MASPOWER-MS13N20HGD0
| Part # | MASPOWER-MS13N20HGD0 |
| Download | MASPOWER-MS13N20HGD0 |
MS13N20HGD0
Features
Low gate charge
Low Crss (typical 25pF )
Fast switching
100% avalanche tested
Improved dv/dt capability
RoHS product
Applications
High efficiency switch
mode power supplies
Electronic lamp ballasts
based on half bridge
UPS
Absolute Ratings
(
T
c=25
℃
)
Parameter
Symbol
Value
Unit
Drain-Source Voltage
Drain Current -continuous
Drain Current – pulse
V
DSS
I
D
200
13
V
A
I
DM
52
A
Gate-Source Voltage
V
GSS
E
AS
PD
±30
259
140
V
Single Pulsed Avalanche Energy
Power Dissipation
mJ
W
Operating and Storage
Temperature Range
Tj,T
STG
dv/dt
T
L
-55~+175
5.5
℃
V/ns
℃
Peak Diode Recovery dv/dt
Maximum Lead Temperature for
Soldering Purposes
300
*Drain current limited by maximum junction temperature
Electrical Characteristics
(T
CASE
=25
℃
unless otherwise specified)
Parameter
Symbol Tests
conditions Min
Type Max Units
Off-Characteristics
Drain-Source Voltage
BV
DSS
I
D
=250μA,V
GS
=0V
V
DS
=200V,V
GS
=0V
200
–
–
–
–
V
μA
Drain cut-off current
Gate-body leakage
current,forward
I
DSS
1
I
GSSF
V
DS
=0V,V
GS
=30V
V
DS
=0V,V
GS
=-30V
–
–
–
–
100
nA
nA
Gate-body leakage
current,reverse
I
GSSR
-100
H1.01
Maspower
1
MS13N20HGD0
On-Characteristics
Gate Threshold
Voltage
V
GS(th)
R
DS(ON)
Gfs
V
DS
=V
GS
,I
D
=250uA
2
80
–
–
4
V
mΩ
S
Static Drain-Source
On-Resistance
Forward
V
GS
=10V,I
D
=6.5A
V
DS
=40V,I
D
=6..5A
120 150
14.5
–
Transconductance
Dynamic Characteristics
Input capacitance
Output capacitance
Reverse transfer
capacitance
Ciss
350 1001
1650 pF
VDS=25V,
VGS=0V,
f=1.0MHZ
Coss
Crss
R
G
104 173 300
pF
pF
Ω
15
25
40
Gate Resistance
f=1.0MHZ
0.5
1.5
2.5
Switching Characteristics
td(on)
Turn-On delay time
Turn-On rise time
Turn-Off delay time
Turn-Off Fall time
Total Gate Charge
Gate-Source charge
Gate-Drain charge
9
15.2 21
ns
ns
t
r
16.5 38.7
60
21.5 46.4 71.5
6.8 12.8
18.8
V
DD
=100V,I
D
=13A.,
R
G
=25Ω
T
d(off)
t
f
ns
ns
Qg
12
27.5 42
5.7 8.9
nC
nC
nC
V
DS
=160V,
I
D
=13A,
Qgs
Qgd
2.5
V
GS
=10V
5.8 10.8
15.8
Drain-Source Diode Characteristics and Maximum Ratings
Drain-Source Diode
Forward Voltage
V
SD
VGS=0V,IS=13A
I
S
–
–
–
–
1.4
13
V
A
Maximum Continuous
Drain-Source
Diode Forward Current
Reverse recovery time
trr
124 224 324
0.58 1.38 2.18
ns
V
GS
=0V,IF=13A
dIF/dt=100A/us
Reverse recovery
charge
Qrr
μC
Thermal Characteristic
Parameter
Symbol
R
θJC
Value
0.89
62.5
Unit
Thermal Resistance, Junction-to-Case
Thermal Resistance, Junction-to-Ambient
℃
/W
R
θJA
Notes:
1. Pulse
width limited by maximum junction temperature
2. L=1.6mH,
IAS=13A, VDD=50V, RG=25 Ω,Starting TJ=25
℃
3. ISD
≤13A,di/dt ≤200A/μs, VDD≤BVDSS, Starting TJ=25
℃
4. Pulse
T
est
:
Pulse Width ≤300μs, Duty Cycle≤2
%
5. Essentially
independent of operating temperature
H1.01
Maspower
2
MS13N20HGD0
Test Circuit
H1.01
Maspower
3
MS13N20HGD0
Typical Electrical and Thermal Characteristics (Curves)
H1.01
Maspower
4
MS13N20HGD0
H1.01
Maspower
5
MS13N20HGD0
Package Mechanical DATA
H1.01
Maspower
6