Finder-Relays–Inc–34-51-7-060-0010

Part #Finder-Relays–Inc–34-51-7-060-0010
Download 
Finder-Relays–Inc–34-51-7-060-0010
34  
SЕRIES  
Ultra-slim PCB  
Relays (EMR or SSR)  
0.1 – 0.2 – 2 – 6 A  
Bottling plant  
Packaging  
machines  
Labelling  
machines  
Road / tunnel  
lighting  
Burners,  
boilers and  
furnaces  
Timers and  
lighting  
controls  
Electronic circuit  
boards  
Programmable  
controllers  

Prices, features, specifications, capabilities, appearance and availability of our products and services are subject to change without notice.  
FINDER assumes no responsibility for the presence of possible errors or insufficient information in this document.  
In case of discrepancies between the printed and online versions, the latter prevails.  

34 SERIES  
34  
Ultra
–
Slim electromechanical PCB relays 6 A  
SERIES  
Ultra-slim 1 Pole – 6 A relay  
34.51-xx10  
34.51-5×10  
34.51- 0000  
Printed circuit mount  
– direct or via PCB socket (according to type)  
35 mm rail mount  
– via screw, screwless or push-in terminal  
sockets  
A
•
1 Pole changeover contacts or  
•
5 mm wide  
•
5 mm wide  
•
5 mm wide  
1 Pole normally open contact  
•
Low coil power  
•
PCB or 93 series sockets  
•
Contact AgNi  
•
Low coil power  
•
Low coil power  
•
PCB only  
•
Ultra slim (5 mm), package  
•
PCB or 93 series sockets  
•
Contact AgNi + Au  
•
Sensitive DC coil – 170 mW (Dual AC/DC coil  
drive possible using 93 series sockets)  
•
UL Listing (certain relay/socket combinations)  
•
Cadmium Free contact materials  
•
8/8 mm clearance/creepage distance  
•
6 kV (1.2/50 μs) insulation, coil-contacts  
•
Contact AgSnO

2  

F
or
UL
ratings see
:  
“
General technical information
”
page
V
 
For outline drawing see page 9  
Contact specification  
Contact configuration  
Rated current/  
Copper side view  
Copper side view  
Copper side view  
1 CO (SPDT)  
6/10  
1 CO (SPDT)  
6/10  
1 CO (SPDT)  
6/10  
Maximum peak current  
A
Rated voltage/  
Maximum switching voltage  
V AC  
250/400  
1500  
250/400  
1500  
250/400  
1500  
Rated load AC1  
VA  
Rated load AC15 (230 V AC)  
Single phase motor rating (230 V AC)  
Breaking capacity DC1: 24/110/220 V  
Minimum switching load  
Standard contact material  
Coil specification  
VA  
300  
300  
300  
kW  
A
0.185  
0.185  
0.185  
6/0.2/0.12  
500 (12/10)  
AgNi  
6/0.2/0.12  
50 (5/2)  
AgNi + Au  
6/0.2/0.12  
500 (12/10)  
AgSnO

2  

mW (V/mA)  
Nominal voltage (U

N

)  
V AC (50/60 Hz)  
V DC  
—
5 – 12 – 24 – 48 – 60  
—/0.17  
—
5 – 12 – 24 – 48 – 60  
—/0.17  
—
24  
Rated power AC/DC  
Operating range  
VA (50 Hz)/W  
AC  
—/0.17  
—
—
—
DC  
(0.7…1.5)U

N  

—/0.4 U

N  

—/0.05 U

N  

(0.7…1.5)U

N  

—/0.4 U

N  

—/0.05 U

N  

(0.7…1.5)U

N  

—/0.4 U

N  

—/0.05 U

N  

Holding voltage  
AC/DC  
Must drop-out voltage  
Technical data  
AC/DC  
Mechanical life AC/DC  
Electrical life at rated load AC1  
Operate/release time  
cycles  
cycles  
ms  
—/10 · 10

6  

60 · 10

3  

5/3  
—/10 · 10

6  

60 · 10

3  

5/3  
—/10 · 10

6  

60 · 10

3  

5/3  
Insulation between coil  
and contacts (1.2/50 µs)  
Dielectric strength  
kV  
6 (8 mm)  
6 (8 mm)  
6 (8 mm)  
between open contacts  
V AC  
°C  
1000  
–40…+85  
RT II  
1000  
–40…+85  
RT II  
1000  
–40…+85  
RT III  
Ambient temperature range  
Environmental protection  
Approvals
(according to type)  
3

34 SERIES  
34  
Ultra
–
Slim solid state PCB relays (SSR) 0.1 – 6 A  
SERIES  
Ultra-slim Solid
 
State Relays  
Printed circuit mount  
34.81.7.xxx.9024  
34.81.7.xxx.8240  
– direct or via PCB socket  
35 mm rail mount  
– via screw, screwless or push-in terminal  
sockets  
A
•
Single circuit output switching options  
– 6 A, 24 V DC  
– 2 A, 240 V AC  
•
Silent, high speed switching with long  
electrical life  
•
6 A, 24 V DC output switching
 
•
2 A, 240 V AC output  
•
Ultra slim (5 mm), package  
•
Sensitive DC Input circuits (Dual AC/DC input  
drive possible using 93 series sockets)  
•
UL Listing (certain relay/socket combinations)  
•
Wash tight: RT III  
•
PCB or 93 series sockets  
switching  
•
Zero crossing switching  
•
PCB or 93 series sockets  
•
3000 V AC insulation, input-output  
input  
output  
input  
output  
For outline drawing see page 9  
Output circuit  
Copper side view  
1 NO (SPST-NO)  
Copper side view  
1 NO (SPST-NO)  
Contact configuration  
Rated current/  
Maximum peak current (10 ms)  
A
V
V
V
6/50  
2/80  
Rated switching voltage  
Switching voltage range  
Maximum blocking voltage  
24 DC  
240 AC (50/60 Hz)  
(1.5…33)DC  
(12…275)AC  
33  
—
—
800  
—
Repetitive peak off-state voltage  
Rated load DC13  
V

pk  

W
36  
Rated load AC15  
VA  
mA  
mA  
V
—
300  
35  
Minimum switching current  
Max. “OFF-state
”
l
eakage current  
Max. “ON-state
”
v
oltage drop  
Supply specification  
Nominal voltage (U

N

)  
Rated power  
1
0.001  
0.4  
1.5  
1.6  
V DC  
W
5
12  
24  
60  
5
12  
24  
60  
0.035 0.085  
0.17  
0.21  
0.06  
0.085  
0.17  
0.21  
Operating range  
V DC
 
3.5…12
8…17 16…30 35…72
3.5…10
8…17 16…30 35…72  
Control current  
mA  
7
4
7
4
7
3.5  
20  
12  
1
7
4
7
3.5  
20  
Release voltage  
V DC  
10  
10  
Technical data  
Electrical life at rated load  
Operate/release time  
cycles  
ms  
> 10

6  

> 10

6  

11/11  
4
0.02/0.2  
4
Insulation between input and output (1.2/50µs) kV  
Ambient temperature range  
Environmental protection  
°C  
–20…+70*  
RT III  
–20…+50*  
RT III  
Approvals
(according to type)  
* Note: all technical data relates to using the relay directly on PCB or PCB socket type 93.11.  
If the relay is used with 35 mm rail socket types 93.01 and 93.51, refer to the technical data of 38 Series; if used  
with types 93.60, 93.61, 93.62, 93.63, 93.64, 93.65, 93.66, 93.67,93.68 and 93.69, refer to the technical data of the  
Master
INTERFACE
39 Series. See L34 diagrams page 8  
4

34 SERIES  
34  
Ultra
–
Slim solid state PCB relays (SSR) 0.1 – 6 A  
SERIES  
Ultra-slim Solid
 
State Relays  
34.81.7.xxx.7048  
34.81.7.xxx.7220  
Printed circuit mount  
– direct or via PCB socket  
35 mm rail mount  
– via screw, screwless or push-in terminal  
sockets  
A
•
Single circuit output switching options  
– 0.1 A, 48 V DC  
– 0.2 A, 220 V DC  
•
Silent, high speed switching with long  
electrical life  
•
100 mA, 48 V DC output  
switching  
•
200 mA, 110/220 V DC output  
switching  
•
Ultra slim (5 mm), package  
•
Sensitive DC Input circuits (Dual AC/DC input  
drive possible using 93 series sockets)  
•
UL Listing (certain relay/socket combinations)  
•
Wash tight: RT III  
•
PCB or 93 series sockets  
•
PCB or 93 series sockets  
•
3000 V AC insulation, input-output  
input  
output  
input  
output  
For outline drawing see page 9  
Output circuit  
Copper side view  
1 NO (SPST-NO)  
Copper side view  
1 NO (SPST-NO)  
Contact configuration  
Rated current/  
Maximum peak current (10 ms)  
A
V
0.1/0.5  
48 DC  
(1.5…53)DC  
53  
0.2/10  
220 DC  
(90…256)DC  
256  
Rated switching voltage  
Switching voltage range  
Maximum blocking voltage  
Rated load DC13  
V
V
W
2.4  
44  
Minimum switching current  
Max. “OFF-state
”
l
eakage current  
Max. “ON-state
”
v
oltage drop  
Supply specification  
Nominal voltage (U

N

)  
Rated power  
mA  
mA  
V
0.05  
0.05  
0.001  
1
0.001  
0.4  
V DC  
W
24  
60  
0.21  
35…72  
3.5  
24  
60  
0.21  
35…72  
3.5  
0.17  
16…30  
7
0.17  
16…30  
7
Operating range  
V DC  
mA  
Control current  
Release voltage  
V DC  
10  
20  
10  
20  
Technical data  
Electrical life at rated load  
Operate/release time  
cycles  
ms  
> 10

6  

0.03/0.6  
4
> 10

6  

0.4/2.2  
4
Insulation between input and output (1.2/50µs) kV  
Ambient temperature range  
Environmental protection  
°C  
–20…+70*  
RT III  
–20…+70*  
RT III  
Approvals
(according to type)  
* Note: all technical data relates to using the relay directly on PCB or PCB socket type 93.11.  
If the relay is used with 35 mm rail socket types 93.01 and 93.51, refer to the technical data of 38 Series; if used  
with types 93.60, 93.61, 93.62, 93.63, 93.64, 93.65, 93.66, 93.67,93.68 and 93.69, refer to the technical data of the  
Master
INTERFACE
39 Series.  
5

34 SERIES  
Ultra-Slim PCB relays  
34  
SERIES  
Ordering information  
Electromechanical relay (EMR)  
Example: 34 series Ultra-Slim electromechanical relay, 1 CO (SPDT) 6 A contacts, 24 V sensitive DC coil.  
A
A
B
C
D
3 4
 
. 5
 
1 . 7 . 0
 
2 4
 
. 0  
0
1
0
Series  
Type  
A:
Contact material  
0 = Standard AgNi,  
Standard AgSnO

2  

D:
Special versions  
0 = Flux proof (RT II)  
9 = Flat version  
5 = Electromechanical type  
(for 34.51-0000 only)  
4 = AgSnO

2  

C:
Options  
No. of poles  
1 = 1 pole, 6 A  
5 = AgNi + Au  
0 = Production line 0  
1 = Production line 1  
B:
Contact circuit  
0 = CO (SPDT)  
3 = NO (SPST)  
Coil version  
7 = Sensitive DC  
Coil voltage  
See coil specifications  
Selecting features and options: only combinations in the same row are possible.  
Preferred selections for best availability are shown in
bold
.  
Type  
34.51  
34.51  
Coil version  
sens. DC  
A
B
C
D
0
9
0
– 4 – 5  
0 – 4 – 5  
0
– 3  
0
0 – 1  
1
sens. DC  
Solid state relay (SSR)  
Example: 34 series solid state relay, 6 A 24 V DC output, 24 V DC supply.  
3 4
 
. 8
 
1 . 7 . 0
 
2 4
 
. 9
 
0 2 4  
Output circuit  
Series  
9024 = 6 A – 24 V DC  
7048 = 0.1 A – 48 V DC  
7220 = 0.2 A – 220 V DC  
8240 = 2 A – 240 V AC  
Type  
8 = SSR type  
Output  
1 = 1 NO (SPST-NO)  
Input circuit  
See input specifications  
Flat pack version  
Option = 34.51.7xxx.x019  
Environmental protection RT I  
Copper side view  
6

34 SERIES  
Ultra-Slim PCB relays  
34  
SERIES  
Electromechanical relay  
Technical data  
Insulation according to EN 61810-1  
Nominal voltage of supply system  
Rated insulation voltage  
Pollution degree  
A
V AC
 
230/400  
V AC
 
250  
3
400  
2
Insulation between coil and contact set  
Type of insulation  
Reinforced  
III  
Overvoltage category  
Rated impulse voltage  
kV (1.2/50 μs)  
6
Dielectric strength  
V AC
 
4000  
Insulation between open contacts  
Type of disconnection  
Micro-disconnection  
V AC/kV (1.2/50 μs)
 
1000/1.5  
Dielectric strength  
Insulation between coil terminals  
Rated impulse voltage (surge) differential mode  
(according to EN 61000-4-5)  
kV (1.2/50 µs)  
2
Other data  
Bounce time: NO/NC  
Vibration resistance (5…55)Hz: NO/NC  
Shock resistance  
ms 1/6  
g
g
10/5  
20/14  
0.2  
Power lost to the environment  
without contact current  
with rated current  
W
W
0.5  
Recommended distance  
between relays mounted on PCB  
mm ≥
 
5  
Contact specification  
F 34 – Electrical life (AC) v contact current  
H 34 – Maximum DC1 breaking capacity  
Resistive load – cosφ = 1  
Inductive load – cosφ = 0.4  
DC voltage (V)  
•
When switching a resistive load (DC1) having voltage and current values  
under the curve, an electrical life of ≥ 60 · 10

3

can be expected.  
•
In the case of DC13 loads, the connection of a diode in parallel with the  
load will permit a similar electrical life as for a DC1 load.  
Note: the release time for the load will be increased.  
Coil specifications  
DC coil data  
R 34 – DC coil operating range v ambient temperature  
Nominal Coil
 
code  
voltage  
Operating range  
Resistance  
Rated coil  
consumption  
U

N  

V
U

min  

U

max  

V
R
Ω
I
at U

N  

mA  
38.4  
14.2  
7.1  
V
5
7
.005  
7
.012  
7
.024  
7
.048  
7
.060  
3.5  
8.4  
16.8  
33.6  
42  
7.5  
18  
36  
72  
90  
130  
12  
24  
48  
60  
840  
3350  
12300  
19700  
3.9  
3
1 –
Max. permitted coil voltage.  
2 –
Min. pick-up voltage with coil at ambient temperature.  
7

34 SERIES  
Ultra-Slim PCB relays  
34  
SERIES  
Solid state relay  
Technical data  
A
Insulation  
Dielectric strength  
Impulse (1.2/50 μs)  
Between input and output  
EMC specifications  
3000 V AC  
4 kV  
Reference standard  
Electrostatic discharge  
contact discharge  
air discharge  
EN 61000-4-2  
EN 61000-4-2  
EN 61000-4-3  
4 kV  
8 kV  
Radiated electromagnetic field
 
(80…1000 MHz)  
Fast transients on supply terminals  
(burst 5/50 ns, 5 and 100 kHz)  
10 V/m  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-5  
EN 61000-4-6  
2 kV  
common mode  
differential mode  
0.7 kV  
0.7 kV*  
10 V  
Voltage pulses on supply terminals  
(surge 1.2/50 μs)  
Radio-frequency common mode voltage (0.15…230 MHz)  
Other data  
Power lost to the environment  
without output current  
with rated current  
W
W
0.15  
0.4  
* For 34.81.7.005…= 0.3 kV ; for 34.81.7.012…= 0.5 kV  
Input specification  
Input data – DC types  
Nominal  
voltage  
Input  
code  
Operating range  
Release Impedance  
voltage  
Control  
current  
U

N  

V
U

min  

V
U

max  

V
I
at U

N  

mA  
7*  
V
1
Ω
5
7
.005  
7
.012  
7
.024  
7
.060  
3.5  
8
12*  
17  
715  
12  
24  
60  
4
1715  
3430  
17000  
7
16  
35  
30  
10  
20  
7
72  
3.5  
* For 34.81.7.005.8240: U

MAX

= 10 V, I @ 5 V = 12 mA  
Output specification  
L 34-1 – Output DC current v ambient temperature  
L 34 – Output AC current v ambient temperature  
34.81.7…9024  
34.81.7…8240  
I:
SSR installed on 93 series sockets as a group (without gap between sockets)  
II:
SSR installed individually in free air , or with a gap ≥ 9 mm, which implies a not significant influence from nearby components  
Max recommended switching frequency
(Cycles/Hour, with 50% Duty-cycle) at ambient temperature 50°C, single mounting  
Load  
24 V 6 A DC1  
34.81.7xxx.
9024  
34.81.7xxx.
8240  
34.81.7xxx.
7048  
34.81.7xxx.
7220  
180 000  
5000  
3600  
6500  
9000  
3250  
—
—
—
—
—
—
—
24 V 3 A DC L/R = 10 ms  
24 V 2 A DC L/R = 40 ms  
24 V 1 A DC L/R = 40 ms  
24 V 0.8 A DC L/R = 40 ms  
24 V 1.5 A DC L/R = 80 ms  
230 V 2 A AC1  
—
—
—
—
—
—
—
—
—
—
—
—
60 000  
3600  
—
—
—
230 V 1.25 A AC15  
—
—
—
48 V 0.1 A DC1  
—
60 000  
—
—
220 V 0.2 A DC1  
—
—
60 000  
8

34 SERIES  
Ultra-Slim PCB relays  
34  
SERIES  
Outline drawings  
Type 34.51  
Type 34.81  
A
9

93 SERIES  
34  
Sockets and accessories for 34 series relays  
SERIES  
Screw terminal socket
35 mm rail mounting (EN 60715)  
Common features  
– Space saving 6.2 mm wide  
– Connections for 16-way jumper link  
– Integral coil indication and protection circuit  
– Secure retention and easy ejection by plastic clip  
A
– Dual screw head (blade+cross) terminals  
93.61  
For technical data and supply versions, refer to the Master
INTERFACE
39 Series
– “Relay interface module”  
Electromechanical Relay – EMR  
Socket type
(reference with the 39 Series)  
Master
BASIC  
(39.11…..)  
93.61.7.024  
93.61.7.024  
93.61.7.024  
—
Master
PLUS  
(39.31…..)  
Master
INPUT
Master
OUTPUT
Master
TIMER  
Supply voltage  
Relay type  
(39.41…..)  
93.64.7.024  
93.64.7.024  
93.64.7.024  
—
(39.21…..)  
93.62.7.024  
93.62.7.024  
93.62.7.024  
—
(39.81…..)  
93.62  
6 V AC/DC  
12 V AC/DC  
24 V AC/DC  
60 V AC/DC  
34.51.7.005.xx10  
34.51.7.012.xx10  
34.51.7.024.xx10  
34.51.7.060.xx10  
93.63.7.024  
93.63.7.024  
93.63.7.024  
93.63.7.060  
93.63.3.125  
93.63.3.230  
93.63.0.125  
93.63.0.240  
93.63.8.230  
93.63.7.125  
93.63.7.220  
—
93.68.0.024  
93.68.0.024  
—
—
—
—
—
—
—
—
(110…125)V AC/DC*
 
34.51.7.060.xx10  
—
—
—
(220…240)V AC*  
(110…125)V AC/DC  
(24…240)V AC/DC  
(220…240)V AC  
(110…125)V DC  
220 V DC  
34.51.7.060.xx10  
34.51.7.060.xx10  
34.51.7.024.xx10  
34.51.7.060.xx10  
34.51.7.060.xx10  
34.51.7.060.xx10  
—
—
—
93.61.0.125  
—
93.64.0.125  
—
93.62.0.125  
—
93.61.8.230  
—
93.64.8.230  
—
93.62.8.230  
—
93.63  
93.64  
—
—
—
* Leakage current suppression  
Solid State Relay – SSR  
Socket type
(reference with the 39 Series)  
Master
BASIC  
(39.10…..)  
Master
PLUS  
(39.30…..)  
Master
INPUT
Master
OUTPUT
Master
TIMER  
Supply voltage  
Relay type  
(39.40…..)  
(39.20…..)  
(39.80…..)  
12 V AC/DC  
24 V AC/DC  
34.81.7.012.xxxx  
34.81.7.024.xxxx  
—
—
—
—
93.68.0.024  
—
93.63.0.024  
93.63.3.125  
93.63.3.230  
93.63.0.125  
93.63.0.240  
93.63.8.230  
93.63.7.024  
93.63.7.024  
93.63.7.024  
93.63.7.060  
93.63.7.125  
93.63.7.220  
93.64.0.024  
—
—
93.68.0.024  
(110…125)V AC/DC*
 
34.81.7.060.xxxx  
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
(220…240)V AC*  
(110…125)V AC/DC  
(24…240)V AC/DC  
(220…240)V AC  
6 V DC  
34.81.7.060.xxxx  
34.81.7.060.xxxx  
34.81.7.024.xxxx  
34.81.7.060.xxxx  
34.81.7.005.xxxx  
34.81.7.012.xxxx  
34.81.7.024.xxxx  
34.81.7.060.xxxx  
34.81.7.060.xxxx  
34.81.7.060.xxxx  
—
93.61.0.125  
—
93.64.0.125  
—
93.62.0.125  
—
93.68  
93.61.8.230  
93.61.7.024  
93.61.7.024  
93.61.7.024  
—
93.64.8.230  
93.64.7.024  
93.64.7.024  
93.64.7.024  
—
93.62.8.230  
93.62.7.024  
93.62.7.024  
93.62.7.024  
—
Approvals  
(according to type):  
12 V DC  
24 V DC  
60 V DC  
(110…125)V DC  
220 V DC  
—
—
—
—
—
—
* Leakage current suppression  
Accessories  
16-way jumper link  
Dual-purpose plastic separator  
Sheet of marker tags  
Technical data  
093.16 (blue), 093.16.0 (black), 093.16.1 (red)  
093.60  
060.48 and 093.48  
Rated values  
6 A – 250 V  
Dielectric strength  
Protection category  
Ambient temperature  
Screw torque  
6 kV (1.2/50 μs) between coil and contacts  
IP 20  
°C −40…+70  
Nm 0.5  
mm 10  
Wire strip length  
Max wire size  
Solid wire and stranded wire  
mm

2

1 x (0.5…2.5) / 2 x 1.5  
AWG 1
 
x (21…14) / 2 x 16  
10  

93 SERIES  
34  
Sockets and accessories for 34 series relays  
SERIES  
Push-In terminal socket
35 mm rail mounting (EN 60715)  
Common features  
– Space saving 6.2 mm wide  
– Connections for 16-way jumper link  
– Terminal doubler 093.62  
A
– Integral coil indication and protection circuit  
– Secure retention and easy ejection by plastic clip  
93.60  
For technical data and supply versions, refer to the Master
INTERFACE
39 Series
– “Relay interface module”  
Electromechanical Relay – EMR  
Socket type
(reference with the 39 Series)  
Master
BASIC  
(39.01…..)  
93.60.7.024  
93.60.7.024  
93.60.7.024  
—
Master
PLUS  
(39.61…..)  
Master
INPUT
Master
OUTPUT
Master
TIMER  
Supply voltage  
Relay type  
(39.71…..)  
93.67.7.024  
93.67.7.024  
93.67.7.024  
—
(39.51…..)  
93.65.7.024  
93.65.7.024  
93.65.7.024  
—
(39.91…..)  
93.65  
6 V AC/DC  
12 V AC/DC  
24 V AC/DC  
60 V AC/DC  
34.51.7.005.xx10  
34.51.7.012.xx10  
34.51.7.024.xx10  
34.51.7.060.xx10  
93.66.7.024  
93.66.7.024  
93.66.7.024  
93.66.7.060  
93.66.3.125  
93.66.3.230  
93.66.0.125  
93.66.0.240  
93.66.8.230  
93.66.7.125  
93.66.7.220  
—
93.69.0.024  
93.69.0.024  
—
—
—
—
—
—
—
—
(110…125)V AC/DC*
 
34.51.7.060.xx10  
—
—
—
(220…240)V AC*  
(110…125)V AC/DC  
(24…240)V AC/DC  
(220…240)V AC  
(110…125)V DC  
220 V DC  
34.51.7.060.xx10  
34.51.7.060.xx10  
34.51.7.024.xx10  
34.51.7.060.xx10  
34.51.7.060.xx10  
34.51.7.060.xx10  
—
—
—
93.60.0.125  
—
93.67.0.125  
—
93.65.0.125  
—
93.60.8.230  
—
93.67.8.230  
—
93.65.8.230  
—
93.66  
93.67  
—
—
—
* Leakage current suppression  
Solid State Relay – SSR  
Socket type
(reference with the 39 Series)  
Master
PLUS  
(39.60…..)  
Master
BASIC  
(39.00…..)  
Master
INPUT
Master
OUTPUT
Master
TIMER  
Supply voltage  
Relay type  
(39.70…..)  
(39.50…..)  
(39.90…..)  
12 V AC/DC  
24 V AC/DC  
34.81.7.012.xxxx  
34.81.7.024.xxxx  
—
—
—
—
93.69.0.024  
—
93.66.0.024  
93.66.3.125  
93.66.3.230  
93.66.0.125  
93.66.0.240  
93.66.8.230  
93.66.7.024  
93.66.7.024  
93.66.7.024  
93.66.7.060  
93.66.7.125  
93.66.7.220  
93.67.0.024  
—
—
93.69.0.024  
(110…125)V AC/DC*
 
34.81.7.060.xxxx  
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
(220…240)V AC*  
(110…125)V AC/DC  
(24…240)V AC/DC  
(220…240)V AC  
6 V DC  
34.81.7.060.xxxx  
34.81.7.060.xxxx  
34.81.7.024.xxxx  
34.81.7.060.xxxx  
34.81.7.005.xxxx  
34.81.7.012.xxxx  
34.81.7.024.xxxx  
34.81.7.060.xxxx  
34.81.7.060.xxxx  
34.81.7.060.xxxx  
—
93.60.0.125  
—
93.67.0.125  
—
93.65.0.125  
—
93.60.8.230  
93.60.7.024  
93.60.7.024  
93.60.7.024  
—
93.67.8.230  
93.67.7.024  
93.67.7.024  
93.67.7.024  
—
93.65.8.230  
93.65.7.024  
93.65.7.024  
93.65.7.024  
—
93.69  
12 V DC  
Approvals  
(according to type):  
24 V DC  
60 V DC  
(110…125)V DC  
220 V DC  
—
—
—
—
—
—
* Leakage current suppression  
Accessories  
16-way jumper link  
Dual-purpose plastic separator  
Terminal doubler  
Sheet of marker tags  
Technical data  
093.16 (blue), 093.16.0 (black), 093.16.1 (red)  
093.60  
093.62  
060.48 and 093.48  
Rated values  
6 A – 250 V  
Dielectric strength  
Protection category  
Ambient temperature  
Wire strip length  
Max wire size  
6 kV (1.2/50 μs) between coil and contacts  
IP 20  
°C −40…+70  
mm  
8
Solid wire and stranded wire  
mm

2

1 x (0.5…2.5)  
AWG 1
 
x (21…14)  
11  

93 SERIES  
34  
Sockets and accessories for 34 series relays  
SERIES  
Screw less terminal socket
35 mm rail mounting (EN 60715)  
Common features  
– Space saving 6.2 mm wide  
– Connections for 20-way jumper link  
– Integral coil indication and protection circuit  
– Secure retention and easy ejection by plastic clip  
A
93.51  
For technical data and supply versions, refer to the
38 Series
– “Relay interface module”  
Approvals  
(according to type):  
Electromechanical Relay – EMR and Solid State Relay – SSR  
Relay type
(reference with the 38 Series)  
Electromechnanical relay – EMR  
(38.61…..)  
Solid State Relay – SSR  
(38.81…..)  
Supply voltage  
Socket type  
Certain relay/socket  
combinations  
12 V AC/DC  
24 V AC/DC  
34.51.7.012.xx10  
34.51.7.024.xx10  
34.51.7.060.xx10  
34.51.7.060.xx10  
34.51.7.060.xx10  
34.51.7.060.xx10  
34.51.7.060.xx10  
34.51.7.012.xx10  
34.51.7.024.xx10  
34.51.7.060.xx10  
—
93.51.0.024  
93.51.0.024  
93.51.0.125  
93.51.0.240  
93.51.3.125  
93.51.3.240  
93.51.8.240  
93.51.7.024  
93.51.7.024  
93.51.7.060  
—
(110…125)V AC/DC  
(220…240)V AC/DC  
(110…125)V AC/DC*  
(220…240)V AC*  
(220…240)V AC  
12 V DC  
34.81.7.060.xxxx  
34.81.7.060.xxxx  
34.81.7.060.xxxx  
34.81.7.060.xxxx  
34.81.7.060.xxxx  
34.81.7.012.xxxx  
34.81.7.024.xxxx  
34.81.7.060.xxxx  
24 V DC  
60 V DC  
* Leakage current suppression  
Accessories  
20-way jumper link  
Plastic separator  
093.20  
093.01  
093.48  
Sheet of marker tags  
Technical data  
Rated values  
6 A – 250 V  
Dielectric strength  
Protection category  
Ambient temperature (U

N

≤ 60 V/> 60 V)  
Wire strip length  
6 kV (1.2/50 μs) between coil and contacts  
IP 20  
°C −40…+70/−40…+55  
mm 10  
Max wire size  
Solid wire and stranded wire  
mm

2

1 x 2.5 / 2 x 1.5  
AWG 1
 
x 14 / 2 x 16  
12  

93 SERIES  
34  
Sockets and accessories for 34 series relays  
SERIES  
PCB socket
with retaining and release clip  
For relay type  
93.11 (blue)  
34.51, 34.81  
Technical data  
Rated values  
6 A – 250 V  
A
Dielectric strength  
≥ 6 kV (1.2/50 μs) between coil and contacts  
IP 20  
93.11  
Protection category  
Approvals  
Ambient temperature  
(according to type):  
°C –40…+70  
Retaining and release clip use:  
Please see
general technical information  
13