Infineon-Technologies-BCR-512-E6327
| Part # | Infineon-Technologies-BCR-512-E6327 |
| Download | Infineon-Technologies-BCR-512-E6327 |
BCR512
NPN Silicon Digital Transistor
•
Built in bias resistor (
R
= 4.7 k
Ω
,
R
= 4.7 k
Ω
)
•
Pb-free (RoHS compliant) package
•
Qualified according AEC Q101
1
2
2
1
3
C
3
R
1
R
2
1
2
B
E
EHA07184
Type
BCR512
Marking
XFs
Pin Configuration
Package
SOT23
1=B
2=E
3=C
Maximum Ratings
Parameter
Symbol
Value
Unit
50
50
V
Collector-emitter voltage
Collector-base voltage
Input forward voltage
Input reverse voltage
Collector current
V
V
V
V
CEO
CBO
i(fwd)
i(rev)
30
10
500
330
mA
mW
I
C
Total power dissipation-
P
tot
T
≤
79 °C
S
150
°C
Junction temperature
Storage temperature
T
j
T
-65 … 150
Thermal Resistance
Parameter
Junction – soldering point
Symbol
Value
≤
215
Unit
K/W
1)
R
thJS
1
For calculation of
R
please refer to Application Note AN077 (Thermal Resistance Calculation)
thJA
2011-07-28
1
BCR512
Electrical Characteristics
at
T
= 25°C, unless otherwise specified
Parameter
Symbol
Values
typ. max.
Unit
min.
DC Characteristics
Collector-emitter breakdown voltage
50
–
–
–
V
V
V
(BR)CEO
I
= 100 µA,
I
= 0
C
B
Collector-base breakdown voltage
I
= 10 µA,
I
= 0
50
–
–
–
–
–
(BR)CBO
C
E
Collector-base cutoff current
= 50 V,
I
= 0
I
100 nA
1.61 mA
CBO
V
CB
E
–
Emitter-base cutoff current
= 10 V,
I
= 0
I
EBO
V
EB
C
60
–
–
DC current gain-
I
= 50 mA,
V
= 5 V
h
FE
C
CE
1)
Collector-emitter saturation voltage
I
= 50 mA,
I
= 2.5 mA
V
–
0.6
1
–
–
–
0.3
1.5
2.2
V
CEsat
i(off)
C
B
Input off voltage
I
= 100 µA,
V
= 5 V
V
V
C
CE
Input on voltage
i(on)
I
= 10 mA,
V
= 0.3 V
C
CE
Input resistor
Resistor ratio
R
R
/
R
3.2
0.9
4.7
1
6.2 k
Ω
1
1.1
–
1
2
AC Characteristics
Transition frequency
–
100
–
MHz
f
T
I
= 50 mA,
V
= 5 V,
f
= 100 MHz
C
CE
1
Pulse test: t < 300µs; D < 2%
2011-07-28
2
BCR512
DC current gain
h
=
ƒ
(
I
)
Collector-emitter saturation voltage
FE
C
V
= 5 V (common emitter configuration)
V
=
ƒ
(
I
),
I /I
= 20
CE
CEsat
C
C B
10
3
0.5
V
0.4
0.35
0.3
10
2
-40 °C
-25 °C
25 °C
85 °C
125 °C
10
1
0.25
0.2
-40 °C
-25 °C
0.15
0.1
10
0
25 °C
85 °C
125 °C
0.05
0
10
-1
10
-4
10
-3
10
-2
10
-1
10
0
10
-3
10
-2
10
-1
10
0
A
A
I
I
C
C
Input on Voltage
V
i
=
ƒ
(
I
)
Input off voltage
V
=
ƒ
(
I
)
i(off) C
(on)
C
V
= 0.3V (common emitter configuration)
V
= 5V (common emitter configuration)
CE
CE
10
1
10
2
V
-40 °C
-40 °C
-25 °C
25 °C
V
-25 °C
25 °C
85 °C
125 °C
10
1
85 °C
125 °C
10
0
10
0
10
-1
10
-1
10
-4
10
-3
10
-2
10
-1
10
0
10
-5
10
-4
10
-3
10
-2
A
A
I
I
C
C
2011-07-28
3
BCR512
Total power dissipation
P
=
ƒ
(
T
)
Permissible Pulse Load
R
=
ƒ
(
t
)
tot
S
thJS
p
10
3
K/W
400
mW
10
2
300
250
200
150
100
50
10
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
D = 0
10
0
10
-1
0
10
-6
10
-5
10
-4
10
-3
10
-2
10
0
°C
s
0
20
40
60
80
100 120
150
T
t
p
S
Permissible Pulse Load
P
/
P
=
ƒ
(
t
)
totmax totDC
p
10
4
–
10
3
10
2
10
1
10
0
D = 0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10
-6
10
-5
10
-4
10
-3
10
-2
10
0
s
t
p
2011-07-28
4
Package SOT23
BCR512
Package Outline
0.1
1
0.1 MAX.
0.1
2.9
B
3
1
2
1)
+0.1
0.4
A
-0.05
0.08…0.15
0…8˚
C
0.95
1.9
0.25 B
C
1) Lead width can be 0.6 max. in dambar area
M
M
0.2
A
Foot Print
0.8
0.8
1.2
Marking Layout (Example)
Manufacturer
2005, June
Date code (YM)
EH
s
Pin 1
BCW66
T
y
pe code
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel
Reel ø330 mm = 10.000 Pieces/Reel
4
0.2
0.9
1.15
3.15
Pin 1
2011-07-28
5
BCR512
Edition 2009-11-16
Published by
Infineon Technologies AG
81726 Munich, Germany
2009 Infineon Technologies AG
All Rights Reserved.
Legal Disclaimer
The information given in this document shall in no event be regarded as a guarantee
of conditions or characteristics. With respect to any examples or hints given herein,
any typical values stated herein and/or any information regarding the application of
the device, Infineon Technologies hereby disclaims any and all warranties and
liabilities of any kind, including without limitation, warranties of non-infringement of
intellectual property rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices,
please contact the nearest Infineon Technologies Office (
<www.infineon.com>
).
Warnings
Due to technical requirements, components may contain dangerous substances.
For information on the types in question, please contact the nearest Infineon
Technologies Office.
Infineon Technologies components may be used in life-support devices or systems
only with the express written approval of Infineon Technologies, if a failure of such
components can reasonably be expected to cause the failure of that life-support
device or system or to affect the safety or effectiveness of that device or system.
Life support devices or systems are intended to be implanted in the human body or
to support and/or maintain and sustain and/or protect human life. If they fail, it is
reasonable to assume that the health of the user or other persons may be
endangered.
2011-07-28
6