Curtis-Industries-F1400BB10

Part #Curtis-Industries-F1400BB10
Download 
Curtis-Industries-F1400BB10
F1400 RFI Filters  
Speci
fi
cations
:  
Rated Voltage:
 
250VAC Maximum – 50/60 Hz  
Features:  
Rated Current:  
115VAC  
3A  
250VAC  
1.5A  
4A  
• High
 
Peak Current Design — High Insertion Loss for  
Switching Power Supply Emissions  
• Low-Leakage
 
Current  
6A  
10A  
6A  
Current Overload:
 
6X for 8 seconds  
• Compact
 
Case Sizes in 6 and 10Amp Models  
• Available
 
with Integral IEC Connector in 3 and 6Amp  
Models  
Hi-Pot Test (1 min):  
Line to Ground  
Line to Line  
1500VAC  
1768VDC  
Insulation Resistance:
 
9 x 10

9

Ω
at 100VDC  
Ambient Temperature:
 
40°C Max. at rated current  
Humidity Range:
 
0% to 95% R.H.  
F1400 Simpli
fi
ed Schematic  
L
L
G
N
Termination:  
A: QC – Quick Connect  
B: Wire  
N
C: IEC Receptacle  
Maximum Leakage Current:  
Each Line to Ground  
115VAC, 60Hz:  
250VAC, 50Hz:  
F1400  
0.25mA  
0.40mA  
Agency Approvals:  
MINIMUM INSERTION LOSS – dB (50 ohm Circuit)  
Frequency – MHz  
Nominal  
Current  
Rating  
Part  
Number  
Termination  
Line/Load  
MODE  
.15  
.50  
1.0  
5.0  
10  
30  
F1400AA03  
F1400BB03  
F1400CA03  
QC/QC  
Wire/Wire  
IEC/QC  
Common  
Differential  
58  
40  
65  
60  
65  
65  
65  
65  
60  
65  
44  
60  
3A  
F1400AA06  
F1400BB06  
F1400CA06  
QC/QC  
Wire/Wire  
IEC/QC  
Common  
Differential  
58  
36  
65  
55  
65  
60  
65  
60  
60  
55  
54  
50  
6A  
F1400AA10  
F1400BB10  
QC/QC  
Wire/Wire  
Common  
Differential  
56  
40  
65  
50  
65  
60  
65  
65  
60  
65  
54  
60  
10A  
NOTE: Other combinations of terminals may be speci
fi
ed on special order.  
Speci
fi
cations subject to change.  
Dimensions are shown for  
reference purposes only.  
16  
Curtis Industries  
A Division of Powers Holdings, Inc.  

F1400AA
(3, 6 and 10Amp) Dimensions  
.188 Dia.  
(4,77)  
2 Holes  
A
D
L
I
N
E
L
O
A
D
B
F
E
F
Amps  
A
B
C
D
E
F
3.310  
(84,1)  
2.000  
(50,8)  
1.500  
(38,2)  
2.940  
(74,7)  
2.500  
(63,5)  
.550  
(14,0)  
3A  
C
3.310  
(84,1)  
2.000  
(50,8)  
1.500  
(38,2)  
2.940  
(74,7)  
2.500  
(63,5)  
.550  
(14,0)  
6A  
.250 QC  
(6,4)  
4.70  
(119,4)  
2.250  
(57,1)  
1.750  
(44,4)  
4.250  
(107,9)  
3.750  
(95,3)  
.550  
(14,0)  
10A  
F1400BB
(3, 6 and 10Amp) Dimensions  
Amps  
A
B
C
D
E
A
D
3.310  
(84,1)  
2.000  
(50,8)  
1.500  
(38,1)  
2.940  
(74,7)  
2.500  
(63,5)  
3A  
3.310  
(84,1)  
2.000  
(50,8)  
1.500  
(38,1)  
2.940  
(74,7)  
2.500  
(63,5)  
L
I
N
E
L
O
A
D
6A  
B
2.250  
(57,1)  
1.750  
(44,4)  
4.250  
(107,9)  
3.750  
(95,3)  
4.70  
(119,4)  
10A  
4.00  
(101,6)  
Min.  
E
.250±.062  
(6,35) Typ.  
C
No. 18  
Gauge Wire  
F1400CA
(3 and 6Amp) Dimensions  
(1) 5mm x 20mm Fuse (not included)  
E
L
I
N
E
L
O
A
D
B
Refer to Page 40  
for Standard  
Mounting Cutouts  
6-32
T
a
p  
2-Places  
A
D
Amps  
A
B
C
D
E
2.880  
(73,1)  
2.120  
(53,8)  
1.500  
(38,1)  
.550  
(14,0)  
.565  
(14,3)  
3A  
.250 QC  
(6,4)  
2.880  
(73,1)  
2.120  
(53,8)  
1.500  
(38,1)  
.550  
(14,0)  
.565  
(14,3)  
C
6A  
Dimensions are in inches and millimeters  
unless otherwise speci
fi
ed.  
Values in parentheses are metric equivalents.  
17  
Curtis Industries  
1-800-657-0853  
A Division of Powers Holdings, Inc.  

Standard Mounting Cutouts  
F1200CA, F1300CA, F1400CA,  
F1500CA, F1600CA, F1700CA  
1.20  
F1500FA, F1600FA,  
.187  
(30.5)  
.638  
(16,21)  
✱
.09 R  
(4,75)  
(2,29)  
1.275  
(32,39)  
.140 Dia.  
(3,55)  
2 Holes  
.90  
(22,9)  
.140 Dia.  
(3,55)  
2 Holes  
1.145  
(29,08)  
1.575  
(40,0)  
✱
for mounting  
from back side  
.234  
.450  
(5,94)  
(11,43)  
1.417  
(36,0)  
How to Order  
The Curtis part numbering system is made up of four  
elements. Each element denotes a speci
fi
c requirement  
(mechanical or electrical) which, when properly  
sequenced, fully identi
fi
es the required catalog
fi
lter. As  
shown, the
fi
rst
fi
ve alpha/numeric characters denote  
the series type; the sixth character (alpha) denotes the  
type of line termination; the seventh character (alpha)  
denotes the type of load termination; the last two  
characters (numeric) denote the current rating.  
F1300C
P
,
F
1600CP  
1.500  
(38,1)  
.600  
(15,2)  
N
.700  
(17,8)  
.062 Hole Dia.  
(1,57)  
Compose your part number as follows: Select the series  
required, add two alpha character for the line and load  
termination, followed by two numeric characters for  
the required current rating. For example, F1100AB06  
completely identi
fi
es an F1100 series
fi
lter with quick  
connects on line side and wire leads on load side, with  
a 6-amp rating.  
5 Holes  
1.400  
(35,6)  
L
F5500/5600/5700 SERIES  
F1100  
X
X
X
SERIES  
CURRENT  
RATING  
PE =
 
Power Entry  
PM = Medical  
Power Entry  
1.575  
(40,01)  
01 =
 
1 Amp  
03 =
 
3 Amps  
06 =
 
6 Amps  
10 =
 
10 Amps  
15 =
 
15 Amps  
20 =
 
20 Amps  
30 =
 
30 Amps  
LINE TERMINATION  
A=
Q
uick
 
Connects  
B=
W
ire
 
Leads  
C= IEC
 
Connector  
D= Screw
 
T
e
rminals  
.90  
(22,8)  
.140 Dia.  
(3,55)  
LOAD  
TERMINATION  
A=
Q
uick
 
Connects  
2 Holes  
.234 R.  
1.20  
(20 & 30 amp only)
 
B
=
W
ire
 
Leads  
(5,94)  
(30,48)  
(Typ.)  
F =
 
Fused IEC  
D= Screw
 
T
e
rminals  
(20 & 30 amp only)  
P=
P
rinted
 
Circuit Pins  
S=
S
older
 
T
a
b  
P=
P
rinted
 
Circuit Pins  
W= Dual Fused IEC  
J =
 
Switched IEC  
Speci
fi
cations subject to change.  
Dimensions are shown for  
reference purposes only.  
40  
Curtis Industries  
A Division of Powers Holdings, Inc.