NTE-ELECTRONICS–INC–RLY314

Part #NTE-ELECTRONICS–INC–RLY314
Download 
NTE-ELECTRONICS–INC–RLY314
Special Function
−
Alternating  
Alternating, 10 Amp, AC, SPDT &  
DPDT Cross
−
Wired Contact Relays.  
R66 Series (Includes RLY300)  
Features  
For Duplex Loads  
D60  
SPD
T
, 1
F
orm “C”  
.200 (5.08)  
Input  
Transient Protection  
LED Indicates Output Relay Status  
Compact 8
−
Pin Octal Plug
−
In Case  
Voltage  
Control  
Switch  
L2  
L1  
4
5
6
7
3
2.900  
(73.0)  
2
1
8
Load A:
 
Pin2  
Load B:
 
Pin8  
DPDT Cross
−
Wired  
2 Form “C”  
Input  
Voltage  
L1  
L2  
2.400 (60.96)  
Control  
Switch  
4
5
Lag  
Switch  
3
2
6
7
OPERATION  
1.770  
(44.95)  
1
8
Alternating Relays are used in special applications where the  
optimization of load usage is required by equalizing the run time of two  
loads. This
 
alternating action is initiated by a control switch, such as  
a float switch, manual switch, timing relay, pressure switch, or other  
isolated contact.
 
each time the initiating switch is opened, the relay  
contacts will change state alternating the two loads.  
Load A:
 
Pin8 & L2  
Load B:
 
Pin7 & L2  
Electrical Specifications  
Closed  
Control  
Open  
Switch *  
Load A  
Load B  
Contact  
Rating:
10 Amps resistive at 240VAC, 1/2 HP at 240VAC,  
10 Amps resistive at 30VDC  
Life:
500,000 operations at full load  
Mechanical Life:
 
7,000,000 operations at no load  
Energized  
De
−
Energized  
Energized  
Operational Characteristics  
Voltage Tolerances:
 
+10%,
−
15% at 50/60Hz  
Power Required:
 
3VA  
De
−
Energized  
Alternating Relays with cross
−
wired contacts can operate as normal  
alternating relays when one control switch is used.
 
If a second lag  
switch is used, the relay will simultaneously operate two loads on a first  
ON, last OFF basis.  
Protection  
Transient:
10,000V for 20
 
s  
Closed  
Indicator LED:
 
2 LED’s marked LOAD A and LOAD B  
Control  
Switch 1 *  
Open  
Environmental Characteristics  
Closed  
Open  
Operating:
−
28 C to +65 C  
Control  
Switch 2 *  
Energized  
Load A  
De
−
Energized  
Energized  
De
−
Energized  
Load B  
* With voltage applied  
ACCESSORIES  
AC OPERATED  
MOUNTING  
STYLES  
NTE  
Max.  
DESCRIPTION  
8
−
PIN OCTAL  
8
−
PIN OCTAL  
8
−
PIN OCTAL  
TYPE NO.  
Contact  
Cur. @  
30VDC  
SURFACE MOUNT  
PANEL MOUNT  
R95
−
101  
R95
−
118  
R95
−
113  
Nom.  
Voltage  
Input  
Current  
Diag  
NTE Type No.  
Contact Arr.  
or 240VAC  
No.  
DIN RAIL MOUNT  
RLY314  
24VAC  
120VAC  
240VAC  
24VAC  
125mA  
25mA  
SPDT  
SPDT  
10A  
10A  
10A  
10A  
10A  
10A  
D60  
D60  
D60  
D60  
D60  
D60  
R66
−
5A10
−
120  
R66
−
5A10
−
240  
RLY352  
125mA  
125mA  
25mA  
SPDT  
DPDT (Cross
−
Wired)  
DPDT (Cross
−
Wired)  
DPDT (Cross
−
Wired)  
R66
−
11CA10
−
120 120VAC  
R66
−
11CA10
−
240 240VAC  
125mA  
89  
NTE Electronics, Inc.
 
Voice (973) 748
−
5089 FAX
 
(973) 748
−