Finder-Relays–Inc–45-71-7-024-0310

Part #Finder-Relays–Inc–45-71-7-024-0310
Download 
Finder-Relays–Inc–45-71-7-024-0310
45  
SЕRIES  
Miniature PCB Relays  
+ Faston 250  
10 – 16 A  
Burners, boilers and  
furnaces  
Jacuzzis and hot  
tubs  
Infrared and  
microwave  
ovens  
Film  
projectors  
Electronic  
circuit  
boards  
Control and  
management  
of electric  
power  
Inverter  
Charging  
Stations  

Prices, features, specifications, capabilities, appearance and availability of our products and services are subject to change without notice.  
FINDER assumes no responsibility for the presence of possible errors or insufficient information in this document.  
In case of discrepancies between the printed and online versions, the latter prevails.  

45 SERIES  
Miniature PCB relays 10 – 16 A  
45  
SERIES  
Relay for +105 °C ambient use  
PCB mount – high contact gap for photovoltaic  
inverters and charging station  
PCB mount  
45.31…x310  
45.31…4310  
45.31…0610  
A
– 45.31…x310, 1 Pole normally open  
(≥ 3 mm contact gap)  
– 45.31…4310, Conform to Annex CC  
EN 61439-7:2018 for ev charging station  
– 45.31…0610, 1 Pole normally open  
(≥ 3.6 mm contact gap)  
•
1 NO (SPST-NO), ≥ 3 mm gap  
•
Max ambient temperature  
+105 °C  
•
PCB mounting  
•
1 NO (SPST-NO), ≥ 3 mm gap  
•
Conform to Annex CC  
EN 61439-7:2018 for ev  
charging station  
•
Max ambient temperature  
+105 °C  
•
1 NO (SPST-NO), ≥ 3.6 mm gap  
•
Max ambient temperature  
+105 °C  
•
PCB mounting  
•
Contact gap ≥ 3 mm or ≥ 3.6 mm according to  
EN 60730-1  
•
Sensitive DC coil – 360 mW (45.31…x310 type)  
•
Cadmium Free contact material  
•
Reinforced insulation between coil and  
contacts according to EN 60335-1, EN 50178,  
EN 60204 with safe separation and 8 mm  
clearance and creepage distance  
•
6 kV (1.2/50 µs) isolation, coil-contacts  
•
Flux proof: RT II  
•
PCB mounting  
45.31…x310  
(1 NO/SPST-NO)  
45.31…4310  
(1 NO)  
45.31…0610  
(1 NO/SPST-NO)  
F
or
UL
ratings see
:  
“
General technical information
”
page
V
 
Copper side view  
Copper side view  
Copper side view  
For outline drawing see page 7  
Contact specification  
Contact configuration  
1NO (SPST-NO) ≥ 3 mm gap  
16/30  
1NO (SPST-NO) ≥ 3 mm gap  
16/80  
1NO (SPST-NO) ≥ 3.6 mm gap  
10/30  
Rated current/Maximum peak current (@105°C)  
A
Maximum switching current/Maximum peak  
current (@85°C)  
A
—
20/80  
—
Rated voltage/  
Maximum switching voltage  
V AC  
VA  
250/400  
4000  
—
250/400  
4000  
500/500  
5000  
—
Rated load AC1  
Peak current conform to Annex CC EN 61439-7:2018
 
A  
Peak current conform to IEC60669-2-1 A2:2015
 
A  
230 (70 μs)  
120 (600 μs)  
125  
—
—
LED lamps rating (230 V)  
W
—
—
Rated load AC15 (230 V AC)  
Single phase motor rating (230 V AC)  
Breaking capacity DC1: 24/110/220 V  
Minimum switching load  
VA  
750  
—
750  
kW  
A
0.55  
—
0.55  
16/4/1  
500 (10/5)  
AgNi  
16/4/1  
500 (10/5)  
AgSnO

2  

10/4/1  
500 (10/5)  
AgNi  
mW (V/mA)  
Standard contact material  
Coil specification  
Nominal voltage (U

N

)  
V AC (50/60 Hz)  
V DC  
—
6 – 12 – 24 – 48 – 60  
—/0.36  
—
6 – 12 – 24 – 48 – 60  
—/0.36  
—
6 – 12 – 24 – 48 – 60  
—/0.55  
Rated power AC/DC  
Operating range  
VA (50 Hz)/W  
AC  
—
—
—
DC  
(0.7…1.2)U

N  

—/0.4 U

N  

—/0.1 U

N  

(0.7…1.2)U

N  

—/0.4 U

N  

—/0.1 U

N  

(0.8…1.2)U

N  

—/0.4 U

N  

—/0.1 U

N  

Holding voltage  
AC/DC  
Must drop-out voltage  
Technical data  
AC/DC  
Mechanical life AC/DC  
Electrical life at rated load AC1  
Operate/release time  
cycles  
cycles  
ms  
—/10 · 10

6  

30 · 10

3  

12/2  
—/10 · 10

6  

20 · 10

3  

12/2  
—/2 · 10

6  

10 · 10

3  

12/2  
Insulation between coil  
and contacts (1.2/50 µs)  
kV  
6 (8 mm)  
6 (8 mm)  
6 (8 mm)  
Dielectric strength  
between open contacts  
V AC  
°C  
2500  
–40…+105  
RT II  
2500  
–40…+105  
RT II  
3000  
–40…+105  
RT II  
Ambient temperature range  
Environmental protection  
Approvals
(according to type)  
3

45 SERIES  
Miniature PCB relays 16 A  
45  
SERIES  
Relays for +125 °C ambient use  
PCB mount – Faston 250 contact connections  
45.71  
45.91  
– 45.71, 1 Pole normally open or normally  
closed  
– 45.91, 1 Pole normally open  
(≥ 3 mm contact gap)  
A
•
Contact gap ≥ 3 mm according to EN 60730-1  
(45.91 type)  
•
Sensitive DC coil – 360 mW  
•
Cadmium Free option available  
•
Reinforced insulation between coil and  
contacts according to EN 60335-1, EN 50178,  
EN 60204 with safe separation and 8 mm  
clearance and creepage distance  
•
6 kV (1.2/50 µs) isolation, coil-contacts  
•
Flux proof: RT II standard, (RT III option)  
•
1 NO or 1 NC  
•
1 NO (SPST-NO),  
(SPST-NO or SPST-NC)  
•
Max ambient temperature  
+125 °C  
≥ 3 mm gap  
•
Max ambient temperature  
+125 °C  
•
PCB mounting + Faston 250  
•
PCB mounting + Faston 250  
45.71…0310  
(1 NO)/(SPST-NO)  
45.91…0310  
(1 NO/SPST-NO)  
45.71…0410  
(1 NC)/(SPST-NC)  
F
or
UL
ratings see
:  
“
General technical information
”
page
V  
Copper side view  
Copper side view  
For outline drawing see page 7  
Contact specification  
Contact configuration  
1NO or 1NC (SPST-NO or SPST-NC)  
A 16/30  
1NO (SPST-NO) ≥ 3 mm gap  
16/30  
Rated current/Maximum peak current  
Rated voltage/  
Maximum switching voltage  
V AC  
250/400  
4000  
250/400  
4000  
Rated load AC1  
VA  
Rated load AC15 (230 V AC)  
Single phase motor rating (230 V AC)  
Breaking capacity DC1: 24/110/220 V  
Minimum switching load  
Standard contact material  
Coil specification  
VA  
750  
750  
kW  
A
0.55  
0.55  
16/0.3/0.13  
500 (10/5)  
AgCdO  
16/4/1  
500 (10/5)  
AgNi  
mW (V/mA)  
Nominal voltage (U

N

)  
V AC (50/60 Hz)  
V DC  
—
6 – 12 – 24 – 48 – 60  
—/0.36  
—
6 – 12 – 24 – 48 – 60  
—/0.36  
Rated power AC/DC  
Operating range  
VA (50 Hz)/W  
AC  
—
—
DC  
(0.7…1.2)U

N  

—/0.4 U

N  

—/0.1 U

N  

(0.7…1.2)U

N  

—/0.4 U

N  

—/0.1 U

N  

Holding voltage  
AC/DC  
Must drop-out voltage  
Technical data  
AC/DC  
Mechanical life AC/DC  
Electrical life at rated load AC1  
Operate/release time  
cycles  
cycles  
ms  
—/10 · 10

6  

100 · 10

3  

10/2  
—/10 · 10

6  

30 · 10

3  

12/2  
Insulation between coil  
and contacts (1.2/50 µs)  
kV  
6 (8 mm)  
6 (8 mm)  
Dielectric strength  
between open contacts  
V AC  
°C  
1000  
–40…+125  
RT II  
2500  
–40…+125  
RT II  
Ambient temperature range  
Environmental protection  
Approvals
(according to type)  
4

45 SERIES  
Miniature PCB relays 10 – 16 A  
45  
SERIES  
Ordering information  
Example: 45 series for PCB relay + Faston 250, 1 NO (SPST-NO), 12 V DC coil.  
A
B
C
D
A
4 5
 
. 7
 
1 . 7 . 0
 
1 2
 
. 0
 
3 1 0  
Series  
A:
Contact material  
0 = Standard AgCdO  
for 45.71,  
Standard AgNi  
for 45.31 and 45.91  
1 = AgNi  
D:
Special versions  
0 = Flux proof (RT II)  
1 = Wash tight (RT III) 45.71  
and 45.91 only  
Type  
3 = PCB mount, ≥ 3 mm or ≥ 3.6 mm  
contact gap  
7 = PCB + Faston 250 mount  
9 = PCB + Faston 250 mount, ≥ 3 mm  
C:
Options  
1 = None  
2 = AgCdO  
4 = AgSnO

2

for 45.31  
No. of poles  
1 = 1 pole, 16 A  
B:
Contact circuit  
3 = NO (SPST)  
Coil version  
7 = Sensitive DC  
4 = NC (SPST) 45.71 only  
6 = NO (SPST), ≥ 3.6 mm  
9 = Standard DC (45.31…0610 only)  
Coil voltage  
See coil specifications  
Selecting features and options: only combinations in the same row are possible.  
Type  
Coil version  
sensitive DC
 
0 – 2 – 4  
standard DC  
A
B
C
1
1
1
1
D
3
0
45.31  
0
6
0
45.71  
45.91  
sensitive DC
 
0 – 1  
sensitive DC
 
0 – 2  
3 – 4  
3
0 – 1  
0 – 1  
Technical data  
Insulation according to EN 61810-1  
45.71  
45.31 / 45.91  
Nominal voltage of supply system  
Rated insulation voltage  
Pollution degree  
V AC
 
230/400  
V AC
 
250  
3
230/400  
400  
250  
3
400  
2
2
Insulation between coil and contact set  
Type of insulation  
Reinforced (8 mm)  
Reinforced (8 mm)  
Overvoltage category  
III  
6
III  
Rated impulse voltage  
kV (1.2/50 µs)  
6
Dielectric strength  
V AC
 
4000  
4000  
Insulation between open contacts  
Type of disconnection  
Micro-disconnection  
Full-disconnection  
Overvoltage category  
—
—
III  
Rated impulse voltage  
kV (1.2/50 µs)  
4
Dielectric strength  
V AC/kV (1.2/50 µs)
 
1000/1.5  
2500/4  
Insulation between coil terminals  
Rated impulse voltage (surge) differential mode  
(according to EN 61000-4-5)  
kV (1.2/50 µs)  
2
Other data  
45.71  
45.31 / 45.91  
Bounce time: NO/NC  
Vibration resistance (10…150)Hz: NO/NC  
Shock resistance  
ms 3/3  
2/—  
g
g
20/10  
20/—  
20  
Power lost to the environment  
without contact current  
with rated current  
Recommended distance between relays mounted on PCB  
W
W
0.4  
1.8  
mm ≥
 
5  
5

45 SERIES  
Miniature PCB relays 10 – 16 A  
45  
SERIES  
Contact specification  
F 45 – Electrical life (AC) v contact current  
F 45 – Electrical life (AC) v contact current  
Type 45.71  
Type 45.31/45.91  
A
Resistive load – cosφ = 1  
Resistive load – cosφ = 1  
Inductive load – cosφ = 0.4  
F 45 – Electrical life (AC) v contact current  
Type 45.31…4310  
Resistive load – cosφ = 1  
15  
5
10  
20  
H 45 – Maximum DC1 breaking capacity  
•
When switching a resistive load (DC1) having voltage and current  
values under the curve, an electrical life of ≥ 100 · 10

3

cycles (45.71) and  
≥ 30 · 10

3

cycles (45.31, 45.91) can be expected.  
•
In the case of DC13 loads, the connection of a diode in parallel with the  
load will permit a similar electrical life as for a DC1 load.  
Note: the release time for the load will be increased.  
DC voltage (V)  
6

45 SERIES  
Miniature PCB relays 10 – 16 A  
45  
SERIES  
Coil specifications  
DC coil data – 0.36 W sensitive  
DC coil data – 0.55 W standard  
Nominal  
voltage  
Coil  
code  
Operating range  
Resistance  
R
Rated coil  
consumption  
Nominal  
voltage  
Coil  
code  
Operating range  
Resistance  
R
Rated coil  
consumption  
A
U

N  

U

min  

U

max  

I
at U

N  

U

N  

U

min  

U

max  

I
at U

N  

V
6
V
V
Ω
mA  
60  
30  
15  
7.5  
6
V
6
V
V
Ω
mA  
83  
7
.006  
7
.012  
7
.024  
7
.048  
7
.060  
100  
9
.006  
9
.012  
9
.024  
9
.048  
9
.060  
72  
4.2  
8.4  
16.8  
33.6  
42  
7.2  
4.2  
8.4  
16.8  
33.6  
42  
7.2  
12  
24  
48  
60  
400  
12  
24  
48  
60  
300  
1150  
4400  
7200  
40  
14.4  
28.8  
57.6  
72  
14.4  
28.8  
57.6  
72  
1600  
6400  
10000  
21  
11  
8.3  
R 45 – DC coil operating range v ambient temperature  
limit for 45.31  
1 –
Max. permitted coil voltage.  
2 –
Min. pick-up voltage with coil at ambient temperature.  
Outline drawings  
Type 45.31  
Types 45.71/91  
Please see
general technical information  
7