MASPOWER-MS6N120FT

Part #MASPOWER-MS6N120FT
Download 
MASPOWER-MS6N120FT
MS6N120FS/T/C  
Features  
100% avalanche tested  
Avalanche ruggedness  
Very low intrinsic capacitances  
High speed switching  
Very low on-resistance  
Applications  
Welder  
UPS  
PV Inverter  
Switching applications  
Electrical ratings  
Absolute maximum ratings  
Parameter  
Drain-source voltage (V

GS

= 0)  
Symbol  
V

DS  

Value  
Unit  
1200  
± 20  
6
V
Gate- source voltage  
Drain current (continuous) at T

C

= 25 °C  
Drain current (continuous) at T

C

= 100 °C  
Drain current (pulsed)  
V

GS  

I

D  

3.8  
A
I

DM  

12  
Total dissipation at T

C

= 25 °C(TO-247/TO-220)
 
P

TOT  

160  
33  
W
Total dissipation at T

C

= 25 °C(TO-220F)  
Derating factor(TO-247/TO-220)  
Derating factor(TO-220F)  
P

TOT  

W
1.28  
0.26  
W/
℃
 
W/
℃  
Operating junction temperature  
Storage temperature  
T

J  

-55 to 175  
℃
T

stg  

Thermal data  
Value  
Parameter  
Symbol  
Unit  
TO-247  
TO-220F  
TO-220  
Thermal resistance junction-case max  
R

thj-case  

0.78  
3.79  
84  
Thermal resistance junction-ambient max
 
R

thj-amb  

76  
W/
℃  
Maximum lead temperature for soldering  
T

J  

300  
purpose  
H1.05  
Maspower  
1

MS6N120FS/T/C  
Avalanche characteristics  
Parameter  
Symbol  
Max value  
Unit  
Avalanche current, repetitive or not-repetitive  
(pulse width limited by T

J

max)  
I

AR  

2.1  
A
Single pulse avalanche energy  
E

AS  

753  
mJ  
(starting T

J

= 25 °C, I

D

= I

AR

, V

DD

= 50 V)  
Electrical Characteristics
(Tvj = 25°C unless otherwise specified)  
On /off states  
Parameter  
Drain-source  
Symbol  
Test conditions  
Min Typ
 
Max Unit  
V

(BR)DSS  

I

D

= 1 mA, V

GS

= 0  
1200  
V
breakdown voltage  
Zero gate voltage  
V

DS

= Max rating  
I

DSS  

66  
µA  
drain current (V

GS

= 0)  
V

DS

=Max rating, T

C

=125 °C  
Gate-body leakage  
current (V

DS

= 0)  
I

GSS  

V

GS

= ± 30 V  
V

DS

= V

GS

, I

D

= 250 µA  
V

GS

= 10V, I

D

= 4A  
Dynamic  
± 100  
nA  
V
Gate threshold voltage
 
V

GS(th)  

3
4
5
7
Static drain-source on  
R

DS(on)  

5.5  
Ω
resistance  
Parameter  
Symbol Test
 
conditions  
Min Typ
 
Max Unit  
Forward  
g

fs  

V

DS

= 15 V, I

D

= 4  
V

DS

=25V,f=1MHz,V

GS

=0  
V

GS

=0,V

DS

=0 to 1200V  
5.7  
S
transconductance  
Input capacitance  
Output capacitance  
Reverse transfer  
capacitance  
C

iss  

2310  
C

oss  

C

rss  

330  
80  
pF  
Equivalent Output  
capacitance  
C

oss eq.  

120  
2.2  
f=1MHz Gate DC Bias=0  
Test signal level=20mV  
open drain  
Gate input  
resistance  
R

g  

Ω
Q

g  

Q

gs  

Q

gd  

85  
14  
48  
Total gate charge  
Gate-source charge  
Gate-drain charge  
V

DD

=1200V,I

D

=8A  
V

GS

=10V  
nC  
Switching times  
Parameter  
Symbol Test
 
conditions  
Min Typ
 
Max Unit  
Turn-on delay time  
t

d(on)  

V

DD

= 750 V, I

D

= 4 A,  
33  
ns  
H1.05  
Maspower  
2

MS6N120FS/T/C  
Rise time  
Turn-off-delay time  
Fall time  
t

r  

t

d(off)  

t

f  

R

G

= 4.7 Ω, V

GS

= 10 V  
26  
46  
21  
Source drain diode  
Parameter  
Symbol Test
 
conditions  
Min Typ
 
Max Unit  
Source-drain current  
I

SD  

6
A
Source-drain current  
(pulsed)  
I

SDM  

12  
Forward on voltage  
Reverse recovery time  
Reverse recovery charge  
Reverse recovery current  
Reverse recovery time  
Reverse recovery charge  
Reverse recovery current  
Order information  
V

SD  

t

rr  

I

SD

= 6A, V

GS

= 0  
1.5  
360  
5.3  
19  
V
nS  
μ
C  
A
I

SD

= 6A, di/dt= 100A/µs  
V

DD

= 60 V  
Q

rr  

I

RRM  

t

rr  

520  
7.6  
17  
nS  
μ
C  
A
I

SD

=6A, di/dt=100A/µs  
V

DD

= 60V T

J

=150°C  
Q

rr  

I

RRM  

MS6N120FS  
TO-220F  
TO-220  
TO-247  
Tube  
Tube  
Tube  
MS6N120FT  
MS6N120FC  
Electrical characteristics  
H1.05  
Maspower  
3

MS6N120FS/T/C  
H1.05  
Maspower  
4

MS6N120FS/T/C  
H1.05  
Maspower  
5

MS6N120FS/T/C  
Package outline dimension  
H1.05  
Maspower  
6

MS6N120FS/T/C  
H1.05  
Maspower  
7

MS6N120FS/T/C  
H1.05  
Maspower  
8