MA-COM-MACP-010572-TR1000
| Part # | MA-COM-MACP-010572-TR1000 |
| Download | MA-COM-MACP-010572-TR1000 |
MACP-010572
Temperature Compensated Directional
Power Detector
6 – 18 GHz
Rev. V2
Features
Functional Schematic
Integrated Directional Coupler
Low Insertion Loss: 0.27 dB @ 12 GHz
Minimum Detectable Power: -16 dBm @ 12 GHz
Built-In Temperature Compensation
Lead-Free 1.5 x 1.2 mm 6-Lead TDFN Plastic
Package
Halogen-
Free “Green” Mold Compound
RoHS* Compliant and 260°C Reflow Compatible
Description
The MACP-010572 belongs to a series of small,
easy-to-use, broadband, directional detectors. With
integrated low loss directional couplers and built-in
temperature compensation circuits, these detectors
provide an easy way to monitor the power of a signal
travelling in a specific direction along a transmission
line. Detectors are housed in a miniature, surface
mount, lead less plastic package. They require a
small amount of bias for proper performance. The
total bias current is less than 0.5 mA.
Pin Configuration
3
Pin #
Pin Name
Description
1
2
3
4
5
6
7
RF
OUT
N/C
RF Output
No Connection
3
RF Input
Typical applications include power monitoring and
leveling in Point-to-Point radios, IMS, Radar, VSAT,
EW, and Aerospace & Defense systems.
RF
IN
V
BIAS
N/C
Bias Voltage
No Connection
3
Detector Voltage
Ground
The surface mount package is small yet can be
handled and placed with standard pick and place
assembly equipment. Detectors are fabricated on a
well established GaAs process featuring full
passivation for performance and reliability.
V
DET
GND
3. Pins
2 and 5 are not connected internally and should not be
used for grounding. Package has exposed bottom metal
paddle (Pin 7) which should be connected to the circuit
ground. The parasitic inductance introduced by this connection
should be as small as possible.
Ordering Information
1,2
Part #
Package
MACP-010572-TR1000
MACP-010572-001SMB
1000 part reel
Sample Board
1. Reference
Application Note M513 for reel size information.
2. All
sample boards include 5 loose parts.
* Restrictions on Hazardous Substances, European Union Directive 2011/65/EU.
1
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0017867
MACP-010572
Temperature Compensated Directional
Power Detector
6 – 18 GHz
Rev. V2
Electrical Specifications:
Freq. = 12 GHz, T
A
= 25°C, V
B
= +3.2 V, Z
0
= 50
Ω (
unless otherwise specified)
Parameter
Test Conditions
Units
Min.
Typ.
Max.
6 GHz
12 GHz
18 GHz
0.15
0.27
0.67
Insertion Loss
dB
—
—
10 dBm applied to Input
6 GHz
190
360
550
Detect Voltage
Directivity
mV
dB
—
—
—
—
—
—
12 GHz
18 GHz
Into 50
Ω
load
6 GHz
21
16
12
12 GHz
18 GHz
Minimum recommended power level
6 GHz
12 GHz
18 GHz
-10
-16
-21
Sensitivity
dBm
Maximum recommended power level
6 – 18 GHz
Maximum Power
Input Return Loss
dBm
dB
—
—
30
—
—
6 GHz
12 GHz
18 GHz
23
30
13
6 GHz
12 GHz
18 GHz
22
31
14
Output Return Loss
dB
—
—
DC Offset
Detect voltage with no RF input power
V Bias = 3.2 V
mV
mA
50
100
0.3
150
Bias Current
—
0.35
Absolute Maximum Ratings
4,5
Handling Procedures
Please observe the following precautions to avoid
damage:
Parameter
Absolute Maximum
Input Power
+40 dBm
8 V
Static Sensitivity
Operating Voltage
Operating Temperature
Storage Temperature
Gallium Arsenide Integrated Circuits are sensitive to
electrostatic discharge (ESD) and can be damaged
by static electricity.
Proper ESD control techniques
should be used when handling these HBM Class 0A
devices.
–
40°C to +85°C
–
65°C to +150°C
4. Exceeding
any one or combination of these limits may cause
permanent damage to this device.
5. MACOM
does not recommend sustained operation near these
survivability limits.
2
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0017867
MACP-010572
Temperature Compensated Directional
Power Detector
6 – 18 GHz
Rev. V2
Application Information
The MACP-010572 is designed to deliver high
performance and to be easy to use.
Recommended PCB Configuration
No external components are needed. The RF
connections required by the MACP-010572 are
shown in a schematic below.
Pin 3 should be connected to the RF line bringing
the input signal. Pin 1 is the RF output. The third
required connection is that to the RF ground. The
exposed metal paddle on the back of the package
must be connected to the RF ground of the board
housing the detector. This can be accomplished by
using conductive via holes. It is important to ensure
that the parasitic inductance associated with the
connection between the detector and the RF ground
is as small as possible. The RF ground also provides
the return path for the DC bias current.
MACP-010572
Evaluation Board
MACOM will supply an evaluation board and loose
samples upon qualified request. The kit consists of a
PCB and SMA connectors. MACOM suggests a
Rogers 4350 dielectric of 0.008” (0.20 mm) with ½
ounce copper. Proper grounding is always
important, we suggest 8 mil (0.20 mm) vias placed
generously underneath the part.
RF
IN
(Pin 3)
RF
OUT
(Pin 1)
DC Bias
The MACP-010572 operates with a positive 3.2 V
bias applied to pin 4. The output voltage is available
on pin 6.
3
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0017867
MACP-010572
Temperature Compensated Directional
Power Detector
6 – 18 GHz
Rev. V2
Typical Performance Curves:
Insertion Loss
Detect Voltage vs. Input Power
0.0
1.0
+25°C
-40°C
+85°C
6 GHz
12 GHz
18 GHz
0.8
0.6
0.4
0.2
0.0
-0.2
-0.4
-0.6
-0.8
0
-5
0
5
10
15
20
5
10
15
20
Input Power (dBm)
Frequency (GHz)
Output Return Loss
Input Return Loss
0
0
+25°C
-40°C
+85°C
+25°C
-40°C
+85°C
-10
-10
-20
-30
-40
-20
-30
-40
-50
-50
0
5
10
15
20
0
5
10
15
20
Frequency (GHz)
Frequency (GHz)
Temperature Compensation Accuracy
Directivity
25
30
6 GHz
12 GHz
18 GHz
20
15
10
20
10
0
+25°C
-40°C
+85°C
5
0
-10
0
5
10
15
20
-5
0
5
10
15
20
Frequency (GHz)
Input Power (dBm)
4
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0017867
MACP-010572
Temperature Compensated Directional
Power Detector
6 – 18 GHz
Rev. V2
Lead-Free 1.5 x 1.2
mm 6-Lead
†
Reference Application Note S2083 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements
Plating is NiPdAuAg.
5
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0017867
MACP-010572
Temperature Compensated Directional
Power Detector
6 – 18 GHz
Rev. V2
MACOM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with MACOM Technology Solutions Inc (“MACOM”)
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM’s Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.
6
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0017867