Diodes-Incorporated-MMBTA42Q-7-F
| Part # | Diodes-Incorporated-MMBTA42Q-7-F |
| Download | Diodes-Incorporated-MMBTA42Q-7-F |
MMBTA42
300V NPN SMALL SIGNAL TRANSISTOR IN SOT23
Features
Mechanical Data
BV
CEO
> 300V
Case: SOT-23
Ideal for Medium Power Amplification and Switching
Complementary PNP Type: MMBTA92
Case Mate
rial: Molded
Plastic, “Green” Molding C
ompound.
UL Flammability
Classification Rating 94V-0
Moisture Sensitivity: Level 1 per J-STD-020
Terminals: Finish-Matte Tin Plated Leads.
Solderable per MIL-STD-202, Method 208
Weight: 0.008 grams (Approximate)
Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2)
Halogen and Antimony Free. “Green” Device (Note 3)
Qualified to AEC-Q101 Standards for High Reliability
PPAP Capable (Note 4)
SOT23
C
E
B
B
C
E
Top View
Pin-Out
Top View
Device Symbol
Ordering Information
(Notes 4 & 5)
Part Number
MMBTA42-7-F
MMBTA42-13-F
MMBTA42Q-7-F
Compliance
AEC-Q101
AEC-Q101
Automotive
Marking
K3M
K3M
Reel size (inches)
Tape width (mm)
Quantity per reel
3,000
7
13
7
8
8
8
10,000
3,000
K3M
Notes:
1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant.
2. See
http://www.diodes.com/quality/lead_free.html
fo
r more information about Diodes Incorporated’s definitions of Hal
ogen- and Antimony-free, “Green”
and Lead-free.
3. Halogen- and Antimony-
free “Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and
<1000ppm antimony compounds.
4. Automotive
products are AEC-Q101 qualified and are PPAP capable. Automotive, AEC-Q101 and standard products are electrically and thermally
the same, except where specified.
Marking Information
SOT23
K3M = Product Type Marking Code
YM = Date Code Marking
K3M
Y = Year (ex: C = 2015)
M = Month (ex: 9 = September)
Date Code Key
Year
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
Code
C
D
E
F
G
H
I
J
K
L
M
N
Month
Code
Jan
1
Feb
2
Mar
3
Apr
4
May
5
Jun
6
Jul
7
Aug
8
Sep
9
Oct
O
Nov
N
Dec
D
1 of 5
October 2015
© Diodes Incorporated
MMBTA42
Document number: DS30062 Rev. 12 – 2
MMBTA42
Absolute Maximum Ratings
(@T
A
= +25°C, unless otherwise specified.)
Characteristic
Symbol
V
CBO
V
CEO
V
EBO
I
C
Value
300
300
6.0
Unit
V
Collector-Base Voltage
Collector-Emitter Voltage
Emitter-Base Voltage
V
V
Collector Current – Continuous
500
mA
Thermal Characteristics
(@T
A
= +25°C, unless otherwise specified.)
Characteristic
Symbol
P
D
Value
300
Unit
mW
°C/W
°C
Power Dissipation
(Note 6)
(Note 6)
Thermal Resistance, Junction to Ambient
Operating and Storage Temperature Range
417
R
JA
-55 to +150
T
J
, T
STG
ESD Ratings
(Note 7)
Characteristic
Electrostatic Discharge – Human Body Model
Electrostatic Discharge – Machine Model
Symbol
Value
4,000
400
Unit
V
JEDEC Class
ESD HBM
ESD MM
3A
C
V
Notes:
6. For a device mounted on minimum recommended pad layout 1oz copper that is on a single-sided FR4 PCB; device is measured under still air
conditions whilst operating in a steady-state.
7. Refer to JEDEC specification JESD22-A114 and JESD22-A115.
Electrical Characteristics
(@T
A
= +25°C, unless otherwise specified.)
Characteristic
OFF CHARACTERISTICS (Note 8)
Collector-Base Breakdown Voltage
Collector-Emitter Breakdown Voltage
Emitter-Base Breakdown Voltage
Collector Cut-Off Current
Symbol
Min
Max
Unit
Test Condition
I
C
= 100µA, I
E
= 0
I
C
= 1.0mA, I
B
= 0
I
E
= 100µA, I
C
= 0
V
CB
= 200V, I
E
= 0
V
EB
= 6.0V, I
C
= 0
300
300
6.0
V
V
V
nA
nA
BV
CBO
BV
CEO
BV
EBO
I
CBO
100
100
Emitter Cut-Off Current
I
EBO
ON CHARACTERISTICS (Note 8)
I
C
= 1.0mA, V
CE
= 10V
I
C
= 10mA,
V
CE
= 10V
I
C
= 30mA,
V
CE
= 10V
I
C
= 20mA, I
B
= 2.0mA
I
C
= 20mA, I
B
= 2.0mA
0.5
0.9
25
40
40
DC Current Gain
h
FE
Collector-Emitter Saturation Voltage
Base-Emitter Saturation Voltage
SMALL SIGNAL CHARACTERISTICS
Output Capacitance
V
V
V
CE(SAT)
V
BE(SAT)
3.0
pF
C
cb
f
T
V
CB
= 20V, f = 1.0MHz, I
E
= 0
V
CE
= 20V, I
C
= 10mA,
f = 100MHz
Current Gain-Bandwidth Product
50
MHz
Note:
8.
Measured under pulsed conditions. Pulse width ≤ 300µs. Duty cycle ≤ 2%
.
2 of 5
October 2015
© Diodes Incorporated
MMBTA42
Document number: DS30062 Rev. 12 – 2
MMBTA42
Typical Electrical Characteristics
400
350
300
250
2.0
1.8
1.6
1.4
I
C
I
B
= 10
T
A
= 150°C
1.2
1.0
0.8
0.6
0.4
200
150
T
A
= 25°C
100
50
T
A
= -50°C
0.2
0
0
0
200
175
1000
25
50
150
1
10
I
C
, COLLECTOR CURRENT (mA)
75 100
125
100
T
A
, AMBIENT TEMPERATURE (°C)
Fig. 2,
Collector Emitter Saturation Voltage
vs. Collector Current
Fig. 1, Max Power Dissipation vs
Ambient
T
emperature
10,000
1,000
100
1.0
V
CE
= 5V
V
CE
= 5V
0.9
0.8
0.7
T
A
= -50°C
T
A
= 150°C
0.6
0.5
T
A
= 25°C
T
A
= -50°C
T
A
= 25°C
0.4
0.3
10
1
T
A
= 150°C
0.2
0.1
10
1000
1
100
I
C
, COLLECTOR CURRENT (mA)
1
10
100
0.1
Fig. 3, DC Current Gain vs
Collector Current
I
C
, COLLECTOR CURRENT (mA)
Fig. 4, Base Emitter Voltage vs Collector Current
3 of 5
October 2015
© Diodes Incorporated
MMBTA42
Document number: DS30062 Rev. 12 – 2
MMBTA42
100
10
1
V
CE
= 5V
10
1
I
C
, COLLECTOR CURRENT (mA)
Fig. 5, Gain Bandwidth Product vs
Collector Current
Package Outline Dimensions
All 7°
H
GAUGE PLANE
SOT23
0.25
J
Dim
A
B
C
D
F
G
H
J
Min
Max
0.51
1.40
2.50
1.03 0.915
0.60 0.535
Typ
K
K1
0.37
1.20
2.30
0.89
0.45
1.78
2.80
0.40
1.30
2.40
a
M
A
L
L1
2.05
3.00
1.83
2.90
0.05
0.013 0.10
K
K1
L
L1
M
a
0.890 1.00 0.975
0.903 1.10 1.025
C
B
0.45
0.25
0.61
0.55
0.55
0.40
0.085 0.150 0.110
8°
D
G
F
All Dimensions in mm
Suggested Pad Layout
Y
Dimensions Value
(in mm)
Z
Z
X
Y
C
E
2.9
0.8
0.9
2.0
1.35
C
E
X
Note:
For high voltage applications, the appropriate industry sector guidelines should be considered with regards to creepage and clearance distances between
device terminals and PCB tracking.
4 of 5
October 2015
© Diodes Incorporated
MMBTA42
Document number: DS30062 Rev. 12 – 2
MMBTA42
IMPORTANT NOTICE
DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
(AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION).
Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes
without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the
application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or
trademark rights, nor the rights of others.
Any Customer or user of this document or products described herein in such applications shall assume
all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated
website, harmless against all damages.
Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel.
Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and
hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or
indirectly, any claim of personal injury or death associated with such unintended or unauthorized application.
Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings
noted herein may also be covered by one or more United States, international or foreign trademarks.
This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the
final and determinative format released by Diodes Incorporated.
LIFE SUPPORT
Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express
written approval of the Chief Executive Officer of Diodes Incorporated. As used herein:
A. Life
support devices or systems are devices or systems which:
1. are intended to implant into the body, or
2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the
labeling can be reasonably expected to result in significant injury to the user.
B. A
critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or to affect its safety or effectiveness.
Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any
use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related
information or support that may be provided by Diodes Incorporated.
Further, Customers must fully indemnify Diodes Incorporated and its
representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems.
Copyright © 2015, Diodes Incorporated
5 of 5
October 2015
© Diodes Incorporated
MMBTA42
Document number: DS30062 Rev. 12 – 2