MA-COM-MD-189-PIN
| Part # | MA-COM-MD-189-PIN |
| Download | MA-COM-MD-189-PIN |
MD- / MDS-189
High Level Termination Insensitive Mixer,
1 – 3500 MHz
Rev. V4
Features
FP-2 (MD-189)
Operates Over Full PCN/PCS/PHS/MSS Bands
Low Conversion Loss
Fully Hermetic Package
Intermodulation Ratio Insensitive to System
Mismatches
VSWR: <2.0:1 Typical Midband
Isolation: 35 dB Typical Midband
High IIP
3
(+28 dBm Typical 1-3500 MHz)
Description
M/A-
COM’s MD
-189 and MDS-189 are high level
termination insensitive mixers.
These devices are
packaged in 8-lead flatpack and SMT packages.
These mixers offer consistent and repeatable flat
intermodulation performance and flat conversion
loss with low spurious signal generation independent
of system mismatch from 1 to 3500 MHz.
The MD
-189 and MDS-189 are ideally suited for RF/IF com-
munications applications requiring high intercept
point performance.
SF-1 (MDS-189)
Pin Configuration (MD-189)
Pin No.
Function
GND
GND
GND
IF
Pin No.
Function
1
2
3
4
5
6
7
8
LO
GND
GND
RF
Pin Configuration (MDS-189)
Pin No.
Function
GND
Pin No.
Function
LO
1
2
3
4
IF
RF
Absolute Maximum Ratings
1
Parameter
Absolute Maximum
Max Input Power
2
Total Power
0.5W Derated to 85
o
C
@ 3.2 mW/
o
C
LO Power
+27 dBm
1. Operation
of this device above any one of these parameters
nay cause permanent damage.
2. Ambient
Temperature (T
A
) = +25
o
C
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
MD- / MDS-189
High Level Termination Insensitive Mixer,
1 – 3500 MHz
Rev. V4
Electrical Specifications
1
: T
A
= –
55°C to +85°C
Frequency: RF, LO Ports = 1-3500 MHz, IF Port = 5-1500 MHz
Parameter
Test Conditions
Frequency
Units
Min
Typ
Max
Conversion Loss
LO @ 23 dBm
IF @ 60 MHz
5 – 1000 MHz
1000 – 3000 MHz
1 – 3500 MHz
dB
dB
dB
—
—
—
6.5
7.5
8.0
7.0
8.5
9.5
Isolation
LO to RF
LO to IF
RF to IF
1 – 2000 MHz
2000 – 3500 MHz
dB
dB
30
25
35
30
—
—
1 – 2000 MHz
2000 – 3500 MHz
dB
dB
25
20
30
25
—
—
10 – 500 MHz
1 – 3500 MHz
dB
dB
30
15
35
20
—
—
Input Compression
(1 dB)
LO @ 23 dBm
IF @ 60 MHz
—
—
—
—
—
+20
+28
+17
—
—
IIP
3
LO @ 23 dBm
IF @ 60 MHz
dBm
Desensitivity (1dB)
LO @ 23 dBm
IF @ 60 MHz
—
—
dBm
dBm
—
—
—
—
SSB Noise Figure
LO @ 23 dBm
IF @ 60 MHz
—
—
—
—
—
Within 1 dB of Conversion Loss
Max
Bottom View of
SF-1
Typical Performance Curves
4X .016
± .002
.506
.385 Ref
.220
.165
.381
.002
.000
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
MD- / MDS-189
High Level Termination Insensitive Mixer,
1 – 3500 MHz
Rev. V4
Typical Performance Curves
Ordering Information
Part Number
Package
MD-189 PIN
FP-2
MDS-189 PIN
SF-1
3
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit:
MD- / MDS-189
High Level Termination Insensitive Mixer,
1 – 3500 MHz
Rev. V4
M/A-COM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with M/A-COM Technology Solutions Inc (“MACOM”)
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM’s Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.
4
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
For further information and support please visit: