KEMET-EFA-01-240X240T0800

Part #KEMET-EFA-01-240X240T0800
Download 
KEMET-EFA-01-240X240T0800
Flex Suppressor

®  

EF Series  
Overview  
Applications  
The EF Series Flex Suppressor

®

is an effective suppressor  
for high frequency noise generated from electronic devices.  
Theꢀflexibleꢀsheetꢀisꢀaꢀpolymerꢀbaseꢀblendedꢀwithꢀmicronꢀ  
sized magnetic powders dispersed into the material. The EF  
Series are effective for resonance and wave suppression,  
and can be cut into virtually any shape.  
• Radiation
 
noise suppression for electronic equipment  
• Quasi-microwave
 
range interference prevention inside  
and in between electronics  
• Mobile
 
communications equipment, wireless equipment  
(Wi-Fi,ꢀBluetooth),ꢀofficeꢀautomationꢀequipmentꢀ(personalꢀ  
computers, TFT LCD’s etc.), communication terminals in  
audio/video equipment, digital exchanges, etc.  
• ESD
 
(electro static discharge) countermeasure  
Benefits  
• Usable
 
in quasi-microwave ranges  
• Can
 
be used in high-speed clocks (Up to 10 GHz)  
•ꢀ Thin,ꢀflexibleꢀmaterialꢀusedꢀinꢀportableꢀequipment  
• Virtually
 
no limitation in where it can be used  
• Less
 
time required for installation  
• Resonance
 
suppression – controls the high frequency  
current and suppresses unwanted electromagnetic  
resonance by creating impedance  
• Electromagnetic
 
wave suppression – suppresses the  
electromagnetic wave intruding the sheet by the magnetic  
loss of its composition  
Part Number System  
EFR  
(01)-  
240×240  
T08  
00  
Standard Dimensions  
(mm)  
Tape 1 Type  
Adhesive Tape Thickness  
Series Type  
Thickness  
Tape 2 Type  
EFR  
EFX  
EFF  
EFA  
EFH  
EFG  
(003)- = 0.03 mm  
(005)- = 0.05 mm  
(007)- =0.07 mm  
(01)- = 0.1 mm  
(02)- = 0.2 mm  
(03)- = 0.3 mm  
(05)- = 0.5 mm  
(10)- = 1.0 mm  
240 x 240  
T08 = 0.03 mm  
T15 = 0.14 mm  
T22 = 0.05 mm  
T29 = 0.01 mm  
00 = Without PET tape  
Blank = Without Tape 1 Type  
Blank = No adhesive tape  
One world. One KEMET  
FS8001_EF • 3/27/2017  
1

Flex Suppressor

®  

EF Series  
Specifications  
Flame  
High  
Magnetic  
Specifications Permeability  
Type  
Extra High  
Magnetic  
Permeability  
Type  
Retardant  
Type, Red  
Phosphorus  
Free Type  
High  
Temp.  
Reflow  
Standard  
High  
Frequency  
Features  
Type  
EFR  
EFX  
EFF  
EFA  
EFG  
EFH  
Effective Frequency  
Up to 10 GHz  
−40ꢀtoꢀ+105  
Operating Temperature (°C)  
Thickness (mm)  
0.05/0.1/0.2/  
0.3/0.5/1.0  
0.05/0.1/0.2/  
0.3/0.5  
0.03/0.05/0.1/  
(0.2/0.3)

2  

0.05/0.1/  
0.2/0.3  
0.07/0.1/0.2/0.3  
0.05/0.1  
240 x 240  
(roll on request)  
Standard Dimensions (mm)  
240 x 240  
240 x 240  
SpecificꢀGravity

1  

2.8 typical  
3.2 typical  
3.6 typical  
3.1 typical  
3.0 typical  
3.1 typical  
Tensile Strength (Mpa)  
3.6 minimum  
6.8 minimum  
6.9 minimum  
6.8 minimum  
3.5 minimum
 
6.8 minimum  
1.0 x 10

5  

minimum  
1.0 x 10

6  

minimum  
SurfaceꢀResistanceꢀ(Ω)
1.0 x 10

6

minimum 1.0
 
x 10

5

minimum 1.0
 
x 10

5

minimum 1.0
 
x 10

6

minimum  
Thermal Conductivity (W/m K)  
0.22  
0.22  
0.4  
1.3  
0.22  
1.3  
UL94 V–0  
UL94 HB  
UL94 V–0  
UL94 V–1  
UL94 V–0  
Approved Standard  
UL File No.  
E176124  
UL File No. E176124  
RoHS  
Compliant  
Halogen  
Free  
Free  
Free  
PVC  
Environment  
Lead  
Red  
Phosphorus  
—
Free  
—
Free  
—
Free  
Relative Magnetic Permeability  
(at 3 MHz)  
60 typical  
100 typical  
130 typical  
60 typical  
20 typical  
60 typical  
Industry’s  
highest magnetic  
permeability of µ130
 
permeability. Red  
with halogen free
 
phosphorus free  
Various thickness
 
composition. Flame
 
Flame retardant (UL  
retardant(UL 94 V–0
 
94ꢀV–0ꢀcertified)  
certified)  
Excellent  
suppression of  
high frequency
 
mounted  
noise in Wi-Fi  
and higher  
µ60 high  
µ60 high permeability  
Various thickness  
Flame retardant (UL  
94ꢀV–0ꢀcertified)  
Can be  
µ100 high  
permeability  
Remarks  
before  
reflowing  
bandwidths.  
Above specifications are for the Flex Suppressor

®

alone (adhesives and etc. not included)  

1

Value in 23°C atmosphere  

2

Sheets with 0.2 mm and 0.3 mm thickness are lamination of 0.1 mm sheets.  
FS8001_EF • 3/27/2017  
2

Flex Suppressor

®  

EF Series  
Table 1 – Ratings & Part Number Reference  
Relative  
Magnetic  
Permeability  
at 3 MHz  
Tensile  
Strength  
(Mpa  
minimum)  
3.6  
Tape  
Thickness  
(mm)  
Specific  
Gravity  
(typical)  
Surface  
Resistance Conductivity  
(Ω minimum)  
Thermal  
Thickness  
(mm)  
Part Number  
Series  
(W/m K)  
EFR(005)-240x240T0800  
EFR(01)-240x240T0800  
EFR(02)-240×240  
EFR  
EFR  
EFR  
EFR  
EFR  
EFR  
EFR  
EFR  
EFR  
EFR  
EFX  
EFX  
EFX  
EFX  
EFX  
EFX  
EFX  
EFX  
EFF  
EFF  
EFF  
EFF  
EFF  
EFF  
EFA  
EFA  
EFA  
EFA  
EFA  
EFA  
EFA  
EFG  
EFG  
EFG  
EFG  
EFG  
EFG  
EFH  
EFH  
0.05  
0.1  
0.2  
0.2  
0.3  
0.3  
0.5  
0.5  
1
0.03  
0.03  
—  
60  
2.8  
2.8  
2.8  
2.8  
2.8  
2.8  
2.8  
2.8  
2.8  
2.8  
3.2  
3.2  
3.2  
3.2  
3.2  
3.2  
3.2  
3.2  
3.6  
3.6  
3.6  
3.6  
3.6  
3.6  
3.1  
3.1  
3.1  
3.1  
3.1  
3.1  
3.1  
3
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^6  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^5  
1.0 x 10^6  
1.0 x 10^6  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
0.4  
60  
3.6  
60  
3.6  
EFR(02)-240x240T0800  
EFR(03)-240×240  
0.03  
—  
60  
3.6  
60  
3.6  
EFR(03)-240x240T0800  
EFR(05)-240×240  
0.03  
—  
60  
3.6  
60  
3.6  
EFR(05)-240x240T1500  
EFR(10)-240×240  
0.14  
—  
60  
3.6  
60  
3.6  
EFR(10)-240x240T1500  
EFX(005)-240x240T0800  
EFX(01)-240x240T0800  
EFX(02)-240×240  
1
0.14  
0.03  
0.03  
—  
60  
3.6  
0.05  
0.1  
0.2  
0.2  
0.3  
0.3  
0.5  
0.5  
0.07  
0.1  
0.2  
0.2  
0.3  
0.3  
0.03  
0.05  
0.1  
0.2  
0.2  
0.3  
0.3  
0.05  
0.1  
0.2  
0.2  
0.3  
0.3  
0.05  
0.1  
100  
100  
100  
100  
100  
100  
100  
100  
130  
130  
130  
130  
130  
130  
60  
6.8  
6.8  
6.8  
EFX(02)-240x240T0800  
EFX(03)-240×240  
0.03  
—  
6.8  
6.8  
EFX(03)-240x240T0800  
EFX(05)-240×240  
0.03  
—  
6.8  
6.8  
EFX(05)-240x240T1500  
EFF(007)-240x240T0800  
EFF(01)-240x240T0800  
EFF(02)-240×240  
0.14  
0.03  
0.03  
—  
6.8  
6.9  
6.9  
0.4  
6.9  
0.4  
EFF(02)-240x240T0800  
EFF(03)-240×240  
0.03  
—  
6.9  
0.4  
6.9  
0.4  
EFF(03)-240x240T0800  
EFA(003)-240x240T0800  
EFA(005)-240x240T0800  
EFA(01)-240x240T0800  
EFA(02)-240×240  
0.03  
0.03  
0.03  
0.03  
—  
6.9  
0.4  
6.8  
1.3  
60  
6.8  
1.3  
60  
6.8  
1.3  
60  
6.8  
1.3  
EFA(02)-240x240T0800  
EFA(03)-240×240  
0.03  
—  
60  
6.8  
1.3  
60  
6.8  
1.3  
EFA(03)-240x240T0800  
EFG(005)-240x240T0800  
EFG(01)-240x240T0800  
EFG(02)-240×240  
0.03  
0.03  
0.03  
—  
60  
6.8  
1.3  
20  
3.5  
0.22  
0.22  
0.22  
0.22  
0.22  
0.22  
1.3  
20  
3
3.5  
20  
3
3.5  
EFG(02)-240x240T0800  
EFG(03)-240×240  
0.03  
—  
20  
3
3.5  
20  
3
3.5  
EFG(03)-240x240T0800  
EFH(005)-240x240T2200  
EFH(01)-240x240T2200  
0.03  
0.05  
0.05  
20  
3
3.5  
60  
3.1  
3.1  
6.8  
60  
6.8  
1.3  
FS8001_EF • 3/27/2017  
3

Flex Suppressor

®  

EF Series  
Shielding  
Shielding materials  
Sꢎielꢄ  
(metal, electrically conductive material)  
ꢀeꢁleꢂꢃeꢄ  
ꢅꢆꢇes  
ꢀeꢁleꢂꢃeꢄ  
ꢅꢆꢇes  
While transmitted waves can be minimized, most of the incoming waves  
areꢀreflected,ꢀcausingꢀinternalꢀinterference.ꢀHigh-frequencyꢀelectricꢀcurrentꢀ  
occursꢀonꢀtheꢀmetalꢀsurfacesꢀandꢀreflectedꢀnoiseꢀoccursꢀatꢀtheꢀshieldingꢀ  
joints, metal openings, and other parts when the grounding is poor.  
ꢈꢉꢂoꢊiꢉꢋ ꢅꢆꢇes  
ꢌeꢃꢆl  
surꢁꢆꢂe  
ꢍiꢋꢎꢏꢁreꢐueꢉꢂꢑ  
eleꢂꢃriꢂ ꢂurreꢉꢃ  
Shielding material + radio wave absorber  
rꢆꢄio ꢅꢆꢇe  
ꢆꢒsorꢒer  
Sꢎielꢄ  
ꢍeꢆꢃ  
ꢀeꢁleꢂꢃeꢄ  
ꢅꢆꢇes  
Shieldingꢀmaterialꢀ+ꢀRadioꢀwaveꢀabsorberꢀtransmittedꢀwavesꢀandꢀreflectedꢀ  
waves can be minimized by mounting metal plates on the back of radio wave  
absorbers.  
ꢂoꢉꢇersioꢉ  
ꢀeꢁleꢂꢃeꢄ  
ꢅꢆꢇes  
ꢓrꢆꢉsꢊiꢃꢃeꢄ  
ꢅꢆꢇes  
ꢈꢉꢂoꢊiꢉꢋ  
ꢅꢆꢇes  
ꢍeꢆꢃ  
ꢂoꢉꢇersioꢉ  
rꢆꢄio ꢅꢆꢇe ꢆꢒsorꢒer  
Radio wave absorbers  
ꢈꢉꢂoꢊiꢉꢋ ꢅꢆꢇes  
Toꢀpreventꢀreflection,ꢀelectromagneticꢀenergyꢀisꢀabsorbedꢀandꢀconvertedꢀintoꢀ  
ꢍeꢆꢃ  
ꢂoꢉꢇersioꢉ  
heat.  
ꢓrꢆꢉsꢊiꢃꢃeꢄ  
ꢅꢆꢇes  
Reference: Other absorbing and reflecting examples  
Absorbing  
Radio waves absorbers  
Black objects  
Reflecting  
Metals  
Radio Waves  
Light  
White objects, Mirrors  
Solid bodies (Concrete, etc.)  
Sound  
Absorbers, Felt  
FS8001_EF • 3/27/2017  
4

Flex Suppressor

®  

EF Series  
Applications  
Case 1
ꢀ–ꢀToꢀsuppressꢀnoiseꢀreflectedꢀbyꢀcasing  
Case 2
– To suppress cross talk between substrates  
ꢀpplꢁ ꢂireꢃꢄlꢁ ꢄo ꢃꢅsiꢆꢇ  
ꢈꢉꢅse ꢊꢋ  
ꢀpplꢁ ꢌeꢄꢍeeꢆ ꢌoꢅrꢂs ꢈꢉꢅse ꢎꢋ  
Case 3
– To suppress radiation noises from LSI and IC  
ꢀpplꢁ ꢂireꢃꢄlꢁ ꢄo  
ꢄop oꢅ ꢆSꢇ or ꢇꢈ  
ꢉꢈꢊse ꢋꢌ  
ꢀpplꢁ ꢂireꢃꢄlꢁ ꢄo  
ꢃirꢃuiꢄ ꢍoꢊrꢂ liꢎe  
ꢉꢈꢊse ꢋꢌ  
ꢇꢎsulꢊꢄioꢎ proꢃess sꢏoulꢂ ꢍe perꢅorꢐeꢂ ꢑꢏeꢎ  
ꢄꢏere is ꢃoꢎꢄꢊꢃꢄ ꢄo ꢃoꢎꢂuꢃꢄiꢒe ꢐꢊꢄeriꢊl  
Case 4
– To suppress noise from cables  
ꢀrꢁp Flex Suppressor

®

ꢁrouꢂꢃ ꢄꢁꢅleꢆ  
ꢀꢁꢂꢃꢄꢅ
ꢆ
ꢇ
ꢈ
ꢂꢉꢃ ꢊꢋ ꢌꢅꢍꢋꢎꢋꢏ ꢐꢄꢃꢑ ꢑꢋꢁꢃ ꢉꢑꢎꢄꢆꢒ  
ꢓꢁꢃꢋꢎꢄꢁ
ꢔ
ꢕ
ꢀꢁꢉꢋ ꢖꢗ  
ꢇpplꢈ ꢃireꢄꢉlꢈ ꢉo ꢊlꢁꢉ ꢄꢁꢅle
ꢆ
ꢋ
ꢌꢁse ꢍꢎ  
Case 5
ꢀ–ꢀToꢀsuppressꢀnoiseꢀradiationꢀ(reflectedꢀnoise)ꢀfromꢀ  
the opening of shield, casing, etc.  
Sꢄielꢅeꢅ ꢃꢂsiꢆꢇ  
ꢀꢁꢁꢂꢃꢄeꢅ ꢂrouꢆꢅ opeꢆiꢆꢇ  
ꢈꢉꢂse ꢊꢋ  
ꢌpeꢆiꢆꢇ  
Suppressiꢆꢇ rꢂꢅiꢂꢁioꢆ  
ꢍiꢇꢄꢎꢏreꢐueꢆꢃꢑ ꢃurreꢆꢁ oꢆ sꢄielꢅeꢅ surꢏꢂꢃe  
FS8001_EF • 3/27/2017  
5

Flex Suppressor

®  

EF Series  
Applications cont’d  
Internal  
Interference  
Suppression  
RFID Transmission  
Quality  
Noise Radiation  
Suppression  
Anti-ESD  
Measure  
Anti-SAR  
Measure  
Devices  
Improvement  
On FPC and LSI for LCD  
module and camera  
module  
On main CPU – reception  
improvement  
On FPC and LSI of LCD  
module and camera  
module  
On metal parts such as  
chassis  
On loop antenna –  
Communication distance  
improvement  
Near antenna  
Around touch  
panel  
Mobile Phone  
On main CPU  
On CCD module FPD,  
image processing  
LSI, and Memory slot  
On CPU and GPU  
On cables inside LCD  
panel  
On I/O e.g. PCMCA  
and memory slot  
On LSI and FPC near  
optical pickup  
On the board and FPC  
On metal parts such as  
chassis  
Digital Camera  
Notebook PC  
On the board  
—
—
—
On loop antenna and metal  
parts near antenna –  
Communication distance  
improvement  
On CPU and GPU  
On metal parts such as  
chassis  
On wireless LAN module  
On the board and on FPC  
On metal parts such as  
chassis  
DVD/BD  
—
—
—
—
On MPEG chip  
On GPS receiver and TV  
tuner  
On LSI for LCD – Radio  
reception improvement  
On metal parts such as  
chassis  
Car Audio & Visual  
OnꢀLSI,ꢀflexibleꢀboardꢀ  
On loop antenna, and  
metal parts near antenna  
– Communication  
RFID/RW  
—
—
—
—
distance improvement  
On the interior of the  
chassis and on LSI – error  
rate improvement  
On Cable and co-axial  
cable – Reception  
Optical Reception  
Module  
—
—
—
—
—
—
—
—
Wireless LAN  
improvement  
On scanner head  
board and FPC  
Scanner  
HDD  
—
—
—
—
—
—
—
—
On I/F cable  
Mꢀꢁiꢂe phꢀꢃe  
ꢄꢀꢅeꢁꢀꢀꢆ ꢇꢈ  
ꢉigiꢅaꢂ ꢊꢅiꢂꢂ ꢋaꢌera  
ꢊoise rꢆꢋiꢆꢂioꢁ  
suppressioꢁ  
ꢀꢁꢂiꢃESꢌ  
ꢅeꢆsure  
ꢇꢁꢂerꢁꢆl  
ꢇꢁꢂerꢁꢆl  
iꢁꢂerꢈereꢁꢉe  
suppressioꢁ  
ꢀꢁꢂiꢃSꢀꢄ ꢅeꢆsure  
ꢀꢁꢂiꢃESꢌ ꢅeꢆsure  
iꢁꢂerꢈereꢁꢉe  
suppressioꢁ  
ꢇꢁꢂerꢁꢆl  
iꢁꢂerꢈereꢁꢉe  
suppressioꢁ  
ꢊoise rꢆꢋiꢆꢂioꢁ  
suppressioꢁ  
ꢀꢁꢂiꢃESꢌ  
ꢅeꢆsure  
ꢊoise rꢆꢋiꢆꢂioꢁ  
suppressioꢁ  
ꢄFꢇꢌ ꢂrꢆꢁsꢅissioꢁ  
ꢍuꢆliꢂꢎ iꢅproꢏeꢅeꢁꢂ  
ꢈar ꢃavigaꢅiꢀꢃ ꢊꢏꢊꢅeꢌ  
ꢇꢁꢂerꢁꢆl  
ꢉꢍꢉ reꢋꢀrꢎer  
iꢁꢂerꢈereꢁꢉe  
suppressioꢁ  
ꢀꢁꢂiꢃESꢌ ꢅeꢆsure  
ꢊoise rꢆꢋiꢆꢂioꢁ suppressioꢁ  
ꢇꢁꢂerꢁꢆl iꢁꢂerꢈereꢁꢉe suppressioꢁ  
ꢀꢁꢂiꢃESꢌ ꢅeꢆsure  
ꢊoise rꢆꢋiꢆꢂioꢁ suppressioꢁ  
FS8001_EF • 3/27/2017  
6

Flex Suppressor

®  

EF Series  
Examples of Shapes  
Can be cut in a variety of shapes and sizes.  
Permeable Characteristics  
140  
120  
100  
80  
/ EFH  
60  
40  
20  
/ EFH  
0
FS8001_EF • 3/27/2017  
7

Flex Suppressor

®  

EF Series  
Electrical Characteristics  
EFR – Attenuation of coupling noise  
EFR – Attenuation of transmission noise  
EFX – Attenuation of transmission noise  
EFX – Attenuation of coupling noise  
EFF – Attenuation of transmission noise  
EFF – Attenuation of coupling noise  
Above data are not guaranteed values.  
FS8001_EF • 3/27/2017  
8

Flex Suppressor

®  

EF Series  
Electrical Characteristics cont’d  
EFA – Attenuation of coupling noise  
EFA – Attenuation of transmission noise  
EFH – Attenuation of transmission noise  
EFH – Attenuation of coupling noise  
EFH  
EFH  
EFH  
EFH  
Above data are not guaranteed values.  
Measuring Method of Electrical Characteristics  
Attenuation of transmission noise  
Attenuation of coupling noise  
FS8001_EF • 3/27/2017  
9

Flex Suppressor

®  

EF Series  
Transmission Noise Attenuation Characteristics  
Shown in graphs below are values of transmission loss calculated from the transmission characteristics S11 and S21  
measured on  
Z

0

ꢀ=ꢀ50ΩꢀtypeꢀMSLꢀ(MicroꢀStripꢀLine)ꢀwithꢀaꢀFlexꢀSuppressor

®

attached.  
EFR Tꢀpe  
EFꢁ Tꢀpe  
EFF Tꢀpe  
E
F
ꢂ Tꢀpe  
EFꢃ Tꢀpe  
EFH Tꢀpe  
EFH (00ꢄ)  
EFH (01)  
Above data are not guaranteed values.  
Measuring Method of Transmission Noise Attenuation Characteristics  
Printed board (FR-4)  
100mm x 100mm x 1
.
6
mm  
Sample 50mm x 50mm  
Incident wave  
Reflection S11  
Transmission S21  
FS8001_EF • 3/27/2017
 
10  

Flex Suppressor

®  

EF Series  
Soldering Process  
Reꢀꢁꢂw ꢃrꢂꢀiꢁe  
ꢀꢁꢂ  
ꢀꢂꢂ  
ꢃꢄꢂ  
ꢌ
ꢋ
ꢅreꢆeꢇꢈiꢉꢊ  
ꢎiꢏe ꢐseꢔoꢉꢕsꢓ  
Peak Temperature  
+260°C  
Preheating  
150 – 180°C 90 seconds maximum  
200°C or more, 60 seconds  
maximum  
A
230°C or more, 40 seconds  
maximum  
B
Number of Times  
2 times maximum  
Handling Precautions  
Avoid high-temperature, humidity and direct sunlight. Storage environment should be below 40°C and below 70% relative  
humidity.  
The surface resistance value listed in this catalog is a reference value of the circuit parameter to indicate noise  
suppression. The value does not mean the product’s insulation characteristics. The value may become lower if an excess  
pressure is applied to the product.  
Products in this catalog are not insulators. Please handle them as conductors. When in actual use, please be careful so that  
conductive material does not contact the surface or the edge of the Flex Suppressor

®

sheet. Insulation process should be  
performed when contact to conductive material is probable.  
Depending upon the processing procedure, powdery substance may drop out from sheet surface or edge if cutting of the  
sheet is performed by the customer. Please be careful as this powder may effect the component’s performance depending  
on the location.  
Clean away any dust, oil or moisture from the surface of the installing area when attaching the sheet using adhesive tape.  
FS8001_EF • 3/27/2017
 
11  

Flex Suppressor

®  

EF Series  
Information on environmentally influential substances  
The Flex Suppressor

®

does not contain substances listed below:  
(1) Ozone depleting substance  
ꢀꢀꢀꢀꢀꢀꢀCFCꢀ(chlorofluorocarbon)  
Halon  
Carbon tetrachloride  
1,1,1-Trichloroethane  
ꢀꢀꢀꢀꢀꢀꢀHCFCꢀ(hydrochlorofluorocarbon)  
ꢀꢀꢀꢀꢀꢀꢀHBFCꢀ(hydrobromfluorcarbon)  
Methyl bromide  
(2) Substances regulated by RoHS order  
Lead and lead compound  
Mercury and mercury compound  
Cadmium and cadmium compound (content of plastics are below 5ppm)  
Hexavalent chromium and hexavalent chromium compound  
PBB (polybrominated biphenyl) and its kind  
PBDE (polybrominated diphenylether)  
(3) Other environmentally influential substances (examples)  
PCB (polychlorinated biphenyl)  
Polychlorinated naphthalene  
Hexachlorobenzene  
Organotin compounds (tributyl tin, triphenyl tin)  
Asbestos  
Azo compound  
ꢀꢀꢀꢀꢀꢀꢀChlorinatedꢀparaffinꢀandꢀitsꢀkindꢀ(paraffinꢀchloride,ꢀChlorinatedꢀparaffinꢀandꢀchloroparaffin)  
Radioactive substance  
PVC  
FS8001_EF • 3/27/2017
 
12  

Flex Suppressor

®  

EF Series  
KEMET Electronic Corporation Sales Offices  
Disclaimer  
Allꢀproductꢀspeci ꢀcations,ꢀstatements,ꢀinformationꢀandꢀdataꢀ(collectively,ꢀtheꢀ“Information”)ꢀinꢀthisꢀdatasheetꢀareꢀsubjectꢀtoꢀchange.ꢀTheꢀcustomerꢀisꢀresponsibleꢀforꢀ  
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.  
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.  
StatementsꢀofꢀsuitabilityꢀforꢀcertainꢀapplicationsꢀareꢀbasedꢀonꢀKEMETꢀElectronicsꢀCorporation’sꢀ(“KEMET”)ꢀknowledgeꢀofꢀtypicalꢀoperatingꢀconditionsꢀforꢀsuchꢀ  
applications,ꢀbutꢀareꢀnotꢀintendedꢀtoꢀconstituteꢀ–ꢀandꢀKEMETꢀspeci ꢀcallyꢀdisclaimsꢀ–ꢀanyꢀwarrantyꢀconcerningꢀsuitabilityꢀforꢀaꢀspeci ꢀcꢀcustomerꢀapplicationꢀorꢀuse.ꢀ  
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any  
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no  
obligation or liability for the advice given or results obtained.  
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component  
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards  
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or  
property damage.  
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other  
measures may not be required.  
KEMET is a registered trademark of KEMET Electronics Corporation.  
FS8001_EF • 3/27/2017
 
13