32/
EN55032
Class B
AMEL12-CJZ
AMEL20-CJZ
IEC/EN61000-4-4
± 4KV
IEC/EN61000-4-5
± 2KV
IEC/EN61000-4-4
± 4KV / ± 6KV
AME5-CJZ
AME5-JZ
AME10-CJZ
AME10-JZ
AME15-CJZ
AME15-JZ
AME15-MJZ
AME20-CJZ
AME20-JZ
AME25-CJZ
AME25-JZ
AME25-MJZ
AME40-CJZ
AME40-MJZ
AME60-MJZ
CISPR32/
EN55032
Class B
IEC/EN61000-4-4
± 2KV
IEC/EN61000-4-4
± 4KV
IEC/EN61000-4-5
± 1KV / ± 2KV
IEC/EN61000-4-4
± 2KV / ± 4KV
NOTE: 1.
Datasheets are updated as needed and as such, specifications are subject to change without notice.
Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to
www.aimtec.com for the most current product specifications.
2.
Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured.
3.
Mechanical
drawings and specifications are for reference only.
4.
All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless
otherwise specified.
5.
Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time
o
f publishing this document. CAS numbers and
other limited information are considered proprietary and may not be available for release.
6.
This product is not designed for use in critical life support systems, equipment used in hazardous
environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet.
7.
Warranty is in accordance with
F 052e R4
REV: 12/20/A
9