Crouzet-PJRX110A

Part #Crouzet-PJRX110A
Download 
Crouzet-PJRX110A
CONTROLS  
CONTROLS  
JR SERIES  
ALTERNATING RELAY  
UL listed
 
CSA recognized  
• Duplex
 
Alternating Control  
• SPDT
 
or DPDT Control Relay  
• 10
 
Amp Rated  
• Externally
 
Controlled  
The electronic alternating relay is designed to replace mechanical  
style devices used in control applications requiring a duplexing  
or alternating action of the control circuits to operate pumps,  
compressors, etc. This is achieved by activating a control switch  
which is common to one side of the input control voltage. The output  
contact of the relay(s) change state when this switch is opened  
(on de-energization of the control circuit). When the control initiate  
switch is actuated and released or opened, the relay will change  
state. The next time the initiate switch is actuated and released it  
will change back to its original state. Two red LED’s located on the  
top of the dust resistant enclosure provide the status of the relay.  
SPECIFICATIONS:  
WIRING DIAGRAM:  
Input
. . . . . . . . . . . . . . . . . . . . . . . .
 
24 VAC/DC, 110, 220 VAC  
15%, 50/60 Hz  
Maximum power consumption
 
. . .
 
24 VAC: 1.5 VA  
110 VAC: 5 VA  
220 VAC: 11 VA  
Output
. . . . . . . . . . . . . . . . . . . . . .
 
SPDT 10 A resistive  
DPDT 10 A resistive  
PJR  
PJRX  
LJR2  
INITIATE  
INITIATE  
SWITCH  
SWITCH  
*
*
4
5
8
4
5
6
7
5
DPDT 10 A crosswired  
3
3
2
6
7
6
7
4
8
Minimum pulse
 
. . . . . . . . . . . . . . .
 
30 ms  
Contact material
 
. . . . . . . . . . . . . .
 
AgCdO  
Maximum loading
 
. . . . . . . . . . . . .
 
10 A AC resistive 8 A DC inductive  
3
9
2
10  
2
1
1
8
1
11  
Maximum switching voltage
 
. . . . .
 
250 VAC  
Relay maximum power rating
 
. . . .
 
2200 VA  
Mechanical life of relay
 
. . . . . . . . .
 
3 x 10

6

operations  
250 VDC  
80 W  
INITIATE SWITCH*  
Electrical life of relay
 
. . . . . . . . . . .
 
2 x 10

5

at 2200 VA resistive load  
* INITIATE SWITCH must be isolated from other circuits  
Operating temperature
 
. . . . . . . . .
 
14°F to 140°F  
Weight
. . . . . . . . . . . . . . . . . . . . . .
 
2.8 oz. (100g)  
-10°C to +60°C  
ORDERING INFORMATION:  
L
JR2  
110A  
MOUNTING  
SERIES  
INPUT POWER  
SERIES  
INPUT POWER  
24A
= 24 VAC/DC  
110A
= 110 VAC  
220A
= 220 VAC  
MOUNTING  
L
= 11 pin plug-in  
P
= 8 pin plug-in  
JR2
= DPDT (LJRZ only)  
JR
= SPDT  
JRX
= DPDT crosswired  
Products and specifications subject to change without notice.  
2/78  

CONTROLS  
CONTROLS  
JRS SERIES  
ALTERNATING RELAY WITH  
SELECTOR SWITCH  
UL listed  
• Duplex
 
Alternating Control  
• SPDT
 
or DPDT Control Relay  
• 10
 
Amp Rated  
• Externally
 
Controlled  
• Selection
 
of Lead or Lag Load  
2
The electronic alternating relay is designed to replace mechanical  
style devices used in control applications requiring a duplexing  
or alternating action of the control circuits to operate pumps,  
compressors, etc. This is achieved by activating a control switch  
which is common to one side of the input control voltage. The  
output contact of the relay(s) change state when this switch is  
opened (on de-energization of the control circuit). When the control  
initiate switch is actuated and released or opened, the relay will  
change state. The next time the initiate switch is actuated, it will  
change back to its original state. Two red LED’s located on the top  
of the dust resistant enclosure provide the status of the relay. A 3  
Position Selector switch is installed for selection of normal opera-  
tion (alternating) or selection of lead or lag load.  
SPECIFICATIONS:  
WIRING DIAGRAM:  
Input
. . . . . . . . . . . . . . . . . . . . . . . .
 
24 VAC/DC, 110, 220 VAC  
15%, 50/60 Hz  
Maximum power consumption
 
. . .
 
24 VAC: 1.5 VA  
110 VAC: 5 VA  
220 VAC: 11VA  
Output
. . . . . . . . . . . . . . . . . . . . . .
 
SPDT 10 A resistive  
DPDT 10 A resistive  
PJRS  
PJRXS  
LJRS2  
INITIATE  
INITIATE  
SWITCH  
SWITCH  
4
5
8
4
5
6
7
5
DPDT 10 A crosswired  
3
3
2
6
7
6
7
4
8
Minimum pulse
 
. . . . . . . . . . . . . . .
 
30 ms  
Contact material
 
. . . . . . . . . . . . . .
 
AgCdO  
Maximum loading
 
. . . . . . . . . . . . .
 
10 A AC resistive 8 A DC inductive  
3
9
2
10  
2
1
1
8
1
11  
Maximum switching voltage
 
. . . . .
 
250 VAC  
Relay maximum power rating
 
. . . .
 
2200 VA  
Mechanical life of relay
 
. . . . . . . . .
 
3 x 10

6

operations  
250 VDC  
80 W  
INITIATE SWITCH  
Electrical life of relay
 
. . . . . . . . . . .
 
2 x 10

5

at 2200 VA resistive load  
Operating temperature
 
. . . . . . . . .
 
14°F to 140°F  
Weight
. . . . . . . . . . . . . . . . . . . . . .
 
2.8 oz. (100g)  
-10°C to +60°C  
ORDERING INFORMATION:  
L
JRS 2  
110A  
MOUNTING  
SERIES  
INPUT POWER  
SERIES  
INPUT POWER  
24A
= 24  
MOUNTING  
L
= 11 pin plug-in  
P
= 8 pin plug-in  
LJRS 2
= DPDT  
PJRS
= SPDT  
PJRXS
= DPDT (crosswired)  
VAC/DC  
110A
= 110 VAC  
220A
= 220 VAC  
NOTE:
DPDT relay available only with 11 pin plug-in (L)
.  
Products and specifications subject to change without notice.  