Cosel-EAP-03-102
| Part # | Cosel-EAP-03-102 |
| Download | Cosel-EAP-03-102 |
Ordering information
Small, Single phase input type (1-Stage filter)
EAC -10 -472 –
O
EAC/EAM/EAP series
1
2
3
4
1
Series Name
2
Rated Current
R
3
Line to ground capacitor code: Refer to table 1.1.
table1.1 Line to ground capacitor code
E
A
E
CA
E
M
A
P
Line to ground
Leakage Current
(Input 125/250V 60Hz)
Code
capacitor
(nominal value)
000
101
221
331
● ●
● ●
12.5 A
/ 25
A max
● ●
25
A /
50 A
max
● ●
37.5 A
/ 75
A max
● ●
50
A /
100 A
max
●
75.5 A
/ 150
A max
●
●
●
●
5
A /
10 A
max Not Provided
100pF
220pF
330pF
470pF
680pF
471
681
●
102
●
222
●
332
●
472
●
0.13mA / 0.25mA max
1,000pF
0.25mA / 0.5
mA max
2,200pF
0.38mA / 0.75mA max
3,300pF
0.5 mA
/ 1.0 mA
max 4,700pF
When the line to ground capacitor code is
different, the attenuation characteristic is
different.
*
4
Option
D
:
DIN rail installation type
The terminal cover is retracted inside the unit
DIN rail installation type is option
The dimensions change when the option is set.
Refer to External view.
*
Features of EAC/EAM/EAP series
Single Phase 250VAC (1-Stage filter)
Small size
–
–
Quick and easy push-down terminal
–
ꢀ
Just connect the wires, push-down and tighten the screws with a screwdriver
EA
C
:
A
ttenuation type from 150kHz to 1MHz
EA
P
:
O
utside impulse attenuation type
EAM : Low leakage current type
Specifications
EAC-03-472
EAM-03-000
EAP-03-472
EAC-06-472
EAM-06-000
EAP-06-472
EAC-10-472
EAM-10-000
EAP-10-472
EAC-16-472
EAM-16-000
EAP-16-472
EAC-20-472
EAM-20-000
EAP-20-472
EAC-30-472
EAM-30-000
EAP-30-472
No.
Items
1
2
Rated Voltage[V]
Rated Current[A]
AC 1
f
250 / DC250
3
6
10
16
20
30
3
Test Voltage (Terminal-Mounting Plate)
2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
4
Isolation Resistance (Terminal-Mounting Plate)
500 VDC 500M
W
min at room temperature and humidity
5
6
Leakage current
DC resistance
Refer to table 1.1
180m
W
max 110m
W
max
40m
W
max
20m
W
max
10m
W
max
6m
W
max
7
8
9
Safety agency approval temperatures
Operating temperature
Operating humidity
-25 to +85
C
(Refer to Derating Curve)
-40 to +85
C
(Refer to Derating Curve)
20 to 95%RH (Non condensing)
10
11
12
13
14
Storage temperature/humidity
Vibration
Impact
Safety agency approvals
Case size (without projection) /Weight
-40 to +85
C
/20 to 95%RH (Non condensing)
2
10 to 55Hz, 19.6m/s
(2G), 3min. Period, 1hour each X, Y and Z axis
2
196.1m/s (20G),
11ms Once each X, Y and Z axis
UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565
T
e
il3-1, ENEC
(At only AC input)
39
X
30
X
85 mm [1.54
X
1.18
X
3.35 inches] (W
X
H
X
D) /170g max (Option : -D refer to external view)
Circuit Diagram
Derating Curve
Case
100
80
3
1
60
CY
CY
LINE
LOAD
40
4
2
20
0
-40
-30
-20
40
50 55 60
70
80
90
Ambient Temperature [
C
]
: Mounting Plate
CY : Line to ground capacitor
October 06, 2021
EA/ES-1
EAC/EAM/EAP series
External view
This product is shipped in the following condition,because it is equipped with push-down terminals.
1
The terminal cover is retracted inside the unit.
2
The screws for connecting the terminals are held in the up right position.
Standard Type
85
[3.35]
0.5
75
[2.95]
72
2.5
[0.1]
21
[2.83]
M4
[0.83]
11.5
[0.45]
Terminal cover
Mounting Plate
Protection Earth
2-M4
Input
Terminal
2-M4
Name Plate
Output
Terminal
M4
Terminal cover
2-
f
4.8
Terminal cover
[0.19]
Mounting Hole
Protection Earth
¶
Closed the terminal cover
¶
Tolerance :
1 [
0.04]
¶
Weight : 170g max
¶
Mounting Plate : Iron (surface finishing:nickel plating)
㹲
=1.0 [0.04]
¶
Case
㸸
PBT
¶
Dimensions in mm, [
]=inches
¶
Terminal block screw tightening torque M4
㸸
1.6N
࣭
m(16.9kgf
࣭
cm)max
DIN rail installation Type
+2
8.5
[0.33]
-1
85
[3.35]
72
[2.83]
M4
2.5
[0.1]
21
[0.83]
Protection Earth
Mounting Plate
2-M4
Terminal cover
11.5
[0.45]
2-M4
Input
Terminal
Name Plate
Output
Terminal
Terminal cover
M4
Terminal cover
Protection Earth
¶
Closed the terminal cover
¶
Tolerance :
1 [
0.04]
¶
Weight : 170g max
¶
Mounting Plate : Iron (surface finishing:nickel plating)
㹲
=1.0 [0.04]
¶
Case
㸸
PBT
¶
Dimensions in mm, [
]=inches
¶
Terminal block screw tightening torque M4
㸸
1.6N
࣭
m(16.9kgf
࣭
cm)max
DIN rail
(4.2)
[0.17]
Note when installing the EMI/EMC
¡
Filter on a DIN rail.
DIN rail
When the EMI/EMC Filter is grounded through
the DIN rail, the proper noise attenuation may not
be achieved.
Name Plate
Be sure to connect the protection earth (PE) of
the EMI/EMC Filter body to the earth.
At least one PE connection is required.
October 06, 2021
EA/ES-2