Littelfuse-ALT115-S

Part #Littelfuse-ALT115-S
Download 
Littelfuse-ALT115-S
Protection Relays  
Alternating Relays  
ALT SERIES  
8-pin Plug-in Alternating Relay  
Description  
The ALT series alternating relays are used to alternate between  
two loads. The A
L
T
i
s commonly used in duplex pumping  
applications to balance the runtime of both pumps.  
The
A
L
T
–
S
is used in single high-level float applications. When  
the float switch opens, the alternating relay changes state,  
forcing the other pump to run the next time the float closes.  
All A
L
T
r
elays have a built-in debounce feature that prevents  
the relay from changing state if the switch or float contact  
bounces momentarily.  
The
A
L
T
–
X
has an internal cross-connected relay and is used  
in dual high-level float applications. These floats are commonly  
referred to as lead and lag floats.  
Wiring Diagram  
The pumps alternate as in the A
L
T
–
S version but the cross-  
connected relay configuration allows both pumps to run  
simultaneously when both the lead and lag floats are closed.  
TYPICAL WIRING DIAGRAM FO
R
T
HE A
L
T
–
S  
These relays are also available with a built-in switch (SW option)  
that is used to manually force one of the pumps to run every  
time the float switch is closed. This is helpful when a pump has  
been removed for repair or for test purposes. In the case of the  
A
L
T
–
X-SW,
the switch essentially forces one pump to be the  
lead pump, while still allowing the second to run when both  
floats are closed.  
Must use the OT08PC socket for UL Rating!  
*Note: Manufacturer’s recommended screw terminal torque for the OT series  
Octal Sockets is 12 in.-lbs.  
TYPICAL WIRING DIAGRAM FOR THE A
L
T
–
X (CROSS CONNECTED)  
ALTERNATING RELAY  
S1  
F1  
Features & Benefits  
L1  
L2  
2
7
3
6
1
8
4
5
FEATURES  
BENEFITS  
F2  
S2  
Prevents nuisance actuating causes by waves or  
spashing in the tank  
F1 – F2:  
Debounce time delay  
1-2A TYPICAL SIZE  
FOR CONTACTOR COILS  
Built-in manual/  
auto switch  
Force lead pump operation when a pump is  
removed for repair or testing (on select models)  
F3  
F4  
L1  
L2  
PUMP  
#1  
Ordering Information  
F3 – F6:  
SIZE FOR INDIVIDUAL  
PUMP APPLICATION  
F5  
MODEL  
ALT024-S

†  

LINE VOLTAGE  
DESCRIPTION  
MAGNETIC CONTACTORS  
20-26 V ac or V dc  
For single high-level float applications  
For single high-level float applications  
with built in manual switch  
L1  
L2  
ALT024-S-SW

†  

ALT115-S  
20-26 V ac or V dc  
95-125 V ac  
PUMP  
#2  
F6  
For single high-level float applications  
For single high-level float applications  
with built in manual switch  
95-125 V ac  
ALT115-S-SW  
For dual high-level (lead and lag) float  
applications  
For dual high-level (lead and lag) float  
applications with built in manual switch  
For single high-level float applications  
For single high-level float applications  
with built in manual switch  
95-125 V ac  
ALT115-X  
Accessories  
OT08PC Octal 8-pin Socket  
95-125 V ac  
195-250 V ac  
195-250 V ac  
ALT115-X-SW  
ALT230-S  
8-pin 35 mm DIN rail or surface mount. Rated at  
10 A @ 600 V ac. Surface mounted with two #6  
screws or snaps onto a 35 mm DIN rail.  
ALT230-S-SW  
For dual high-level (lead and lag) float  
applications  
For dual high-level (lead and lag) float  
applications with built in manual switch  
195-250 V ac  
195-250 V ac  
ALT230-X  
ALT230-X-SW  

†

ALT024-S and ALT024-S-SW are not UL Listed  
© 2019 Littelfuse, Inc.  
Rev: 2-C-043019  

Protection Relays  
Alternating Relays  
ALT SERIES  
General Characteristics  
Temperature Range  
Maximum Input Power  
Safety Marks  
UL (OT08PC octal  
socket required)  
CSA  
Specifications  
-40 °C to 50 °C (-40 °F to 122 °F)  
5 W  
Input Characteristics  
Supply Current  
40 mA  
Functional Characteristics  
Debounce Time Delay  
Control Input Impedance (min)  
24  
115  
230  
0.5 second  
UL 508 (File #E68520)  
C22.2 No. 14 (File #46510)  
H
44.45 mm (1.75”);
W
60.33 mm (2.375”);  
D
104.78 mm (4.125”)  
0.38 lb. (6.08 oz., 172.67 g)  
DIN rail or surface mount  
(plug into OT08PC socket)  
OT08PC (UL Rating 600 V)  
10 kΩ  
56 kΩ  
100 kΩ  
Dimensions (with socket)  
Weight  
Mounting Method  
Output Characteristics  
Output Contact Rating  
480 VA @ 240 V ac  
Socket Available  
The 600 V socket can be surface mounted or installed on DIN rail.  
Disclaimer Notice –
Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own  
applications. Littelfuse products are not designed for, and may not be used in, all applications. Read complete Disclaimer Notice at

© 2019 Littelfuse, Inc.  
Rev: 2-C-043019