Omron-Electronics-G2R-1-S-DC24-S

Part #Omron-Electronics-G2R-1-S-DC24-S
Download 
Omron-Electronics-G2R-1-S-DC24-S
General-purpose Relay  
G2R-
@
-S (S)  
CSM_G2R-
_
-S_(S)_DS_E_1_7  
Slim and Space-saving Power Plug-in Relay  
■
Reduces wiring work by 60% when combined with the  
P2RF-
@
-PU Push-In Plus Socket  
LR  
(according to actual OMRON measurements).  
■
Lockable test button models available.  
■
Built-in mechanical operation indicator.  
■
Provided with nameplate.  
■
AC type is equipped with a coil-disconnection self-diagnostic  
function (LED type).  
■
High switching power (1-pole: 10 A).  
For the most recent information on models that have been certified for  
safety standards, refer to your OMRON website.  
Model Number Structure  
Model Number Legend  
G2R –  
– S  
2
(S)  
5
1
3
4
1. Number of Poles  
4. Rated Coil Voltage  
5. Mechanical operation indicator and Nameplate  
1:  
2:  
1 pole  
2 poles  
(S):  
Models with mechanical operation indicator and Nameplate  
2. Terminals  
S:  
Plug-in  
3. Classification  
Blank: General-purpose  
N:  
D:  
LED indicator  
Diode  
ND: LED
 
indicator and diode  
NI: LED
 
indicator with test button  
NDI: LED
 
indicator and diode with test button  
Note:
Contact your OMRON representative for Relays with gold-plated contacts.  
When your order, specify the rated voltage.  
Ordering Information  
List of Models  
Contact form  
Classification  
Coil ratings  
SPDT  
DPDT  
General-purpose  
G2R-1-S (S)  
G2R-2-S (S)  
AC 24, 48, 110, 120, 230, 240  
DC 6, 12, 24, 48  
LED indicator  
G2R-1-SN (S)  
G2R-1-SNI (S)  
G2R-1-SD (S)  
G2R-1-SND (S)  
G2R-1-SNDI (S)  
G2R-2-SN (S)  
G2R-2-SNI (S)  
G2R-2-SD (S)  
G2R-2-SND (S)  
G2R-2-SNDI (S)  
LED indicator with test button  
Diode  
LED indicator and diode  
DC 6, 12, 24, 48  
LED indicator and diode with test button  
Note: 1.
 
The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combina-  
tions with the P2RF-
@
-E, P2RF-
@
-S and P2RF-
@
-PU. The Relays bear the CE Marking.  
2.
Refer to
Connecting Sockets
, below, for applicable Socket models.  
3.
When ordering, add the rated coil voltage and “(S)” to the model number. Rated coil voltages are given in the coil ratings table.  
Example: G2R-1-S 12 VDC (S)  
Rated coil voltage  
1

G2R-
@
-S (S)  
Accessories (Order Separately)  
Connecting Sockets  
Track/surface-mounting Socket  
Back-mounting Socket  
Push-In Plus  
Applicable Relay model  
No. of poles  
Screw terminals *  
Models  
PCB terminals  
Models  
Solder terminals  
Model  
Terminal Blocks  
Model  
P2RFZ-05-E  
P2RF-05  
P2RF-05-E  
P2R-05P  
P2R-057P  
1 pole  
G2R-1-S (S)  
G2R-2-S (S)  
P2RF-05-PU  
P2R-05A  
P2RFZ-08-E  
P2RF-08  
P2RF-08-E  
P2R-08P  
P2R-087P  
2 poles  
P2RF-08-PU  
P2R-08A  
*
T
he structure of P2RF-
@
-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals.  
Accessories for Push-In Plus Terminal Block Sockets (P2RF-
@
-PU)  
Short Bars  
Pitch  
No. of poles  
Colors  
Model
*
 
PYDN-7.75-020
@  
PYDN-7.75-030
@  
PYDN-7.75-040
@  
PYDN-7.75-200
@  
PYDN-15.5-080
@  
Minimum order (quantity)  
2
3
Red (R)  
Blue (S)  
Yellow (Y)  
7.75 mm  
4
10  
20  
8
15.5 mm  
Note:
Use the Short Bars for crossover wiring within one Socket or between Sockets.  
* Replace
 
the box (
@
) in the model number with the code for the covering color.  
Labels  
Minimum order (sheet)  
Model  
(quantity per sheet)  
5
XW5Z-P4.0LB1  
1 sheet (60 pieces)  
Accessories for Screw Terminal Sockets (P2RFZ-
@
-E)  
Short Bars  
Pitch  
No. of poles  
Colors  
Model  
Minimum order (set)  
6.8 mm  
10  
P2DN-6.8-100S  
1
Blue (S)  
One set (order unit) contains  
10 short bars and 20 caps.  
15.7 mm  
10  
P2DN-15.7-100S  
Note: 1.
 
Use the Short Bars for crossover wiring within one Socket or between Sockets.  
2.
Cannot be used on the P2RF-
@
-E.  
Labels  
Minimum order (sheet)  
Model  
(quantity per sheet)  
5
XW5Z-P2.5LB1  
1 sheet (72 pieces)  
Accessories for Short Bars (P2DN)  
Cap  
Model  
P2DN-CP100  
Minimum order (bag)  
1
(100 pcs./bag)  
Mounting Tracks  
Minimum order  
(quantity)  
Applicable Socket  
Description  
Model  
50 cm (
l
) × 7.3 mm (t):
 
PFP-50N  
1 m (
l
) × 7.3 mm (t):
 
PFP-100N  
1 m (
l
) × 16 mm (t):  
—  
Mounting track  
Track-connecting Socket  
PFP-100N2  
PFP-M  
End plate *1  
Spacer  
10  
1
PFP-S  
Back-connecting Socket
 
Mounting plate *2  
*1
.
W
hen mounting DIN rail, please use End Plate (PFP-M).  
*2
.
U
sed to mount several P2R-05A and P2R-08A Connecting Sockets side by side.  
P2R-P  
2

G2R-
@
-S (S)  
Specifications  
Coil Ratings  
Must  
operate  
voltage  
Must  
release  
voltage  
Coil inductance (H)  
(ref. value)  
Max.  
voltage  
Rated current*  
Power  
consumption  
(approx.)  
Coil  
resistance  
Rated voltage  
Armature Armature  
50 Hz  
60 Hz  
% of rated voltage  
OFF  
ON  
24 V  
48 V  
110 V  
43.5 mA  
21.8 mA  
9.5 mA  
8.6 mA  
4.4 mA  
4.2 mA  
37.4 mA  
18.8 mA  
8.2 mA  
7.5 mA  
3.8 mA  
3.7 mA  
253
Ω
 
0.81  
1.55  
1,040
Ω  
5,566
Ω  
7,286
Ω  
27,172
Ω  
27,800
Ω  
3.12  
6.17  
13.33  
16.13  
72.68  
90.58  
26.83  
32.46  
143.90  
182.34  
AC  
80% max.
 
30% max.
 
110%  
0.9 VA at 60 Hz  
120 V  
230 V  
240 V  
Must  
operate  
voltage  
Must  
release  
voltage  
Coil inductance (H)  
(ref. value)  
Max.  
voltage  
Power  
consumption  
(approx.)  
Coil  
resistance  
Rated voltage  
Rated current*  
Armature Armature  
% of rated voltage  
OFF  
ON  
6 V  
87.0 mA  
43.2 mA  
21.6 mA  
11.4 mA  
69
Ω  
0.25  
0.48  
12 V  
278
Ω  
0.98  
3.60  
15.2  
2.35  
8.25  
29.82  
DC  
70% max.
 
15% min.  
110%  
0.53 W  
24 V  
48 V  
1,113
Ω  
4,220
Ω  
Note: 1.
 
The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for the AC rated current  
and ±10% for the DC coil resistance.  
2.
The AC coil resistance and inductance values are reference values only (at 60 Hz).  
3.
Operating characteristics were measured at a coil temperature of 23°C.  
4.
The maximum voltage is the maximum possible value of the voltage that can be applied to the relay coil.  
It is not the maximum voltage that can be applied continuously.  
Contact Ratings  
Number of poles  
1 pole  
2 poles  
Resistive load  
(cos
φ
= 1)  
Inductive load  
(cos
φ
= 0.4; L/R = 7 ms)  
Resistive load  
(cos
φ
= 1)  
Inductive load  
(cos
φ
= 0.4; L/R = 7 ms)  
Load  
10 A at 250 VAC;  
10 A at 30 VDC  
7.5 A at 250 VAC;  
5 A at 30 VDC  
5 A at 250 VAC;  
5 A at 30 VDC  
2 A at 250 VAC; 3 A at  
30 VDC  
Rated load  
Rated carry current  
10 A  
5 A  
Max. switching voltage  
Max. switching current  
440 VAC, 125 VDC  
10 A  
380 VAC, 125 VDC  
5 A  
2,500 VA,  
300 W  
1,875 VA,  
150 W  
1,250 VA,  
150 W  
500 VA,  
90 W  
Max. switching power  
Failure rate (reference value) *
 
100 mA at 5 VDC  
Note:
P level:
λ
60
= 0.1 x 10

-6

/operation  
10 mA at 5 VDC  
*
T
his value was measured at a switching frequency of 120 operations per minute.  
3

G2R-
@
-S (S)  
Characteristics  
Item  
1 pole  
2 poles  
Contact configration  
Contact structure  
Contact resistance  
Operate (set) time  
SPDT  
Single  
100 m
Ω
max.  
15 ms max.  
AC: 10 ms max.; DC: 5 ms max.  
(w/built-in diode: 20 ms max.)  
AC: 15 ms max.; DC: 10 ms max.  
(w/built-in diode: 20 ms max.)  
Release (reset) time  
Max. operating  
frequency  
Mechanical:  
Electrical:  
18,000 operations/hr  
1,800 operations/hr (under rated load)  
Insulation resistance
 
1,000 M
Ω
min. (at 500 VDC)  
5,000 VAC, 50/60 Hz for 1 min between coil and  
5,000 VAC, 50/60 Hz for 1 min between coil and contacts;  
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity  
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity  
contacts;  
Dielectric strength *  
1,000 VAC, 50/60 Hz for 1 min between contacts of  
same polarity  
Destruction:  
Malfunction:  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
Vibration resistance  
Shock resistance  
Destruction:  
Malfunction:  
1,000 m/s

2  

200 m/s

2

when energized; 100 m/s

2

when not energized  
Mechanical:  
AC coil: 10,000,000 operations min.;  
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)  
100,000 operations min. (at 1,800 operations/hr under rated load)  
Endurance  
Electrical:  
Ambient temperature
 
Operating:  
–40
°
C to 70
°
C (with no icing or condensation)  
Ambient humidity  
Weight  
Operating:  
5% to 85%  
Approx. 20 g  
Note:
Values in the above table are the initial values.  
*
T
hese values are relay only. Prease refer to the “Products Related to Common Sockets and DIN Tracks Data Sheet” for connecting sockets.  
Approved Standards  
UL 508 (File No. E41643)  
IEC/VDE (Certificate No. 40015012 EN 61810-1)  
Contact  
form  
Opera-  
tions  
Contact  
form  
Model  
Coil ratings  
Contact ratings  
Coil ratings  
Contact ratings  
Operations  
10 A, 30 VDC (resistive)  
10 A, 250 VAC (general use)  
6, 12, 24, 48 VDC  
24, 110, 120, 230,  
240 VAC  
5 A, 440 VAC (cos
φ
= 1.0)  
10 A, 250 VAC (cos
φ
= 1.0)  
10 A, 30 VDC (0 ms)  
100 × 10

3  

25 × 10

3  

100 × 10

3  

25 × 10

3  

1 pole  
100 × 10

3  

G2R-1-S (S)
 
SPDT  
G2R-2-S (S)
 
DPDT  
TV-3 (NO contact only)  
5 to 110 VDC  
6 to 240 VAC  
6, 12, 24, 48 VDC  
24, 110, 120, 230,  
240 VAC  
5 A, 30 VDC (resistive)  
5 A, 250 VAC (general use)  
5 A, 250 VAC (cos
φ
=1.0)  
5 A, 30 VDC (0 ms)  
2 poles  
100 × 10

3  

TV-3 (NO contact only)  
LR  
Number  
CSA 22.2 No.0, No.14  
(File No. LR31928)  
Coil ratings  
Contact ratings  
Operations  
of poles  
Contact  
form  
Opera-  
tions  
10 A, 250 VAC (general use)  
Model  
Coil ratings  
Contact ratings  
5 to 110 VDC
 
7.5 A, 250 VAC (PF0.4)  
6 to 240 VDC
 
10 A, 30 VDC (resistive)  
5A, 30VDC (L/R=7ms)  
1 pole  
100 × 10

3  

10 A, 30 VDC (resistive)  
10 A, 250 VAC (general use)  
100 × 10

3  

25 × 10

3  

100 × 10

3  

25 × 10

3  

G2R-1-S (S)
 
SPDT  
G2R-2-S (S)
 
DPDT  
5 A, 250 VAC (general use)  
5 to 110 VDC
 
2 A, 250 VAC (PF0.4)  
6 to 240 VDC
 
5 A, 30 VDC (resistive)  
3A, 30VDC (L/R=7ms)  
TV-3 (NO contact only)  
5 to 110 VDC  
6 to 240 VAC  
2 poles  
100 × 10

3  

5 A, 30 VDC (resistive)  
5 A, 250 VAC (general use)  
TV-3 (NO contact only)  
4

G2R-
@
-S (S)  
Engineering Data  
Maximum Switching Power  
G2R-2-S (S)  
G2R-1-S (S)  
100  
10  
1
100  
AC inductive load  
AC resistive  
load  
(cos
φ
= 0.4)  
AC inductive load  
AC resistive  
load  
(cos
φ
= 0.4)  
10  
1
DC resistive  
load  
DC resistive  
load  
DC inductive load  
(L/R = 7 ms)  
DC inductive load  
(L/R = 7 ms)  
0.1  
0.1  
1
10  
100  
1000  
1
10  
100  
1000  
Switching voltage (V)  
Switching voltage (V)  
Endurance  
G2R-1-S (S)  
G2R-2-S (S)  
10,000  
5,000  
5,000  
250-VAC/30-VDC  
resistive load  
1,000  
500  
1,000  
500  
250-VAC inductive load  
(cos
φ
= 0.4)  
30-VDC inductive load (L/R = 7ms)  
250-VAC/30-VDC  
resistive load  
100  
100  
50  
30-VDC inductive load (L/R = 7ms)  
250-VAC  
inductive load  
(cos
φ
= 0.4)  
50  
Switching current (A)  
Switching current (A)  
Ambient Temperature vs Maximum Coil Voltage  
DC coil  
AC coil  
Ambient temperature (
°
C)  
5

G2R-
@
-S (S)  
Dimensions  
(Unit: mm)  
Note:
All units are in millimeters unless otherwise indicated.  
SPDT Relays  
G2R-1-S (S), G2R-1-SN (S), G2R-1-SNI (S)  
G2R-1-SD (S), G2R-1-SND (S), G2R-1-SNDI (S)  
Terminal Arrangement/Internal Connections  
(Bottom View)  
G2R-1-SD (S) (DC)  
G2R-1-S (S)  
1
1
5
29 max.  
13 max.  
2
4
3
5
2
4
3
G2R-1-SN (S), G2R-1-SNI (S) (AC)
 
G2R-1-SN (S), G2R-1-SNI (S) (DC)  
1
5
1
5
DC24V  
0.5  
4.75  
2
4
3
2
4
3
G2R-1-SND (S), G2R-1-SNDI (S) (DC)  
5.2  
5.2  
17.5  
1
2
4
3
5
DPDT Relays  
G2R-2-S (S), G2R-2-SN (S), G2R-2-SNI (S)  
G2R-2-SD (S), G2R-2-SND (S), G2R-2-SNDI (S)  
Terminal Arrangement/Internal Connections  
(Bottom View)  
G2R-2-S (S)  
G2R-2-SD (S) (DC)  
1
2
7
3
6
4
5
1
8
2
7
3
6
4
5
13 max.  
29 max.  
8
G2R-2-SN (S), G2R-2-SNI (S) (AC)  
G2R-2-SN (S), G2R-2-SNI (S) (DC)  
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
5
0.5  
2.5  
2.4  
G2R-2-SND (S), G2R-2-SNDI (S) (DC)  
5
5
19.4  
1
8
2
7
3
6
4
5
6

G2R-
@
-S (S)  
Track/Surface Mounting Sockets  
P2RF-05-PU  
57.5  
53.1  
Terminal Arrangement/  
Internal Connection Diagram  
(Top View)  
Mounting Hole  
Dimensions  
A2 A1  
30.8  
28.1  
(1)  
(5)  
(4.2)  
25.6  
T
w
o M3 screw  
holes or  
two 3.5-dia. holes  
108  
Release lever  
90  
35.3  
12  
(2)  
14  
(3)  
27.35  
11  
(4)  
Note:
Pull out the hooks to  
mount the Socket  
with screws.  
(4.2)  
3.9  
Note:
The numbers in  
parentheses are  
25.6  
15.5  
34.3  
43  
52.1  
traditionally used  
terminal numbers.  
P2RF-08-PU  
57.5  
Terminal Arrangement/  
Internal Connection Diagram  
(Top View)  
53.1  
30.8  
28.1  
Mounting Hole  
Dimensions  
A2  
(1)  
A1  
(8)  
(4.2)  
25.6  
T
w
o M3 screw  
holes or  
two 3.5-dia. holes  
Release lever  
90  
108  
35.3  
12  
(2)  
22  
(7)  
27.35  
14  
(4)  
24  
(5)  
11  
(3)  
21  
(6)  
(4.2)  
3.9  
Note:
Pull out the hooks to  
mount the Socket  
with screws.  
25.6  
15.5  
34.3  
43  
52.1  
Note:
The numbers in  
parentheses are  
traditionally used  
terminal numbers.  
Accessories for P2RF-
@
-PU  
Short Bars  
No. of  
poles  
Maximum  
carry current  
Application  
Pitch  
L (Length)  
Colors  
Model

*  

PYDN-7.75-
@@
(7.75 mm)  
2
3
15.1  
22.85  
30.6  
PYDN-7.75-020
@  
PYDN-7.75-030
@  
PYDN-7.75-040
@  
PYDN-7.75-200
@  
For Contact  
terminals  
(common)  
3.90  
L
7.75 mm  
15.5 mm  
Red (R)  
Blue (S)  
Yellow (Y)  
4
20 A  
20  
154.6  
18.5  
12  
For Coil  
terminals  
8
115.85  
PYDN-15.5-080
@  
2.25  
1.57  
*
R
eplace the box (
@
) in the model number with the code for the covering color.  
Note: 1.
 
Use the Short Bars for crossover wiring within one Socket or between Sockets.  
2.
When using short bar to coil terminals of PYF-
@@
-PU, make sure to use PYDN-31.0-  
080
@
(31 mm).  
PYDN-15.5-080
@
(15.5 mm)  
3.90  
115.85  
When using short bar to coil terminals of P2RF-
@@
-PU, make sure to use PYDN-15.5-  
080
@
(15.5 mm).  
18.5  
12  
1.57  
2.25  
7

G2R-
@
-S (S)  
P2RFZ-05-E  
Terminal Arrangement/  
Internal Connection Diagram  
(Top View)  
Mounting Hole  
Dimensions  
2
48 max.  
5-M3X8  
3.2-dia.  
hole  
4
ꢀ±.5  
(42.3)  
(35.8)  
2
39.5  
3
78.5 max.  
39.5±±.ꢀ  
3.5-dia.  
hole  
35.5  
M3 or  
3.5-dia.  
hole  
ꢀ7.2  
4
5
1
3ꢀ max.  
6ꢀ max.  
ꢀ6 max.  
P2RFZ-08-E  
Mounting Hole  
Dimensions  
Terminal Arrangement/  
Internal Connection Diagram  
(Top View)  
8-M3X8  
2
48 max.  
2
3.2-dia. hole  
ꢀ±.5  
6
3
(42.3)  
39.5  
7
5
2
4
39.5±±.ꢀ  
78.5 max.  
(35.8)  
3.5-dia.  
hole  
35.5  
M3 or  
3.5-dia.  
hole  
ꢀ7.2  
8
1
4
3ꢀ max.  
6ꢀ max.  
ꢀ6 max.  
Accessories for P2RFZ-
@
-E  
Short Bars  
P2DN-6.8-100S (6.8 mm)  
Maximum carry current: 20A  
ꢀ5.7±±.ꢀ  
6.8±±.ꢀ  
2.9  
9
ꢀ5.4 max.  
2.5 max.  
8.7 max.  
ꢀ52.7 max.  
P2DN-15.7-100S (15.7 mm)  
Maximum carry current: 20A  
ꢀ5.7±±.ꢀ  
2.9  
9
ꢀ.6-dia.  
ꢀ5.4 max.  
2.5 max.  
8.7 max.  
ꢀ52.7 max.  
Note:
Each Short Bar set comes with 20 Caps.  
Accessories for P2DN  
Cap  
P2DN-CP100  
5.2 max.  
4 max.  
6 max.  
8

G2R-
@
-S (S)  
P2RF-05-E  
7
0.2  
Terminal Arrangement  
(Top View)  
Mounting Holes  
(for Surface Mounting)  
2
Five, M3.5´7  
48 max.  
3.2-dia.  
hole  
(11)  
4
2
(12)  
3
39.5  
(14)  
35.5  
39.5 0.1  
85.5 max.  
3.5-dia.  
hole  
M3 or  
3.5-dia.  
hole  
5
(A1)  
(A2)  
1
4
11.5  
61 max.  
16.0 max.  
Note:
Pin numbers in parentheses apply to DIN standard.  
P2RF-08-E  
+0.2  
6
−
0.1  
Terminal Arrangement  
(Top View)  
Mounting Holes  
(for Surface Mounting)  
2
1.5  
Eight, M3´8  
2
48.0 max.  
3
(11)  
(12)  
(14)  
(21)  
(22)  
(24)  
6
3
2
4
3.2-dia.  
hole  
7
5
39.5  
35.5  
85.5  
max.  
39.5 0.1  
8
3.5-dia. hole  
M3 or  
3.5-dia.  
hole  
(A1)  
1
(A2)  
4
11.5  
61.0  
max.  
16.0 max.  
2
P2RF-05  
Terminal Arrangement  
(Top View)  
Mounting Holes  
(for Surface Mounting)  
7
Five, M3.5 x 8  
4-dia. holes  
4.2-dia. hole  
35.5  
71.5 max.  
30 0.05  
19.5  
30 max.  
4
M3 or 3.2-dia.  
hole  
19.5 max.  
54 max.  
P2RF-08  
2
7
Terminal Arrangement  
Mounting Holes  
Eight, M3.5 x 8  
4-dia. holes
 
(Top View)  
(for Surface Mounting)  
4.2-dia. hole  
35.5  
71.5 max.  
30 0.05  
19.5  
4
30 max.  
19.5 max.  
M3 or 3.2-dia.  
hole  
54 max.  
9

G2R-
@
-S (S)  
Mounting Height of Relay with Track/Surface Mounting Sockets  
P2RF-05-PU  
P2RF-08-PU  
G2R-
@
-S (S)  
G2R-
@
-S (S)  
Relay  
Relay  
P2RF-05
ー
PU  
P2RF-08
ー
PU  
Socket  
Socket  
63.6  
63.6  
28.1  
28.1  
(3.9)  
(3.9)  
P2RFZ-E  
G2R-
@
-S (S)  
Relay  
P2RFZ-
@
-E  
Socket  
67.0  
70.5  
P2RF-
@
 
P2RF-
@
-E  
G2R-
@
-S (S)  
Relay  
G2R-
@
-S (S)  
Relay  
P2RF-
@
-E  
Socket  
P2RF-
@  
Socket  
67.0  
62.0  
66.5  
70.5  
10  

G2R-
@
-S (S)  
Back-connecting Sockets  
Terminal Arrangement  
(Bottom View)  
Mounting Holes  
T
o
lerance: 0.1  
P2R-05P (1-pole)  
14.5 max.  
4
7
1
4
Five,  
6
1.6-dia.  
holes  
4.5  
6
35.5 max.  
15  
4.5  
15  
1.2  
4
3.5  
1.5  
4
(5)  
4
7
7
36.5 max.  
P2R-08P (2-pole)  
Terminal Arrangement  
(Bottom View)  
Mounting Holes  
14.5 max.  
4
7
0.3  
Eight, 1.3-dia. holes  
7.5  
5
5
5
5
35.5 max.  
20  
1
2.8  
20  
1.5  
7.5  
(4.3)  
T
e
rminal plate thickness: 0.3  
36.5 max.  
4.5  
7.5  
P2R-05A (1-pole)  
14.5 max.  
1.2  
0.3  
Terminal Arrangement  
(Bottom View)  
6.7  
3.8  
35.5 max.  
5
16.7  
Panel Cutout  
Five, 3 x 1.8-dia. holes  
6
13.6 0.1  
36.5 max.  
1.2  
T
e
rminal plate thickness: 0.3  
30.5 0.2  
6.5 7.5  
14.5 max.  
P2R-08A (2-pole)  
0.3  
2.6  
5
5
35.5 max.  
Recommended thickness of  
the panel is 1.6 to 2.0 mm  
20  
2.8  
1.5  
Eight, 3 x 1.2-dia. holes  
7.5  
T
e
rminal plate thickness: 0.3  
36.5 max.  
11  

G2R-
@
-S (S)  
P2R-057P (1-pole)  
Mounting Holes  
16.4  
10.4 3.5  
Terminal Arrangement  
(Bottom View)  
14 max.  
8.7  
1
0.7  
Five,  
1.6-dia.  
holes  
4 0.1  
1
1
6
4.5  
6 0.1  
29.6  
15  
37 max.  
4
8.75  
4.5 0.1  
15 0.1  
4 0.1  
5
8.7  
7.4  
7 0.1  
41 max.  
16.4  
14 max.  
7.5  
Mounting Holes  
P2R-087P (2-pole)  
Terminal Arrangement  
(Bottom View)  
10.4  
3.5  
1
Eight,  
1.3-dia.  
holes  
0.3  
1
7.5  
5
5
29.1  
37 max.  
20  
5
5
8.1  
20  
8.9  
7.4  
(8.1)  
41 max.  
Mounting Height of Relay with Back-connecting Sockets  
P2R-
@
P  
P2R-
@
A  
P2R-
@
7P  
G2R-
@
-S (S) Relay  
G2R-
@
-S (S) Relay  
G2R-
@
-S (S) Relay  
44.5  
47.5  
38.0  
P2R-
@
P  
P2R-
@
A  
Socket  
P2R-
@
7P  
Socket  
Socket  
Mounting Tracks  
PFP-100N, PFP-50N  
PFP-100N2  
16  
7.3 0.15  
35 0.3  
15 (5)  
4.5  
4.5  
27  
29.2  
1.5  
24  
27 0.15  
1
35 0.3  
15  
25  
25  
15 25  
25  
25  
15 25  
25  
25  
1
10  
10  
10  
10  
1,000  
1,000 (500)  
It is recommended to use a panel 1.6 to 2.0 mm thick.  
12  

G2R-
@
-S (S)  
End Plate  
Spacer  
16  
12  
10  
6.2  
PFP-M  
PFP-S  
5
1.8  
1
35.5 35.3  
50  
34.8  
44.3  
1.8  
11.5  
1.3  
4.8  
10  
M4 x 8 pan  
head screw  
16.5  
Mounting Plate  
P2R-P  
90  
4.5  
13.6  
R2.25  
10-
Ellipse hole  
3.4  
0.1  
42  
49  
30.5  
0.15  
0.15  
0.15  
0.15  
18  
18  
18  
18  
Square hole  
0.1  
0.1  
9
9
0.2  
t=1.6 mm  
72  
13  

G2R-
@
-S (S)  
Safety Precautions  
Be sure to read the
Common Precautions for All Relay
in the website at the following URL:  
Refer to
Products Related to Common Sockets and DIN Tracks
for precautions on the applicable Sockets.  
Refer to
PYF-
@@
-PU/P2RF-
@@
-PU
for precautions on Push-In Plus Terminal Block Sockets.  
•
When cutting with a tool, insert the tool from the plastic part and cut  
along the slot in the plastic part between terminals. If you cut a part  
Warning Indications  
Indicates a potentially hazardous  
situation which, if not avoided, may result  
in minor or moderate injury or in property  
damage.  
other than the slot in the plastic part between terminals, it may not  
be possible to attach the insulating cap.  
CAUTION  
Supplementary comments on what to do  
or avoid doing to prevent failure to  
operate, malfunction, or undesirable  
effects on product performance.  
Precautions for  
Correct Use  
Cation  
•
Do not use the test button for any purpose other than testing. Be  
sure not to touch the test button accidentally as this will turn the  
contacts ON. Before using the test button, confirm that circuits, the  
load, and any other connected item will operate safely.  
•
Check that the test button is released before turning ON relay cir-  
cuits.  
•
When using a cut short-circuit bar (P2DN), always use the provid-  
ed cap to protect the charger part.  
•
If the test button is pulled out too forcefully, it may bypass the mo-  
mentary testing position and go straight into the locked position.  
•
Use an insulated tool when you operate the test button.  
Precautions for Correct Use  
About the Built-in Diodes  
•
The proper orientation for installing the short-circuit bar is with the  
The diodes that are built into the Relays are designed to absorb  
reverse voltage from the Relay’s coil. If a large surge in voltage is  
applied to the diode from an external source, the element will be  
destroyed.  
molded part facing inward.  
If there is the possibility of large voltage surges that could be applied  
to the elements from an external source, take any necessary surge  
absorption measures.  
Latching Levers  
• Turn
 
OFF the power supply when operating the latching lever.  
After you use the latching lever always return it to its original state.  
• Do
 
not use the latching lever as a switch.  
• The
 
latching lever can be used for 100 operations minimum.  
•
Use the short-circuit bar to short-circuit two or more coil terminals,  
or two or more contact COM terminals.  
•
Do not use a deformed short-circuit bar. Risk of failure, malfunc-  
tioning, or deterioration of characteristics.  
•
In socket terminals, insert the short-circuit bar in the correct orien-  
tation all the way into all terminals, and then secure with screws.  
•
Install the short -circuit bar before wiring.  
Relay Replacement  
To replace the Relay, turn OFF the power supply to the load and  
Relay coil sides to prevent unintended operation and possible  
electrical shock.  
Coil tape color  
Pink tape is used for the AC coil type and blue tape is used for the DC  
coil type, making it easy to distinguish AC and DC.  
Equivalent Labels from Other Companies and  
Recommended Label Printers  
Using a short-circuit bar  
•
Use the short-circuit bar that is suitable for the socket you are using  
and the location of use.  
•
Note that the P2DN short-circuit bar for the P2RFZ-E Socket has  
both a short-circuit bar for shorting coil terminals and a short-circuit  
bar for shorting contact COM terminals.  
•
The short-circuit bar can be cut to match any number of poles. Cut  
with a tool as appropriate for the number of relays and sockets.  
When using a cut short-circuit bar, take care to avoid injuring your-  
self on the cut surface.  
Use the following label printer.  
The following table gives the manufacturer’s model number as of  
March 2017.  
Phoenix  
Contact  
Manufacturer  
Omron  
Weidmuller  
Cembre  
MG-CPM-04  
41391  
XW5Z-P4.0LB1
UCT-TM6  
XW5Z-P2.5LB2
UCT-TMF5  
MF 10/6  
—  
Label  
—  
BLUEMARK  
CLED,  
THERMOMA  
PrintJet  
ADVCANCED,  
Plotter MCP
 
Markingenius  
Plus,  
Plotter MCP  
Basic  
Label printer  
—
*
 
RK CARD  
MG3  
SET PLUS,  
THERMOMA  
RK CARD  
* When
 
using a printing tool, use a Phoenix Contact label printer.  
Note:
Ask the label manufacturer or printer manufacturer for details.  
14  

OMRON AUTOMATION AMERICAS HEADQUARTERS •
Chicago, IL USA
•
847.843.7900
•
800.556.6766
•
automation.omron.com  
OMRON CANADA, INC. • HEAD OFFICE  
OMRON ELETRÔNICA DO BRASIL
L
T
DA • HEAD OFFICE  
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 •
automation.omron.com  
São Paulo, S
P
,
B
rasil • 55 11 5171-8920 • automation.omron.com  
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE  
Ciudad de México • 52.55.5901.4300 • 01.800.386.6766 • mela@omron.com  
OMRON ARGENTINA • SALES OFFICE  
Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483  
OMRON ELECTRONICS DE MEXICO • SALES OFFICE  
San Pedro Garza García, N.L. • 81.12.53.7392 • 01.800.386.6766 • mela@omron.  
com  
OTHER OMRON LATIN AMERICA SALES  
+54.11.4521.8630 • +54.11.4523.8483 • mela@omron.com  
OMRON ELECTRONICS DE MEXICO • SALES OFFICE  
Eugenio Garza Sada,León, Gto • 01.800.386.6766
 
• mela@omron.com  
Authorized Distributor:  
Controllers & I/O  
• Machine Automation Controllers (MAC) • Motion Controllers  
• Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O  
Robotics  
• Industrial Robots • Mobile Robots  
Operator Interfaces  
• Human Machine Interface (HMI)  
Motion & Drives  
• Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems  
• Frequency Inverters  
Vision, Measurement & Identification  
• Vision Sensors & Systems • Measurement Sensors • Auto Identification  
Systems  
Sensing  
• Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors  
• Rotary Encoders • Ultrasonic Sensors  
Safety  
• Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems  
• Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices  
• Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays  
Control Components  
• Power Supplies • Timers • Counters • Programmable Relays  
• Digital Panel Meters • Monitoring Products  
Switches & Relays  
• Limit Switches • Pushbutton Switches • Electromechanical Relays  
• Solid State Relays  
Software  
• Programming & Configuration
 
• Runtime  
J140-E3-02  
Note: Specifications are subject to change.  
© 2020 Omron. All Rights Reserved.  
Printed in U.S.A.  
Printed on recycled paper.