Curtis-Industries-F1400BB10
| Part # | Curtis-Industries-F1400BB10 |
| Download | Curtis-Industries-F1400BB10 |
F1400 RFI Filters
Speci
fi
cations
:
Rated Voltage:
250VAC Maximum – 50/60 Hz
Features:
Rated Current:
115VAC
3A
250VAC
1.5A
4A
• High
Peak Current Design — High Insertion Loss for
Switching Power Supply Emissions
• Low-Leakage
Current
6A
10A
6A
Current Overload:
6X for 8 seconds
• Compact
Case Sizes in 6 and 10Amp Models
• Available
with Integral IEC Connector in 3 and 6Amp
Models
Hi-Pot Test (1 min):
Line to Ground
Line to Line
1500VAC
1768VDC
Insulation Resistance:
9 x 10
9
Ω
at 100VDC
Ambient Temperature:
40°C Max. at rated current
Humidity Range:
0% to 95% R.H.
F1400 Simpli
fi
ed Schematic
L
L
G
N
Termination:
A: QC – Quick Connect
B: Wire
N
C: IEC Receptacle
Maximum Leakage Current:
Each Line to Ground
115VAC, 60Hz:
250VAC, 50Hz:
F1400
0.25mA
0.40mA
Agency Approvals:
MINIMUM INSERTION LOSS – dB (50 ohm Circuit)
Frequency – MHz
Nominal
Current
Rating
Part
Number
Termination
Line/Load
MODE
.15
.50
1.0
5.0
10
30
F1400AA03
F1400BB03
F1400CA03
QC/QC
Wire/Wire
IEC/QC
Common
Differential
58
40
65
60
65
65
65
65
60
65
44
60
3A
F1400AA06
F1400BB06
F1400CA06
QC/QC
Wire/Wire
IEC/QC
Common
Differential
58
36
65
55
65
60
65
60
60
55
54
50
6A
F1400AA10
F1400BB10
QC/QC
Wire/Wire
Common
Differential
56
40
65
50
65
60
65
65
60
65
54
60
10A
NOTE: Other combinations of terminals may be speci
fi
ed on special order.
Speci
fi
cations subject to change.
Dimensions are shown for
reference purposes only.
16
Curtis Industries
A Division of Powers Holdings, Inc.
F1400AA
(3, 6 and 10Amp) Dimensions
.188 Dia.
(4,77)
2 Holes
A
D
L
I
N
E
L
O
A
D
B
F
E
F
Amps
A
B
C
D
E
F
3.310
(84,1)
2.000
(50,8)
1.500
(38,2)
2.940
(74,7)
2.500
(63,5)
.550
(14,0)
3A
C
3.310
(84,1)
2.000
(50,8)
1.500
(38,2)
2.940
(74,7)
2.500
(63,5)
.550
(14,0)
6A
.250 QC
(6,4)
4.70
(119,4)
2.250
(57,1)
1.750
(44,4)
4.250
(107,9)
3.750
(95,3)
.550
(14,0)
10A
F1400BB
(3, 6 and 10Amp) Dimensions
Amps
A
B
C
D
E
A
D
3.310
(84,1)
2.000
(50,8)
1.500
(38,1)
2.940
(74,7)
2.500
(63,5)
3A
3.310
(84,1)
2.000
(50,8)
1.500
(38,1)
2.940
(74,7)
2.500
(63,5)
L
I
N
E
L
O
A
D
6A
B
2.250
(57,1)
1.750
(44,4)
4.250
(107,9)
3.750
(95,3)
4.70
(119,4)
10A
4.00
(101,6)
Min.
E
.250±.062
(6,35) Typ.
C
No. 18
Gauge Wire
F1400CA
(3 and 6Amp) Dimensions
(1) 5mm x 20mm Fuse (not included)
E
L
I
N
E
L
O
A
D
B
Refer to Page 40
for Standard
Mounting Cutouts
6-32
T
a
p
2-Places
A
D
Amps
A
B
C
D
E
2.880
(73,1)
2.120
(53,8)
1.500
(38,1)
.550
(14,0)
.565
(14,3)
3A
.250 QC
(6,4)
2.880
(73,1)
2.120
(53,8)
1.500
(38,1)
.550
(14,0)
.565
(14,3)
C
6A
Dimensions are in inches and millimeters
unless otherwise speci
fi
ed.
Values in parentheses are metric equivalents.
17
Curtis Industries
1-800-657-0853
A Division of Powers Holdings, Inc.
Standard Mounting Cutouts
F1200CA, F1300CA, F1400CA,
F1500CA, F1600CA, F1700CA
1.20
F1500FA, F1600FA,
.187
(30.5)
.638
(16,21)
✱
.09 R
(4,75)
(2,29)
1.275
(32,39)
.140 Dia.
(3,55)
2 Holes
.90
(22,9)
.140 Dia.
(3,55)
2 Holes
1.145
(29,08)
1.575
(40,0)
✱
for mounting
from back side
.234
.450
(5,94)
(11,43)
1.417
(36,0)
How to Order
The Curtis part numbering system is made up of four
elements. Each element denotes a speci
fi
c requirement
(mechanical or electrical) which, when properly
sequenced, fully identi
fi
es the required catalog
fi
lter. As
shown, the
fi
rst
fi
ve alpha/numeric characters denote
the series type; the sixth character (alpha) denotes the
type of line termination; the seventh character (alpha)
denotes the type of load termination; the last two
characters (numeric) denote the current rating.
F1300C
P
,
F
1600CP
1.500
(38,1)
.600
(15,2)
N
.700
(17,8)
.062 Hole Dia.
(1,57)
Compose your part number as follows: Select the series
required, add two alpha character for the line and load
termination, followed by two numeric characters for
the required current rating. For example, F1100AB06
completely identi
fi
es an F1100 series
fi
lter with quick
connects on line side and wire leads on load side, with
a 6-amp rating.
5 Holes
1.400
(35,6)
L
F5500/5600/5700 SERIES
F1100
X
X
X
SERIES
CURRENT
RATING
PE =
Power Entry
PM = Medical
Power Entry
1.575
(40,01)
01 =
1 Amp
03 =
3 Amps
06 =
6 Amps
10 =
10 Amps
15 =
15 Amps
20 =
20 Amps
30 =
30 Amps
LINE TERMINATION
A=
Q
uick
Connects
B=
W
ire
Leads
C= IEC
Connector
D= Screw
T
e
rminals
.90
(22,8)
.140 Dia.
(3,55)
LOAD
TERMINATION
A=
Q
uick
Connects
2 Holes
.234 R.
1.20
(20 & 30 amp only)
B
=
W
ire
Leads
(5,94)
(30,48)
(Typ.)
F =
Fused IEC
D= Screw
T
e
rminals
(20 & 30 amp only)
P=
P
rinted
Circuit Pins
S=
S
older
T
a
b
P=
P
rinted
Circuit Pins
W= Dual Fused IEC
J =
Switched IEC
Speci
fi
cations subject to change.
Dimensions are shown for
reference purposes only.
40
Curtis Industries
A Division of Powers Holdings, Inc.