Cosel-FTA-100-104-S

Part #Cosel-FTA-100-104-S
Download 
Cosel-FTA-100-104-S
Ordering information  
Three phase input type(1-stage filter)  
FTA -80 -683 –
O  
FTA series
(80,100,125,150A)  
1
2
3
4
1
Model Name  
2
Rated Current  
3
Line to ground capacitor code:See table 1.1.  
table1.1 Line
 
to ground capacitor code  
R
Leakage Current  
Line to ground  
Code (Input
 
250/500V 60Hz)
 
capacitor  
(155,335only 250/400V 60Hz)
 
(nominal value)  
223  
683  
104  
155  
335  
1.0mA/2.0mA max  
2.5mA/5.0mA max  
3.5mA/7.0mA max  
160mA/250mA max  
320mA/500mA max  
22,000pF  
68,000pF  
100,000pF  
1.5 F  
3.3 F  
*
When the line to ground capacitor code is  
different, the attenuation characteristic is different.  
4
Option  
H:Ultra high attenuation type  
“155”,”335″ is not applied.  
S:Hexagon socket head cap screw  
(Standard type is Hexagon head screw)  
U:Improve differential mode attenuation  
(Rated voltage 250V)  
G:With switch of line to ground capacitor  
Only “155”,”335″ is applied.  
Features of FTA series  
Book type (Space-saving type)  
–
1-stage filter General-purpose High-attenuation (150kHz – 1MHz)  
–
Selectable leakage current value, Ultra high attenuation type  
“155”,”335″ for EU  
“155” is Leakage current 160mA/250mA max  
when the switch state is ON (switched to “
 
”).  
50μA/80μA max when the switch state is OFF  
*
(switched to  
“ ”
).  
(Wye type with neutral earth system), With switch of line to ground capacitor “-G”  
“335” is Leakage current 320mA/500mA max  
when the switch state is ON (switched to “
 
”).  
50μA/80μA max when the switch state is OFF  
(switched to “
 
”).  
Specifications  
No.  
1
2
Items  
Rated Voltage[V]  
Rated Current[A]  
FTA-80-683  
AC Three phase 500 (voltage range:528 max)
 
50/60Hz
*
1
*
2  
80 100
 
125  
FTA-100-683  
FTA-125-683  
FTA-150-683  
150  
3
4
5
6
Test Voltage (Terminal-Mounting Plate)  
Isolation Resistance (Terminal-Mounting Plate)  
Leakage current 250/500V 60Hz  
DC resistance  
2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity
 
*
3  
500 VDC 100M
W
min at room temperature and humidity
 
*
4  
2.5mA/5.0mA max  
5m
W
max  
4m
W
max  
3m
W
max  
3m
W
max  
7
8
9
Safety agency approval temperatures  
Operating temperature  
Operating humidity  
-25 to +85
C
(Refer to Derating Curve)  
-40 to +85
C
(Refer to Derating Curve)  
20 to 95%RH (Non condensing)  
10  
11  
12  
13  
Storage temperature/humidity  
Vibration  
Impact  
-40 to +85
C
/20 to 95%RH (Non condensing)  
2
10 to 55Hz, 19.6m/s (2G), 3min. Period, 1hour each X, Y and Z axis  
2
196.1m/s (20G), 11ms Once each X, Y and Z axis  
Safety agency approvals  
UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565
T
e
il3-1, ENEC  
100
X
130
X
210 mm (W
X
H
X
D)  
100
X
170
X
260 mm(W
X
H
X
D)  
(Option: -G refer to external view)  
(Option: -G refer to external view)  
14  
15  
Case size (without projection)  
[3.94
X
5.12
X
8.27 inches]  
[3.94
X
6.69
X
10.24 inches]  
Weight  
3.1kg max  
4.2kg max  
*
1
Only capacitor
 
code and option “155”,“335”, Three Phase
D
-connection:400 (440 max), Wye-connection:500(528 max)  
*
2
Only option “U”, Three Phase 250(275 max)  
*
3
Only capacitor
 
code and option “155”,“335”, 2,800VDC (Cutoff Current = 10mA), 1minute at room temperature and humidit
y
.  
*
4
Only capacitor
 
code and option “155”,“335”, Isolation resistance specification is deleted.  
Circuit Diagram  
(1) Line to ground capacitor code : 223, 683, 104  
(2) Line to ground capacitor code : 155, 335  
(3) Line to ground capacitor code : 223, 683, 104  
Option : U  
Case  
LINE  
Case  
LINE  
Case  
LINE  
LOAD  
LOAD  
LOAD  
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
CY  
CY  
CY  
CY  
CY CY  
CY :
Line to ground capacitor  
: Mounting Plate  
CY :
Line to ground capacitor  
: Mounting Plate  
CY :
Line to ground capacitor  
: Mounting Plate  
(4) Line to ground capacitor code : 155, 335  
Option : U  
(5) Line to ground capacitor code : 155, 335  
Option : G  
Derating Curve  
Case  
LINE  
Case  
LINE  
LOAD  
LOAD  
100  
80  
60  
40  
20  
0
1
2
3
4
5
6
1
2
3
4
5
6
CY CY  
CY CY  
SW  
-40  
-30 -20  
Ambient Temperature [
C
]  
*
Keep free ventilation holes for cooling.  
40  
50  
60  
70  
80  
90  
CY :
Line to ground capacitor  
: Mounting Plate  
SW : Switch  
CY :
Line to ground capacitor  
: Mounting Plate  
(The switch state is OFF)  
July 08, 2020  
FTA-7  

FTA series (80,100,125,150A)  
External view  
FTA-80 / FTA-100 / FTA-125  
210  
[8.27]  
169  
3-M8 (Option-S:  
Hexagon socket  
[6.65]  
head cap screws)  
Output Terminal  
M6 (Option-S:  
Hexagon socket  
head cap screws)  
M6 (Option-S:  
Hexagon socket  
head cap screws)  
Name Plate  
Protection Earth  
3-M8 (Option-S:  
Hexagon socket  
head cap screws)  
Protection Earth  
Input Terminal  
Terminal Cover  
Terminal Cover  
The air hole for heat radiation is not on the opposite side side.  
Mounting Hole  
Tolerance : ±1 [±0.04]  
Weight : 3.1kg max  
2- 6.5  
[0.26]  
Mounting Plate : Aluminum t=2.0 [0.08]  
Dimensions in mm, [
 
]=inches  
Terminal block screw tightening torque  
M8 : 9.2N
 
m(93.9kgf cm)max  
Protection Earth (PE) screw tightening torque  
M6 : 5.8N
 
m(59.2kgf cm)max  
Can not be mounted upside-down  
(mounted the top surface)  
Mounting Plate  
Keep free ventilation holes for cooling  
Mounting Hole  
±0.5  
195  
[7.68]  
FTA-80 / FTA-100 / FTA-125 with switch of line to ground capacitor ON/OFF  
210  
[8.27]  
3-M8 (Option-S:  
Hexagon socket  
head cap screws)  
Output Terminal  
169  
[6.65]  
M6 (Option-S:  
Hexagon socket  
head cap screws)  
M6 (Option-S:  
Hexagon socket  
head cap screws)  
Name Plate  
Protection Earth  
3-M8 (Option-S:  
Hexagon socket  
head cap screws)  
Protection Earth  
Input Terminal  
Terminal Cover  
Terminal Cover  
Tolerance : ±1 [±0.04]  
Weight : 3.1kg max  
With switch of line to  
ground capacitor  
Mounting Plate : Aluminum t=2.0 [0.08]  
Dimensions in mm, [
 
]=inches  
Terminal block screw tightening torque  
M8 : 9.2N
 
m(93.9kgf cm)max  
Protection Earth (PE) screw tightening torque  
M6 : 5.8N
 
m(59.2kgf cm)max  
Can not be mounted upside-down  
(mounted the top surface)  
The air hole for heat radiation is not on the opposite side side.  
Mounting Hole  
2- 6.5  
[0.26]  
Mounting Plate  
Keep free ventilation holes for cooling  
The switch state is OFF at shipping  
Switch status
 
ON : “
 
“, OFF : ”  
“
HIGH LEAKAGE CURRENT  
first connect to erath  
±0.5  
195  
Mounting Hole  
[7.68]  
July 08, 2020  
FTA-8  

FTA series (80,100,125,150A)  
External view  
FTA-150  
260  
3-M8 (Option-S:  
[10.24]  
Hexagon socket  
head cap screws)  
219  
[8.62]  
Output Terminal  
M6 (Option-S:  
Hexagon socket  
head cap screws)  
Protection Earth  
Name Plate  
M6 (Option-S:  
Hexagon socket  
head cap screws)  
3-M8 (Option-S:  
Hexagon socket  
head cap screws)  
Protection Earth  
Input Terminal  
Terminal Cover  
Terminal Cover  
The air hole for heat radiation is not on the opposite side side.  
Mounting Hole  
Tolerance : ±1 [±0.04]  
Weight : 4.2kg max  
2- 6.5  
[0.26]  
Mounting Plate : Aluminum t=2.0 [0.08]  
Dimensions in mm, [
 
]=inches  
Terminal block screw tightening torque  
M8 : 9.2N
 
m(93.9kgf cm)max  
Protection Earth (PE) screw tightening torque  
M6 : 5.8N
 
m(59.2kgf cm)max  
Can not be mounted upside-down  
(mounted the top surface)  
Mounting Plate  
Mounting Hole  
Keep free ventilation holes for cooling  
±0.5  
245  
[9.65]  
FTA-150 with switch of line to ground capacitor ON/OFF  
260  
3-M8 (Option-S:  
Hexagon socket  
head cap screws)  
[10.24]  
219  
[8.62]  
Output Terminal  
M6 (Option-S:  
Hexagon socket  
head cap screws)  
Protection Earth  
Name Plate  
M6 (Option-S:  
Hexagon socket  
3-M8 (Option-S:  
Hexagon socket  
head cap screws)  
head cap screws)  
Protection Earth  
Input Terminal  
Terminal Cover  
Terminal Cover  
With switch of line to  
ground capacitor  
Tolerance : ±1 [±0.04]  
Weight : 4.2kg max  
Mounting Plate : Aluminum t=2.0 [0.08]  
Dimensions in mm, [
 
]=inches  
Terminal block screw tightening torque  
M8 : 9.2N
 
m(93.9kgf cm)max  
Protection Earth (PE) screw tightening torque  
M6 : 5.8N
 
m(59.2kgf cm)max  
Can not be mounted upside-down  
(mounted the top surface)  
The air hole for heat radiation is not on the opposite side side.  
Mounting Hole  
2- 6.5  
[0.26]  
Keep free ventilation holes for cooling  
The switch state is OFF at shipping  
Mounting Plate  
Switch status
 
ON : “
 
“, OFF : ”  
“
HIGH LEAKAGE CURRENT  
first connect to erath  
Mounting Hole  
±0.5  
245  
[9.65]  
July 08, 2020  
FTA-9