IDEC-RR3P-UAC120V

Part #IDEC-RR3P-UAC120V
Download 
IDEC-RR3P-UAC120V
RR  
Relays &
 
Sockets  
RR Series Power Relays  
Key features:  
• SPDT
 
through 3PDT, 10A contacts  
• Midget
 
power type relays  
• Available
 
in pin and blade terminal styles.  
• Options
 
include an indicator, check button for test operations and side flange.  
• DIN
 
rail, surface and panel mount sockets are available for a wide a variety of  
mounting applications.  
Part Number Selection  
Part Number  
Coil Voltage Code  
(Standard Stock Items in Bold)  
Contact  
Model  
Pin Terminal
 
Blade Terminal*  
SPDT  
Standard  
RR1BA-U
0
 
RR1BA-UL
0  
RR1BA-UC
0  
RR1BA-ULC
0  
RR1BA-US
0  
RR2BA-U
0  
RR2BA-UL
0  
RR2BA-UC
0  
RR2BA-ULC
0  
RR2BA-US
0  
RR3B-U
0  
With Indicator  
With Check Button  
—
With Indicator and Check Button  
Side Flange Model  
Standard  
DPDT  
3PDT  
RR2P-U
0  
RR2P-UL
0  
RR2P-UC
0  
RR2P-ULC
0  
—
With Indicator  
AC6
V
,
A
C12
V
,
A
C24
V
,
A
C110
V
,
AC120V
,  
AC240
V
,  
DC6
V
,
D
C12
V
,
DC24V
, DC48
V
,
D
C110V  
With Check Button  
With Indicator and Check Button  
Side Flange Model  
Standard  
RR3PA-U
0  
RR3PA-UL
0  
RR3PA-UC
0  
RR3PA-ULC
0  
With Indicator  
RR3B-UL
0  
With Check Button  
With Indicator and Check Button  
RR3B-UC
0  
RR3B-ULC
0  
Side Flange Model  
—
RR3B-US
0  
*Blade type not TUV tested or CE marked.  
Side flange model mounts directly to panel with no socket required.  
Ordering Information  
When ordering, specify the Part No. and coil voltage code:  
(example)
RR3B-U  
AC120V  
Part No.  
Coil Voltage Code  
Sockets  
Relays  
Standard DIN Rail Mount  
SR2P-05  
SR2P-06  
Finger-safe DIN Rail Mount  
Through Panel Mount  
RR2P  
SR2P-05C  
SR3P-05C  
SR2P-51  
SR3P-51  
SR3P-05  
SR3P-06  
RR3PA  
RR1BA  
RR2BA  
RR3B  
SR3B-05  
—
SR3B-51  
All DIN rail mount sockets shown here can be  
mounted using DIN rail BNDN1000.  
1705242125  
800-262-IDEC
(4332)
•
USA & Canada  
883  

RR  
Relays & Sockets  
Hold Down Springs & Clips  
For DIN  
Mount Socket  
For Through Panel &  
PCB Mount Socket  
Appearance  
Description  
Relay  
RR2P  
SR2B-02F1  
SR3B-02F1  
SR3P-01F1  
SR3B-02F1  
Pullover Wire  
Spring  
RR3PA  
RR1BA, RR2BA,  
RR3B  
SR3B-02F1  
Leaf Spring  
(side latch)  
RR2
P
,
R
R3PA  
SFA-203  
–
Accessories  
Item  
Appearance  
Use with  
Part No.  
Remarks  
The BNDN1000 is designed to accommodate DIN mount sockets.  
Made of durable extruded aluminum, the BNDN1000 measures 0.413  
(10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard  
length is 39” (1,000mm).  
Aluminum  
DIN Rail  
(1 meter length)  
All DIN rail sockets  
DIN rail  
BNDN1000  
DIN Rail End  
Stop  
BNL5  
9.1 mm wide.  
Horseshoe clip for sockets  
SR3B-05, SR2P-06, SR3P-06  
Y778-011  
Y703-102  
Replacement  
Hold-Down  
Spring Anchor  
For use on DIN rail mount socket when using pullover wire hold down  
spring. 2 pieces included with each socket.  
Chair clip for sockets  
SR2P-05(C), SR3P-05(C)  
1705242125  
884  

RR  
Relays &
 
Sockets  
Specifications  
Contact Material  
Silver  
Contact Resistance

1  

30 mΩ maximum  
1V DC, 10 mA  
25 ms maximum  
25 ms maximum  
Minimum Applicable Load  
2
Operating Time  
2
Release Time  
AC: 3 VA (50 Hz), 2.5 VA (60 Hz)  
DC: 1.5W  
Power Consumption (approx.)  
Insulation Resistance  
100 MΩ minimum (500V DC megger)  
Between live and dead parts:  
1500V AC, 1 minute  
1500V AC, 1 minute  
1500V AC, 1 minute  
1000V AC, 1 minute  
2000V AC, 1 minute  
2000V AC, 1 minute  
2000V AC, 1 minute  
1000V AC, 1 minute  
Between contact and coil:  
Pin Terminal  
Between contacts of different poles:  
Between contacts of the same pole:  
Between live and dead parts:  
Dielectric  
Strength  
1. Measured
 
using 5V DC, 1A voltage drop method  
2. Measured
 
at the rated voltage (at 20°C), excluding contact  
bouncing  
3. For
 
use under different temperature conditions, refer to  
Continuous Load Current vs. Operating Temperature Curve.  
Between contact and coil:  
Blade Terminal  
Between contacts of different poles:  
Between contacts of the same pole:  
Electrical:  
1800 operations/h maximum  
18,000 operations/h maximum  
Operating Frequency  
Vibration Resistance  
Shock Resistance  
Mechanical:  
Damage limits:  
Operating extremes:  
Damage limits:  
Operating extremes:  
10,000,000 operations  
10 to 55 Hz, amplitude 0.5 mm  
10 to 55 Hz, amplitude 0.5 mm  
1000 m/s

2

(100g)  
100 m/s

2

(10G)  
Mechanical Life  
Electrical Life  
Operating Temperature

3  

200,000 operations (220V AC, 5A)  
–25 to +40°C (no freezing)  
Operating Humidity  
5 to 85% RH (no condensation)  
Weight (approx.) (Standard type)  
RR2P: 90g, RR3PA: 96g, RR1BA/RR2BA/RR3B: 82g  
Coil Ratings  
Rated Current (mA)
 
15ꢀ (at 2ꢁ0C)  
Operating Characteristics (values at 2ꢁ0C)  
Coil Resistance (Ω)  
1ꢁꢀ (at 2ꢁ0C)  
Rated Voltage (V)  
Maximum Continuous  
50 Hz  
60 Hz  
Pickup Voltage  
Dropout Voltage  
Applied Voltage  
6
490  
245  
121  
27  
420  
210  
105  
23  
4.9  
18  
12  
24  
79  
AC  
(50/60 Hz)  
110%  
80% maximum  
30% minimum  
110  
120  
240  
6
1,680  
2,100  
8,330  
25  
24  
20.5  
10.5  
12.1  
240  
120  
60  
12  
100  
DC  
24  
400  
110%  
80% maximum  
10% minimum  
48  
30  
1,600  
8,460  
110  
13  
1705242125  
800-262-IDEC
(4332)
•
USA & Canada  
885  

RR  
Relays & Sockets  
Contact Ratings  
UL Ratings  
Voltage  
240V AC  
120V AC  
30V DC  
Resistive  
General use  
Horse Power Rating  
Maximum Contact Capacity  
10A  
10A  
10A  
7A  
7.5A  
7A  
1/3 HP  
1/4 HP  
—
Allowable Contact Power  
Rated Load  
Continuous  
Current  
Resistive  
Load  
Inductive  
Voltage (V)  
Load  
Res. Load  
Ind. Load  
110 AC  
10A  
7.5A  
10A  
7.5A  
5A  
1650VA AC  
300W DC  
1100VA AC  
150W DC  
CSA Ratings  
10A  
220 AC  
Voltage  
Resistive  
General use  
7A  
30 DC  
5A  
240V AC  
120V AC  
100V DC  
30V DC  
10A  
10A  
—
Note: Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms  
7.5A  
0.5A  
TÜV Ratings  
10A  
7.5A  
Voltage  
240V AC  
30V DC  
10A  
10A  
AC: cos ø = 1.0, DC: L/R = 0 ms  
Socket Specifications  
Relays  
SR2P-05  
SR2P-05C  
SR2P-06  
Terminal  
Electrical Rating  
Wire Size  
Torque  
9 – 11.5in•lbs  
9 – 11.5in•lbs  
9 – 11.5in•lbs  
9 – 11.5in•lbs  
9 – 11.5in•lbs  
9 – 11.5in•lbs  
9 – 11.5in•lbs  
—
M3 screw with captive wire clamp  
300
V
,
1
0A  
300
V
,
1
0A  
300
V
,
1
0A  
300
V
,
1
0A  
300
V
,
1
0A  
300
V
,
1
0A  
Maximum 2 – #12 AWG  
Maximum 2 – #12 AWG  
Maximum 2 – #12 AWG  
Maximum 2 – #12 AWG  
Maximum 2 – #12 AWG  
Maximum 2 – #12 AWG  
Maximum 2 – #12 AWG  
—
M3 screw with captive wire clamp, fingersafe  
M3 screw with captive wire clamp  
M3 screw with captive wire clamp  
M3 screw with captive wire clamp, fingersafe  
M3 screw with captive wire clamp  
M3 screw with captive wire clamp  
Solder  
DIN Rail  
SR3P-05  
Sockets  
SR3P-05C  
SR3P-06  
SR3B-05  
300
V
,
1
5A (10A)* (*CSA rating)  
300
V
,
1
0A  
SR2P-51  
Through  
Panel Mount  
Sockets  
SR3P-51  
SR3B-51  
Solder  
300
V
,
1
0A  
—
—
Solder  
300
V
,
1
0A  
—
—
1705242125  
886  

RR  
Relays &
 
Sockets  
Characteristics (Reference Data)  
Electrical Life Curves  
AC Load  
DC Load  
1000  
1000  
500  
500  
30V DC  
resistive  
100  
50  
100  
110V AC resistive  
100V DC resistive  
50  
220V AC resistive  
110V AC inductive  
100V DC inductive  
20  
10  
20  
10  
220V AC inductive  
30V DC inductive  
5
0.1  
0.5  
1
5
10  
0.01  
0.05 0.1  
0.5  
1
10  
Load Current (A)  
Load Current (A)  
Continuous Load Current vs. Operating Temperature Curve  
(Standard Type, With Check Button, and Side Flange Type)  
Maximum Switching Capacity  
10.0  
AC  
100  
90  
resistive  
5.0  
AC  
inductive  
80  
DC resistive  
70  
DC Coil  
60  
1.0  
0.5  
50  
DC inductive  
AC Coil  
40  
30  
20  
10  
0
1
5
10  
30 50  
100  
200 300  
1
2 3 4 5 6 7 8 9
 
10  
Load Voltage (V)  
Load Current (A)  
Internal Connection (View from Bottom)  
Standard Type  
RR2P-U  
RR3PA-U  
RR1BA-U  
RR2BA-U  
RR3B-U  
With Check Button  
Front  
Pushbutton  
Contacts can be operated by pressing the  
check button.  
With Indicator (-UL type)  
RR2P  
RR3PA  
RR1BA  
RR2BA  
RR3B  
Coil  
Below  
100V  
AC/DC  
When the relay is energized,  
the indicator goes on.  
•
An LED protection diode is  
not contained in relay coils  
below 100V DC.  
•
Coils below 100V use  
LED indicator while coils  
above 100V use neon lamp  
indicator.  
Coil  
100V  
AC/DC  
and over  
1705242125  
800-262-IDEC
(4332)
•
USA & Canada  
887  

RR  
Relays & Sockets  
Dimensions (mm)  
RR2P-U/RR2P-UL  
RR3PA-U/RR3PA-UL  
Total length from panel surface including relay socket  
SR2P-05: 84.5 (87.5) max., SR2P-511: 63 (68) max.  
Total length from panel surface including relay socket  
SR3P-05: 84.5 (87.5) max., SR3P-511: 63 (68) max.  
6
5
7
4
8
4
1
5
8
3
2
6
7
3
9
2
10  
1
11  
9.9  
13  
9.9  
13  
35.6  
28.6  
55.5 max.  
55.5 max.  
Dimensions in the (  
)
Dimensions in the (  
)
include a hold-down spring.  
include a hold-down spring.  
RR1BA-U/RR2BA-UL/RR2BA-U  
RR2BA-UL/RR3B-U/RR3B-UL  
RR1BA-US/RR2BA-US/RR3B-US  
63.5  
7.3  
3.0 ¥ ø2.0 oblong hole  
2-ø4.5 Mounting Holes  
3.0 ¥ ø2.0 oblong hole  
63.5  
Total length from panel surface including relay socket  
SR3B-05: 73 (76) max., SR3B-51: 56 (60) max.  
16.1  
47.5 max.  
73.5  
1
4
2
5
3
6
7
8
9
1
4
2
5
3
6
A
B
7
8
9
36  
A
B
47.5 max.  
7.3  
Dimensions in the (  
)
36  
include a hold-down spring.  
Standard DIN Rail Mount Sockets  
SR2P-05  
SR2P-06  
36  
40  
8
DIN Rail  
(BNDN)  
35  
DIN Rail  
(BNDN)  
8
M3.5 Terminal  
Screw  
25.5  
Terminal Arrangement  
Terminal Arrangement  
5
4
M3.5 Terminal  
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
6
5
4
3
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
Screw  
6
3
29  
7
8
2
1
33  
4.4 max.  
5 min.  
4.9 max.  
5 min.  
ø4.2 hole  
(
)
Top View  
7
8
1
2
ø4.2 hole  
16.5  
20  
28.5  
(
)
Top View  
33  
18  
22  
29  
7.9 max.  
7.9 max.  
ø3.6 min.  
ø3.6 min.  
SR3P-05  
SR3P-06  
42  
8
59  
DIN Rail  
(BNDN)  
DIN Rail  
28.5  
35  
M3.5 Terminal  
M3.5 Terminal  
Screw  
8
(BNDN)  
Terminal Arrangement  
Screw  
Terminal Arrangement  
2-ø4.2 Mounting Hole  
6
5
4
7
8
8
7
6
5
4
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
(or M4 Tapped Holes)  
34  
9
3
2
33  
10 11  
1
4.4 max.  
5 min.  
ø4.2 hole  
4.9 max.  
5 min.  
ø4.2 hole  
(
)
Top View  
9
10 11  
1
2
3
16.5  
20  
28.5  
34  
(
)
Top View  
18  
22  
33  
7.9 max.  
7.9 max.  
ø3.6 min.  
ø3.6 min.  
1705242125  
888  

RR  
Relays &
 
Sockets  
Standard DIN Rail Mount Sockets  
SR3B-05  
36  
31.5  
Terminal Arrangement  
DIN Rail  
(BNDN)  
8
M3.5 Terminal  
Screw  
6
3
5
2
4
1
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
37  
B
9
A
7
4.4 max.  
5.5 min.  
8
(
)
Top View  
7.9 max.  
14.5  
25  
37  
43  
ø3.6 min.  
Finger-safe DIN Rail Mount Sockets  
SR2P-05C  
SR3P-05C  
36  
42  
36.5  
DIN Rail  
(BNDN)  
36.5  
7
DIN Rail  
(BNDN)  
7
Terminal Arrangement  
Terminal Arrangement  
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
5
6
4
3
6
5
4
7
8
2-ø4.2 Mounting Holes  
(or M4 Tapped Holes)  
34  
29  
ø4.2 hole  
2
1
7
8
ø4.2 hole  
9
3
2
10 11  
1
(
)
Top View  
Ring type crimping  
terminals cannot be used.  
(
)
Top View  
21.5  
30  
29  
21.5  
30  
34  
Ring type crimping  
terminals cannot be used.  
Through Panel Mount Socket  
SR2P-51  
SR3P-51  
2-ø3.5 Mounting Holes  
(or M3 Tapped Holes)  
2-ø3.5 Mounting Holes  
(or M3 Tapped Holes)  
4.2  
4.2  
Terminal Arrangement  
Terminal Arrangement  
6
4
1
5
8
5
7
4
8
3
2
6
7
3
9
2
10  
11  
1
(Bottom View)  
(Bottom View)  
34  
2.5  
10 11  
2.5  
34  
2.5  
10 11  
2.5  
SR3B-51  
2-ø4.2 Mounting Holes  
(M4 Tapped Holes)  
35.5*  
22  
38  
11 max.  
7.5  
Terminal Arrangement  
6.75  
1
4
2
5
3
6
7
A
8
9
B
3
6.5  
22  
(Bottom View)  
(Tolerance 0.3)  
*
3.5  
When two or more sockets are  
mounted side by side:  
35  
L = 38 (N – 1) + 35.5  
N: No. of sockets mounted  
1705242125  
800-262-IDEC
(4332)
•
USA & Canada  
889