MA-COM-MD-189-PIN

Part #MA-COM-MD-189-PIN
Download 
MA-COM-MD-189-PIN
MD- / MDS-189  
High Level Termination Insensitive Mixer,  
1 – 3500 MHz  
Rev. V4  
Features  
FP-2 (MD-189)  
Operates Over Full PCN/PCS/PHS/MSS Bands  
Low Conversion Loss  
Fully Hermetic Package  
Intermodulation Ratio Insensitive to System  
Mismatches  
VSWR: <2.0:1 Typical Midband  
Isolation: 35 dB Typical Midband  
High IIP

3

(+28 dBm Typical 1-3500 MHz)  
Description  
M/A-
COM’s MD
-189 and MDS-189 are high level  
termination insensitive mixers.
 
These devices are  
packaged in 8-lead flatpack and SMT packages.  
These mixers offer consistent and repeatable flat  
intermodulation performance and flat conversion  
loss with low spurious signal generation independent  
of system mismatch from 1 to 3500 MHz.
 
The MD  
-189 and MDS-189 are ideally suited for RF/IF com-  
munications applications requiring high intercept  
point performance.  
SF-1 (MDS-189)  
Pin Configuration (MD-189)  
Pin No.  
Function  
GND  
GND  
GND  
IF  
Pin No.  
Function  
1
2
3
4
5
6
7
8
LO  
GND  
GND  
RF  
Pin Configuration (MDS-189)  
Pin No.  
Function  
GND  
Pin No.  
Function  
LO  
1
2
3
4
IF  
RF  
Absolute Maximum Ratings

1  

Parameter  
Absolute Maximum  
Max Input Power

2  

Total Power  
0.5W Derated to 85

o

C  
@ 3.2 mW/

o

C  
LO Power  
+27 dBm  
1. Operation
 
of this device above any one of these parameters  
nay cause permanent damage.  
2. Ambient
 
Temperature (T

A

) = +25

o

C  
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.  
Visit

for additional data sheets and product information.  
For further information and support please visit:  

MD- / MDS-189  
High Level Termination Insensitive Mixer,  
1 – 3500 MHz  
Rev. V4  
Electrical Specifications

1

: T

A

= –
55°C to +85°C  
Frequency: RF, LO Ports = 1-3500 MHz, IF Port = 5-1500 MHz  
Parameter  
Test Conditions  
Frequency  
Units  
Min  
Typ  
Max  
Conversion Loss  
LO @ 23 dBm  
IF @ 60 MHz  
5 – 1000 MHz  
1000 – 3000 MHz  
1 – 3500 MHz  
dB  
dB  
dB  
—
—
—
6.5  
7.5  
8.0  
7.0  
8.5  
9.5  
Isolation  
LO to RF  
LO to IF  
RF to IF  
1 – 2000 MHz  
2000 – 3500 MHz  
dB  
dB  
30  
25  
35  
30  
—
—
1 – 2000 MHz  
2000 – 3500 MHz  
dB  
dB  
25  
20  
30  
25  
—
—
10 – 500 MHz  
1 – 3500 MHz  
dB  
dB  
30  
15  
35  
20  
—
—
Input Compression  
(1 dB)  
LO @ 23 dBm  
IF @ 60 MHz  
—
—
—
—
—
+20  
+28  
+17  
—
—
IIP

3  

LO @ 23 dBm  
IF @ 60 MHz  
dBm  
Desensitivity (1dB)  
LO @ 23 dBm  
IF @ 60 MHz  
—
—
dBm  
dBm  
—
—
—
—
SSB Noise Figure  
LO @ 23 dBm  
IF @ 60 MHz  
—
—
—
—
—
Within 1 dB of Conversion Loss  
Max  
Bottom View of
 
SF-1  
Typical Performance Curves  
4X .016
 
± .002  
.506  
.385 Ref  
.220  
.165  
.381  
.002  
.000  
2
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.  
Visit

for additional data sheets and product information.  
For further information and support please visit:  

MD- / MDS-189  
High Level Termination Insensitive Mixer,  
1 – 3500 MHz  
Rev. V4  
Typical Performance Curves  
Ordering Information  
Part Number  
Package  
MD-189 PIN  
FP-2  
MDS-189 PIN  
SF-1  
3
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.  
Visit

for additional data sheets and product information.  
For further information and support please visit:  

MD- / MDS-189  
High Level Termination Insensitive Mixer,  
1 – 3500 MHz  
Rev. V4  
M/A-COM Technology Solutions Inc. All rights reserved.  
Information in this document is provided in connection with M/A-COM Technology Solutions Inc (“MACOM”)  
products. These materials are provided by MACOM as a service to its customers and may be used for  
informational purposes only. Except as provided in MACOM’s Terms and Conditions of Sale for such products or  
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM  
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to  
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update  
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future  
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,  
to any intellectual property rights is granted by this document.  
THESE MATERIALS ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR  
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR  
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR  
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR  
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY  
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN  
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR  
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,  
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.  
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM  
customers using or selling MACOM products for use in such applications do so at their own risk and agree to  
fully indemnify MACOM for any damages resulting from such improper use or sale.  
4
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.  
Visit

for additional data sheets and product information.  
For further information and support please visit: