IDEC-RH2B-ULCDC12V

Part #IDEC-RH2B-ULCDC12V
Download 
IDEC-RH2B-ULCDC12V
RH  
Relays &
 
Sockets  
RH Series Compact Power Relays  
Key features  
•ꢀ
SPDT through 4PDT, 10A contacts  
•ꢀ
Compact power type relays  
•ꢀ
Miniature power relays with a large capacity  
•ꢀ
10A contact capacity  
•ꢀ
Compact size saves space  
Part Number Selection  
Part Number  
Blade  
Terminal  
PCB Termi-  
nal  
Coil Voltage Code  
(Standard Stock in bold)  
Contact  
Model  
Standard  
RH1B-U
0
 
RH1V2-U
0  
SPDT  
With Indicator  
—
RH1B-UL
0  
RH1B-UC
0  
RH1B-ULC
0  
RH1B-UT
0  
RH1B-UD
0  
RH1B-ULD
0  
RH2B-U
0  
AC6
V
,
A
C12
V
,
AC24V
, AC110
V
,
AC120V
,  
AC220
V
,
AC240V
DC6
V
,
DC12V
,
DC24V
,  
DC48
V
,
D
C110V  
With Check Button  
—
With Indicator and Check Button  
Top Bracket Mounting  
With Diode (DC coil only)  
With Indicator and Diode (DC coil only)  
Standard  
—
—
DC6
V
,
DC12V
,
DC24V
, DC48
V
,
D
C110V  
DC12V
,
DC24V
, DC48
V
,
D
C110V  
RH1V2-UD
0  
—
RH2V2-U
0  
RH2V2-UL
0  
—
DPDT  
With Indicator  
RH2B-UL
0  
RH2B-UC
0  
RH2B-ULC
0  
RH2B-UT
0  
RH2B-UD
0  
AC6
V
,
A
C12
V
,
AC24V
,
AC110-120V
,  
AC220-240V  
DC6
V
,
DC12V
,
DC24V
, DC48
V
,
D
C100-110V  
With Check Button  
With Indicator and Check Button  
Top Bracket Mounting  
With Diode (DC coil only)  
With Indicator and Diode (DC coil only)  
Standard  
—
—
RH2V2-UD
0  
DC6
V
,
DC12V
,
DC24V
, DC48
V
,
D
C100-110V  
RH2B-ULD
0
RH2V2-ULD
0  
RH3B-U
0  
RH3V2-U
0  
3PDT  
With Indicator  
RH3B-UL
0  
RH3B-UC
0  
RH3B-ULC
0  
RH3B-UT
0  
RH3B-UD
0  
RH3B-ULD
0  
RH4B-U
0  
RH3V2-UL
0  
AC6
V
,
A
C12
V
,
AC24V
, AC110
V
,
AC120V
,  
AC220
V
,
AC240V
DC6
V
,
DC12V
,
DC24V
,  
DC48
V
,
D
C110V  
With Check Button  
—
With Indicator and Check Button  
Top Bracket Mounting  
With Diode (DC coil only)  
With Indicator and Diode (DC coil only)  
Standard  
—
—
—
DC6
V
,
D
C12
V
,
D
C24
V
,
D
C48
V
,
D
C110V  
—
RH4V2-U
0  
4PDT  
With Indicator  
RH4B-UL
0  
RH4B-UC
0  
RH4B-ULC
0  
RH4B-UT
0  
RH4B-UD
0  
RH4B-ULD
0  
RH4V2-UL
0  
AC6
V
,
A
C12
V
,
AC24V
, AC110
V
,
AC120V
,  
AC220
V
,
AC240V
DC6
V
,
DC12V
,
DC24V
, DC48
V
,  
DC110V  
With Check Button  
—
With Indicator and Check Button  
Top Bracket Mounting  
With Diode (DC coil only)  
With Indicator and Diode (DC coil only)  
—
—
RH4V2-UD
0  
DC6
V
,
D
C12
V
,
D
C24
V
,
D
C48
V
,
D
C110V  
—
PCB terminal relays are designed to mount directly to a circuit board without any socket.  
Ordering Information  
When ordering, specify the Part No. and coil voltage code:  
(example)
RH3B-U  
AC120V  
Part No.  
Coil Voltage Code  
800-262-IDEC
(4332)
•
USA & Canada  
773  

RH  
Relays & Sockets  
Sockets
(for Blade Terminal Models)  
Relays  
RH1B  
RH2B  
RH3B  
RH4B  
Standard DIN Rail Mount

1

Finger-safe DIN Rail Mount

1  

Through Panel Mount  
SH1B-51  
PCB Mount  
SH1B-62  
SH2B-62  
SH3B-62  
SH4B-62  
SH1B-05  
SH2B-05  
SH3B-05  
SH4B-05  
SH1B-O5C  
SH2B-05C  
SH3B-05C  
SH4B-05C  
1. DIN
 
Rail mount socket  
comes with two  
horseshoe clips. Do  
not use unless you  
plan to insert pullover  
wire spring. Replace-  
ment horseshoe  
SH2B-51  
SH3B-51  
SH4B-51  
clip part number is  
Y778-011.  
Hold Down Springs & Clips  
For DIN  
Mount Socket  
For Through Panel &  
PCB Mount Socket  
Appearance  
Item  
Relay  
SY2S-02F1

2  

SY4S-02F1

2  

SH3B-05F1

2  

SH4B-02F1

2  

2. Must
 
use horseshoe clip when  
mounting in DIN mount socket.  
Replacement horseshoe clip  
part number is Y778-011.  
RH1B  
RH2B  
RH3B  
RH4B  
Pullover Wire Spring  
SY4S-51F1  
3. Two
 
required per relay.  
Leaf Spring (side latch)  
Leaf Spring (top latch)  
RH1B, RH2B, RH3B, RH4B  
RH1B, RH2B, RH3B, RH4B  
SFA-202

3  

SFA-101

3  

SFA-302

3  

SFA-301

3  

AC Coil Ratings  
Rated Current (mA)
 
1ꢀ5 at ꢁ20C  
AC ꢀ2Hz
 
AC 62Hz  
Coil Resistance (Ω)  
125 at ꢁ20C  
Operation Characteristics  
(against rated values at ꢁ2ºC)  
Voltage  
(V)  
Max. Continuous  
Pickup  
Voltage  
Dropout  
Voltage  
SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT 4PDT  
Applied Voltage  
6
170  
86  
240  
121  
60.5  
—
330  
165  
81  
387  
196  
98  
150  
75  
200  
100  
50  
280  
140  
70  
330  
165  
83  
330  
165  
83  
9.4  
39.3  
153  
—
6.4  
25.3  
103  
5.4  
21.2  
84.5  
1,800  
12  
24  
110  
42  
37  
9.6  
18.1  
21.6  
8.4  
—
15.5  
18.2  
18.2  
2,200  
9.4-  
10.8  
80%  
maximum  
30%  
minimum  
110-120  
—
—
—
—
8.0-9.2  
—
—
—
—
—
—
110%  
120  
8.6  
4.7  
—
4.9  
—
—
16.4  
8.8  
—
19.5  
10.7  
—
7.5  
4.1  
—
4.3  
—
—
14.2  
7.7  
—
16.5  
9.1  
16.5  
9.1  
—
—
—
10,800 7,360  
10,800 7,360  
220  
220-240  
240  
4.7-5.4  
—
4.0-4.6  
—
18,820  
—
—
—
8.2  
9.8  
7.1  
8.3  
8.3  
12,100 9,120  
DC Coil Ratings  
Coil Resistance (Ω)  
125 at ꢁ20C  
Operation Characteristics  
(against rated values at ꢁ2ºC)  
Rated Current (mA)
 
1ꢀ5 at ꢁ20C  
Voltage  
(V)  
Max. Continuous  
Applied Voltage  
Pickup  
Voltage  
Dropout  
Voltage  
SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT 4PDT  
6
128  
64  
32  
18  
—
8
150  
75  
240  
120  
60  
250  
125  
62  
47  
188  
40  
160  
25  
100  
24  
96  
12  
Standard coil volt-  
ages are in
BOLD
.  
24  
36.9  
18.5  
8.2-9.0  
—
750  
650  
400  
388  
1,550  
—
80%  
maximum  
10%  
minimum  
110%  
48  
30  
31  
2,660  
—
2,600  
12,250  
—
1,600  
—
100-110  
110  
—
—
15  
12.8  
13,800  
8,600  
7,340  
774  

RH  
Relays &
 
Sockets  
Contact Ratings  
UL Ratings  
Resistive  
General Use  
RH1  
Horsepower Rating  
Maximum Contact Capacity  
Allowable Contact Power  
Voltage  
RH1  
RH2  
RH1  
Rated Load  
RH3  
RH4  
RH3 RH4  
RH3  
RH4  
Continuous  
Model  
RH2  
7A  
—
7A  
—
RH2  
5A 1/3
 
HP 1/3
 
HP  
7.5A 7.5A
 
1/6 HP
 
1/6 HP  
Resistive  
Load  
Inductive  
Load  
Voltage  
Res.  
Load  
Ind.  
Load  
Current  
240V AC
 
10A  
7.5A  
10A  
10A  
—
7.5A  
10A  
—
6.5A  
—
—
—
—
(V)  
120V AC  
30V DC  
28V DC  
—
10A  
—
110 AC  
220 AC  
30 DC  
110 AC  
220 AC  
30 DC  
10A  
7A  
7A  
4.5A  
7A  
1540VA  
300W  
990VA  
210W  
—
—
—
—
—
—
—
—
SPDT  
10A  
10A  
10A  
10A  
10A  
7.5A  
10A  
7.5A  
5A  
DPDT  
3PDT  
4PDT  
CSA Ratings  
1650VA  
300W  
1100VA  
225W  
Horse-  
power  
Rating  
7.5A  
Resistive  
General Use  
Voltage  
Note: Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms  
RH1 RH2 RH3 RH4 RH1 RH2 RH3 RH4  
RH1, 2, 3  
1/3 HP  
1/6 HP  
—
240V AC
 
10A  
120V AC
 
10A  
10A  
10A  
10A  
—
7.5A  
10A 7.5A 7.5A  
10A 7A 7.5A  
7A  
7A  
7A  
—
—
5A  
7.5A  
—
TÜV Ratings  
10A  
10A  
Voltage  
240V AC  
30V DC  
RH1  
10A  
10A  
RHꢁ  
10A  
10A  
RH3  
7.5A  
10A  
RH4  
30V DC  
10A  
7.5A  
10A  
AC: cos ø = 1.0, DC: L/R = 0 ms  
Socket Specifications  
Sockets  
Terminal  
Electrical Rating  
250
V
,
1
0A  
Wire Size  
Torque  
(Coil) M3 screws  
5.5ꢀ-ꢀ9ꢀin•lbs  
9ꢀ-ꢀ11.5ꢀin•lbs  
SH1B-05  
Maximum up to 2–#12AWG  
Maximum up to 2–#12AWG  
Maximum up to 2–#12AWG  
Maximum up to 2–#12AWG  
(contact) M3.5 screws with captive wire clamp  
DIN Rail  
Mount  
Sockets  
SH2B-05  
SH3B-05  
SH4B-05  
M3.5 screws with captive wire clamp  
300
V
,
1
0A  
250
V
,
1
0A  
300
V
,
1
0A  
9ꢀ-ꢀ11.5ꢀin•lbs  
(coil) M3 screws  
5.5ꢀ-ꢀ9ꢀin•lbs  
9ꢀ-ꢀ11.5ꢀin•lbs  
SH1B-05C  
(contact) M3.5 screws with captive wire clamp, fingersafe  
Finger-safe  
DIN Rail  
Mount  
SH2B-05C  
SH3B-05C  
SH4B-05C  
M3.5 screws with captive wire clamp, fingersafe  
Solder  
9ꢀ-ꢀ11.5ꢀin•lbs  
Through  
Panel  
Mount  
Socket  
SH1B-51  
SH2B-51  
SH3B-51  
SH4B-51  
300
V
,
1
0A  
—
—
SH1B-62  
PCB mount  
PCB mount  
250
V
,
1
0A  
300
V
,
1
0A  
—
—
—
—
PCB Mount  
Socket  
SH2B-62  
SH3B-62  
SH4B-62  
Accessories  
Item  
Appearance  
Use with  
Part No.  
Remarks  
The BNDN1000 is designed to accommodate DIN mount sockets.  
Made of durable extruded aluminum, the BNDN1000 measures 0.413  
(10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard  
length is 39” (1,000mm).  
Aluminum  
DIN Rail  
(1 meter length)  
All DIN rail sockets  
BNDN1000  
DIN Rail End  
Stop  
DIN rail  
BNL5  
9.1 mm wide.  
Replacement  
Hold-Down  
Spring Anchor  
DIN mount sockets and hold  
down springs.  
For use on DIN rail mount socket when using pullover wire hold down  
spring. 2 pieces included with each socket.  
Y778-011  
800-262-IDEC
(4332)
•
USA & Canada  
77ꢀ  

RH  
Relays & Sockets  
Specifications  
Contact Material  
Contact Resistance

1  

Silver cadmium oxide  
50mΩ maximum  
Minimum Applicable Load  
24V DC, 30 mA; 5V DC, 100 mA (reference value)  
SPDT  
DPDT  
20ms maximum  
Operating Time

2  

Release Time

2  

3PDT  
4PDT  
25ms maximum  
20ms maximum  
25ms maximum  
SPDT  
DPDT  
3PDT  
4PDT  
SPDT  
DPDT  
3PDT  
4PDT  
AC: 1.1VA (50Hz), 1VA (60Hz)  
AC: 1.4VA (50Hz), 1.2VA (60Hz)  
AC: 2VA (50Hz), 1.7VA (60Hz)  
AC: 2.5VA (50Hz), 2VA (60Hz)  
100MΩ minimum (500V DC megger)  
DC: 0.8W  
DC: 0.9W  
DC: 1.5W  
DC: 1.5W  
Power Consumption  
(approx.)  
Insulation Resistance  
Between live and dead parts:  
Between contact and coil:  
2,000V AC, 1 minute  
2,000V AC, 1 minute  
SPDT  
Between contacts of the same pole:
 
1,000V AC, 1 minute  
3
Dielectric Strength  
Between live and dead parts:  
Between contact and coil:  
2,000V AC, 1 minute  
2,000V AC, 1 minute  
DPDT  
3PDT  
4PDT  
Between contacts of different poles: 2,000V AC, 1 minute  
Between contacts of the same pole:
 
1,000V AC, 1 minute  
Electrical:  
Mechanical:  
1,800 operations/hour maximum  
18,000 operations/hour maximum  
Operating Frequency  
Vibration Resistance  
Damage limits:  
Operating extremes:  
10 to 55Hz, amplitude 0.5 mm  
10 to 55Hz, amplitude 0.5 mm  
Damage limits:  
Operating extremes:  
1,000m/s

2

(100G)  
Shock Resistance  
Mechanical Life  
200m/s

2

(20G – SPDT, DPDT)  
100m/s

2

(10G – 3PDT, 4PDT)  
50,000,000 operations minimum  
DPDT  
500,000 operations minimum (120V AC, 10A)  
SPDT  
3PDT  
4PDT  
Electrical Life  
200,000 operations minimum (120V AC, 10A)  
–25 to +70°C (no freezing)  
SPDT  
DPDT  
3PDT  
4PDT  
Operating  
Temperature

4  

Operating Humidity  
Weight (approx.)  
45 to 85% RH (no condensation)  
SPDT: 24g, DPDT: 37g, 3PDT: 50g, 4PDT: 74g  
Note: Above values are initial values.  
1. Measured
 
using 5V DC, 1A voltage drop method  
2. Measured
 
at the rated voltage (at 20°C), excluding contact bouncing  
Release time of relays with diode: 40 ms maximum  
3. Relays
 
with indicator or diode: 1000V AC, 1 minute  
4. For
 
use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve. The operating  
temperature range of relays with indicator or diode is –25 to +40°C.  
776  

RH  
Relays &
 
Sockets  
Characteristics (Reference Data)  
DC Load  
Electrical Life Curves  
AC Load  
1000  
(RH1)  
500  
1000  
120V AC resistive  
(RH1)  
500  
30V DC resistive  
100  
50  
100  
50  
100V DC resistive  
30V DC inductive  
100V DC inductive  
20  
10  
20  
240V AC inductive  
240V AC resistive  
10  
120V AC inductive  
10  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
Load Current (A)  
Load Current (A)  
(RH2)

1000  

(RH2)  
1000  
500  
120V AC resistive  
30V DC resistive  
500  
100  
50  
100  
50  
30V DC  
100V DC resistive  
100V DC inductive  
inductive  
240V AC resistive  
120V AC inductive  
240V AC inductive  
20  
10  
20  
10  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
Load Current (A)  
Load Current (A)  
(RH3/RH4)  
(RH3/RH4)

1000  

1000  
500  
120V AC resistive  
30V DC resistive  
500  
30V DC inductive  
100  
50  
100  
50  
20  
10  
100V DC resistive  
100V DC inductive  
20  
10  
240V AC inductive  
240V AC resistive  
120V AC inductive  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
Load Current (A)  
Load Current (A)  
Maximum Switching Capacity  
(RH1)  
(RH2/RH3/RH4)  
10.0  
10.0  
AC resistive  
AC inductive  
AC resistive  
AC inductive  
5.0  
5.0  
DC resistive  
DC resistive  
1.0  
0.5  
1.0  
0.5  
DC inductive  
DC inductive  
0.1  
0.1  
1
1
5
10  
50  
100  
200 300  
5
10  
50  
100  
200 300  
Load Voltage (V)  
Load Voltage (V)  
800-262-IDEC
(4332)
•
USA & Canada  
777  

RH  
Relays & Sockets  
Continuous Load Current vs. Operating Temperature Curve (Basic Type, With Check Button, and Top Bracket Mounting Type)  
Note: The rated voltage is  
(RH3/RH4)  
Note: The rated voltage is  
(RH1)  
Note: The rated voltage is  
(RH2)  
applied to the coil.  
applied to the coil.  
applied to the coil.  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
DC Coil  
DC Coil  
AC Coil  
AC/DC Coil  
AC Coil  
1
2 3 4 5 6 7 8 9
 
10  
1
2 3 4 5 6 7 8 9
 
10  
1
2
3
4
5
6
7
8
9
10  
Load Current (A)  
Load Current (A)  
Load Current (A)  
Internal Connection (View from Bottom)  
Basic Type  
SPDT  
DPDT  
3PDT  
4PDT  
With Check Button  
Front  
1
5
9
2
6
3
7
4
8
Pushbutton  
10  
11  
12  
Contacts can be operated by pressing the  
check button.  
(+)  
13 (–)  
14  
With Indicator (-L type)  
SPDT  
3PDT  
4PDT  
DPDT  
1
5
9
1
5
9
2
6
10  
4
8
12  
1
5
9
4
8
12  
1
5
9
2
6
10  
3
7
11  
4
8
12  
When the relay is energized,  
the indicator goes on.  
Below  
100V  
AC/DC  
Below  
24V AC/  
DC  
13  
14  
13( – )  
( +
)
1
4  
( + )  
( – )  
( + )  
14  
( – )  
13  
13( – )  
( +
)
1
4  
•ꢀ
Relay coils less than 100V  
DC do not contain a protec-  
tion diode (except DPDT).  
•ꢀ
Relay coils below 100V  
use LED indicator, coils  
above 100V use neon lamp  
indicator.  
1
5
9
1
5
9
4
8
12  
1
5
9
2
6
4
8
1
5
9
2
6
3
7
4
8
100V  
AC/DC  
and over  
24V AC/  
DC and  
over  
10  
12  
10  
11  
12  
•ꢀ
LED color of DPDT model  
is green  
13  
14  
13 (–)  
(+) 14  
(–)  
(+)  
( – )  
( + )  
13  
14  
( – )  
13  
( + )14  
With Diode (-D type)  
SPDT  
DPDT  
3PDT  
4PDT  
Contains a diode to absorb the back emf  
generated when the coil is de-energized. The  
release time is slightly longer. Available for DC  
coil only.  
1
5
9
1
5
9
4
8
1
5
9
2
6
4
8
1
5
9
2
6
3
7
4
8
12  
10  
12  
10  
11  
12  
13  
(–)  
14  
(+)  
(–)  
(+)  
14  
13  
•ꢀ
Diode Characteristics  
(+)  
14  
(+)  
14  
13 (–)  
(–)  
13  
Reverse withstand voltage: 1,000V  
Forward current: 1A  
778  

RH  
Relays &
 
Sockets  
With Indicator LED & Diode (-LD type)  
SPDT  
3PDT  
4PDT  
DPDT  
1
5
9
1
5
9
4
8
12  
Below  
24V AC/  
DC  
Below  
100V DC  
13  
14  
( + )  
( – )  
( – )  
( + )14  
13  
Contains an LED indicator and  
a surge absorber, and has the  
same height as the basic type.  
1
5
9
LED color of DPDT model is  
green.  
1
5
9
4
8
12  
24V AC/  
DC and  
over  
100V DC  
and over  
( + )  
14  
( – )  
13  
13  
( – )  
14  
( + )  
Dimensions (mm)  
RH1B-U/RH1B-UL/RH1B-UD/RH1B-ULD  
RH2B-U/RH2B-UL/RH2B-UD/RH2B-ULD  
RH3B-U/RH3B-UL/RH3B-UD/RH3B-ULD  
T
o
tal length from panel surface including relay socket  
T
o
tal length from panel surface including relay socket  
T
o
tal length from panel surface including relay socket  
(
)
(
)
SH1B-05: 61.5
 
63.5
max.,
SH1B-51: 39.6
 
41.6
max.  
(
)
(
)
SH2B-05: 61.5
 
63.5
max.,
SH2B-51: 39.6
 
41.6
max.  
(
)
(
)
SH3B-05: 61.5
 
63.5
max.,
SH3B-51: 39.6
 
41.6
max.  
Dimensions in the (  
include a hold-down spring.  
)
Dimensions in the (  
include a hold-down spring.  
)
Dimensions in the (  
include a hold-down spring.  
)
ø2.6 hole  
ø2.6 hole  
ø2.6 hole  
1
5
1
5
4
8
9
9
12  
14  
13 14  
2
6
4
8
1
5
13  
5.4  
6.4  
14  
9
10  
11  
35.6 max.  
6.4  
21  
13  
14  
35.6 max.  
6.4  
31  
35.6 max.  
RH4B-U/RH4B-UL/RH4B-UD/RH4B-ULD  
RH1B-UT  
RH2B-UT  
T
o
tal length from panel surface including relay socket  
(
)
(
)
SH4B-05: 61.5
 
63.5
max.,
SH4B-51: 39.6
 
41.6
max.  
Dimensions in the (  
include a hold-down spring.  
)
ø2.6 hole  
ø2.6 hole  
1
5
1
5
4
8
9
13 14  
9
12  
14  
13  
ø2.6 hole  
3.5  
14.5  
2
5.4  
6.4  
3.5  
2
35.6 max.  
21.5  
35.6 max.  
6.4  
1
5
2
6
3
7
4
8
9
10  
11  
12  
13  
14  
6.4  
41  
35.6 max.  
RH3B-UT  
RH4B-UT  
3.5  
ø2.6 hole  
2
3.5  
ø2.6 hole  
1
5
2
6
4
8
1
5
2
6
3
7
4
8
9
10  
12  
9
10  
11  
12  
13  
14  
13  
14  
21.5  
31.5  
2
35.6 max.  
42 max.  
6.4  
28  
41.5  
35.6 max.  
6.4  
800-262-IDEC
(4332)
•
USA & Canada  
779  

RH  
Relays & Sockets  
Dimensions con’t (mm)  
RH1V2-U/RH1V2-UD  
RH2V2-U/RH2V2-UL/RH2V2-UD  
8-ø2.4 holes  
0.5  
3-ø2.4 holes  
2-ø2 holes  
0.5  
1
5
1
5
4
8
9
13 14  
9
12  
14  
13  
35.6 max.  
4.6  
14  
10  
14.2  
21  
35.6 max.  
4.6  
4.4  
RH3V2-U/RH3V2-UL/RH3V2-D  
RH4V2-U/RH4V2-UL/RH4V2-UD  
30  
10  
11-ø2.4 holes  
10  
10  
14-ø2.4 holes  
1
5
2
6
4
8
1
5
2
6
3
7
4
8
9
10  
11  
9
10  
11  
12  
14  
13  
14  
13  
0.5  
4.6  
31  
0.5  
41  
35.6 max.  
35.6 max.  
4.6  
Standard DIN Rail Mount Sockets  
SH1B-05  
SH2B-05  
17  
8
31.5  
18  
22  
31.5  
18  
DIN Rail  
(BNDN)  
DIN Rail  
(BNDN)  
Terminal Arrangement  
M3.5
T
e
rminal  
Screw  
8
M3.5
T
e
rminal  
Screw  
Terminal Arrangement  
2-ø4.2 Mounting Holes  
(or M4
T
a
pped Holes)  
5
1
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
8
4
5
1
16  
26  
4.4 max.  
5.5 min.  
14 13  
9
5.5 min.  
4.8 min.  
4 max.  
ø3.6 min.  
5.9 max.  
M3
T
e
rminal  
Screw  
14 13  
12  
9
4.4 max.  
7.9 max.  
(
)
T
o
p View  
(
)
Top View  
14.5  
25  
16  
20  
14.5  
25  
26  
30  
7.9 max.  
ø3.2 min.  
ø3.6 min.  
(For terminals 13 and 14)  
(For terminals 1, 5, and 9)  
SH3B-05  
SH4B-05  
31.5  
31.5  
18  
42  
32  
DIN Rail  
(BNDN)  
DIN Rail  
(BNDN)  
8
18  
8
M3.5 Terminal  
Screw  
M3.5 Terminal  
Screw  
Terminal Arrangement  
Terminal Arrangement  
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
8
4
6
2
5
1
7
3
8
4
6
2
5
1
46  
36  
14  
12 11  
13  
9
4.4 max.  
5.5 min.  
14  
13  
9
4.4 max.  
5.5 min.  
10  
12 10  
(
)
Top View  
46  
50  
14.5  
25  
(
)
Top View  
7.9 max.  
36  
40  
14.5  
7.9 max.  
ø3.6 min.  
25  
ø3.6 min.  
782  

RH  
Relays &
 
Sockets  
Dimensions con’t (mm)  
Finger-safe DIN Rail Mount Sockets  
SH1B-05C  
SH2B-05C  
36  
25  
22  
17  
36  
M3.5 Terminal  
7
DIN Rail  
(BNDN)  
M3.5 Terminal  
Screw  
7
Screw  
Terminal Arrangement  
25  
DIN Rail  
(BNDN)  
Terminal Arrangement  
8
4
5
1
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
5
1
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
26  
16  
14 13  
12  
M3 Terminal  
Screw  
9
14  
13  
9
(
)
Ring terminals  
cannot be used.  
Top View  
18.7  
Ring terminals  
cannot be used.  
26  
30  
18.7  
29.5  
(
)
16  
20  
Top View  
29.5  
SH3B-05C  
SH4B-05C  
When using  
BAA/BAP: 33  
32  
M3.5 Terminal  
Screw  
36  
25  
42  
7
DIN Rail  
(BNDN)  
Terminal Arrangement  
25  
7
DIN Rail  
(BAA/BAP)  
Terminal Arrangement  
8
4
6
2
5
1
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
8
4
6
2
5
1
7
3
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
36  
46  
14  
12 10  
13  
9
14  
12  
13  
9
11  
10  
(
)
Top View  
Ring terminals  
cannot be used.  
18.7  
29.5  
36  
40  
Ring type crimping  
terminals cannot be used.  
(
)
Top View  
18.7  
29.5  
46  
50  
Through Panel Mount Socket  
SH1B-51  
SH2B-51  
SH3B-51  
SH4B-51  
800-262-IDEC
(4332)
•
USA & Canada  
781  

RH  
Relays & Sockets  
Dimensions con’t (mm)  
PCB Mount Sockets  
SH1B-62  
SH2B-62  
6.8  
21.5 min.  
ø2.4 holes  
3-  
Terminal Arrangement  
Terminal Arrangement  
2.85  
18 min.  
15.5  
10  
1
5
9
4
8
12  
1
5
9
4.4  
13 14  
13 14  
3
(Bottom View)  
21.2  
18  
(Bottom Viewꢀ  
3
11  
11  
ø2 holes  
2-  
15  
8-ø2.4 holes  
15  
2
1.5  
(Tolerance 0.1ꢀ  
2
* 36 min. when using  
hold-down springs  
(Tolerance 0.1)  
* 34 min. when using  
hold-down springs  
12.2  
SH3B-62  
SH4B-62  
36 min.  
21.3  
10 10  
Terminal Arrangement  
6.85  
45 min.  
31.3  
10 10 10  
Terminal Arrangement  
7.35  
1
5
9
2
6
3
7
4
8
1
5
9
2
6
4
8
10 11 12  
10 12  
13  
14  
13  
14  
3
45  
(Bottom View)  
3
36  
(Bottom View)  
11  
15  
11  
15  
14-ø2.4 holes  
(Tolerance 0.1)  
ø2.4 holes  
11-  
2
2
* 36 min. when using  
hold-down springs  
39.2  
(Tolerance 0.1)  
* 36 min. when using  
hold-down springs  
30.2  
78ꢁ  

Operating Instructions  
Relays &
 
Sockets  
Operating Instructions  
Driving Circuit for Relays  
Protection for Relay Contacts  
1. To ensure correct relay operation, apply rated voltage to the relay coil.  
1. The contact ratings show maximum values. Make sure that these values are  
not exceeded. When an inrush current flows through the load, the contact  
may become welded. If this is the case, connect a contact protection circuit,  
such as a current limiting resistor.  
2. Input voltage for the DC coil:  
A complete DC voltage is best for the coil power to make sure of stable relay  
operation. When using a power supply containing a ripple voltage, suppress  
the ripple factor within 5%. When power is supplied through a rectification  
circuit, the relay operating characteristics, such as pickup voltage and dropout  
voltage, depend on the ripple factor. Connect a smoothing capacitor for better  
operating characteristics as shown below.  
2. Contact protection circuit:  
When switching an inductive load, arcing causes carbides to form on the  
contacts, resulting in increased contact resistance. In consideration of contact  
reliability, contact life, and noise suppression, use of a surge absorbing circuit  
is recommended. Note that the release time of the load becomes slightly  
longer. Check the operation using the actual load. Incorrect use of a contact  
protection circuit will adversely affect switching characteristics. Four typical  
examples of contact protection circuits are shown in the following table:  
Pulsation  
Smoothing  
Capacitor  
Emin Emax  
Emean  
DC  
+
–
Relay  
R
Emax – Emin  
Emean  
Ripple Factor (%)  
¥ 100%  
This protection circuit can be used when the load  
impedance is smaller than the RC impedance in an  
AC load power circuit.  
•ꢀ
R: Resistor of approximately the same resistance  
value as the load  
Emax =
 
Maximum of pulsating current  
Emin =
 
Minimum of pulsating current  
Emean =
 
DC mean value  
Power  
Ind. Load  
C
R
3. Leakage current while relay is off:  
•ꢀ
C:0.1 to 1 µF  
When driving an element at the same time as the relay operation, special  
consideration is needed for the circuit design. As shown in the incorrect  
circuit below, leakage current (Io) flows through the relay coil while the relay  
is off. Leakage current causes coil release failure or adversely affects the  
vibration resistance and shock resistance. Design a circuit as shown in the  
correct example.  
This protection circuit can be used for both AC and  
DC load power circuits.  
R: Resistor
 
of approximately the same resistance  
value as the load  
C: 0.1
 
to 1 µF  
This protection circuit can be used for DC load power  
circuits. Use a diode with the following ratings.  
Reverse withstand voltage: Power voltage of the  
load circuit x 10  
+
Incorrect  
Correct  
TE  
R
Power  
–
R
Ind. Load  
D
Io  
Forward current: More than the load current  
This protection circuit can be used for both AC and  
DC load power circuits.  
For a best result, when using a power voltage of 24  
to 48V AC/DC, connect a varistor across the load.  
When using a power voltage of 100 to 240V AC/DC,  
connect a varistor across the contacts.  
4. Surge suppression for transistor driving circuits:  
When the relay coil is turned off, a high-voltage pulse is generated, causing a  
transistor to deteriorate and sometimes to break. Be sure to connect a diode  
to suppress the back electromotive force. Then, the coil release time becomes  
slightly longer. To shorten the coil release time, connect a Zener diode  
between the collector and emitter of the transistor. Select a Zener diode with  
a Zener voltage slightly higher than the power voltage.  
Power  
Ind. Load  
3. Do not use a contact protection circuit as shown below:  
This protection circuit is very effective in arc suppression when  
Back emf  
opening the contacts. But, the capacitor is charged while the  
contacts are opened. When the contacts are closed, the capacitor  
is discharged through the contacts, increasing the possibility of  
contact welding.  
suppressing diode  
C
Load  
+
Power  
Relay  
R
–
This protection circuit is very effective in arc suppression when  
opening the contacts. But, when the contacts are closed, a current  
flows to charge the capacitor, causing contact welding.  
C
Load  
Power  
Generally, switching a DC inductive load is more difficult than switching a DC  
resistive load. Using an appropriate arc suppressor, however, will improve the  
switching characteristics of a DC inductive load.  
Soldering  
1. When soldering the relay terminals, use a soldering iron of 30 to 60W, and  
quickly complete soldering (within approximately 3 seconds).  
2. Use a non-corrosive rosin flux.  
800-262-IDEC
(4332)
•
USA & Canada  
817  

Operating Instructions  
Relays & Sockets  
Operating Instructions con’t  
Other Precautions  
2. UL and CSA ratings may differ from product rated values determined by IDEC.  
1. General notice:  
To maintain the initial characteristics, do not drop or shock the relay.  
3. Do not use relays in the vicinity of strong magnetic field, as this may affect  
relay operation.  
The relay cover cannot be removed from the base during normal operation. To  
maintain the initial characteristics, do not remove the relay cover.  
Use the relay in environments free from condensation, dust, sulfur dioxide  
(SO

2

), and hydrogen sulfide (H

2

S).  
Make sure that the coil voltage does not exceed applicable coil voltage range.  
Safety Precautions  
•ꢀ
Turn off the power to the relay before starting installation, removal, wiring,  
maintenance, and inspection of the relays. Failure to turn power off may  
cause electrical shock or fire hazard.  
Precautions for the RU Relays  
•ꢀ
Before operating the latching lever of the RU relay, turn off the power to  
the RU relay. After checking the circuit, return the latching lever to the origi-  
nal position.  
•ꢀ
Observe specifications and rated values, otherwise electrical shock or fire  
hazard may be caused.  
•ꢀ
Do not use the latching lever as a switch. The durability of the latching lever  
is a minimum of 100 operations.  
•ꢀ
Use wires of the proper size to meet voltage and current requirements. Tight-  
en the terminal screws on the relay socket to the proper tightening torque.  
•ꢀ
When using DC loads on 4PDT relays, apply a positive voltage to terminals of  
neighboring poles and a negative voltage to the other terminals of neighbor-  
ing poles to prevent the possibility of short circuits.  
•ꢀ
Surge absorbing elements on AC relays with RC or DC relays with diode are  
provided to absorb the back electromotive force generated by the coil. When  
the relay is subject to an excessive external surge voltage, the surge absorb-  
ing element may be damaged. Add another surge absorbing provision to the  
relay to prevent damage.  
•ꢀ
DC relays with a diode have a polarity in the coil terminals. Apply the DC volt-  
age to the correct terminals.  
818