MA-COM-MADT-011000-TR1000
| Part # | MA-COM-MADT-011000-TR1000 |
| Download | MA-COM-MADT-011000-TR1000 |
MADT-011000
Power Detector
5 – 44 GHz
Rev. V1
Features
Functional Schematic
Input Power: -15 to +15 dBm
Dynamic Range: 30 dB
DC supply: 4.5 V, 70 µA
Lead-Free 3 mm 16-Lead QFN Package
ESD protected
GND
16
GND GND GND
15 14 13
GND
GND
RF
IN
GND
12 GND
1
2
3
4
RoHS* Compliant
Matching & Bias
GND
GND
GND
Description
11
10
9
MADT-011000 is a single-ended, internally-matched
power detector with wide input bandwidth and high
dynamic range. The circuit consumes 70
μ
A from a
4.5 V supply, while matched detector and reference
diodes provide temperature compensation in
differential operation.
5
6
7
8
The power detector is housed in a 3 mm 16-lead
QFN package and is ESD protected for reliability
and ease of handling.
V
DET
V
DC
V
REF
GND
Pin Configuration
3
MADT-011000 is well suited for power control in
microwave radios, test and measurement
equipment, and radar applications.
Pin No.
Function
GND
3
RF
IN
1, 2, 4, 8 – 16
MADT-011000 is also available in bare die format.
Refer to datasheet MADT-011000-DIE.
3
5
6
7
V
DET
V
DC
Ordering Information
1,2
V
REF
Paddle
4
Part Number
MADT-011000
Package
Bulk
3. MACOM
recommends connecting unused package pins to
ground.
4. The
exposed pad centered on the package bottom must be
connected to RF, DC and thermal ground.
MADT-011000-TR1000
MADT-011000-SB1
1000 Piece Reel
Sample Board
1. Reference
Application Note M513 for reel size information.
2. All
sample boards include 5 loose parts.
* Restrictions on Hazardous Substances, European Union Directive 2011/65/EU.
1
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0012400
MADT-011000
Power Detector
5 – 44 GHz
Rev. V1
Electrical Specifications:
Freq. = 5 – 44 GHz, T
A
= +25°C, V
DC
= 4.5 V, Z
0
= 50
Ω
5
Parameter
Input Power
Test Conditions
—
Units
dBm
dB
Min.
-15
30
Typ.
—
Max.
+15
—
Dynamic Range
Vref – Vdet > 5 mV
—
Vdelta = Vref – Vdet
Vdelta
mV
5
—
2200
Input power = -15 to +15 dBm
5 – 10 GHz
10 – 12 GHz
12 – 36 GHz
36 – 44 GHz
-11
-11
-15
-18
-9
-9
Return Loss
dB
—
-9
-13
Supply Voltage
—
—
V
—
4.5
70
—
Current Consumption
µA
60
80
5. All
specifications refer to CW input signal.
Application Circuit
8,9
Absolute Maximum Ratings
6,7
Parameter
Input Power
Absolute Maximum
16
15
14
13
18 dBm
6 V
VDC
12
11
10
9
1
2
3
4
Operating Temperature
Storage Temperature
–
40°C to +85°C
–
65°C to +150°C
RF
IN
6. Exceeding
any one or combination of these limits may cause
permanent damage to this device.
7.
MACOM does not recommend sustained operation near these
survivability limits.
5
6
7
8
Handling Procedures
Please observe the following precautions to avoid
damage:
V
DC
V
DET
27 k
V
REF
27 k
Static Sensitivity
8. External
27 k
Ω
resistors are recommended for optimum
performance.
9. Typical
Vref = 0.74 V
These electronic devices are sensitive to
electrostatic discharge (ESD) and can be damaged
by static electricity.
Proper ESD control techniques
should be used when handling these Class 1B
devices.
2
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0012400
MADT-011000
Power Detector
5 – 44 GHz
Rev. V1
Typical Performance Curves: T
A
= 25°C
Vdelta vs. Input Power, 11 – 17 GHz
Vdelta vs. Input Power, 5 – 10 GHz
10
10
11 GHz
12 GHz
13 GHz
14 GHz
5 GHz
6 GHz
7 GHz
8 GHz
1
1
15 GHz
9 GHz
16 GHz
17 GHz
10 GHz
0.1
0.01
0.1
0.01
0.001
0.001
-20
-15
-10
-5
0
5
5
5
10
15
-20
-15
-10
-5
0
5
10
10
10
15
15
15
Input Power (dBm)
Input Power (dBm)
Vdelta vs. Input Power, 18 – 24 GHz
Vdelta vs. Input Power, 25 – 31 GHz
10
10
18 GHz
19 GHz
20 GHz
21 GHz
22 GHz
23 GHz
24 GHz
25 GHz
26 GHz
27 GHz
28 GHz
29 GHz
30 GHz
31 GHz
1
1
0.1
0.01
0.1
0.01
0.001
0.001
-20
-15
-10
-5
0
5
-20
-15
-10
-5
0
10
15
Input Power (dBm)
Input Power (dBm)
Vdelta vs. Input Power, 32 – 38 GHz
Vdelta vs. Input Power, 39 – 44 GHz
10
10
32 GHz
33 GHz
34 GHz
35 GHz
36 GHz
37 GHz
38 GHz
39 GHz
40 GHz
41 GHz
1
1
0.1
42 GHz
43 GHz
44 GHz
0.1
0.01
0.01
0.001
0.001
-20
-15
-10
-5
0
5
-20
-15
-10
-5
0
10
15
Input Power (dBm)
Input Power (dBm)
3
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0012400
MADT-011000
Power Detector
5 – 44 GHz
Rev. V1
Typical Performance Curves – Over Temperature
Vdelta vs. Temperature, 15 GHz
Vdelta vs. Temperature, 5 GHz
10
10
+25°C
-40°C
+85°C
+25°C
-40°C
+85°C
1
0.1
1
0.1
0.01
0.001
0.01
0.001
-20
-15
-10
-5
0
5
10
15
-20
-15
-10
-5
0
5
10
15
Input Power (dBm)
Input Power (dBm)
Vdelta vs. Temperature, 23 GHz
Vdelta vs. Temperature, 30 GHz
10
10
+25°C
-40°C
+85°C
+25°C
-40°C
+85°C
1
0.1
1
0.1
0.01
0.001
0.01
0.001
-20
-15
-10
-5
0
5
10
15
-20
-15
-10
-5
0
5
10
15
Input Power (dBm)
Input Power (dBm)
Vdelta vs. Temperature, 38 GHz
Vdelta vs. Temperature, 44 GHz
10
10
+25°C
-40°C
+85°C
+25°C
-40°C
+85°C
1
0.1
1
0.1
0.01
0.001
0.01
0.001
-20
-15
-10
-5
0
5
10
15
-20
-15
-10
-5
0
5
10
15
Input Power (dBm)
Input Power (dBm)
4
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0012400
MADT-011000
Power Detector
5 – 44 GHz
Rev. V1
Typical Performance Curves
Vdelta vs. Frequency, P
IN
= 0 dBm
Vdelta vs. Frequency, P
IN
= -15 dBm
0.400
0.030
+25°C
-40°C
+85°C
+25°C
-40°C
+85°C
0.350
0.025
0.300
0.250
0.200
0.150
0.100
0.020
0.015
0.010
0.005
0.000
5
10
15
20
25
30
35
40
45
5
10
15
20
25
30
35
40
45
Frequency (GHz)
Frequency (GHz)
Input Return Loss vs. Frequency
Vdelta vs. Frequency, P
IN
= +15 dBm
0
2.600
+25°C
-40°C
+85°C
2.400
2.200
2.000
1.800
1.600
1.400
-5
-10
-15
-20
-25
5
10
15
20
25
30
35
40
45
5
10
15
20
25
30
35
40
45
Frequency (GHz)
Frequency (GHz)
5
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0012400
MADT-011000
Power Detector
5 – 44 GHz
Rev. V1
Lead-Free 3
mm 16-Lead PQFN
†
†
Reference Application Note S2083 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
Plating is NiPdAuAg
6
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0012400
MADT-011000
Power Detector
5 – 44 GHz
Rev. V1
MACOM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with MACOM Technology Solutions Inc (“MACOM”)
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM’s Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.
7
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
DC-0012400