NTE-ELECTRONICS–INC–RLY314
| Part # | NTE-ELECTRONICS–INC–RLY314 |
| Download | NTE-ELECTRONICS–INC–RLY314 |
Special Function
−
Alternating
Alternating, 10 Amp, AC, SPDT &
DPDT Cross
−
Wired Contact Relays.
R66 Series (Includes RLY300)
Features
For Duplex Loads
D60
SPD
T
, 1
F
orm “C”
.200 (5.08)
Input
Transient Protection
LED Indicates Output Relay Status
Compact 8
−
Pin Octal Plug
−
In Case
Voltage
Control
Switch
L2
L1
4
5
6
7
3
2.900
(73.0)
2
1
8
Load A:
Pin2
Load B:
Pin8
DPDT Cross
−
Wired
2 Form “C”
Input
Voltage
L1
L2
2.400 (60.96)
Control
Switch
4
5
Lag
Switch
3
2
6
7
OPERATION
1.770
(44.95)
1
8
Alternating Relays are used in special applications where the
optimization of load usage is required by equalizing the run time of two
loads. This
alternating action is initiated by a control switch, such as
a float switch, manual switch, timing relay, pressure switch, or other
isolated contact.
each time the initiating switch is opened, the relay
contacts will change state alternating the two loads.
Load A:
Pin8 & L2
Load B:
Pin7 & L2
Electrical Specifications
Closed
Control
Open
Switch *
Load A
Load B
Contact
Rating:
10 Amps resistive at 240VAC, 1/2 HP at 240VAC,
10 Amps resistive at 30VDC
Life:
500,000 operations at full load
Mechanical Life:
7,000,000 operations at no load
Energized
De
−
Energized
Energized
Operational Characteristics
Voltage Tolerances:
+10%,
−
15% at 50/60Hz
Power Required:
3VA
De
−
Energized
Alternating Relays with cross
−
wired contacts can operate as normal
alternating relays when one control switch is used.
If a second lag
switch is used, the relay will simultaneously operate two loads on a first
ON, last OFF basis.
Protection
Transient:
10,000V for 20
s
Closed
Indicator LED:
2 LED’s marked LOAD A and LOAD B
Control
Switch 1 *
Open
Environmental Characteristics
Closed
Open
Operating:
−
28 C to +65 C
Control
Switch 2 *
Energized
Load A
De
−
Energized
Energized
De
−
Energized
Load B
* With voltage applied
ACCESSORIES
AC OPERATED
MOUNTING
STYLES
NTE
Max.
DESCRIPTION
8
−
PIN OCTAL
8
−
PIN OCTAL
8
−
PIN OCTAL
TYPE NO.
Contact
Cur. @
30VDC
SURFACE MOUNT
PANEL MOUNT
R95
−
101
R95
−
118
R95
−
113
Nom.
Voltage
Input
Current
Diag
NTE Type No.
Contact Arr.
or 240VAC
No.
DIN RAIL MOUNT
RLY314
24VAC
120VAC
240VAC
24VAC
125mA
25mA
SPDT
SPDT
10A
10A
10A
10A
10A
10A
D60
D60
D60
D60
D60
D60
R66
−
5A10
−
120
R66
−
5A10
−
240
RLY352
125mA
125mA
25mA
SPDT
DPDT (Cross
−
Wired)
DPDT (Cross
−
Wired)
DPDT (Cross
−
Wired)
R66
−
11CA10
−
120 120VAC
R66
−
11CA10
−
240 240VAC
125mA
89