NTE-ELECTRONICS–INC–NTE5640
| Part # | NTE-ELECTRONICS–INC–NTE5640 |
| Download | NTE-ELECTRONICS–INC–NTE5640 |
NTE5640 thru NTE5643
TRIAC, 2.5A
Absolute Maximum Ratings:
Repetitive Peak Off–State Voltage (Gate Open, T
J
= +100
°
C, Note 1), V
DROM
NTE5640 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100V
NTE5641 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200V
NTE5642 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400V
NTE5643 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600V
RMS On–State Current (T
C
= +75
°
C, Conduction Angle of 360
°
), I
T(RMS)
. . . . . . . . . . . . . . . . .
2.5A
Peak Surge (Non–Repetitive) On–State Current (One Cycle, at 50Hz or 60Hz), I
TSM
. . . . . . . .
30A
Peak Gate–Trigger Current (3
µ
s Max), I
GTM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1A
Peak Gate–Power Dissipation (I
GT
≤
I
GTM
for 3
µ
s Max), P
GM
. . . . . . . . . . . . . . . . . . . . . . . . . . .
20W
Average Gate–Power Dissipation, P
G(AV)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
200mW
Fusing Current (For TRIAC Protection, T = 1.25 to 10ms), I
2
t .
. . . . . . . . . . . . . . . . . . . . . . . . . .
3A
2
s
Operating
T
e
mperature Range,
T
opr
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40
°
to +100
°
C
Storage
T
e
mperature Range,
T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40
°
to +150
°
C
Typical Thermal Resistance, Junction–to–Case, R
thJC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
°
C/W
Note 1.
All values apply in either direction.
Electrical Characteristics:
(At Maximum Ratings and T
C
= +25
°
C unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Peak Off–State Current
I
V
= Max Rating, T
= +100
°
C,
–
–
0.75 mA
DROM
DROM
J
Gate Open, Note 1
Maximum On–State Voltage
DC Holding Current
V
i =
5A (Peak), Note 1
–
–
–
–
–
7
2.2
15
–
V
TM
T
I
Gate Open
mA
V/
µ
s
H
Critical Rate–of–Rise of Off–State Voltage
Critical v
= V
, T
= +100
°
C, Note 1
DROM C
D
dv/dt
DC Gate–Trigger Current
DC Gate–Trigger Voltage
Gate–Controlled Turn–On Time
I
v =
6V, R
= 39
Ω
, All Quads
–
–
–
–
–
25
2.2
–
mA
V
GT
D
L
V
t
v =
6V, R
= 39
Ω
D L
GT
v =
V
T
, I
= 80mA, t
= 0.1
µ
s,
2.2
µ
s
gt
D
DROM GT
r
i =
10A (Peak)
.352 (8.95) Dia Max
.320 (98.13) Dia Max
.250 (6.35)
Max
.500 (12.7)
Min
.019 (0.5) Dia
Gate
MT
2
MT
1
45
°
.031 (.793)