KEMET-EE2-3SNUH

Part #KEMET-EE2-3SNUH
Download 
KEMET-EE2-3SNUH
Miniature Signal Relays  
EC2/EE2  
Overview  
Applications  
The KEMET EC2/EE2 miniature signal relays offer a  
compact case size in a slim package. Minimal board space  
is consumed with either a through-hole or surface mount  
configuration.ꢀTheseꢀrelaysꢀareꢀrecognizedꢀbyꢀULꢀandꢀCSA,ꢀ  
while also being compliant with Part 68 of the FCC’s 1,500  
V surge capacity.  
• Electronic
 
switching systems  
• PBX  
• Terminal
 
equipment  
• Telephone
 
systems  
Benefits  
• Low
 
power consumption (< 200 mW)  
• Compact
 
and lightweight  
• Low
 
magnetic interference  
• Tube
 
or embossed tape and reel packaging  
•ꢀ ULꢀrecognizedꢀ(E73266)ꢀandꢀCSAꢀcertifiedꢀ(LR46266)  
• Surface
 
mount and through-hole options  
• High
 
Breakdown Voltage (NKX) type can withstand 1.5  
kVAC at open contacts  
Part Number System  
EE2-  
3
S
NU  
Lead Type  
-L  
Series  
Coil Voltage  
Latch Type  
Packaging  
EC2- = Through-hole mount
 
3 = 3 VDC  
EE2- = Surface mount
 
4.5 = 4.5 VDC  
Blank = Non-latch type  
NU = Standard  
Blank = Tube  
S = Single coil latch type
 
NUH = Minimum footprint  
T = Double coil latch type
 
NUX = High solder joint reliability  
NKX = High breakdown voltage and  
high solder joint reliability  
-L = Embossed tape on reel  
L6 = Embossed carrying  
tape and Moisture barrier  
bag  
5 = 5 VDC  
9 = 9 VDC  
12 = 12 VDC  
24 = 24 VDC  
NQJ = High capability with maximum  
switch current at 2A  
NQX = High capability with maximum  
switch current at 2A and high solder  
joint reliability type  
Built Into Tomorrow  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
1

Miniature Signal Relays – EC2/EE2  
Dimensions – Millimeters  
EC2 Series  
Non-latch type and single coil latch type  
Double coil latch type  
B Maximum  
B Maximum  
D Maximum  
D Maximum  
H Maximum  
0.25  
H Maximum  
0.5  
K
0.5  
0.25  
K
P

1  

5.08  
P

1  

P

2  

5.08 P

1  

P

1

P

1  

P

2  

EE2 Series  
Non-latch type and single coil latch type  
Double coil latch type  
B Maximum  
B Maximum  
D Maximum  
D Maximum  
H Maximum  
0.25  
H Maximum  
0.25  
0.5  
0.5  
P

2  

P

3  

P

2  

P

3  

K
P

1  

5.08 P

1  

5.08  
P

1  

P

1

P

1  

K
Series  
D
H
B
P

1  

P

2  

P

3  

K
EC2 (NU)  
EC2 (NQJ)  
EE2 (NU)  
15.0  
15.0  
15.0  
15.0  
15.0  
9.4  
9.4  
7.5  
7.5  
7.5  
7.5  
7.5  
2.54  
2.54  
2.54  
2.54  
2.54  
5.08  
5.08  
5.08  
5.08  
5.08  
—
3.2  
2.8  
1.0  
—
10.0  
10.0  
10.35  
9.5  
7.5  
9.0  
EE2 (NUH)  
1.0  
EE2 (NUX, NKX, NQX)  
1.35  
General tolerance: ±0.2  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
2

Miniature Signal Relays – EC2/EE2  
Pin Configurations  
Bottom view  
Single coil latch type  
(Reset position)  
Double coil latch type  
(Reset position)  
Non-latch type  
(Non-energized position)  
1
3
4
5
1
3
4
5
1
3
4
5
6
+ –  
S R  
– +  
+
–
+
–
+
–
12  
10  
9
8
12  
10  
9
8
12  
10  
9
8
7
Reset coil  
S: Coil polarity for Set  
R: Coil polarity for Reset  
Set coil  
Safety Standards and Ratings  
Certification Body  
Mark  
Specification  
File Number  
Rating  
UL Recognized  
(UL508)

1  

UL  
E73266  
30 VDC, 2 A (resistive)  
110 VDC, 0.3 A (resistive)  
125 VAC, 0.5 A (resistive)  
CSAꢀCertified  
(CSA 22.2 #14)  
CSA  
LR46266  

1

Spacing: UL114, UL478  
Certification  
Mark  
Lead Type  
Specification  
File Number  
Class  
Rating  
Body  
Creepage and clearance  
of coil to contact is  
NU, NUH, NUX  
(Non-latch and Single coil)  
TUVꢀCertified  
(EN61810)  
TUV  
R 9751153  
Basic insulation  
more than 2 mm  
(According to EN60950)  
Environmental Compliance  
All KEMET relays are RoHS Compliant.  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
3

Miniature Signal Relays – EC2/EE2  
Table 1 – Ratings & Part Number Reference  
Part Number  
Nominal Coil Voltage  
Lead Type  
Packaging  
() Designates Latch Type  
(VDC)  
EC2-4.5(1)NU  
EC2-5(1)NU  
4.5  
5
Radial  
Radial  
Tube  
Tube  
EC2-12(1)NU  
EC2-24(1)NU  
EC2-3(1)NQJ  
EC2-4.5(1)NQJ  
EC2-5(1)NQJ  
EC2-9(1)NQJ  
EC2-12(1)NQJ  
EC2-24(1)NQJ  
EE2-3(1)NU  
12  
24  
3
4.5  
5
Radial  
Radial  
Tube  
Tube  
Tube  
Tube  
Tube  
Tube  
Tube  
Tube  
Radial, high capability with max.switch current at 2A  
Radial, high capability with max.switch current at 2A  
Radial, high capability with max.switch current at 2A  
Radial, high capability with max.switch current at 2A  
Radial, high capability with max.switch current at 2A  
Radial, high capability with max.switch current at 2A  
Surface mount  
9
12  
24  
3
Tube  
EE2-4.5(1)NU  
EE2-5(1)NU  
4.5  
5
Surface mount  
Surface mount  
Tube  
Tube  
EE2-12(1)NU  
12  
24  
3
4.5  
5
12  
24  
3
4.5  
5
12  
24  
3
4.5  
5
12  
24  
3
4.5  
5
12  
24  
3
4.5  
5
12  
24  
3
4.5  
12  
3
Surface mount  
Surface mount  
Surface mount  
Surface mount  
Surface mount  
Surface mount  
Surface mount  
Tube  
Tube  
EE2-24(1)NU  
EE2-3(1)NU-L  
EE2-4.5(1)NU-L  
EE2-5(1)NU-L  
EE2-12(1)NU-L  
EE2-24(1)NU-L  
EE2-3(1)NUH  
EE2-4.5(1)NUH  
EE2-5(1)NUH  
EE2-12(1)NUH  
EE2-24(1)NUH  
EE2-3(1)NUH-L  
EE2-4.5(1)NUH-L  
EE2-5(1)NUH-L  
EE2-12(1)NUH-L  
EE2-24(1)NUH-L  
EE2-3(1)NUX  
EE2-4.5(1)NUX  
EE2-5(1)NUX  
EE2-12(1)NUX  
EE2-24(1)NUX  
EE2-3(1)NUX-L  
EE2-4.5(1)NUX-L  
EE2-5(1)NUX-L  
EE2-12(1)NUX-L  
EE2-24(1)NUX-L  
EE2-3NKX

1  

Tape on Reel  
Tape on Reel  
Tape on Reel  
Tape on Reel  
Tape on Reel  
Tube  
Surface mount, Minimum footprint  
Surface mount, Minimum footprint  
Surface mount, Minimum footprint  
Surface mount, Minimum footprint  
Surface mount, Minimum footprint  
Surface mount, Minimum footprint  
Surface mount, Minimum footprint  
Surface mount, Minimum footprint  
Surface mount, Minimum footprint  
Surface mount, Minimum footprint  
Surface mount, High solder joint reliability  
Surface mount, High solder joint reliability  
Surface mount, High solder joint reliability  
Surface mount, High solder joint reliability  
Surface mount, High solder joint reliability  
Surface mount, High solder joint reliability  
Surface mount, High solder joint reliability  
Surface mount, High solder joint reliability  
Surface mount, High solder joint reliability  
Surface mount, High solder joint reliability  
Surface mount, High breakdown voltage, High solder joint reliability  
Surface mount, High breakdown voltage, High solder joint reliability  
Surface mount, High breakdown voltage, High solder joint reliability  
Surface mount, High breakdown voltage, High solder joint reliability  
Surface mount, High breakdown voltage, High solder joint reliability  
Surface mount, High breakdown voltage, High solder joint reliability  
Surface mount, High capability with maximum switch current at 2A,  
High solder joint reliability  
Tube  
Tube  
Tube  
Tube  
Tape on Reel  
Tape on Reel  
Tape on Reel  
Tape on Reel  
Tape on Reel  
Tube  
Tube  
Tube  
Tube  
Tube  
Tape on Reel  
Tape on Reel  
Tape on Reel  
Tape on Reel  
Tape on Reel  
Tube  
EE2-4.5NKX

1  

EE2-12NKX

1  

EE2-3NKX-L

1  

EE2-4.5NKX-L

1  

EE2-12NKX-L

1  

Tube  
Tube  
Tape on Reel  
Tape on Reel  
Tape on Reel  
Embossed carrying tape and  
Moisture barrier bag  
Embossed carrying tape and  
Moisture barrier bag  
Embossed carrying tape and  
Moisture barrier bag  
Embossed carrying tape and  
Moisture barrier bag  
Embossed carrying tape and  
Moisture barrier bag  
Embossed carrying tape and  
Moisture barrier bag  
4.5  
12  
EE2-3(1)NQX-L6  
EE2-4.5(1)NQX-L6  
EE2-5(1)NQX-L6  
EE2-9(1)NQX-L6  
EE2-12(1)NQX-L6  
EE2-24(1)NQX-L6  
3
4.5  
5
Surface mount, High capability with maximum switch current at 2A,  
High solder joint reliability  
Surface mount, High capability with maximum switch current at 2A,  
High solder joint reliability  
Surface mount, High capability with maximum switch current at 2A,  
High solder joint reliability  
Surface mount, High capability with maximum switch current at 2A,  
High solder joint reliability  
9
12  
24  
Surface mount, High capability with maximum switch current at 2A,  
High solder joint reliability  
Part Number  
Nominal Coil Voltage  
Lead Type  
Packaging  
(1) To complete KEMET part number, leave blank for Non-latch, insert S for Single coil, or T for Double coil. Designates latch type.  

1

NKX type only available as Non-latch. Non-standard part, please contact KEMET to special order.  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
4

Miniature Signal Relays – EC2/EE2  
Land Pattern – Millimeters  
EC2 Series (bottom view)  
Non-latch type and single coil latch type  
Double coil latch type  
8 – ø 0.8  
8 – ø 0.8  
2.54  
5.08 2.54  
1.05  
2.54 2.54  
5.08 2.54  
1.05  
V
V
1.11  
1.11  
EE2 Series (top view)  
Non-latch type and single coil latch type  
Double coil latch type  
2.54 2.54  
5.08 2.54  
1.05  
2.54  
5.08 2.54  
1.05  
V
V
X
X
1.11  
1.11  
Series  
EC2  
V
X
—
5.08  
7.29  
6.29  
7.02  
EE2 (NU)  
EE2 (NUH)  
3.0  
2.0  
2.73  
EE2 (NUX, NKX)  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
5

Miniature Signal Relays – EC2/EE2  
Soldering Process  
EC2 – Through-hole Mounting  
Automatic Soldering  
Preheating: 110–120°C/110 seconds (maximum)  
Solder temperature: 260°C maximum  
Solder time: 5 seconds maximum  
Note: KEMET recommends cooling down a printed circuit board to less than 110°C within 40 seconds after soldering.  
Manual Soldering  
Solder temperature: 350°C maximum  
Solder time: 3 seconds maximum  
EE2 – Surface Mounting  
IRS Method  
Temperature  
(˚
C)  
Maximum 240
˚
C  
220  
200  
180  
45 (Maximum 70)  
Time (seconds)  
70 (Maximum 120)  
190 (Maximum 300)  
ꢀ
ꢀ
Note:ꢀTemperatureꢀprofileꢀshowsꢀprintedꢀcircuitꢀboardꢀsurfaceꢀtemperatureꢀonꢀtheꢀrelayꢀterminalꢀportion.  
PleaseꢀconsultꢀKEMETꢀifꢀyouꢀwishꢀtoꢀuseꢀaꢀtemperatureꢀprofileꢀotherꢀthanꢀabove.  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
6

Miniature Signal Relays – EC2/EE2  
Contact Specifications  
Item  
EC2/EE2  
Contact Form  
2 Form C  
Contact Material  
Silver alloy with gold alloy overlay  
60 W, 125 VA  
Maximum Switching Power  
Maximum Switching Voltage  
Maximum Switching Current  
Maximum Carrying Current  
220 VDC, 250 VAC  
2 A  
Contact Ratings  
2 A  
Minimum Contact Ratings  
Initial Contact Resistance  
Operating Time (excluding bounce)  
Release Time (excluding bounce)  
Insulation Resistance  
10 mVDC, 10 µA*

1  

75ꢀmΩꢀmaximumꢀ(initial)  
Approximately 2 milliseconds  
Approximately 1 millisecond  
1,000ꢀMΩꢀatꢀ500ꢀVDC  
NU, NUH, NUX:  
1,000 VAC (for one minute), 1,500 V surge (10 x 160 µs)*

2  

Between Open Contacts  
NKX:  
Make contact: 1,500 VAC (for one minute), 2,500 V surge (2 x 10 µs)*

3  

Break contact: 1,000 VAC (for one minute), 1,500 V surge (10 x 160 µs)*

2  

Withstand Voltage  
Between Adjacent Contacts  
Between Coil and Contacts  
1,000 VAC (for one minute), 1,500 V surge (10 x 160 µs)

*2  

Non-latch and single coil latch type:  
1,500 VAC (for one minute), 2,500 V surge (2 x 10 µs)

*3  

Double coil latch type:  
1,000 VAC (for one minute), 1,500 V surge (10 x 160 µs)

*2  

735 m/s

2

(75 G) – misoperation  
Shock Resistance  
980 m/s

2

(100 G) – destructive failure  
10 to 55 Hz, double amplitude 3 mm (20 G) – misoperation  
10 to 55 Hz, double amplitude 5 mm (30 G) – destructive failure  
Vibration Resistance  
Ambient Temperature  
Coil Temperature Rise  
−40ꢀtoꢀ+85°C  
18°C at nominal coil voltage (140 mW)  
1 x 10

8

operations (Non-latch type)

*4  

Non-load  
Load  
1 x 10

7

operations (Latch type)  
RunningꢀSpecifications  
50 VDC 0.1 A (resistive), 1 x 10

6

operations at 85°C, 5 Hz  
10 VDC 10 mA (resistive), 1 x 10

6

operations at 85°C, 2 Hz  
Weight  
Approximately 1.9 g  

*1

This value is a reference value in the resistance load. Minimum capacity changes depending on the switching frequency, environment temperature,  
and load.  

*2

Rise time: 10 µs; decay time to half crest: 160 µs.  

*3

Rise time: 2 µs; decay time to half crest: 10 µs.  

*4

This shows the number of operations with fatal defects. Stable characteristics are maintained for 1 x 10

7

operations.  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
7

Miniature Signal Relays – EC2/EE2  
Coil Specifications  
Non-latch Type (at 20°C)  
Nominal Coil Voltage  
(VDC)  
Coil Resistance  
(Ω) ±10%  
Operating Voltage

1  

(VDC)  
Release Voltage

1  

(VDC)  
Nominal Operating  
Power (mW)  
3.0  
4.5  
64.3  
145.0  
2.25  
3.38  
3.75  
6.75  
9.00  
18.00  
0.30  
0.45  
0.50  
0.90  
1.20  
2.40  
140  
140  
140  
140  
140  
200  
5.0  
178.0  
9.0  
579.0  
12.0  
24.0  
1,028.0  
28,800.0  

1

Test by pulse voltage.  
Single Coil Latch Type (at 20°C)

2  

Nominal Coil Voltage  
(VDC)  
Coil Resistance  
(Ω) ±10%  
Set Voltage

1  

(VDC)  
Reset Voltage

1  

(VDC)  
Nominal Operating  
Power (mW)  
3.0  
4.5  
90.0  
202.5  
2.25  
3.38  
3.75  
6.75  
9.00  
18.00  
2.25  
3.38  
3.75  
6.75  
9.00  
18.00  
100  
100  
100  
100  
100  
150  
5.0  
250.0  
9.0  
810.0  
12.0  
24.0  
1,440.0  
3,840.0  

1

Test by pulse voltage.  

2

ꢀLatchꢀtypeꢀrelaysꢀshouldꢀbeꢀinitializedꢀtoꢀaꢀknownꢀpositionꢀbeforeꢀusing.ꢀOnlyꢀtheꢀspecifiedꢀpolarityꢀshouldꢀbeꢀusedꢀtoꢀenergizeꢀtheꢀcoil.  
Double Coil Latch Type (at 20°C)

2,3  

Nominal Coil Voltage  
(VDC)  
Coil Resistance  
(Ω) ±10%  
Set Voltage

4  

(VDC)  
Release Voltage

4  

(VDC)  
Nominal Operating  
Power (mW)  
S
R
S
R
S
R
S
R
S
R
S
R
64.3  
64.3  
145  
2.25  
–
–
2.25  
–
3
4.5  
5
140  
140  
140  
140  
140  
200  
3.38  
–
145  
3.38  
–
178  
3.75  
–
178  
3.75  
–
579  
6.75  
–
9
579  
6.75  
–
1,028  
1,028  
2,880  
2,880  
9.0  
–
12  
24  
9.0  
–
18.0  
–
18.0  

2

ꢀLatchꢀtypeꢀrelaysꢀshouldꢀbeꢀinitializedꢀtoꢀaꢀknownꢀpositionꢀbeforeꢀusing.ꢀOnlyꢀtheꢀspecifiedꢀpolarityꢀshouldꢀbeꢀusedꢀtoꢀenergizeꢀtheꢀcoil.  

3

Can not be driven by reverse polarity for reverse operation.  

4

S = Set coil [pin #1 (+), pin #12 (
−
)], R = Reset coil [pin #6 (+), pin #7 (
−
)].  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
8

Miniature Signal Relays – EC2/EE2  
Coil Specifications cont.  
Non-latch, High Breakdown Voltage (NKX) Type (at 20°C)  
Nominal Coil Voltage  
(VDC)  
Coil Resistance  
Operating Voltage

1  

(VDC)  
Release Voltage

1  

(VDC)  
Nominal Operating  
Power (mW)  
(Ω) ±10%  
3.0  
4.5  
39.1  
88.0  
2.25  
3.38  
9.00  
0.30  
0.45  
1.20  
230  
230  
230  
12.0  
626.0  

1

Test by pulse voltage.  
Recommended Relay Drive Conditions  
Coil Type  
Rating  
Ambient Temperature  
Non-latch  
Voltage:ꢀ≤ꢀ±5%ꢀofꢀnominalꢀvoltage  
Square pulse (rise and fall time is rapid)  
Pulseꢀheight:ꢀ≤ꢀ±5%ꢀofꢀnominalꢀvoltage  
Pulse Width: > 10 ms  
−40ꢀtoꢀ+85°C  
Single Coil  
Double Coil  
Marking  
EC2 – Top View  
EE2 – Top View  
ꢀart ꢁuꢂꢃer  
ꢀart ꢁuꢂꢃer  
Manuꢄaꢅturer  
ꢈireꢅtiꢆn Marꢊ  
ꢋꢀin ꢁꢆꢌ ꢍ anꢉ ꢎꢏ  
ꢈireꢅtiꢆn Marꢊ  
ꢋꢀin ꢁꢆꢌ ꢍ anꢉ ꢎꢏ  
ꢐꢑꢒ CSꢓ Marꢊing  
ꢈate Cꢆꢉe  
ꢐꢑꢒ CSꢓ Marꢊing  
ꢈate Cꢆꢉe  
Cꢆuntry ꢆꢄ ꢇrigin  
Cꢆuntry ꢆꢄ ꢇrigin  
Manuꢄaꢅturer  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
9

Miniature Signal Relays – EC2/EE2  
Performance Data  
Coil Temperature Rise  
Temperature is measured by coil resistance  
Coil temperature  
Coil temperature  
rise (
℃
)  
Applied power 0.2W  
60  
30  
rise (
℃
)  
Applied power 0.14W  
Applied power 0.1W  
40  
20  
0
20  
10  
0
0
100  
200  
300  
0
5
10  
15  
20  
Applied power (mW)  
Applied time (minute)  
Switching Capacity  
Maximum Coil Voltage  
Maximum Values  
Maximum value of permissible alteration  
2.0  
200  
1.0  
Ratio  
nominal  
coil  
o
Ratio of  
nominal  
coil  
Contact  
150  
100  
50  
current (A)  
0.5  
voltage  
(%)  
voltage  
(%)  
0.2  
0.1  
DC(Resistive)  
AC(Resistive)  
10  
20  
50  
100  
-40 -20  
0
20  
40  
60 80 100  
250VAC  
220VDC  
0VAC  
20VDC  
Ambient temperature (
℃
)  
Contact voltage (V)  
Applied Voltage vs. Timing  
(Sample: EE2–5NU)  
(Without coil diode)  
4
4
3
2
1
3
Release  
Operate  
2
time  
(ms)  
time  
(ms)  
1
0
0
0
100  
150  
200  
250  
0
100  
200  
300  
400  
Applied power (mW)  
Applied power (mW)  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
10  

Miniature Signal Relays – EC2/EE2  
Performance Data cont.  
Operate and Release Voltage vs. Ambient Temperature  
This shows a typical change of operate (release) voltage. The value of must operate is estimated, so coil voltage must be  
applied higher than this value for safe operation. For hot start operation, please inquire with KEMET.  
100  
Must operate voltage  
80  
60  
40  
20  
0
Operate voltage (typical)  
Ratio of nominal  
coil voltage (%)  
Release voltage (typical)  
-40  
-20  
0
20  
40  
60  
80  
100  
Ambient temperature (°C)  
Running Test (Non-load)  
(Load:ꢀnone;ꢀDrive:ꢀ5ꢀVDC,ꢀ50ꢀHz,ꢀ50%ꢀduty;ꢀAmbientꢀTemperature:ꢀroomꢀtemperature;ꢀSample:ꢀEE2–5NU,ꢀ20ꢀpieces)  
10000  
5
Operate voltage  
Release voltage  
1000  
100  
10  
4
3
2
1
0
Contact  
resistance  
(m
Ω
)  
Operate  
voltage  
(V)  
Release  
voltage  
(V)  
0
20  
50  
100  
500  
1000  
0
20  
50  
100  
500  
1000  
Operations (
×
10

4

)  
Operations (
×
10

4

)  
Running Test (Load)  
(Load:ꢀ50ꢀVDC,ꢀ0.1ꢀAꢀresistive;ꢀDrive:ꢀ5ꢀVDC,ꢀ5ꢀHz,ꢀ50%ꢀduty;ꢀAmbientꢀTemperature:ꢀ85°C;ꢀSample:ꢀEE2–5NU,ꢀ10ꢀpieces)  
5
4
3
2
1
0
10000  
1000  
100  
Operate voltage  
Contact  
resistance  
(m
Ω
)  
Operate  
voltage  
(V)  
Release voltage  
Release  
0
2
5
10  
50  
100  
10  
Operations (
×
10

4

)  
0
2
5
10  
50  
100  
Operations (
×
10

4

)  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
11  

Miniature Signal Relays – EC2/EE2  
Performance Data cont.  
Breakdown Voltage  
(Sample: EE2–5NU, 10 pieces)  
(a) Between open contacts  
(b) Between adjacent contacts  
100  
100  
50  
50  
0
Distribution  
Distribution (%)  
0
0.5  
1.0  
1.5  
2.0  
1.0  
1.5  
2.0  
2.5  
Breakdown voltage (K V)  
Breakdown voltage (K V)  
(C) Between coil and contact  
100  
50  
0
Distribution (%)  
0.5  
1.5  
2.0  
2.5  
Breakdown voltage (K V)  
Alteration of Voltage in Dense Mounting  
(magnetic interference)  
Alternation of operate voltage  
Alternation of operate voltage  
+40  
+30  
+20  
+10  
0
+40  
+30  
+20  
+10  
0
Ratio of  
Ratio of  
alternation (%)  
alternation (%)  
-10  
-20  
-30  
-40  
-10  
-20  
-30  
-40  
a
b
c
d
e
f
a
b
c
d
e
f
Mounting layout  
Mounting layout  
Device under test  
OFF  
OFF  
ON  
ON  
2.54  
mm  
2.54mm  
OFF  
ON  
ON  
OFF  
a
b
c
d
2.54  
mm  
ON  
ON  
ON  
OFF  
OFF  
OFF  
e
f
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
12  

Miniature Signal Relays – EC2/EE2  
Tube Packing – Millimeters  
35 pieces/Tube (anti-static)  
15.5  
543  
Direction of relay direction mark  
11.9  
Rubber stopper (Green)  
Rubber stopper (Red)  
Tape & Reel Packaging Information (EE2 only) – Millimeters  
Appearance  
Reel  
500 pieces/Reel  
Reel diameter: 380mm  
Emboss  
Carrying tape  
Top cover tape  
Tape Dimensions  
A
1.75  
2.0  
0.4  
16  
4
Φ
1.5  
Φ
2.2  
Series  
A
B
11.5  
NU-L, NUX-L,  
NKX-L  
Maximum 10.9  
Maximum 11.1  
10.0  
8.0  
1
5
.5  
24.0  
NUH-L  
B
Relay Direction Mark and Tape Carrying Direction  
Sprocket hole  
Direction mark  
Direction of unreeling  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
13  

Miniature Signal Relays – EC2/EE2  
Notes on Using Relays  
1. Contact Load  
Makeꢀsureꢀthatꢀtheꢀcontactꢀloadꢀisꢀwithinꢀtheꢀspecifiedꢀrange;ꢀotherwise,ꢀtheꢀlifetimeꢀofꢀtheꢀcontactsꢀwillꢀbeꢀshortenedꢀ  
considerably. Note that the running performance shown is an example, and that it varies depending on parameters such  
as the type of load, switching frequency, driver circuit, and ambient temperature under the actual operating conditions.  
2. Driving Relays  
•
Ifꢀtheꢀinternalꢀconnectionꢀdiagramꢀofꢀaꢀrelayꢀshowsꢀ+ꢀandꢀ-ꢀsymbolsꢀonꢀtheꢀcoil,ꢀapplyꢀtheꢀratedꢀvoltageꢀtoꢀtheꢀrelayꢀinꢀ  
theꢀspecifiedꢀdirection.ꢀIfꢀaꢀrippledꢀDCꢀcurrentꢀsourceꢀisꢀused,ꢀabnormalitiesꢀsuchꢀasꢀheatꢀatꢀtheꢀcoilꢀmayꢀoccur.  
• The
 
maximum voltage that can be applied to the coil of the relay varies depending on the ambient temperature.  
Generally, the higher the voltage applied to the coil, the shorter the operating time. Note, however, that high voltage  
also increases the bounce of the contacts and the contact opening and closing frequency, which may shorten the  
lifetime of the contacts.  
Nominal  
coil voltage  
0
<1msec.  
<1msec.  
• For
 
consistent operation, the driving voltage should have rise and fall times of less than 1 ms.  
•
Forꢀaꢀlatchingꢀrelay,ꢀapplyꢀaꢀvoltageꢀtoꢀtheꢀcoilꢀaccordingꢀtoꢀtheꢀpolarityꢀspecifiedꢀinꢀtheꢀinternalꢀconnectionꢀdiagramꢀofꢀ  
the relay.  
• If
 
a current is applied to the coil over a long period of time, the coil temperature rises, promoting generation of organic  
gas inside the relay, which may result in faulty contacts. In this case, use of a latching relay is recommended.  
• The
 
operating time and release time indicate the time required for each contact to close after the voltage has been  
applied to or removed from the coil. However, because the relay has a mechanical structure, a bounce state exists  
at the end of the operating and release times. Furthermore, because additional time is required until the contact  
stabilizes after being in a high-resistance state, care must be taken when using the relay at high speeds.  
3. Operating Environment  
•
Makeꢀsureꢀthatꢀtheꢀrelayꢀmountedꢀinꢀtheꢀapplicationꢀsetꢀisꢀusedꢀwithinꢀtheꢀspecifiedꢀtemperatureꢀrange.ꢀUseꢀofꢀaꢀrelayꢀ  
at a temperature outside this range may adversely affect insulation or contact performance.  
•
Ifꢀtheꢀrelayꢀisꢀusedꢀforꢀaꢀlongꢀperiodꢀofꢀtimeꢀinꢀhighlyꢀhumidꢀ(RHꢀ85%ꢀorꢀhigher)ꢀenvironment,ꢀmoistureꢀmayꢀbeꢀ  
absorbed into the relay. This moisture may react with the NOx and SOx generated by glow discharges that occur when  
the contacts are opened or closed, producing nitric or sulfuric acid. If this happens, the acid produced may corrode  
the metallic parts of the relay, causing operational malfunction.  
• If
 
any material containing silicon (silicon rubber, silicon oil, and silicon based coating material) is used in the  
neighborhood of relay, there is some possibility that these materials will emit silicon gas that will penetrate the  
relay. In this case, the switching contact may generate silicon compounds on the surface of contacts. This silicon  
compound may result in contact failure. Avoid use of relay in such an environment.  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
14  

Miniature Signal Relays – EC2/EE2  
Notes on Using Relays cont.  
• Because
 
the operating temperature range varies depending on the humidity, use the relay in the temperature range  
illustratedꢀinꢀtheꢀfigureꢀbelow.ꢀPreventꢀtheꢀrelayꢀfromꢀbeingꢀfrozenꢀandꢀavoidꢀtheꢀgenerationꢀofꢀcondensation.  
85  
80  
60  
Humidity  
(%RH)  
40  
20  
5
-60 -40 -20  
0 20 40
 
60 80
 
100  
T
e
mperature (
°C
)  
• The
 
relay maintains constant sealability under normal atmospheric pressure (810 to 1,200 hpa). Its sealability may  
be degraded or the relay may be deformed and malfunction if it is used under barometric conditions exceeding the  
specifiedꢀrange.  
• The
 
same applies when the relay is stored or transported. Keep the upper-limit value of the temperature to which the  
relay is exposed after it is removed from the carton box to within 50°C.  
• Permanent
 
magnets are used in polarized relays. For this reason, when magnets, transformers, or speakers are  
located nearby the relay characteristics may change and faulty operations may result.  
• If
 
excessive vibration or shock is applied to the relay, it may malfunction and the contacts remain closed. Vibration or  
shock applied to the relay during operation may cause considerable damage to or wearing of the contacts. Note that  
operation of a snap switch mounted close to the relay or shock due to the operation of magnetic solenoid may also  
cause malfunctioning.  
4. Mounting  
• When
 
mounting a relay onto a PC board using an automatic chip mounter, if excessive force is applied to the cover  
of the relay when the relay is chucked or inserted, the cover may be damaged or the characteristics of the relay  
degraded. Keep the force applied to the relay to within 1 kg.  
• Avoid
 
bending the pins to temporarily secure the relay to the PC board. Bending the pins may degrade sealability or  
adversely affect the internal mechanism.  
• Ventilation
 
immediately after soldering is recommended. Avoid immersing the relay in cleaning solvent immediately  
after soldering due to the danger of thermal shock being applied to the relay.  
• Use
 
an alcohol-based or water-based cleaning solvent. Never use thinner and benzene because they may damage the  
relay housing.  
• Do
 
not use ultrasonic cleaning because the vibration energy generated by the ultrasonic waves may cause the  
contacts to remain closed.  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
15  

Miniature Signal Relays – EC2/EE2  
Notes on Using Relays cont.  
5. Handling and Storage  
• Relays
 
are packaged in magazine cases for shipment. If a space is created in the case after some relays have been  
removed, be sure to insert a stopper to secure the remaining relays in the case. If relays are not well secured, vibration  
during transportation may cause malfunctioning of the contacts.  
• Exercise
 
care in handling the relay so as to avoid dropping it or allowing it to fall. Do not use a relay that has been  
dropped.ꢀIfꢀaꢀrelayꢀdropsꢀfromꢀaꢀworkbenchꢀtoꢀtheꢀfloor,ꢀaꢀshockꢀofꢀ9,800ꢀm/s

2

(1,000 G) or more is applied to the relay,  
possibly damaging its functions. Even if a light shock has been applied to the relay, thoroughly evaluate its operation  
before using it.  
• Latching
 
relays are factory-set to reset state for shipment. A latching relay may be set, however, by vibration or shock  
applied while being transported. Be sure to forcibly reset the relay before using it in the application set. Also note that  
the relay may be set by unexpected vibration or shock when it is used in a portable set.  
• The
 
sealability of a surface mount (SMT) relay may be lost if the relay absorbs and is then heated during soldering.  
When storing relays, therefore, observe the following points:  
1.
ꢀForꢀstandardꢀpacking,ꢀpleaseꢀuseꢀrelaysꢀwithinꢀ12ꢀmonthsꢀafterꢀdeliveryꢀ(storageꢀconditions:ꢀ30°C/60%ꢀRH).ꢀIfꢀtheꢀ  
relays have moisture absorption, dehumidify as follows:  
–ꢀTapeꢀPackaging:ꢀ50ꢀ±5°C,ꢀ200–300ꢀhours.  
–ꢀSimpleꢀRelay:ꢀ85ꢀ±5°C,ꢀ48ꢀhours.  
2.
ꢀForꢀMBBꢀpacking,ꢀpleaseꢀuseꢀrelaysꢀwithinꢀ2ꢀyearsꢀafterꢀdeliveryꢀ(storageꢀconditions:ꢀ30°C/60%ꢀRH).ꢀAfterꢀ  
openingꢀMBBꢀpacking,ꢀpleaseꢀuseꢀwithinꢀ3ꢀmonthsꢀ(storageꢀconditions:ꢀ30°C/60%ꢀRH).  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
16  

Miniature Signal Relays – EC2/EE2  
KEMET Electronics Corporation Sales Offices  
Disclaimer  
Allꢀproductꢀspeci ꢀcations,ꢀstatements,ꢀinformationꢀandꢀdataꢀ(collectively,ꢀtheꢀ“Information”)ꢀinꢀthisꢀdatasheetꢀareꢀsubjectꢀtoꢀchange.ꢀTheꢀcustomerꢀisꢀresponsibleꢀforꢀ  
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given  
herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.  
StatementsꢀofꢀsuitabilityꢀforꢀcertainꢀapplicationsꢀareꢀbasedꢀonꢀKEMETꢀElectronicsꢀCorporation’sꢀ(“KEMET”)ꢀknowledgeꢀofꢀtypicalꢀoperatingꢀconditionsꢀforꢀsuchꢀ  
applications,ꢀbutꢀareꢀnotꢀintendedꢀtoꢀconstituteꢀ–ꢀandꢀKEMETꢀspeci ꢀcallyꢀdisclaimsꢀ–ꢀanyꢀwarrantyꢀconcerningꢀsuitabilityꢀforꢀaꢀspeci ꢀcꢀcustomerꢀapplicationꢀorꢀuse.ꢀ  
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any  
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no  
obligation or liability for the advice given or results obtained.  
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component  
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards  
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or  
property damage.  
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other  
measures may not be required.  
When providing KEMET products and technologies contained herein to other countries,
 
the customer must abide by the procedures and provisions stipulated in all  
applicableꢀexportꢀlawsꢀandꢀregulations,ꢀincludingꢀwithoutꢀlimitationꢀtheꢀInternationalꢀTra ꢀꢀcꢀinꢀArmsꢀRegulationsꢀ(ITAR),ꢀtheꢀUSꢀExportꢀAdministrationꢀRegulationsꢀ  
(EAR) and the Japan Foreign Exchange and Foreign Trade Act.  
KEMET is a registered trademark of KEMET Electronics Corporation.  
© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard  
R7002_EC2_EE2 • 12/7/2020  
17