Astrodyne-TDI-082M-00101-00
| Part # | Astrodyne-TDI-082M-00101-00 |
| Download | Astrodyne-TDI-082M-00101-00 |
082(M)
FILTERED POWER ENTRY MODULES WITH FUSE HOLDER AND SWITCH
(GENERAL PURPOSE & MEDICAL)
FEATURES
Ĺ
ꢀ
Rated currents
include
1A, 3A, 6A,
and 10A
Ĺ
ꢀ
Single Stage
Ĺ
ꢀ
Available with quick disconnect tabs and
wire leads options
Ĺ
ꢀ
General Purpose & Low Leakage (M)edical
options
Ĺ
ꢀ
Compact IEC inlet power entry module
Ĺ
ꢀ
Integrated safety fuse and DPST on/off switch
Ĺ
ꢀ
Easy to install and use
Ĺ
ꢀ
Agency Approvals UL and EN 60939,
CSA C22.2
Ĺ
ꢀ
Y-cap value can be adjusted
SPECIFICATIONS
OPERATING FREQUENCY
IEC INLET
ꢀ
MAX. OPERATING VO
L
TAGE
ꢀ
ꢀ
ꢀ
50/60Hz
C14
250VAC +10%
25/85/21
0.25”
T
ABS
W: WIRE LEADS
ꢀ
ELECTRICAL SCHEMATIC
082
CLIMATIC CATEGORY
TERMINALS (-T)
ꢀ
ꢀ
ꢀ
ꢀ
TY
P
.
W
EIGHT, LBS (KG)
ꢀ
ꢀ
0.10 ꢀ0.04ꢁ
TYPICAL LEAKAGE CURRENT 082
082M
@ 250 VAC 50 Hz
ꢀ
@ 120 VAC 60 Hz
ꢀ ꢀ
ꢀ
ꢀ
0ꢀ-ꢀ0.42
mA Max.
0ꢀ-ꢀ0.23
mA Max.
TYPICAL LEAKAGE CURRENT 082M
ꢀ 250 VAC 50 Hz
ꢀ
ꢀ 120 VAC 60 Hz
ꢀ ꢀ
ꢀ
ꢀ
0ꢀꢁꢀ10uAꢀMax.
0ꢀꢁꢀ5uAꢀMax.
HOW TO ORDER
HIPOT RATINGS
082M.0ZZ01.00-RSI
LINE TO LINE
1450ꢀVDC
2250ꢀ VDC
LINE TO GROUND
ꢀ
ꢀ
ꢀ
BLANK = BLACK SWT, RSI = ILLUMINATED SWT
ZZ = RATED CURRENT
M=MEDICAL, BLANK = GENERAL PURPOSE
084= FILTER SERIES
TYPICAL APPLICATIONS
Householdꢀappliancesꢀandꢀequipment
Smallꢀmedicalꢀequipment
NOTE:
USE ANY COMBINATON OF
M
,
ZZ
AND
T
Portableꢀelectricalꢀandꢀelectronicꢀequipment
Testꢀandꢀmeasurement/labꢀequipment
Rackꢀmountedꢀequipment
E.G.
082.00101.00-RSI
(1A GENERAL PURPOSE VERSION WITH ILLUMINATED
SWITCH) |
082M.00601.00
(6A LOW LEAKAGE MEDICAL VERSION)
1
WWW.ASTRODYNETDI.COM
·
(908) 850-5088
SPECIFICATIONS ARE SUBJECT TO CHANGE
082(M)
FILTERED POWER ENTRY MODULES WITH FUSE HOLDER AND SWITCH
(GENERAL PURPOSE & MEDICAL)
TERMINAL OPTIONS
(QD) OUTPUT
APPLICATION PURPOSE
MAX. DIMENSIONS” (MM)
R
A
TED
MODEL NO.
CURREN
T
, A
@
4
0° C
GENERAL
MEDICAL
WIDTH
(LENGTH)
HEIGHT
082.00101.00
1
1
2.39’’(61)
2.39’’(61)
1.72’’(44)
1.72’’(44)
1.26’’(32)
1.26’’(32)
082.00101.00ꢁRSI
082.00301.00
082.00301.00ꢁRSI
082.00601.00
3
3
6
2.39’’(61)
2.39’’(61)
2.39’’(61)
1.72’’(44)
1.72’’(44)
1.72’’(44)
1.26’’(32)
1.26’’(32)
1.26’’(32)
082.00601.00ꢁRSI
082.01001.00
6
10
10
1
2.39’’(61)
2.39’’(61)
2.39’’(61)
2.39’’(61)
2.39’’(61)
2.39’’(61)
2.39’’(61)
2.39’’(61)
2.39’’(61)
2.39’’(61)
1.72’’(44)
1.72’’(44)
1.72’’(44)
1.72’’(44)
1.72’’(44)
1.72’’(44)
1.72’’(44)
1.72’’(44)
1.72’’(44)
1.72’’(44)
1.26’’(32)
1.26’’(32)
1.26’’(32)
1.26’’(32)
1.26’’(32)
1.26’’(32)
1.26’’(32)
1.26’’(32)
1.26’’(32)
1.26’’(32)
082.01001.00ꢁRSI
082M.00101.00
082M.00101.00ꢁRSI
082M.00301.00
1
3
082M.00301.00ꢁRSI
082M.00601.00
3
6
082M.00601.00ꢁRSI
082M.01001.00ꢁRSI
6
10
082(M) MECHANICAL OUTLINES (MM)
QD TABS
SERIES
(A)
B
C
D
E
F
G
H
U
S
T
R
r
1.72”
(44)
2.39”
(61)
1.26”
(32)
2.83”
(72)
2.40”
(61)
3.23”
(82)
0.35”
(9)
2.83”
(72)
2.40”
(61)
1.18”
(30)
0.10”
(3)
0.17”
(4)
QD TABS ꢀAꢁ ꢀ1-10Aꢁ
ꢀ
2*4.0
TYPICAL TOLERANCE: +/-0.02” (0.50MM)
SPECIFICATIONS ARE SUBJECT TO CHANGE
2
WWW.ASTRODYNETDI.COM
·
(908) 850-5088
082(M)
FILTERED POWER ENTRY MODULES WITH FUSE HOLDER AND SWITCH
(GENERAL PURPOSE & MEDICAL)
TYPICAL INSERTION LOSS, dB (50/50 Ohm)
082 INSERTION LOSS
Amps
Freq (MHz)
0.15
41.0
18.0
37.0
18.0
25.0
18.0
18.0
18.0
0.5
53.0
28.0
49.0
28.0
35.0
28.0
26.0
28.0
1
10
30
56.0
32.0
51.0
32.0
38.0
32.0
28.0
32.0
55.0
50.0
50.0
50.0
48.0
50.0
42.0
50.0
50.0
50.0
50.0
50.0
45.0
50.0
40.0
50.0
CMꢀ(dB)
DMꢀ(dB)
CMꢀ(dB)
DMꢀ(dB)
CMꢀ(dB)
DMꢀ(dB)
CMꢀ(dB)
DMꢀ(dB)
1
3
6
10
082M INSERTION LOSS
Amps
Freq (MHz)
0.15
41.0
18.0
37.0
18.0
25.0
18.0
18.0
18.0
0.5
49.0
28.0
45.0
28.0
31.0
28.0
24.0
28.0
1
10
30
17.0
50.0
15.0
50.0
15.0
50.0
8.0
51.0
32.0
43.0
32.0
33.0
32.0
26.0
32.0
27.0
50.0
23.0
50.0
23.0
50.0
10.0
50.0
CMꢀ(dB)
DMꢀ(dB)
CMꢀ(dB)
DMꢀ(dB)
CMꢀ(dB)
DMꢀ(dB)
CMꢀ(dB)
DMꢀ(dB)
1
3
6
10
50.0
3
WWW.ASTRODYNETDI.COM
·
(908) 850-5088
SPECIFICATIONS ARE SUBJECT TO CHANGE