COTO-9852-05-20

Part #COTO-9852-05-20
Download 
COTO-9852-05-20
9814 & 9852 SURFACE MOUNT REED RELAYS  
9814 & 9852 Series Surface Mount Reed Relays  
Ideally suited to the needs of Automated
T
e
st Equipment, Instrumentation and  
T
e
lecommunications requirements, Coto’s 9814 & 9852 Series is a miniature Surface  
Mount Reed Relay that combines small size with exceptional RF performance. e  
9814 extends life at ATE loads 3X or more utilizing Coto’s proprietary switch technol-  
ogy. e external Magnetic Shield reduces interaction between parts in high density  
boards. e 9852 adds Form C capability. Small size plus added features allow for high  
density packing, and make these relays ideal for designs such as high speed, high pin  
count VLSI testers where high speed, small size and high performance are all needed.  
9814 & 9852 Series Features  
u
Available in Axial, Gull wing and “J” lead configurations  
u
Tape and Reel packaging available  
u
High reliability, hermetically sealed contacts for long life  
12  
u
High Insulation Resistance – 10
 
Ω
minimum (Form A)  
u
Coaxial shield for 50
Ω
impedance  
u
6.5 GHz bandwidth for RF and Pulse switching (fast rise time pulses)  
u
External Magnetic Shield  
RoHS compliant  
u
DIMENSIONS  
in Inches (Millimeters)  
Models 9814 & 9852  
.040 MAX  
(1.02)  
.400  
(10.16)  
.015 TYP  
.207 MAX  
(0.38)  
(5.26)  
.040  
(1.02)  
TYP  
Axial

2  

J-Lead

2  

MAX.  
Gull Wing

2  

Ordering Information  
9XXX-XX-XX  
Part Number  
Model Number  
9814 9852  
NOTE  
Lead Style  
00 = Gull Wing  
10 = Axial  
u
For RF Graph Performance, see “RF Graphs” section  
of the
Reed Relay Technical & Application Information  
Coil Voltage  
03 = 3.3 volts (9814)  
05 = 5 volts  
20 = J- Lead  
11082019  

9814  
9852  
MODEL NUMBER  
Parameters  
Test Conditions  
Units  
1 Form A  
50
Ω
Coaxial  
1 Form C  
50
Ω
Coaxial  
COIL SPECS.  
Nom. Coil Voltage  
Max. Coil Voltage  
Coil Resistance  
VDC  
VDC  
3.3  
4
5
5
6
6
+/- 10%, 25° C  
Must Operate by  
Must Release by  
Ω
70  
2.5  
0.4  
150  
3.8  
0.4  
110  
3.8  
0.4  
Operate Voltage  
Release Voltage  
VDC – Max.  
VDC – Min.  
CONTACT RATINGS  
Switching Voltage  
Switching Current  
Carry Current  
Max DC/Peak AC Resist.  
Max DC/Peak AC Resist.  
Max DC/Peak AC Resist.  
Max DC/Peak AC Resist.  
Volts  
Amps  
Amps  
Watts  
100  
0.25  
0.5  
3
30  
0.1  
0.2  
3
Contact Rating  
100 N/C  
200 N/O  
Life Expectancy-Typical

1  

Signal Level 1.0V, 10mA  
50mV, 10mA  
x 10

6

Ops.  
1000  
Static Contact  
Resistance (max. init.)  
Ω
Ω
0.125  
0.150  
0.200  
0.200  
Dynamic Contact  
Resistance (max. init.)  
0.5V, 50mA  
at 100 Hz, 1.5 msec  
RELAY SPECIFICATIONS  
Insulation Resistance  
(minimum)  
Between all Isolated Pins  
at 100V, 25°C, 40% RH  
Ω
10

12  

10

9  

No Shield  
Shield Floating  
Shield Guarding  
pF  
pF  
pF  
–
–
–
–
1.0  
Capacitance – Typical  
Across Open Contacts  
0.2  
No Shield  
Shield Floating  
Shield Guarding  
pF  
pF  
pF  
–
–
–
–
1.0  
Open Contact to Coil  
0.5  
Closed Contact to Coil  
Contact to Shield  
Shield Guarding  
pF  
pF  
0.5  
–
0.5  
–
Contacts Open, Shield Floating  
Between Contacts  
Contacts to Shield  
Contacts/Shield to Coil  
VDC/peak AC  
VDC/peak AC  
VDC/peak AC  
200  
1500  
1500  
200  
1000  
1000  
Dielectric Strength  
(minimum)  
Operate Time – including  
bounce – Typical  
At Nominal Coil Voltage,  
30 Hz Square Wave  
msec.  
0.25  
1.0  
Release Time – Typical  
msec.  
0.05  
1.0  
2
4
6
8
2 4  
6 8  
Top View:  
Dot stamped on top of relay refers to pin #1 location  
Notes:  
1
Consult factory for life expectancy at other switching
 
loads. Contact resistance  
2.0
Ω
defines end of life.  
Surface mount component processing temperature: 500°F / 260°C max for 1 min-  
ute dwell time. Temperature measured on leads where lead exits molded package.  
2
1
3 5  
7
1
3 5  
7
Environmental Ratings:  
Storage Temp:
-35°C to

+

100°C;
Operating Temp:
-20°C to

+

85°C  
All electrical parameters measured at 25°C unless otherwise specified.  
Vibration:
20 G’s to 2000 Hz;
 
Shock:
50 G’s  
11082019