MA-COM-MACP-010572-TR1000

Part #MA-COM-MACP-010572-TR1000
Download 
MA-COM-MACP-010572-TR1000
MACP-010572  
Temperature Compensated Directional
 
Power Detector  
6 – 18 GHz  
Rev. V2  
Features  
Functional Schematic  
Integrated Directional Coupler  
Low Insertion Loss: 0.27 dB @ 12 GHz  
Minimum Detectable Power: -16 dBm @ 12 GHz  
Built-In Temperature Compensation  
Lead-Free 1.5 x 1.2 mm 6-Lead TDFN Plastic  
Package  
Halogen-
Free “Green” Mold Compound  
RoHS* Compliant and 260°C Reflow Compatible  
Description  
The MACP-010572 belongs to a series of small,  
easy-to-use, broadband, directional detectors. With  
integrated low loss directional couplers and built-in  
temperature compensation circuits, these detectors  
provide an easy way to monitor the power of a signal  
travelling in a specific direction along a transmission  
line. Detectors are housed in a miniature, surface  
mount, lead less plastic package. They require a  
small amount of bias for proper performance. The  
total bias current is less than 0.5 mA.  
Pin Configuration

3  

Pin #  
Pin Name  
Description  
1
2
3
4
5
6
7
RF

OUT  

N/C  
RF Output  
No Connection

3  

RF Input  
Typical applications include power monitoring and  
leveling in Point-to-Point radios, IMS, Radar, VSAT,  
EW, and Aerospace & Defense systems.  
RF

IN  

V

BIAS  

N/C  
Bias Voltage  
No Connection

3  

Detector Voltage  
Ground  
The surface mount package is small yet can be  
handled and placed with standard pick and place  
assembly equipment. Detectors are fabricated on a  
well established GaAs process featuring full  
passivation for performance and reliability.  
V

DET  

GND  
3. Pins
 
2 and 5 are not connected internally and should not be  
used for grounding. Package has exposed bottom metal  
paddle (Pin 7) which should be connected to the circuit  
ground. The parasitic inductance introduced by this connection  
should be as small as possible.  
Ordering Information

1,2  

Part #  
Package  
MACP-010572-TR1000  
MACP-010572-001SMB  
1000 part reel  
Sample Board  
1. Reference
 
Application Note M513 for reel size information.  
2. All
 
sample boards include 5 loose parts.  
* Restrictions on Hazardous Substances, European Union Directive 2011/65/EU.  
1
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.  
Visit

for additional data sheets and product information.  
For further information and support please visit:  
DC-0017867  

MACP-010572  
Temperature Compensated Directional
 
Power Detector  
6 – 18 GHz  
Rev. V2  
Electrical Specifications:  
Freq. = 12 GHz, T

A

= 25°C, V

B

= +3.2 V, Z

0

= 50
Ω (
unless otherwise specified)  
Parameter  
Test Conditions  
Units  
Min.  
Typ.  
Max.  
6 GHz  
12 GHz  
18 GHz  
0.15  
0.27  
0.67  
Insertion Loss  
dB  
—
—
10 dBm applied to Input  
6 GHz  
190  
360  
550  
Detect Voltage  
Directivity  
mV  
dB  
—
—
—
—
—
—
12 GHz  
18 GHz  
Into 50
Ω
load  
6 GHz  
21  
16  
12  
12 GHz  
18 GHz  
Minimum recommended power level  
6 GHz  
12 GHz  
18 GHz  
-10  
-16  
-21  
Sensitivity  
dBm  
Maximum recommended power level  
6 – 18 GHz  
Maximum Power  
Input Return Loss  
dBm  
dB  
—
—
30  
—
—
6 GHz  
12 GHz  
18 GHz  
23  
30  
13  
6 GHz  
12 GHz  
18 GHz  
22  
31  
14  
Output Return Loss  
dB  
—
—
DC Offset  
Detect voltage with no RF input power  
V Bias = 3.2 V  
mV  
mA  
50  
100  
0.3  
150  
Bias Current  
—
0.35  
Absolute Maximum Ratings

4,5  

Handling Procedures  
Please observe the following precautions to avoid  
damage:  
Parameter  
Absolute Maximum  
Input Power  
+40 dBm  
8 V  
Static Sensitivity  
Operating Voltage  
Operating Temperature  
Storage Temperature  
Gallium Arsenide Integrated Circuits are sensitive to  
electrostatic discharge (ESD) and can be damaged  
by static electricity.
 
Proper ESD control techniques  
should be used when handling these HBM Class 0A  
devices.  
–
40°C to +85°C  
–
65°C to +150°C  
4. Exceeding
 
any one or combination of these limits may cause  
permanent damage to this device.  
5. MACOM
 
does not recommend sustained operation near these  
survivability limits.  
2
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.  
Visit

for additional data sheets and product information.  
For further information and support please visit:  
DC-0017867  

MACP-010572  
Temperature Compensated Directional
 
Power Detector  
6 – 18 GHz  
Rev. V2  
Application Information  
The MACP-010572 is designed to deliver high  
performance and to be easy to use.  
Recommended PCB Configuration  
No external components are needed. The RF  
connections required by the MACP-010572 are  
shown in a schematic below.  
Pin 3 should be connected to the RF line bringing  
the input signal. Pin 1 is the RF output. The third  
required connection is that to the RF ground. The  
exposed metal paddle on the back of the package  
must be connected to the RF ground of the board  
housing the detector. This can be accomplished by  
using conductive via holes. It is important to ensure  
that the parasitic inductance associated with the  
connection between the detector and the RF ground  
is as small as possible. The RF ground also provides  
the return path for the DC bias current.  
MACP-010572  
Evaluation Board  
MACOM will supply an evaluation board and loose  
samples upon qualified request. The kit consists of a  
PCB and SMA connectors. MACOM suggests a  
Rogers 4350 dielectric of 0.008” (0.20 mm) with ½  
ounce copper. Proper grounding is always  
important, we suggest 8 mil (0.20 mm) vias placed  
generously underneath the part.  
RF
IN  
(Pin 3)  
RF
OUT  
(Pin 1)  
DC Bias  
The MACP-010572 operates with a positive 3.2 V  
bias applied to pin 4. The output voltage is available  
on pin 6.  
3
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.  
Visit

for additional data sheets and product information.  
For further information and support please visit:  
DC-0017867  

MACP-010572  
Temperature Compensated Directional
 
Power Detector  
6 – 18 GHz  
Rev. V2  
Typical Performance Curves:  
Insertion Loss  
Detect Voltage vs. Input Power  
0.0  
1.0  
+25°C  
-40°C  
+85°C  
6 GHz  
12 GHz  
18 GHz  
0.8  
0.6  
0.4  
0.2  
0.0  
-0.2  
-0.4  
-0.6  
-0.8  
0
-5  
0
5
10  
15  
20  
5
10  
15  
20  
Input Power (dBm)  
Frequency (GHz)  
Output Return Loss  
Input Return Loss  
0
0
+25°C  
-40°C  
+85°C  
+25°C  
-40°C  
+85°C  
-10  
-10  
-20  
-30  
-40  
-20  
-30  
-40  
-50  
-50  
0
5
10  
15  
20  
0
5
10  
15  
20  
Frequency (GHz)  
Frequency (GHz)  
Temperature Compensation Accuracy  
Directivity  
25  
30  
6 GHz  
12 GHz  
18 GHz  
20  
15  
10  
20  
10  
0
+25°C  
-40°C  
+85°C  
5
0
-10  
0
5
10  
15  
20  
-5  
0
5
10  
15  
20  
Frequency (GHz)  
Input Power (dBm)  
4
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.  
Visit

for additional data sheets and product information.  
For further information and support please visit:  
DC-0017867  

MACP-010572  
Temperature Compensated Directional
 
Power Detector  
6 – 18 GHz  
Rev. V2  
Lead-Free 1.5 x 1.2
mm 6-Lead  
†
Reference Application Note S2083 for lead-free solder reflow recommendations.  
Meets JEDEC moisture sensitivity level 1 requirements  
Plating is NiPdAuAg.  
5
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.  
Visit

for additional data sheets and product information.  
For further information and support please visit:  
DC-0017867  

MACP-010572  
Temperature Compensated Directional
 
Power Detector  
6 – 18 GHz  
Rev. V2  
MACOM Technology Solutions Inc. All rights reserved.  
Information in this document is provided in connection with MACOM Technology Solutions Inc (“MACOM”)  
products. These materials are provided by MACOM as a service to its customers and may be used for  
informational purposes only. Except as provided in MACOM’s Terms and Conditions of Sale for such products or  
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM  
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to  
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update  
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future  
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,  
to any intellectual property rights is granted by this document.  
THESE MATERIALS ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR  
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR  
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR  
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR  
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY  
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN  
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR  
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,  
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.  
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM  
customers using or selling MACOM products for use in such applications do so at their own risk and agree to  
fully indemnify MACOM for any damages resulting from such improper use or sale.  
6
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.  
Visit

for additional data sheets and product information.  
For further information and support please visit:  
DC-0017867