IDEC-RV2H-2G-D18-C1D2
| Part # | IDEC-RV2H-2G-D18-C1D2 |
| Download | IDEC-RV2H-2G-D18-C1D2 |
14mm Interface Relays:
RV8 Series
Screw Terminal
Spring Clamp Terminal
PRODUCT DESCRIPTION
With the addition of a 14mm version,
IDEC offers a complete line of RV8
interface relays. Ideal for panels with
limited room, these low-profile relays
provide up to a 40% reduction in DIN
rail space when compared with standard
plug-ins. RV8 relays are good for higher
load switching applications, panels with
high I/O content and commercial HVAC
panels. UL listed when paired with a
corresponding socket, it’s easy to save
space with new RV8 models.
IN rail
IN rail
SPECIFICATIONS
KEY FEATURES
Number of Poles
1-pole
2-pole
Contact Configuration
Contact Material
1C (SPDT)
2C (DPDT)
• Space-saving 14mm width.
AgNi
AgNi (Au-plated)
IP20
• Universal AC/DC socket with built-in
surge suppression and green LED
Indicator
Degree of Protection
IP20
Between contact
and coil
5,000V AC for 1 minute
5,000V AC for 1 minute
• Gold plated contacts (2-pole model
only)
Dielectric
strength
Between contacts
of the same pole
1,000V AC for 1 minute
–
1,000V AC for 1 minute
2,500V AC for 1 minute
Between contact
sets
• Pre-assembled relay and DIN mount
socket
Operating
extremes
10 to 55Hz, amplitude 0.75mm (NO
contact), 0.175mm (NC contact)
10 to 55Hz, amplitude 0.75mm (NO contact),
0.1mm (NC contact)
• Universal screw terminals (flat and
Philips) or spring clamp terminals
Vibration
Resistance
Damage limits
10 to 55Hz, amplitude 0.75mm (NO
contact), 0.175mm (NC contact)
10 to 55Hz, amplitude 0.75mm (NO contact),
0.1mm (NC contact)
• Only 70 mm in height from DIN rail
Operating
extremes
98m/s² (NO)
98m/s² (NO)
• Release lever for easy locking and
removal of relay
Shock
Resistance
Damage limits
980m/s²
980m/s²
• Wide input voltage range: 6 to 240V
AC load:30,000 operations minimum
(250V AC, 16A resistive load, operation
frequency 360 operation per hour)
AC load:100,000 operations minimum
(250V AC, 8A resistive load, operation
frequency 360 operation per hour)
Electrical Life – Screw terminal
• High dielectric strength and impulse
withstand voltages.
AC load:30,000 operations minimum
(250V AC, 12A resistive load, operation
frequency 360 operation per hour)
AC load:100,000 operations minimum
(250V AC, 6A resistive load, operation
frequency 360 operation per hour)
Electrical Life – Spring Clamp
terminal
• Reverse polarity protected
• RoHS compliant
10,000,000 operations minimum
(Operation frequency 18,000 operations
per hour)
10,000,000 operations minimum
(Operation frequency 18,000 operations
per hour)
Mechanical Life (no load)
RV8H-1L1-D6, D9, D12, D18, D24, AD12,
AD18, AD24, AD48, AD60, AD110
: -40 to +70°C (Contact current 12A max,
6A per terminal) no freezing
: -40 to +55°C (Contact current 16A max,
8A per terminal) no freezing
RV8H-2L-D6, D9, D12, D18, D24, AD12,
AD18, AD24, AD48, AD60, AD110
: -40 to +70°C (Contact current 6A max) no
freezing
: -40 to +55°C (Contact current 8A max) no
freezing
R
C
US
(when using combination of
RV relay and SV socket)
RV8H-1L1- AD220
: -40 to +55°C (Contact current 16A max,
8A per terminal) no freezing
RV8H-2L- AD220
: -40 to +55°C (Contact current 8A max) no
freezing
Operating Temperature
RV8H-1S1-D6, D9, D12, D18, D24, AD12,
AD18, AD24, AD48, AD60, AD110
: -40 to +70°C (Contact current 12A max,
6A per terminal) no freezing
RV8H-2S-D6, D9, D12, D18, D24, AD12,
AD18, AD24, AD48, AD60, AD110
: -40 to +70°C (Contact current 6A max)
no
freezing
RV8H-1S1- AD220
: -40 to +55°C (Contact current 12A max,
6A per terminal) no freezing
RV8H-2S- AD220
: -40 to +55°C (Contact current 6A max) no
freezing
Operating Humidity
Weight
5 to 85% (no condensation)
5 to 85% (no condensation)
Screw Terminal: Approx.52g
Spring Clamp Terminal: Approx. 49g
Screw Terminal: Approx. 52g
Spring Clamp Terminal: Approx. 49g
1
PART NUMBERS
Screw Terminals
Spring Clamp Terminals
Complete Unit
Complete Unit
Relay Only
2-pole
Relay Only
2-pole
1-pole
1-pole
Input
voltage
Complete
Part Number
Replacement
(Relay Only)
Complete
Replacement
(Relay Only)
Complete
Part Number
Replacement
(Relay Only)
Complete
Replacement
(Relay Only)
Part Number
Part Number
RV2H-1HG1-D5
RV2H-1HG1-D9
RV2H-1HG1-D12
RV2H-1HG1-D18
RV2H-1HG1-D24
RV2H-2G-D5
RV2H-2G-D9
RV2H-2G-D12
RV2H-2G-D18
RV2H-2G-D24
RV8H-1S1-D6
RV8H-1S1-D9
RV8H-1S1-D12
RV8H-1S1-D18
RV8H-1S1-D24
RV2H-1HG1-D5
RV2H-1HG1-D9
RV2H-1HG1-D12
RV2H-1HG1-D18
RV8H-2S-D6
RV8H-2S-D9
RV8H-2S-D12
RV8H-2S-D18
RV2H-2G-D5
RV2H-2G-D9
RV2H-2G-D12
RV2H-2G-D18
RV2H-2G-D24
6V
9V
RV8H-1L1-D6
RV8H-1L1-D9
RV8H-1L1-D12
RV8H-1L1-D18
RV8H-1L1-D24
RV8H-2L-D6
RV8H-2L-D9
RV8H-2L-D12
RV8H-2L-D18
RV8H-2L-D24
12V
18V
RV2H-1HG1-D24 RV8H-2S-D24
24V
RV2H-1HG1-D12
RV2H-1HG1-D18
RV2H-1HG1-D24
RV2H-1HG1-D48
RV2H-1HG1-D60
RV2H-1HG1-D110
RV2H-1HG1-D110
RV2H-2G-D12
RV2H-2G-D18
RV2H-2G-D24
RV2H-2G-D48
RV2H-2G-D60
RV2H-2G-D110
RV2H-2G-D110
RV8H-1S1-AD12
RV8H-1S1-AD18
RV8H-1S1-AD24
RV8H-1S1-AD48
RV8H-1S1-AD60
RV8H-1S1-AD110
RV8H-1S1-AD220
RV2H-1HG1-D12
RV2H-1HG1-D18
RV8H-2S-AD12
RV8H-2S-AD18
RV2H-2G-D12
RV2H-2G-D18
RV2H-2G-D24
RV2H-2G-D48
RV2H-2G-D60
RV2H-2G-D110
RV2H-2G-D110
12V
RV8H-1L1-AD12
RV8H-1L1-AD18
RV8H-1L1-AD24
RV8H-1L1-AD48
RV8H-1L1-AD60
RV8H-1L1-AD110
RV8H-1L1-AD220
RV8H-2L-AD12
RV8H-2L-AD18
RV8H-2L-AD24
RV8H-2L-AD48
RV8H-2L-AD60
RV8H-2L-AD110
RV8H-2L-AD220
18V
RV2H-1HG1-D24 RV8H-2S-AD24
RV2H-1HG1-D48 RV8H-2S-AD48
RV2H-1HG1-D60 RV8H-2S-AD60
RV2H-1HG1-D110 RV8H-2S-AD110
RV2H-1HG1-D110 RV8H-2S-AD220
24V
48V
60V
110V – 125V
220V – 240V
R
A
TINGS
Coil Ratings
Contact Ratings
Operating Characteristics
(Against Rated Voltage)
Power Consumption
(W)
Srew Terminal
Spring Clamp Terminal
1-pole 4,000VA
2-pole 2,000VA
B300 (pilot duty)
1-pole 3,000VA
2-pole 1,500VA
B300 (pilot duty)
Resistive
load
Maximum
Allowable
contact
power
Minimum
Pickup
Maximum
Allowable
Voltage
Rated Voltage
Dropout
Voltage
(at 23°C)
Continuous
Applied
Voltage
Operation Release
AC
AC
DC
Voltage
(at 23°C)
time
time
(50Hz) (60Hz)
Inductive
load
(at 23°C)
(Note 1)
1-pole 250V
AC, 16A (8A
1-pole 250V
AC, 12A (6A
6V
0.45
0.40
0.38
0.43
0.48
–
–
–
–
–
–
–
–
–
–
per terminal) at 55°C, 12A
per terminal) at 70°C
(6A per terminal) at 70°C
Resitive
load
9V
Rated
Load
12V
120%
110%
2-pole 250V
AC, 8A at
55°C, 6A at 70°C
2-pole 250V
AC, 6A at 70°C
18V
Inductive
load
B300 (pilot duty)
B300 (pilot duty)
24V
12V
0.38 0.35
0.35
0.43 0.43
0.43
0.48 0.50
0.50
0.36 0.43
0.43
0.46 0.54
0.54
0.64 0.73
0.73
110%
15ms
15ms
max
1-pole 16A
(8A per
terminal) at 55°C, 12A (6A
terminal) at 70°C
per terminal) at 70°C
1-pole 12A
(6A per
80% max
7% min
(Note 2)
max
18V
Allowable
24V
Switching Current
2-pole 8A
at 55°C, 6A
at 70°C
2-pole 6A
at 70°C
48V
60V
1-pole 4,000VA
1-pole 3,000VA
Allowable
110V – 125V
220V – 240V
Switching Power
2-pole 2,000VA
2-pole 1,500VA
1.10
1.25 1.32
1-pole 6VDC
100mA
2-pole 5VDC
10mA
1-pole 6VDC
100mA
2-pole 5VDC
10mA
Minimum Applicable
Load (reference value)
Note 1: At rated operating temperature
Note 2: Rated Voltage AC/DC 240V : 106%
UL Ratings
Screw Terminal
1-Pole
Spring Clamp Terminal
Voltage
2-Pole
1-Pole
2-Pole
16A (8A per terminal) at 55
°C
12A (6A per terminal) at 70
°C
8A at 55
°C
6A at 70
°C
–
–
250V AC
Resistive
12A (6A per terminal) at 70
°C
6A at 70
°C
2
ACCESSORIES
Marking Plates (Blank and Pre-marked)
Marking Plate Placement
Item
Color Part
Number
Engraving
blank
1-10
ꢁarꢂing ꢃlate
Item
Part Number
Jumper
Black SV9Z-J232B
(32 combs, with 2-combs per
relays, or 16 discrete relays.)
Note
1, 2, 4
SV9Z-PW10
Gray
Blue
SV9Z-J232W
SV9Z-J232S
ꢄoꢅꢂing ꢄeꢆer
ꢇꢈꢉ
SV9Z-PW10-
➀
1-10
SV9Z-PW10-
➀
11-20
SV9Z-PW10-
➀
21-30
SV9Z-PW10-
➀
31-40
SV9Z-PW10-
➀
41-50
SV9Z-PW10-
➀
51-60
SV9Z-PW10-
➀
61-70
SV9Z-PW10-
➀
71-80
SV9Z-PW10-
➀
81-90
SV9Z-PW10-
➀
91-100
SV9Z-PW10-
➀
A-J
SV9Z-PW10-
➀
K-T
SV9Z-PW10-
➀
U-Z
SV9Z-PW10-
➀
GROUND
SV9Z-PW10-
➀
AC
Inꢀert
11-20
21-30
31-40
41-50
51-60
61-70
71-80
81-90
91-100
A-J
Spacer (circuit separator)
Note 3, 4
Light
Grey
SV9Z-SA2W
BC1S-SD0
K-T
Screwdriver
U-Z
–
1. In
place of
➀
insert orientation code: V=Vertical, H=Horizontal
1. Jumper
combs come with 16 pairs of combs, if shorter lengths
are needed simply cut off the excess points.
2. Each
unit has 10 pieces (marking plates).
2. Ensure that the total current to the jumper does not exceed
the overall rated current (Rated current: 6A for spring-clamp
terminals and 8A for screw type terminations).
3. Width of spacer: 2mm
4. When using a cut jumper, please use a spacer on the cut
side.
For additional information see instruction sheet.
Dimensions (mm)
SV9Z-PW10* Marking Plate
SV9Z-SA2W Spacer
Cut
3.0
1.0
6.0
86.5
*Available blank or pre-marked.
35.0
96.7
SV9Z-J232* Jumper
2.0
ꢀꢁ7ꢂꢃ
ꢀꢀꢀꢂꢀ
ꢁꢀꢂꢀ
ꢁꢄꢅꢆꢁꢇꢂ0
3.0
*Available in black, gray and blue.
3
INTERNAL CONNECTIONS
AC/DC Type (1-Pole)
DC Type (1-Pole)
ꢀꢁ ꢂ ꢀꢁ
NO
ꢀꢁ ꢂ ꢀꢁ
NO
ꢀꢁ
NO
ꢀꢁ
NO
ꢀꢁ
NO
ꢀꢁ
NO
ꢆꢀꢇꢈꢉ
ꢃOIꢊ
ꢆꢀ
ꢃOIꢇ
ꢀꢀ ꢂ ꢀꢀ
ꢃOꢄ
ꢀꢀ ꢂ ꢀꢀ
ꢃOꢄ
ꢀꢀ
ꢃOꢄ
ꢀꢀ
ꢃOꢄ
ꢀꢀ
ꢃOꢄ
ꢀꢀ
ꢃOꢄ
ꢆꢅꢇ
ꢋ
ꢉ
ꢆꢅ
ꢃOIꢇ
ꢃOIꢊ
ꢌirꢌꢍit
ꢈirꢈꢉit
ꢀꢅ ꢂ ꢀꢅ
Nꢃ
ꢀꢅ
Nꢃ
ꢀꢅ ꢂ ꢀꢅ
Nꢃ
ꢀꢅ
Nꢃ
ꢀꢅ
Nꢃ
ꢀꢅ
Nꢃ
AC/DC Type (2-Pole)
DC Type (2-Pole)
ꢀꢁ ꢂ ꢃꢁ
NO
ꢀꢁ ꢂ ꢃꢁ
NO
ꢀꢁ
NO
ꢃꢁ
NO
ꢀꢁ
NO
ꢃꢁ
NO
ꢆꢀ
ꢄOIꢇ
ꢆꢀꢇꢈꢉ
ꢄOIꢊ
ꢀꢀ ꢂ ꢃꢀ
ꢄOꢅ
ꢀꢀ ꢂ ꢃꢀ
ꢄOꢅ
ꢀꢀ
ꢄOꢅ
ꢀꢀ
ꢄOꢅ
ꢃꢀ
ꢄOꢅ
ꢃꢀ
ꢄOꢅ
ꢆꢃ
ꢄOIꢇ
ꢆꢃꢇ
ꢄOIꢊ
ꢋ
ꢉ
ꢈirꢈꢉit
ꢌirꢌꢍit
ꢀꢃ ꢂ ꢃꢃ
Nꢄ
ꢀꢃ ꢂ ꢃꢃ
Nꢄ
ꢀꢃ
Nꢄ
ꢀꢃ
Nꢄ
ꢃꢃ
Nꢄ
ꢃꢃ
Nꢄ
RV2H Replacement Relay
1-Pole
2-Pole
ꢀꢂ
ꢁꢂ ꢁꢁ ꢁꢃ
ꢀꢂ
ꢁꢂ ꢁꢁ ꢁꢃ
ꢀꢁ
ꢁꢂ ꢁꢁ
ꢁꢃ
ꢀꢁ
ꢂꢂ ꢂꢁ ꢂꢃ
DIMENSIONS (
mm)
Screw Terminals
Spring Clamp Terminals
ꢅꢆ
ꢄꢅꢁꢀ
ꢅꢆ
ꢇꢇ
ꢇꢀ
ꢈꢀ
RV2H Replacement Relay (mm)
ꢀꢁꢂ0
ꢃꢀꢂ7
ꢀꢇ0ꢂꢄꢈ0ꢂꢄ
ꢆꢇ0ꢂꢄꢈ0ꢂꢉ
4
CHARACTERISTICS
Electrical Life Curve (AC Load)
1000
100
1 Pole
10
1
2 Pole
2
16
0 1
3 4 5
8
10
Contact Current (A)
Contact Rating
AC
DC
1 Pole
1 Pole
16
10
8
16
10
8
2 Pole
2 Pole
1
1
0.1
10
0.1
20 30
40 50
100 200
300 400
500
10
20 30
40 50
100 200
300 400
500
Contact Voltage (V)
Contact Voltage (V)
IDEC Canada
•
3155 Pepper Mill Court, Unit 4
•
Mississauga, Ontario, L5L 4X7, Canada
•
888-317-IDEC (4332) • Fax: 905-890-8562 • www.IDEC.com/canada
©2015 IDEC Corporation. All Rights Reserved.
RV9Y-DS300-0a-CA
pdf only
5