Finder-Relays–Inc–40-52-7-048-0001

Part #Finder-Relays–Inc–40-52-7-048-0001
Download 
Finder-Relays–Inc–40-52-7-048-0001
40  
SЕRIES  
Miniature PCB Relays  
8 – 10 – 12 – 16 A  
Medical and  
dentistry  
Control panels  
Panels for electrical  
distribution  
Toys  
Automation  
for blinds,  
grilles and  
shutters  
Door and  
gate openers  
Electronic  
circuit boards  
Vending  
machines  

Prices, features, specifications, capabilities, appearance and availability of our products and services are subject to change without notice.  
FINDER assumes no responsibility for the presence of possible errors or insufficient information in this document.  
In case of discrepancies between the printed and online versions, the latter prevails.  

40 SERIES  
PCB/Plug-in relays 8 – 10 – 12 – 16 A  
40  
SERIES  
Power relays 1 and 2 pole for direct
 
PCB or  
socket mount  
40.31/51  
40.52  
40.61  
Type 40.31/51  
– 1
 
CO 12 A (3.5 mm pin pitch)  
– 1
 
CO 12 A (5.0 mm pin pitch)  
A
Type 40.52  
– 2
 
CO 8 A (5.0 mm pin pitch)  
Type 40.61  
– 1
 
CO 16 A (5.0 mm pin pitch)  
•
Pin length 3.5 mm for PCB mount  
•
Pin length 5.3 mm for Plug-in mount  
•
DC coils (650 mW or 500 mW) and AC coils  
•
Cadmium-free contact material available  
•
8 mm Creepage and Clearance, 6 kV (1.2/50µs)  
between coil and contact  
•
1 CO 12 A on PCB, 10 A with  
socket  
•
3.5 mm pin pitch (40.31),  
5.0 mm pin pitch (40.51)  
•
PCB or 95 Series socket mount  
•
2 CO 8 A  
•
5.0 mm pin pitch  
•
PCB or 95 Series socket mount
 
•
PCB or 95 Series socket mount  
•
1 CO 16 A  
•
5.0 mm pin pitch  
•
Meets EN 60335-1 glow wire requirements  
•
95 series sockets for PCB or 35 mm rail  
mounting (EN 60715) with Screw, Screwless or  
Push-in terminals  
•
Coil Indication and EMC suppression modules  
99 series and Timer module 86.30 options  
•
Environmental protection:  
RT II – flux proof (Standard)  
RT III – wash tight (Option)  
40.31  
* Mounted on sockets ≤ 10 A  
** With the AgSnO

2

material the maximum peak  
current on normally open contact, is 120 A – 5 ms  
(for 40.61) and 60 A – 5 ms (for 40.52)  
40.51  
Copper side view  
Copper side view  
Pin length 5.3 mm for PCB or  
sockets  
Copper side view  
F
or
UL
ratings see
:  
“
General technical information
”
page
V
 
Pin length 3.5 mm for PCB only  
Pin length 5.3 mm for PCB or  
sockets  
Pin length 3.5 mm for PCB only  
Pin length 5.3 mm for PCB or  
sockets  
See ordering information  
For outline drawing see page 10  
See ordering information  
See ordering information  
Contact specification  
Contact configuration  
1 CO (SPDT)  
12*/20  
2 CO (DPDT)  
8/15**  
1 CO (SPDT)  
16/30**  
Rated current/Maximum peak current  
A
Rated voltage/  
250/400  
3000  
250/400  
2000  
250/400  
4000  
Maximum switching voltage  
V AC  
VA  
Rated load AC1  
Rated load AC15 (230 V AC)  
Single phase motor rating (230 V AC)  
Breaking capacity DC1: 24/110/220 V  
Minimum switching load  
Standard contact material  
Coil specification  
VA  
1000  
750  
1000  
kW  
A
0.55  
0.37  
0.55  
12/0.6/0.25  
300 (5/5)  
AgNi  
8/0.6/0.25  
300 (5/5)  
AgNi  
16/0.6/0.25  
500 (10/5)  
AgCdO  
mW (V/mA)  
Nominal voltage (U

N

)  
V AC (50/60 Hz)  
V DC  
6 – 12 – 24 – 48 – 60 – 110 – 120 – 230 – 240  
5 – 6 – 7 – 9 – 12 – 14 – 18 – 21 – 24 – 28 – 36 – 48 – 60 – 90 – 110 – 125  
Rated power AC/DC/sensitive DC
 
VA (50 Hz)/W/W  
1.2/0.65/0.5  
1.2/0.65/0.5  
(0.8…1.1)U

N  

1.2/0.65/0.5  
Operating range  
AC  
DC/sensitive DC  
AC/DC  
(0.8…1.1)U

N  

(0.73…1.5)U

N

/(0.73…1.5)U

N  

0.8 U

N

/0.4 U

N  

(0.8…1.1)U

N  

(0.73…1.5)U

N

/(0.8…1.5)U

N  

0.8 U

N

/0.4 U

N  

(0.73…1.5)U

N

/(0.73…1.5)U

N  

0.8 U

N

/0.4 U

N  

Holding voltage  
Must drop-out voltage  
Technical data  
Mechanical life  
AC/DC  
0.2 U

N

/0.1 U

N  

0.2 U

N

/0.1 U

N  

0.2 U

N

/0.1 U

N  

cycles  
cycles  
ms  
10 · 10

6  

200 · 10

3  

10 · 10

6  

100 · 10

3  

10 · 10

6  

100 · 10

3  

Electrical life at rated load AC1  
Operate/release time  
7/3 (10/3 sensitive)  
7/3 (12/4 sensitive)  
7/3 (10/3 sensitive)  
Insulation between coil  
and contacts (1.2/50 µs)  
6 (8 mm)  
6 (8 mm)  
6 (8 mm)  
kV  
Dielectric strength  
1000  
–40…+85  
RT II***  
1000  
–40…+85  
RT II***  
1000  
–40…+85  
RT II***  
between open contacts  
V AC  
°C  
Ambient temperature range  
Environmental protection  
Approvals
(according to type)  
*** See general technical information “Guidelines for automatic flow solder processes
”
p
age
II
.  
3

40 SERIES  
PCB/Plug-in relays 8 – 10 – 12 – 16 A  
40  
SERIES  
Power relays 1 and 2 pole for direct PCB or  
socket mount  
40.62  
40.xx.6  
Type 40.62  
– 2 CO
 
10A (5.0
 
mm pin pitch)  
– DC coils (650 mW or 500 mW) and AC coils  
– Meets EN 60335-1 glow wire requirements  
A
Type 40.xx.6  
– Bistable
 
versions of the types 40.31, 40.51,  
40.52 and 40.61  
– Bistable
 
(single coil)  
•
2 CO 10 A  
•
5.0 mm pin pitch  
•
Bistable (single coil)  
•
Cadmium-free contact material available  
•
8 mm Creepage and Clearance, 6 kV (1.2/50µs)  
between coil and contact  
•
3.5 or 5.0 mm pin pitch  
•
PCB or 95 Series sockets mount
 
•
PCB or 95 Series socket mount  
•
95 series sockets for PCB or 35 mm rail mounting  
(EN 60715) with Screw, Screwless or Push-in  
terminals  
Bistable version (1 coil) types:  
•
Environmental protection:  
40.31.6…  
40.51.6…  
40.52.6…  
40.61.6…  
RT II – flux proof (Standard)  
RT III – wash tight (Option)  
* With the AgSnO

2

material the maximum peak  
current on normally open contact is  
60 A – 5 ms (for 40.62)  
Copper side view  
For wiring diagrams see
 
page 10  
F
or
UL
ratings see
:  
“
General technical information
”
page
V  
Pin length 5.3 mm for  
PCB or sockets  
Pin length 5.3 mm for  
PCB or sockets  
For outline drawing see page 10  
Contact specification  
Contact configuration  
2 CO (DPDT)  
10/20*  
Rated current/Maximum peak current  
A
Rated voltage/  
Maximum switching voltage  
V AC  
250/400  
2500  
See relays  
40.31  
Rated load AC1  
VA  
Rated load AC15 (230 V AC)  
Single phase motor rating (230 V AC)  
Breaking capacity DC1: 24/110/220 V  
Minimum switching load  
Standard contact material  
Coil specification  
VA  
750  
40.51  
kW  
A
0.37  
40.52  
10/0.6/0.25  
300 (5/5)  
AgNi  
40.61  
mW (V/mA)  
page 3  
Nominal voltage (U

N

)  
V AC (50/60 Hz)  
110 – 120 – 230 – 240  
5 – 6 – 12 – 24 – 48 – 110  
5 – 6 – 7 – 9 – 12 – 14 – 18 – 21 – 24  
– 28 – 48 – 60 – 110 – 125  
V DC  
VA (50 Hz)/W/W  
AC  
Rated power AC/DC/sens. DC  
Operating range  
1.2/0.65/0.5  
(0.8…1.1)U

N  

1.0/1.0/—  
(0.8…1.1)U

N  

(0.8…1.1)U

N

/ —  
—
DC/sens. DC  
AC/DC  
(0.73…1.5)U

N

/ (0.73..1.5) U

N  

0.8/0.4 U

N  

Holding voltage  
Must drop-out voltage  
Technical data  
AC/DC  
0.2/0.1 U

N  

—
Mechanical life  
cycles  
cycles  
ms  
10 · 10

6  

100 · 10

3  

See relays  
40.31  
Electrical life at rated load AC1  
Operate/release time  
7/3 (12/4 sensitive)  
40.51  
Insulation between coil  
and contacts (1.2/50 µs)  
kV  
6 (8 mm)  
40.52  
Dielectric strength  
between open contacts  
V AC  
°C  
1000  
–40…+85  
RT II  
40.61  
Min. impulse duration  
≥ 20 ms  
Ambient temperature range  
Environmental protection  
Approvals
(according to type)  
** See general technical information “Guidelines for automatic flow solder processes
”
p
age
II
.  
4

40 SERIES  
PCB/Plug-in relays 8 – 10 – 12 – 16 A  
40  
SERIES  
Ordering information  
Example: 40 series PCB relay, 2 CO, 230 V AC coil.  
A
B
C
D
A
4 0
 
. 5
 
2 . 8 . 2
 
3 0
 
. 0  
0
0
0
Series  
Type  
A:
Contact material  
See table below  
D:
Special versions  
0 = Standard  
3 = PCB/Plug-in – 3.5 mm pinning  
5 = PCB/Plug-in – 5 mm pinning  
6 = PCB/Plug-in – 5 mm pinning  
1 = Wash tight (RT III)  
3 = High temperature (+125 °C) wash  
tight  
B:
Contact circuit  
0 = CO (nPDT)  
3 = NO (nPST)  
No. of poles  
1 = 1 pole  
2 = 2 pole  
C:
Options  
0 = Pin length 5.3 mm (Plug-in relays)  
2 = Pin length 3.5 mm (PCB relays)  
Coil version  
6 = AC/DC bistable  
7 = Sensitive DC, 0.5 W  
8 = AC (50/60 Hz)  
9 = Standard DC, 0.65 W  
Coil voltage  
See coil specifications  
Selecting features and options: only combinations in the same row are possible.  
Preferred selections for best availability are shown in
bold.  
Terminal pin  
Type  
Coil version  
A
B
C
2
2
0
0
0
0
0
0
0
0
0
D
PCB relay,  
pin length 3.5 mm  
40.31/51  
40.61  
Standard DC/sensitive DC  
Standard DC/sensitive DC  
AC/sensitive DC  
Standard DC  
1
(AgNi)  
0
– 3  
0
– 3  
0
– 3  
0
– 3  
0
– 3  
0
– 3  
0
– 3  
0
– 3  
0
0
– 1  
0
– 1  
0
– 1  
0
– 1 – 3  
0
– 1  
0
– 1 – 3  
0
– 1  
0
– 1 – 3  
0
– 1  
0
1 (AgNi) –
2
(AgCdO)  
PCB/Plug-in relay  
pin length 5.3 mm  
40.31/51  
40.31/51  
40.52  
0
(AgNi) – 2 (AgCdO) – 5 (AgNi+Au)  
0
(AgNi) – 2 (AgCdO) – 5 (AgNi+Au)  
0
(AgNi) – 4 (AgSnO

2

) – 5 (AgNi+Au)  
0
(AgNi) – 4 (AgSnO

2

) – 5 (AgNi+Au)  
0
(AgCdO) – 4 (AgSnO

2

)  
0
(AgCdO) – 4 (AgSnO

2

)  
0
(AgNi) – 4 (AgSnO

2

)  
AC/sensitive DC  
Standard DC  
40.52  
40.61  
AC/sensitive DC  
Standard DC  
40.61  
40.62  
AC/DC/sensitive DC  
Bistable  
40.31/51/52  
40.61  
0
(AgNi)  
0
Bistable  
0
(AgCdO)  
0
0
5

40 SERIES  
PCB/Plug-in relays 8 – 10 – 12 – 16 A  
40  
SERIES  
Technical data  
Insulation according to EN 61810-1  
1 pole  
2 pole  
A
Nominal voltage of supply system  
Rated insulation voltage  
Pollution degree  
V AC
 
230/400  
V AC
 
250  
3
230/400  
400  
2
250  
3
400  
2
Insulation between coil and contact set  
Type of insulation  
Reinforced (8 mm)  
Reinforced (8 mm)  
Overvoltage category  
III  
6
III  
Rated impulse voltage  
kV (1.2/50 µs)  
6
Dielectric strength  
V AC
 
4000  
4000  
Insulation between adjacent contacts (40.52)  
Type of insulation  
—
—
—
—
Basic  
II  
Overvoltage category  
Rated impulse voltage  
kV (1.2/50 µs)  
V AC  
2.5  
Dielectric strength  
2000  
Insulation between adjacent contacts (40.52 + 40.62)  
Type of insulation  
—
—
—
—
Basic  
III  
Overvoltage category  
Rated impulse voltage  
kV (1.2/50 µs)  
V AC  
4
Dielectric strength  
2500  
Insulation between open contacts  
Type of disconnection  
Micro-disconnection  
V AC/kV (1.2/50 µs)
 
1000/1.5  
Micro-disconnection  
1000/1.5  
Dielectric strength  
Insulation between coil terminals  
Rated impulse voltage (surge) differential mode  
(according to EN 61000-4-5)  
kV (1.2/50 µs)  
2
Other data  
Bounce time: NO/NC  
ms 2/5  
Vibration resistance (10…150)Hz: NO/NC  
Shock resistance NO/NC  
g
g
20/5 (1 changeover)  
15/4 (2 changeover)  
20/12 (2 changeover)  
20/13 (1 changeover)  
0.65  
Power lost to the environment  
without contact current  
with rated current  
W
W
1.2 (40.31/51)  
2 (40.61/52/62)  
Recommended distance between relays mounted on PCB  
mm ≥
 
5  
6

40 SERIES  
PCB/Plug-in relays 8 – 10 – 12 – 16 A  
40  
SERIES  
Contact specification  
F 40.1 –
 
Electrical life (AC) v contact current  
F 40.2 –
 
Electrical life (AC) v contact current  
Types 40.31/51/61  
Type 40.52  
A
Resistive load – cosφ = 1  
Inductive load AC15  
Resistive load – cosφ = 1  
Inductive load AC15  
Limit for 40.31/51  
F 40.6 – Electrical life (AC) v contact current  
Type 40.62  
Resistive load – cosφ = 1  
Inductive load AC15  
12  
8
7

40 SERIES  
PCB/Plug-in relays 8 – 10 – 12 – 16 A  
40  
SERIES  
Contact specification  
H 40.1 – Maximum DC1 breaking capacity  
H 40.6 – Maximum DC1 breaking capacity  
Types 40.31/51/52/61  
Type 40.62  
A
40.61 current limit  
40.31/51 current limit  
40.52 current limit  
2 contacts in series  
40.52 – 2 contacts in series  
single contact  
single contact  
DC voltage (V)  
DC voltage (V)  
•
When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100 · 10

3

can be expected.  
•
In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load.  
Note: the release time for the load will be increased.  
8

40 SERIES  
PCB/Plug-in relays 8 – 10 – 12 – 16 A  
40  
SERIES  
Coil specifications  
DC coil data – 0.65 W standard
(types 40.31/51/52/61/62)  
DC coil data – 0.5 W sensitive
(types 40.31/51/52/61/62)  
Nominal  
voltage  
U

N  

Coil  
code  
Operating range  
Rated coil  
consumption  
I
at U

N  

Nominal  
voltage  
U

N  

Coil  
code  
Operating range  
Rated coil  
Resistance  
Resistance  
A
consumption  
I
at U

N  

mA  
U

min  

V
U

max  

V
R
U

min  

*
U

max  

V
R
V
mA  
V
V
Ω
Ω
5
6
9
.005  
9
.006  
9
.007  
9
.009  
9
.012  
9
.014  
9
.018  
9
.021  
9
.024  
9
.028  
9
.036  
9
.048  
9
.060  
9
.090  
9
.110  
9
.125  
3.65  
4.4  
7.5  
38  
130  
109  
94  
5
6
7
.005  
7
.006  
7
.007  
7
.009  
7
.012  
7
.014  
7
.018  
7
.021  
7
.024  
7
.028  
7
.036  
7
.048  
7
.060  
7
.090  
7
.110  
7
.125  
3.7  
4.4  
7.5  
9
50  
100  
80  
9
55  
75  
7
5.1  
10.5  
13.5  
18  
75  
7
5.1  
10.5  
13.5  
18  
100  
70  
9
6.6  
125  
220  
300  
500  
700  
900  
1200  
2000  
3500  
5500  
12500  
18000  
23500  
72  
9
6.6  
160  
56  
12  
14  
18  
21  
24  
28  
36  
48  
60  
90  
110  
125  
8.8  
55  
12  
14  
18  
21  
24  
28  
36  
48  
60  
90  
110  
125  
8.8  
288  
42  
10.2  
13.1  
15.3  
17.5  
20.5  
26.3  
35  
21  
47  
10.2  
13.2  
15.4  
17.5  
20.5  
26.3  
35  
21  
400  
35  
27  
36  
27  
650  
27.7  
23.4  
21  
31.5  
36  
30  
31.5  
36  
900  
27  
1150  
1600  
2600  
4800  
7200  
16200  
23500  
32000  
42  
23  
42  
17.5  
13.8  
10  
54  
18  
54  
72  
14  
72  
43.8  
65.7  
80.3  
91.2  
90  
11  
43.8  
65.7  
80.3  
91.2  
90  
8.4  
135  
7.2  
6.2  
5.3  
135  
165  
188  
5.6  
165  
188  
4.7  
3.9  
* U

min

= 0.8 U

N

for 40.61  
AC coil data
(types 40.31/51/52/61/62)  
AC/DC coil data – bistable
(types 40.31/51/52/61)  
Nominal  
voltage  
U

N  

Coil  
code  
Operating range  
Rated coil  
consumption  
Operating range  
Rated coil  
consumption  
Nominal Coil  
voltage code  
Resistance  
DC: Release  
resistance**  
R

DC  

Resistance  
U

min  

V
U

max  

V
R
I
at U

N

(50 Hz)  
mA  
168  
90  
U

N  

V
U

min  

V
U

max  

V
R
I
at U

N  

mA  
215  
165  
83  
V
Ω
Ω
Ω
37  
6
8
.006  
8
.012  
8
.024  
8
.048  
8
.060  
8
.110  
8
.120  
8
.230  
8
.240  
4.8  
6.6  
21  
5
6
6
.005  
6
.006  
6
.012  
6
.024  
6
.048  
6
.110  
4
5.5  
23  
12  
9.6  
19.2  
38.4  
48  
13.2  
26.4  
52.8  
66  
80  
4.8  
6.6  
33  
62  
24  
320  
1350  
2100  
6900  
9000  
28000  
31500  
45  
12  
24  
48  
110  
9.6  
19.2  
38.4  
88  
13.2  
26.4  
52.8  
121  
130  
520  
2100  
11000  
220  
48  
21  
40  
910  
60  
16.8  
9.4  
8.4  
5
21  
3,600  
16,500  
110  
120  
230  
240  
88  
121  
10  
96  
132  
253  
264  
** R

DC

=
Resistance in DC, R

AC

= 1.3 x R

DC

1 W  
184  
192  
4.1  
9

40 SERIES  
PCB/Plug-in relays 8 – 10 – 12 – 16 A  
40  
SERIES  
Coil specifications  
R 40 – DC coil operating range v ambient temperature  
R 40 – DC coil operating range v ambient temperature  
Standard coil  
Sensitive coil, types 40.31/51/52/61/62  
A
40.61  
40.31/51/52/62  
R 40 – AC coil operating range v ambient temperature  
1 –
Max. permitted coil voltage.  
2 –
Min. pick-up voltage with coil at ambient temperature.  
Wiring diagram for 40 series bistable coil version  
AC Operation  
DC Operation  
On momentary closure of the SET switch the relay is magnetised through
 
On momentary closure of the SET switch the relay is magnetised and the  
the diode and the relay contacts transfer to the set position and remain in
 
relay contacts transfer to the set position and remain in this position.  
this position.  
On momentary closure of the RESET switch the relay is demagnetised  
On momentary closure of the RESET switch the relay is demagnetised
 
through limiting resistor (R

DC

) and the contacts return to the reset position.  
through limiting resistor (R

AC

) and the contacts return to the reset position.  
Notes:
The minimum SET or RESET impulse time is 20 ms. The maximum time can be continuous. In practice, always ensure that the SET and RESET  
contacts cannot be operated simultaneously.  
Outline drawings  
Types 40.31/51/52/61/62  
* (3.5 or 5.3 mm) see ordering code  
10  

95 SERIES  
Socket overview for 40 series relays  
40  
SERIES  
Module Socket
 
Relay  
Description  
Mounting  
Accessories  
99.02  
95.P3  
95.P5  
40.31  
Push-in terminal sockets  
–
For fast cable connection  
–
Top terminals – Contacts  
–
Bottom terminals – Coil  
Panel or 35 mm rail  
(EN 60715) mount  
–
Coil indication and EMC  
suppression modules  
–
Jumper link  
40.51  
40.52  
40.61  
40.62  
A
–
Timer modules  
95.P5  
–
Plastic retaining and release  
clip  
See page 12  
Module Socket
 
Relay  
Description  
Mounting  
Accessories  
99.02  
95.03  
95.05  
40.31  
Screw terminal (Box clamp) socket
 
Panel or 35 mm rail  
–
Coil indication and EMC  
suppression modules  
–
Jumper link  
–
Top terminals – Contacts  
(EN 60715) mount  
40.51  
40.52  
40.61  
40.62  
–
Bottom terminals – Coil  
–
Timer modules  
95.05  
–
Plastic retaining and release  
clip  
See page 14  
Module Socket
 
Relay  
Description  
Mounting  
Accessories  
99.80 95.83.3
 
40.31  
Screw terminal (Box clamp) socket
 
Panel or 35 mm rail  
–
Coil indication and EMC  
suppression modules  
–
Jumper link  
–
Plastic retaining and release  
clip  
–
Top terminals – NO and COM  
Contacts  
(EN 60715) mount  
95.85.3
40.51  
40.52  
–
Bottom terminals – Coil and NC  
Contacts  
40.61  
40.62  
95.85.3  
See page 15  
Module Socket
 
Relay  
Description  
Mounting  
Accessories  
99.80 95.93.3
 
40.31  
Screw terminal (Box clamp) socket
 
Panel or 35 mm rail  
–
Coil indication and EMC  
suppression modules  
–
Jumper link  
–
Plastic retaining and release  
clip  
–
Top terminals – Contacts  
(EN 60715) mount  
95.95.3
40.51  
40.52  
–
Bottom terminals – Coil  
40.61  
40.62  
95.95.3  
See page 16  
Module Socket
 
Relay  
Description  
Mounting  
Accessories  
99.01 95.63  
95.65  
40.31  
Screw terminal (Box clamp) socket
 
Panel or 35 mm rail  
–
Metal retaining clip  
–
Top terminals – Contacts  
(EN 60715) mount  
40.51  
40.52  
40.61  
40.62  
–
Bottom terminals – Coil  
95.65  
See page 17  
Module Socket
 
Relay  
Description  
PCB socket  
Mounting  
Accessories  
—
—
95.13.2
40.31  
PCB mounting  
–
Metal retaining clip  
–
Plastic retaining clip  
95.13.2  
95.15.2
40.51  
40.52  
See page 18  
40.61  
40.62  
11  

95 SERIES  
40  
Socket and accessories for 40 series relays  
SERIES  
Push-in terminals socket
panel or 35 mm rail mount  
For relay type  
95.P3  
40.31  
95.P5  
40.51, 40.52, 40.61, 40.62  
Accessories  
Metal retaining clip  
095.71  
A
Plastic retaining and release clip  
(supplied with socket – packaging code SPA)  
8-way jumper link  
095.91.3  
097.58  
097.52  
097.42  
097.00  
095.00.4  
99.02  
95.P5  
Approvals  
(according to type):  
2-way jumper link (12.5 mm pitch)  
2-way jumper link (4.6 mm pitch)  
Marker tag holder (for tags 060.48 type)  
Identification tag  
Modules (see table below)  
Timer modules (see table below)  
Sheet of marker tags for plastic retaining and release clip  
095.91.3 and for marker tag holder 097.00, 48 tags,  
6 x 12 mm, for CEMBRE thermal transfert printer  
Technical data  
86.30  
060.48  
Rated values  
10 A – 250 V*  
6 kV  
095.91.3  
Dielectric strength between coil and contacts (1.2/50 μs)  
Protection category  
IP 20  
Ambient temperature  
°C –40…+70
 
(see diagram L95)  
mm 10  
Wire strip length  
Min. wire size for 95.P3 and 95.P5 sockets  
solid wire  
mm

2

0.5  
stranded wire  
0.5  
AWG 21  
21  
060.48  
Max. wire size for 95.P3 and 95.P5 sockets  
solid wire  
mm

2

2 x 1.5 / 1 x 2.5  
stranded wire  
2 x 1.5 / 1 x 2.5  
2 x 16 / 1 x 14  
AWG 2
 
x 16 / 1 x 14  
* For currents > 10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12).  
With the relay 40.51 the change-over contact will be 21-12-14.  
L 95 – Total socket current v ambient temperature  
11  
COM  
NO  
14  
12  
NC  
A2  
A1  
COIL  
95.P3  
95.P5  
8-way jumper link
for 95.P3 and 95.P5 sockets  
097.58  
Rated values  
10 A – 250 V  
097.58  
097.52  
2-way jumper link
for 95.P3 and 95.P5 sockets  
Rated values  
097.52  
10 A – 250 V  
12  

95 SERIES  
40  
Socket and accessories for 40 series relays  
SERIES  
2-way jumper link
for 95.P3 and 95.P5 sockets  
097.42  
Rated values  
10 A – 250 V  
A
097.42  
Marker tag holder
for 95.P3 and 95.P5 sockets  
097.00  
097.00  
86 series timer modules  
(12…24)V AC/DC; Bi-function: AI, DI; (0.05 s…100 h)  
(110…125)V AC; Bi-function: AI, DI; (0.05 s…100 h)  
(230…240)V AC; Bi-function: AI, DI; (0.05 s…100 h)  
86.30.0.024.0000  
86.30.8.120.0000  
86.30.8.240.0000  
Approvals (according to type):  
99.02 coil indication and EMC suppression modules
for 95.P3 and 95.P5 sockets  
86.30  
Diode (+A1, standard polarity)  
(6…220)V DC
 
99.02.3.000.00  
LED  
(6…24)V DC/AC
 
99.02.0.024.59  
(28…60)V DC/AC
 
99.02.0.060.59  
(110…240)V DC/AC
 
99.02.0.230.59  
(6…24)V DC
 
99.02.9.024.99  
LED  
LED  
LED + Diode (+A1, standard polarity)  
LED + Diode (+A1, standard polarity)  
LED + Diode (+A1, standard polarity)  
LED + Varistor  
99.02  
Approvals  
(according to type):  
(28…60)V DC
 
99.02.9.060.99  
(110…220)V DC
 
99.02.9.220.99  
(6…24)V DC/AC
 
99.02.0.024.98  
(28…60)V DC/AC
 
99.02.0.060.98  
(110…240)V DC/AC
 
99.02.0.230.98  
(6…24)V DC/AC
 
99.02.0.024.09  
(28…60)V DC/AC
 
99.02.0.060.09  
(110…240)V DC/AC
 
99.02.0.230.09  
(110…240)V AC
 
99.02.8.230.07  
LED + Varistor  
LED + Varistor  
DC Modules with  
non-standard polarity  
(+A2) on request.  
RC circuit  
RC circuit  
RC circuit  
Residual current by-pass*  
* Additional 0.9 W power dissipation  
13  

95 SERIES  
40  
Socket and accessories for 40 series relays  
SERIES  
Screw terminal (Box clamp) socket
panel or 35 mm rail mount
 
95.03 (blue)
 
95.03.0 (black)
 
95.05 (blue)
 
95.05.0 (black)  
For relay type  
40.31  
40.51, 40.52, 40.61, 40.62  
Accessories  
Metal retaining clip  
095.71  
A
Plastic retaining and release clip  
(supplied with socket – packaging code SPA)  
095.01  
095.18  
095.01.0  
095.18.0  
095.01  
095.18  
097.00  
095.01.0  
095.18.0  
95.05  
8-way jumper link  
Approvals  
(according to type):  
Marker tag holder (for tags 060.48 type)  
Identification tag  
095.00.4  
99.02  
Modules (see table below)  
Timer modules (see table below)  
86.30  
Sheet of marker tags for plastic retaining and release clip  
095.01 and for marker tag holder 097.00, 48 tags, 6 x 12 mm,  
for CEMBRE thermal transfer printers  
Certain relay/socket  
combinations  
060.48  
Technical data  
Rated values  
10 A – 250 V*  
6 kV  
Dielectric strength between coil and contacts (1.2/50 μs)  
Protection category  
IP 20  
Ambient temperature  
Screw torque  
°C –40…+70
 
(see diagram L95)  
Nm 0.5  
095.01  
Wire strip length  
mm  
8
Max. wire size for 95.03 and 95.05 sockets  
solid wire  
mm

2

1 x 6 / 2 x 2.5  
stranded wire  
1 x 4 / 2 x 2.5  
1 x 12 / 2 x 14  
AWG 1
 
x 10 / 2 x 14  
060.48  
* For currents > 10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12).  
With the relay 40.51 the change-over contact will be 21-12-14.  
L 95 – Total socket current v ambient temperature  
11  
COM  
NO  
14  
12  
NC  
A2  
A1  
COIL  
95.03  
95.05  
8-way jumper link
for 95.03 and 95.05 sockets  
Rated values  
095.18 (blue)  
10 A – 250 V  
095.18.0 (black)  
E
095.18  
86 series timer modules  
(12…24)V AC/DC; Bi-function: AI, DI; (0.05 s…100 h)  
(110…125)V AC; Bi-function: AI, DI; (0.05 s…100 h)  
(230…240)V AC; Bi-function: AI, DI; (0.05 s…100 h)  
86.30.0.024.0000  
86.30.8.120.0000  
86.30.8.240.0000  
86.30  
Approvals (according to type):  
99.02 coil indication and EMC suppression modules
for 95.03 and 95.05 sockets  
Diode (+A1, standard polarity)  
(6…220)V DC
 
99.02.3.000.00  
LED  
LED  
LED  
(6…24)V DC/AC
 
99.02.0.024.59  
(28…60)V DC/AC
 
99.02.0.060.59  
(110…240)V DC/AC
 
99.02.0.230.59  
(6…24)V DC
 
99.02.9.024.99  
LED + Diode (+A1, standard polarity)  
LED + Diode (+A1, standard polarity)  
LED + Diode (+A1, standard polarity)  
LED + Varistor  
LED + Varistor  
LED + Varistor  
RC circuit  
RC circuit  
RC circuit  
Residual current by-pass*  
* Additional 0.9 W power dissipation  
99.02  
(28…60)V DC
 
99.02.9.060.99  
Approvals  
(according to type):  
(110…220)V DC
 
99.02.9.220.99  
(6…24)V DC/AC
 
99.02.0.024.98  
(28…60)V DC/AC
 
99.02.0.060.98  
(110…240)V DC/AC
 
99.02.0.230.98  
(6…24)V DC/AC
 
99.02.0.024.09  
(28…60)V DC/AC
 
99.02.0.060.09  
(110…240)V DC/AC
 
99.02.0.230.09  
(110…240)V AC
 
99.02.8.230.07  
DC Modules with  
non-standard polarity  
(+A2) on request.  
14  

95 SERIES  
40  
Socket and accessories for 40 series relays  
SERIES  
Screw terminal (Box clamp) socket panel
or 35 mm rail mount
 
95.83.3 (blue)
 
95.83.30 (black)
 
95.85.3 (blue)
 
95.85.30 (black)  
For relay type  
40.31  
40.51, 40.52, 40.61, 40.62  
Accessories  
Metal retaining clip  
095.71  
A
Plastic retaining and release clip  
(supplied with socket – packaging code SPA)  
8-way jumper link  
095.91.3  
095.08  
095.91.30  
095.08.0  
095.91.3  
095.08  
095.00.4  
095.91.30  
095.08.0  
95.85.3  
Identification tag  
Approvals  
Modules (see table below)  
Marker tag holder  
99.80  
(according to type):  
097.00  
Sheet of marker tags for plastic retaining and release clip  
095.91.3, 48 tags, 6 x 12 mm, for CEMBRE thermal transfert  
printer  
060.48  
Technical data  
Rated values  
10 A – 250 V*  
6 kV  
095.91.3  
Dielectric strength between coil and contacts (1.2/50 μs)  
Protection category  
2 kV  
IP 20  
Ambient temperature  
°C –40…+70
 
(see diagram L95)  
Screw torque  
Nm 0.5  
Wire strip length  
mm  
7
Max. wire size for 95.83.3 and 95.85.3 sockets  
solid wire  
mm

2

1 x 6 / 2 x 2.5  
stranded wire  
1 x 4 / 2 x 2.5  
1 x 12 / 2 x 14  
060.48  
AWG 1
 
x 10 / 2 x 14  
* For currents > 10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12).  
With the relay 40.51 the change-over contact will be 21-12-14.  
L 95 – Total socket current v ambient temperature  
95.83.3  
95.85.3  
8-way jumper link
for 95.83.3 and 95.85.3 sockets  
Rated values  
095.08 (blue)  
10 A – 250 V  
095.08.0 (black)  
E
095.08  
99.80 coil indication and EMC suppression modules
for 95.83.3 and 95.85.3 sockets  
Blue*  
Diode (+A1, standard polarity)  
(6…220)V DC
 
99.80.3.000.00  
LED  
(6…24)V DC/AC
 
99.80.0.024.59  
(28…60)V DC/AC
 
99.80.0.060.59  
(110…240)V DC/AC
 
99.80.0.230.59  
(6…24)V DC
 
99.80.9.024.99  
LED  
LED  
99.80  
LED + Diode (+A1, standard polarity)  
LED + Diode (+A1, standard polarity)  
LED + Diode (+A1, standard polarity)  
LED + Varistor  
Approvals  
(according to type):  
(28…60)V DC
 
99.80.9.060.99  
(110…220)V DC
 
99.80.9.220.99  
(6…24)V DC/AC
 
99.80.0.024.98  
(28…60)V DC/AC
 
99.80.0.060.98  
(110…240)V DC/AC
 
99.80.0.230.98  
(6…24)V DC/AC
 
99.80.0.024.09  
(28…60)V DC/AC
 
99.80.0.060.09  
(110…240)V DC/AC
 
99.80.0.230.09  
(110…240)V AC
 
99.80.8.230.07  
LED + Varistor  
* Modules in Black  
housing are available  
on request.  
LED + Varistor  
RC circuit  
RC circuit  
Green LED is standard.  
Red LED available on  
request.  
RC circuit  
Residual current by-pass*  
* Additional 0.9 W power dissipation  
15  

95 SERIES  
40  
Socket and accessories for 40 series relays  
SERIES  
Screw (Box clamp) terminal socket
panel or 35 mm rail mount
 
95.93.3 (blue)
 
95.93.30 (black)
 
95.95.3 (blue)
 
95.95.30 (black)  
For relay type  
40.31  
40.51, 40.52, 40.61, 40.62  
Accessories  
Metal retaining clip  
095.71  
A
Plastic retaining and release clip  
(supplied with socket – packaging code SPA)  
8-way jumper link  
095.91.3  
095.08  
095.91.30  
095.08.0  
095.91.3  
095.08  
095.00.4  
095.91.30  
095.08.0  
95.95.3  
Identification tag  
Approvals  
(according to type):  
Modules (see table below)  
Sheet of marker tags for plastic retaining and release clip  
095.91.3 and for marker tag holder 097.00
, 48 tags,  
6 x 12 mm, for CEMBRE thermal transfer printers  
Technical data  
99.80  
060.48  
Rated values  
10 A – 250 V*  
6 kV  
Dielectric strength between coil and contacts (1.2/50 μs)  
Protection category  
IP 20  
095.91.3  
Ambient temperature  
°C –40…+70
 
(see diagram L95)  
Screw torque  
Nm 0.5  
Wire strip length  
mm  
8
Max. wire size for 95.93.3 and 95.95.3 sockets  
solid wire  
mm

2

1 x 6 / 2 x 2.5  
stranded wire  
1 x 4 / 2 x 2.5  
1 x 12 / 2 x 14  
AWG 1
 
x 10 / 2 x 14  
060.48  
* For currents > 10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12).  
With the relay 40.51 the change-over contact will be 21-12-14.  
L 95 – Total socket current v ambient temperature  
95.93.3  
95.95.3  
8-way jumper link
for 95.93.3 and 95.95.3 sockets  
Rated values  
095.08 (blue)  
10 A – 250 V  
095.08.0 (black)  
E
095.08  
99.80 coil indication and EMC suppression modules
for 95.93.3 and 95.95.3 sockets  
Blue*  
Diode (+A1, standard polarity)  
(6…220)V DC
 
99.80.3.000.00  
LED  
(6…24)V DC/AC
 
99.80.0.024.59  
(28…60)V DC/AC
 
99.80.0.060.59  
(110…240)V DC/AC
 
99.80.0.230.59  
(6…24)V DC
 
99.80.9.024.99  
LED  
LED  
99.80  
LED + Diode (+A1, standard polarity)  
LED + Diode (+A1, standard polarity)  
LED + Diode (+A1, standard polarity)  
LED + Varistor  
Approvals  
(according to type):  
(28…60)V DC
 
99.80.9.060.99  
(110…220)V DC
 
99.80.9.220.99  
(6…24)V DC/AC
 
99.80.0.024.98  
(28…60)V DC/AC
 
99.80.0.060.98  
(110…240)V DC/AC
 
99.80.0.230.98  
(6…24)V DC/AC
 
99.80.0.024.09  
(28…60)V DC/AC
 
99.80.0.060.09  
(110…240)V DC/AC
 
99.80.0.230.09  
(110…240)V AC
 
99.80.8.230.07  
LED + Varistor  
* Modules in Black  
housing are available  
on request.  
LED + Varistor  
RC circuit  
RC circuit  
Green LED is standard.  
Red LED available on  
request.  
RC circuit  
Residual current by-pass*  
* Additional 0.9 W power dissipation  
16  

95 SERIES  
40  
Socket and accessories for 40 series relays  
SERIES  
Screw terminal (Box clamp) socket
panel or 35 mm rail mount
 
95.63  
95.65  
For relay type  
40.31  
40.51, 40.52, 40.61, 40.62  
Accessories  
Metal retaining clip  
095.71  
A
8-way jumper link  
095.08  
99.01  
095.08  
—
95.63  
Modules (see table below)  
Technical data  
Approvals  
(according to type):  
Rated values  
10 A – 250 V*  
Dielectric strength between coil and contacts (1.2/50 μs)  
Protection category  
6 kV  
2 kV  
IP 20  
Ambient temperature  
Screw torque  
°C –40…+70
 
(see diagram L95)  
Nm 0.5  
Wire strip length  
mm  
7
Max. wire size for 95.63 and 95.65 sockets  
solid wire  
stranded wire  
1 x 4 / 2 x 2.5  
1 x 12 / 2 x 14  
mm

2

1 x 6 / 2 x 2.5  
AWG 1
 
x 10 / 2 x 14  
95.65  
* For currents > 10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12).  
With the relay 40.51 the change-over contact will be 21-12-14.  
Approvals  
(according to type):  
L 95 – Total socket current v ambient temperature  
95.63  
95.65  
8-way jumper link
for 95.63 and 95.65 sockets  
Rated values  
095.08 (blue)  
10 A – 250 V  
E
095.08  
99.01 coil indication and EMC suppression modules
for type 95.63 socket  
Blue*  
Diode (+A1, standard polarity)  
Diode (+A2, non-standard polarity)  
LED  
(6…220)V DC
 
99.01.3.000.00  
(6…220)V DC
 
99.01.2.000.00  
(6…24)V DC/AC
 
99.01.0.024.59  
(28…60)V DC/AC
 
99.01.0.060.59  
(110…240)V DC/AC
 
99.01.0.230.59  
(6…24)V DC
 
99.01.9.024.99  
LED  
99.01  
LED  
Approvals  
(according to type):  
LED + Diode (+A1, standard polarity)  
LED + Diode (+A1, standard polarity)  
LED + Diode (+A1, standard polarity)  
LED + Diode (+A2, non-standard polarity)  
LED + Diode (+A2, non-standard polarity)  
LED + Diode (+A2, non-standard polarity)  
LED + Varistor  
(28…60)V DC
 
99.01.9.060.99  
(110…220)V DC
 
99.01.9.220.99  
(6…24)V DC
 
99.01.9.024.79  
* Modules in Black  
housing are available  
on request.  
(28…60)V DC
 
99.01.9.060.79  
(110…220)V DC
 
99.01.9.220.79  
(6…24)V DC/AC
 
99.01.0.024.98  
(28…60)V DC/AC
 
99.01.0.060.98  
(110…240)V DC/AC
 
99.01.0.230.98  
(6…24)V DC/AC
 
99.01.0.024.09  
(28…60)V DC/AC
 
99.01.0.060.09  
(110…240)V DC/AC
 
99.01.0.230.09  
(110…240)V AC
 
99.01.8.230.07  
Green LED is standard.  
Red LED available on  
request.  
LED + Varistor  
LED + Varistor  
RC circuit  
RC circuit  
RC circuit  
Residual current by-pass*  
* Additional 0.9 W power dissipation  
17  

95 SERIES  
40  
Socket and accessories for 40 series relays  
SERIES  
PCB socket  
For relay type  
Accessories  
95.13.2 (blue)
 
95.13.20 (black)
 
95.15.2 (blue)
 
95.15.20 (black)  
40.31  
40.51, 40.52, 40.61, 40.62  
Metal retaining clip (supplied with socket –  
packaging code SMA)  
A
95.13.2  
095.51  
095.52  
Plastic retaining clip  
Technical data  
Rated values  
12 A – 250 V  
10 A – 250 V*  
Dielectric strength between coil and contacts (1.2/50 μs)
 
6 kV  
95.15.2  
Protection category  
IP 20  
Ambient temperature  
°C –40…+70  
Approvals  
(according to type):  
* For currents > 10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12).  
With the relay 40.51 the change-over contact will be 21-12-14.  
40.31  
40.51  
13  
7.5  
12 14 22 24  
A1  
A2  
12 11 14  
11  
A1  
21  
A2  
22  
21  
24  
40.52  
95.13.2  
95.15.2  
Copper side view  
Copper side view  
40.61  
Packaging codes  
How to code and identify retaining clip and packaging options for sockets.  
Example:  
9 5
 
. P  
5
S P  
A
A
Standard packaging  
SM
Metal retaining clip  
SP
Plastic retaining clip  
Please see
general technical information  
18