Omron-Electronics-G2R-1-S-DC24-S
| Part # | Omron-Electronics-G2R-1-S-DC24-S |
| Download | Omron-Electronics-G2R-1-S-DC24-S |
General-purpose Relay
G2R-
@
-S (S)
CSM_G2R-
_
-S_(S)_DS_E_1_7
Slim and Space-saving Power Plug-in Relay
■
Reduces wiring work by 60% when combined with the
P2RF-
@
-PU Push-In Plus Socket
LR
(according to actual OMRON measurements).
■
Lockable test button models available.
■
Built-in mechanical operation indicator.
■
Provided with nameplate.
■
AC type is equipped with a coil-disconnection self-diagnostic
function (LED type).
■
High switching power (1-pole: 10 A).
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
G2R –
– S
2
(S)
5
1
3
4
1. Number of Poles
4. Rated Coil Voltage
5. Mechanical operation indicator and Nameplate
1:
2:
1 pole
2 poles
(S):
Models with mechanical operation indicator and Nameplate
2. Terminals
S:
Plug-in
3. Classification
Blank: General-purpose
N:
D:
LED indicator
Diode
ND: LED
indicator and diode
NI: LED
indicator with test button
NDI: LED
indicator and diode with test button
Note:
Contact your OMRON representative for Relays with gold-plated contacts.
When your order, specify the rated voltage.
Ordering Information
List of Models
Contact form
Classification
Coil ratings
SPDT
DPDT
General-purpose
G2R-1-S (S)
G2R-2-S (S)
AC 24, 48, 110, 120, 230, 240
DC 6, 12, 24, 48
LED indicator
G2R-1-SN (S)
G2R-1-SNI (S)
G2R-1-SD (S)
G2R-1-SND (S)
G2R-1-SNDI (S)
G2R-2-SN (S)
G2R-2-SNI (S)
G2R-2-SD (S)
G2R-2-SND (S)
G2R-2-SNDI (S)
LED indicator with test button
Diode
LED indicator and diode
DC 6, 12, 24, 48
LED indicator and diode with test button
Note: 1.
The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combina-
tions with the P2RF-
@
-E, P2RF-
@
-S and P2RF-
@
-PU. The Relays bear the CE Marking.
2.
Refer to
Connecting Sockets
, below, for applicable Socket models.
3.
When ordering, add the rated coil voltage and “(S)” to the model number. Rated coil voltages are given in the coil ratings table.
Example: G2R-1-S 12 VDC (S)
Rated coil voltage
1
G2R-
@
-S (S)
Accessories (Order Separately)
Connecting Sockets
Track/surface-mounting Socket
Back-mounting Socket
Push-In Plus
Applicable Relay model
No. of poles
Screw terminals *
Models
PCB terminals
Models
Solder terminals
Model
Terminal Blocks
Model
P2RFZ-05-E
P2RF-05
P2RF-05-E
P2R-05P
P2R-057P
1 pole
G2R-1-S (S)
G2R-2-S (S)
P2RF-05-PU
P2R-05A
P2RFZ-08-E
P2RF-08
P2RF-08-E
P2R-08P
P2R-087P
2 poles
P2RF-08-PU
P2R-08A
*
T
he structure of P2RF-
@
-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals.
Accessories for Push-In Plus Terminal Block Sockets (P2RF-
@
-PU)
Short Bars
Pitch
No. of poles
Colors
Model
*
PYDN-7.75-020
@
PYDN-7.75-030
@
PYDN-7.75-040
@
PYDN-7.75-200
@
PYDN-15.5-080
@
Minimum order (quantity)
2
3
Red (R)
Blue (S)
Yellow (Y)
7.75 mm
4
10
20
8
15.5 mm
Note:
Use the Short Bars for crossover wiring within one Socket or between Sockets.
* Replace
the box (
@
) in the model number with the code for the covering color.
Labels
Minimum order (sheet)
Model
(quantity per sheet)
5
XW5Z-P4.0LB1
1 sheet (60 pieces)
Accessories for Screw Terminal Sockets (P2RFZ-
@
-E)
Short Bars
Pitch
No. of poles
Colors
Model
Minimum order (set)
6.8 mm
10
P2DN-6.8-100S
1
Blue (S)
One set (order unit) contains
10 short bars and 20 caps.
15.7 mm
10
P2DN-15.7-100S
Note: 1.
Use the Short Bars for crossover wiring within one Socket or between Sockets.
2.
Cannot be used on the P2RF-
@
-E.
Labels
Minimum order (sheet)
Model
(quantity per sheet)
5
XW5Z-P2.5LB1
1 sheet (72 pieces)
Accessories for Short Bars (P2DN)
Cap
Model
P2DN-CP100
Minimum order (bag)
1
(100 pcs./bag)
Mounting Tracks
Minimum order
(quantity)
Applicable Socket
Description
Model
50 cm (
l
) × 7.3 mm (t):
PFP-50N
1 m (
l
) × 7.3 mm (t):
PFP-100N
1 m (
l
) × 16 mm (t):
—
Mounting track
Track-connecting Socket
PFP-100N2
PFP-M
End plate *1
Spacer
10
1
PFP-S
Back-connecting Socket
Mounting plate *2
*1
.
W
hen mounting DIN rail, please use End Plate (PFP-M).
*2
.
U
sed to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
P2R-P
2
G2R-
@
-S (S)
Specifications
Coil Ratings
Must
operate
voltage
Must
release
voltage
Coil inductance (H)
(ref. value)
Max.
voltage
Rated current*
Power
consumption
(approx.)
Coil
resistance
Rated voltage
Armature Armature
50 Hz
60 Hz
% of rated voltage
OFF
ON
24 V
48 V
110 V
43.5 mA
21.8 mA
9.5 mA
8.6 mA
4.4 mA
4.2 mA
37.4 mA
18.8 mA
8.2 mA
7.5 mA
3.8 mA
3.7 mA
253
Ω
0.81
1.55
1,040
Ω
5,566
Ω
7,286
Ω
27,172
Ω
27,800
Ω
3.12
6.17
13.33
16.13
72.68
90.58
26.83
32.46
143.90
182.34
AC
80% max.
30% max.
110%
0.9 VA at 60 Hz
120 V
230 V
240 V
Must
operate
voltage
Must
release
voltage
Coil inductance (H)
(ref. value)
Max.
voltage
Power
consumption
(approx.)
Coil
resistance
Rated voltage
Rated current*
Armature Armature
% of rated voltage
OFF
ON
6 V
87.0 mA
43.2 mA
21.6 mA
11.4 mA
69
Ω
0.25
0.48
12 V
278
Ω
0.98
3.60
15.2
2.35
8.25
29.82
DC
70% max.
15% min.
110%
0.53 W
24 V
48 V
1,113
Ω
4,220
Ω
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for the AC rated current
and ±10% for the DC coil resistance.
2.
The AC coil resistance and inductance values are reference values only (at 60 Hz).
3.
Operating characteristics were measured at a coil temperature of 23°C.
4.
The maximum voltage is the maximum possible value of the voltage that can be applied to the relay coil.
It is not the maximum voltage that can be applied continuously.
Contact Ratings
Number of poles
1 pole
2 poles
Resistive load
(cos
φ
= 1)
Inductive load
(cos
φ
= 0.4; L/R = 7 ms)
Resistive load
(cos
φ
= 1)
Inductive load
(cos
φ
= 0.4; L/R = 7 ms)
Load
10 A at 250 VAC;
10 A at 30 VDC
7.5 A at 250 VAC;
5 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 3 A at
30 VDC
Rated load
Rated carry current
10 A
5 A
Max. switching voltage
Max. switching current
440 VAC, 125 VDC
10 A
380 VAC, 125 VDC
5 A
2,500 VA,
300 W
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
Max. switching power
Failure rate (reference value) *
100 mA at 5 VDC
Note:
P level:
λ
60
= 0.1 x 10
-6
/operation
10 mA at 5 VDC
*
T
his value was measured at a switching frequency of 120 operations per minute.
3
G2R-
@
-S (S)
Characteristics
Item
1 pole
2 poles
Contact configration
Contact structure
Contact resistance
Operate (set) time
SPDT
Single
100 m
Ω
max.
15 ms max.
AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
Release (reset) time
Max. operating
frequency
Mechanical:
Electrical:
18,000 operations/hr
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
Ω
min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
5,000 VAC, 50/60 Hz for 1 min between coil and contacts;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
contacts;
Dielectric strength *
1,000 VAC, 50/60 Hz for 1 min between contacts of
same polarity
Destruction:
Malfunction:
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Vibration resistance
Shock resistance
Destruction:
Malfunction:
1,000 m/s
2
200 m/s
2
when energized; 100 m/s
2
when not energized
Mechanical:
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load)
Endurance
Electrical:
Ambient temperature
Operating:
–40
°
C to 70
°
C (with no icing or condensation)
Ambient humidity
Weight
Operating:
5% to 85%
Approx. 20 g
Note:
Values in the above table are the initial values.
*
T
hese values are relay only. Prease refer to the “Products Related to Common Sockets and DIN Tracks Data Sheet” for connecting sockets.
Approved Standards
UL 508 (File No. E41643)
IEC/VDE (Certificate No. 40015012 EN 61810-1)
Contact
form
Opera-
tions
Contact
form
Model
Coil ratings
Contact ratings
Coil ratings
Contact ratings
Operations
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 440 VAC (cos
φ
= 1.0)
10 A, 250 VAC (cos
φ
= 1.0)
10 A, 30 VDC (0 ms)
100 × 10
3
25 × 10
3
100 × 10
3
25 × 10
3
1 pole
100 × 10
3
G2R-1-S (S)
SPDT
G2R-2-S (S)
DPDT
TV-3 (NO contact only)
5 to 110 VDC
6 to 240 VAC
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
5 A, 250 VAC (cos
φ
=1.0)
5 A, 30 VDC (0 ms)
2 poles
100 × 10
3
TV-3 (NO contact only)
LR
Number
CSA 22.2 No.0, No.14
(File No. LR31928)
Coil ratings
Contact ratings
Operations
of poles
Contact
form
Opera-
tions
10 A, 250 VAC (general use)
Model
Coil ratings
Contact ratings
5 to 110 VDC
7.5 A, 250 VAC (PF0.4)
6 to 240 VDC
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
1 pole
100 × 10
3
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
100 × 10
3
25 × 10
3
100 × 10
3
25 × 10
3
G2R-1-S (S)
SPDT
G2R-2-S (S)
DPDT
5 A, 250 VAC (general use)
5 to 110 VDC
2 A, 250 VAC (PF0.4)
6 to 240 VDC
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
TV-3 (NO contact only)
5 to 110 VDC
6 to 240 VAC
2 poles
100 × 10
3
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
4
G2R-
@
-S (S)
Engineering Data
Maximum Switching Power
G2R-2-S (S)
G2R-1-S (S)
100
10
1
100
AC inductive load
AC resistive
load
(cos
φ
= 0.4)
AC inductive load
AC resistive
load
(cos
φ
= 0.4)
10
1
DC resistive
load
DC resistive
load
DC inductive load
(L/R = 7 ms)
DC inductive load
(L/R = 7 ms)
0.1
0.1
1
10
100
1000
1
10
100
1000
Switching voltage (V)
Switching voltage (V)
Endurance
G2R-1-S (S)
G2R-2-S (S)
10,000
5,000
5,000
250-VAC/30-VDC
resistive load
1,000
500
1,000
500
250-VAC inductive load
(cos
φ
= 0.4)
30-VDC inductive load (L/R = 7ms)
250-VAC/30-VDC
resistive load
100
100
50
30-VDC inductive load (L/R = 7ms)
250-VAC
inductive load
(cos
φ
= 0.4)
50
Switching current (A)
Switching current (A)
Ambient Temperature vs Maximum Coil Voltage
DC coil
AC coil
Ambient temperature (
°
C)
5
G2R-
@
-S (S)
Dimensions
(Unit: mm)
Note:
All units are in millimeters unless otherwise indicated.
SPDT Relays
G2R-1-S (S), G2R-1-SN (S), G2R-1-SNI (S)
G2R-1-SD (S), G2R-1-SND (S), G2R-1-SNDI (S)
Terminal Arrangement/Internal Connections
(Bottom View)
G2R-1-SD (S) (DC)
G2R-1-S (S)
1
1
5
29 max.
13 max.
2
4
3
5
2
4
3
G2R-1-SN (S), G2R-1-SNI (S) (AC)
G2R-1-SN (S), G2R-1-SNI (S) (DC)
1
5
1
5
DC24V
0.5
4.75
2
4
3
2
4
3
G2R-1-SND (S), G2R-1-SNDI (S) (DC)
5.2
5.2
17.5
1
2
4
3
5
DPDT Relays
G2R-2-S (S), G2R-2-SN (S), G2R-2-SNI (S)
G2R-2-SD (S), G2R-2-SND (S), G2R-2-SNDI (S)
Terminal Arrangement/Internal Connections
(Bottom View)
G2R-2-S (S)
G2R-2-SD (S) (DC)
1
2
7
3
6
4
5
1
8
2
7
3
6
4
5
13 max.
29 max.
8
G2R-2-SN (S), G2R-2-SNI (S) (AC)
G2R-2-SN (S), G2R-2-SNI (S) (DC)
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
5
0.5
2.5
2.4
G2R-2-SND (S), G2R-2-SNDI (S) (DC)
5
5
19.4
1
8
2
7
3
6
4
5
6
G2R-
@
-S (S)
Track/Surface Mounting Sockets
P2RF-05-PU
57.5
53.1
Terminal Arrangement/
Internal Connection Diagram
(Top View)
Mounting Hole
Dimensions
A2 A1
30.8
28.1
(1)
(5)
(4.2)
25.6
T
w
o M3 screw
holes or
two 3.5-dia. holes
108
Release lever
90
35.3
12
(2)
14
(3)
27.35
11
(4)
Note:
Pull out the hooks to
mount the Socket
with screws.
(4.2)
3.9
Note:
The numbers in
parentheses are
25.6
15.5
34.3
43
52.1
traditionally used
terminal numbers.
P2RF-08-PU
57.5
Terminal Arrangement/
Internal Connection Diagram
(Top View)
53.1
30.8
28.1
Mounting Hole
Dimensions
A2
(1)
A1
(8)
(4.2)
25.6
T
w
o M3 screw
holes or
two 3.5-dia. holes
Release lever
90
108
35.3
12
(2)
22
(7)
27.35
14
(4)
24
(5)
11
(3)
21
(6)
(4.2)
3.9
Note:
Pull out the hooks to
mount the Socket
with screws.
25.6
15.5
34.3
43
52.1
Note:
The numbers in
parentheses are
traditionally used
terminal numbers.
Accessories for P2RF-
@
-PU
Short Bars
No. of
poles
Maximum
carry current
Application
Pitch
L (Length)
Colors
Model
*
PYDN-7.75-
@@
(7.75 mm)
2
3
15.1
22.85
30.6
PYDN-7.75-020
@
PYDN-7.75-030
@
PYDN-7.75-040
@
PYDN-7.75-200
@
For Contact
terminals
(common)
3.90
L
7.75 mm
15.5 mm
Red (R)
Blue (S)
Yellow (Y)
4
20 A
20
154.6
18.5
12
For Coil
terminals
8
115.85
PYDN-15.5-080
@
2.25
1.57
*
R
eplace the box (
@
) in the model number with the code for the covering color.
Note: 1.
Use the Short Bars for crossover wiring within one Socket or between Sockets.
2.
When using short bar to coil terminals of PYF-
@@
-PU, make sure to use PYDN-31.0-
080
@
(31 mm).
PYDN-15.5-080
@
(15.5 mm)
3.90
115.85
When using short bar to coil terminals of P2RF-
@@
-PU, make sure to use PYDN-15.5-
080
@
(15.5 mm).
18.5
12
1.57
2.25
7
G2R-
@
-S (S)
P2RFZ-05-E
Terminal Arrangement/
Internal Connection Diagram
(Top View)
Mounting Hole
Dimensions
2
48 max.
5-M3X8
3.2-dia.
hole
4
ꢀ±.5
(42.3)
(35.8)
2
39.5
3
78.5 max.
39.5±±.ꢀ
3.5-dia.
hole
35.5
M3 or
3.5-dia.
hole
ꢀ7.2
4
5
1
3ꢀ max.
6ꢀ max.
ꢀ6 max.
P2RFZ-08-E
Mounting Hole
Dimensions
Terminal Arrangement/
Internal Connection Diagram
(Top View)
8-M3X8
2
48 max.
2
3.2-dia. hole
ꢀ±.5
6
3
(42.3)
39.5
7
5
2
4
39.5±±.ꢀ
78.5 max.
(35.8)
3.5-dia.
hole
35.5
M3 or
3.5-dia.
hole
ꢀ7.2
8
1
4
3ꢀ max.
6ꢀ max.
ꢀ6 max.
Accessories for P2RFZ-
@
-E
Short Bars
P2DN-6.8-100S (6.8 mm)
Maximum carry current: 20A
ꢀ5.7±±.ꢀ
6.8±±.ꢀ
2.9
9
ꢀ5.4 max.
2.5 max.
8.7 max.
ꢀ52.7 max.
P2DN-15.7-100S (15.7 mm)
Maximum carry current: 20A
ꢀ5.7±±.ꢀ
2.9
9
ꢀ.6-dia.
ꢀ5.4 max.
2.5 max.
8.7 max.
ꢀ52.7 max.
Note:
Each Short Bar set comes with 20 Caps.
Accessories for P2DN
Cap
P2DN-CP100
5.2 max.
4 max.
6 max.
8
G2R-
@
-S (S)
P2RF-05-E
7
0.2
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
2
Five, M3.5´7
48 max.
3.2-dia.
hole
(11)
4
2
(12)
3
39.5
(14)
35.5
39.5 0.1
85.5 max.
3.5-dia.
hole
M3 or
3.5-dia.
hole
5
(A1)
(A2)
1
4
11.5
61 max.
16.0 max.
Note:
Pin numbers in parentheses apply to DIN standard.
P2RF-08-E
+0.2
6
−
0.1
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
2
1.5
Eight, M3´8
2
48.0 max.
3
(11)
(12)
(14)
(21)
(22)
(24)
6
3
2
4
3.2-dia.
hole
7
5
39.5
35.5
85.5
max.
39.5 0.1
8
3.5-dia. hole
M3 or
3.5-dia.
hole
(A1)
1
(A2)
4
11.5
61.0
max.
16.0 max.
2
P2RF-05
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
7
Five, M3.5 x 8
4-dia. holes
4.2-dia. hole
35.5
71.5 max.
30 0.05
19.5
30 max.
4
M3 or 3.2-dia.
hole
19.5 max.
54 max.
P2RF-08
2
7
Terminal Arrangement
Mounting Holes
Eight, M3.5 x 8
4-dia. holes
(Top View)
(for Surface Mounting)
4.2-dia. hole
35.5
71.5 max.
30 0.05
19.5
4
30 max.
19.5 max.
M3 or 3.2-dia.
hole
54 max.
9
G2R-
@
-S (S)
Mounting Height of Relay with Track/Surface Mounting Sockets
P2RF-05-PU
P2RF-08-PU
G2R-
@
-S (S)
G2R-
@
-S (S)
Relay
Relay
P2RF-05
ー
PU
P2RF-08
ー
PU
Socket
Socket
63.6
63.6
28.1
28.1
(3.9)
(3.9)
P2RFZ-E
G2R-
@
-S (S)
Relay
P2RFZ-
@
-E
Socket
67.0
70.5
P2RF-
@
P2RF-
@
-E
G2R-
@
-S (S)
Relay
G2R-
@
-S (S)
Relay
P2RF-
@
-E
Socket
P2RF-
@
Socket
67.0
62.0
66.5
70.5
10
G2R-
@
-S (S)
Back-connecting Sockets
Terminal Arrangement
(Bottom View)
Mounting Holes
T
o
lerance: 0.1
P2R-05P (1-pole)
14.5 max.
4
7
1
4
Five,
6
1.6-dia.
holes
4.5
6
35.5 max.
15
4.5
15
1.2
4
3.5
1.5
4
(5)
4
7
7
36.5 max.
P2R-08P (2-pole)
Terminal Arrangement
(Bottom View)
Mounting Holes
14.5 max.
4
7
0.3
Eight, 1.3-dia. holes
7.5
5
5
5
5
35.5 max.
20
1
2.8
20
1.5
7.5
(4.3)
T
e
rminal plate thickness: 0.3
36.5 max.
4.5
7.5
P2R-05A (1-pole)
14.5 max.
1.2
0.3
Terminal Arrangement
(Bottom View)
6.7
3.8
35.5 max.
5
16.7
Panel Cutout
Five, 3 x 1.8-dia. holes
6
13.6 0.1
36.5 max.
1.2
T
e
rminal plate thickness: 0.3
30.5 0.2
6.5 7.5
14.5 max.
P2R-08A (2-pole)
0.3
2.6
5
5
35.5 max.
Recommended thickness of
the panel is 1.6 to 2.0 mm
20
2.8
1.5
Eight, 3 x 1.2-dia. holes
7.5
T
e
rminal plate thickness: 0.3
36.5 max.
11
G2R-
@
-S (S)
P2R-057P (1-pole)
Mounting Holes
16.4
10.4 3.5
Terminal Arrangement
(Bottom View)
14 max.
8.7
1
0.7
Five,
1.6-dia.
holes
4 0.1
1
1
6
4.5
6 0.1
29.6
15
37 max.
4
8.75
4.5 0.1
15 0.1
4 0.1
5
8.7
7.4
7 0.1
41 max.
16.4
14 max.
7.5
Mounting Holes
P2R-087P (2-pole)
Terminal Arrangement
(Bottom View)
10.4
3.5
1
Eight,
1.3-dia.
holes
0.3
1
7.5
5
5
29.1
37 max.
20
5
5
8.1
20
8.9
7.4
(8.1)
41 max.
Mounting Height of Relay with Back-connecting Sockets
P2R-
@
P
P2R-
@
A
P2R-
@
7P
G2R-
@
-S (S) Relay
G2R-
@
-S (S) Relay
G2R-
@
-S (S) Relay
44.5
47.5
38.0
P2R-
@
P
P2R-
@
A
Socket
P2R-
@
7P
Socket
Socket
Mounting Tracks
PFP-100N, PFP-50N
PFP-100N2
16
7.3 0.15
35 0.3
15 (5)
4.5
4.5
27
29.2
1.5
24
27 0.15
1
35 0.3
15
25
25
15 25
25
25
15 25
25
25
1
10
10
10
10
1,000
1,000 (500)
It is recommended to use a panel 1.6 to 2.0 mm thick.
12
G2R-
@
-S (S)
End Plate
Spacer
16
12
10
6.2
PFP-M
PFP-S
5
1.8
1
35.5 35.3
50
34.8
44.3
1.8
11.5
1.3
4.8
10
M4 x 8 pan
head screw
16.5
Mounting Plate
P2R-P
90
4.5
13.6
R2.25
10-
Ellipse hole
3.4
0.1
42
49
30.5
0.15
0.15
0.15
0.15
18
18
18
18
Square hole
0.1
0.1
9
9
0.2
t=1.6 mm
72
13
G2R-
@
-S (S)
Safety Precautions
Be sure to read the
Common Precautions for All Relay
in the website at the following URL:
Refer to
Products Related to Common Sockets and DIN Tracks
for precautions on the applicable Sockets.
Refer to
PYF-
@@
-PU/P2RF-
@@
-PU
for precautions on Push-In Plus Terminal Block Sockets.
•
When cutting with a tool, insert the tool from the plastic part and cut
along the slot in the plastic part between terminals. If you cut a part
Warning Indications
Indicates a potentially hazardous
situation which, if not avoided, may result
in minor or moderate injury or in property
damage.
other than the slot in the plastic part between terminals, it may not
be possible to attach the insulating cap.
CAUTION
Supplementary comments on what to do
or avoid doing to prevent failure to
operate, malfunction, or undesirable
effects on product performance.
Precautions for
Correct Use
Cation
•
Do not use the test button for any purpose other than testing. Be
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
•
Check that the test button is released before turning ON relay cir-
cuits.
•
When using a cut short-circuit bar (P2DN), always use the provid-
ed cap to protect the charger part.
•
If the test button is pulled out too forcefully, it may bypass the mo-
mentary testing position and go straight into the locked position.
•
Use an insulated tool when you operate the test button.
Precautions for Correct Use
About the Built-in Diodes
•
The proper orientation for installing the short-circuit bar is with the
The diodes that are built into the Relays are designed to absorb
reverse voltage from the Relay’s coil. If a large surge in voltage is
applied to the diode from an external source, the element will be
destroyed.
molded part facing inward.
If there is the possibility of large voltage surges that could be applied
to the elements from an external source, take any necessary surge
absorption measures.
Latching Levers
• Turn
OFF the power supply when operating the latching lever.
After you use the latching lever always return it to its original state.
• Do
not use the latching lever as a switch.
• The
latching lever can be used for 100 operations minimum.
•
Use the short-circuit bar to short-circuit two or more coil terminals,
or two or more contact COM terminals.
•
Do not use a deformed short-circuit bar. Risk of failure, malfunc-
tioning, or deterioration of characteristics.
•
In socket terminals, insert the short-circuit bar in the correct orien-
tation all the way into all terminals, and then secure with screws.
•
Install the short -circuit bar before wiring.
Relay Replacement
To replace the Relay, turn OFF the power supply to the load and
Relay coil sides to prevent unintended operation and possible
electrical shock.
Coil tape color
Pink tape is used for the AC coil type and blue tape is used for the DC
coil type, making it easy to distinguish AC and DC.
Equivalent Labels from Other Companies and
Recommended Label Printers
Using a short-circuit bar
•
Use the short-circuit bar that is suitable for the socket you are using
and the location of use.
•
Note that the P2DN short-circuit bar for the P2RFZ-E Socket has
both a short-circuit bar for shorting coil terminals and a short-circuit
bar for shorting contact COM terminals.
•
The short-circuit bar can be cut to match any number of poles. Cut
with a tool as appropriate for the number of relays and sockets.
When using a cut short-circuit bar, take care to avoid injuring your-
self on the cut surface.
Use the following label printer.
The following table gives the manufacturer’s model number as of
March 2017.
Phoenix
Contact
Manufacturer
Omron
Weidmuller
Cembre
MG-CPM-04
41391
XW5Z-P4.0LB1
UCT-TM6
XW5Z-P2.5LB2
UCT-TMF5
MF 10/6
—
Label
—
BLUEMARK
CLED,
THERMOMA
PrintJet
ADVCANCED,
Plotter MCP
Markingenius
Plus,
Plotter MCP
Basic
Label printer
—
*
RK CARD
MG3
SET PLUS,
THERMOMA
RK CARD
* When
using a printing tool, use a Phoenix Contact label printer.
Note:
Ask the label manufacturer or printer manufacturer for details.
14
OMRON AUTOMATION AMERICAS HEADQUARTERS •
Chicago, IL USA
•
847.843.7900
•
800.556.6766
•
automation.omron.com
OMRON CANADA, INC. • HEAD OFFICE
OMRON ELETRÔNICA DO BRASIL
L
T
DA • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 •
automation.omron.com
São Paulo, S
P
,
B
rasil • 55 11 5171-8920 • automation.omron.com
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
Ciudad de México • 52.55.5901.4300 • 01.800.386.6766 • mela@omron.com
OMRON ARGENTINA • SALES OFFICE
Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
San Pedro Garza García, N.L. • 81.12.53.7392 • 01.800.386.6766 • mela@omron.
com
OTHER OMRON LATIN AMERICA SALES
+54.11.4521.8630 • +54.11.4523.8483 • mela@omron.com
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Eugenio Garza Sada,León, Gto • 01.800.386.6766
• mela@omron.com
Authorized Distributor:
Controllers & I/O
• Machine Automation Controllers (MAC) • Motion Controllers
• Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O
Robotics
• Industrial Robots • Mobile Robots
Operator Interfaces
• Human Machine Interface (HMI)
Motion & Drives
• Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems
• Frequency Inverters
Vision, Measurement & Identification
• Vision Sensors & Systems • Measurement Sensors • Auto Identification
Systems
Sensing
• Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors
• Rotary Encoders • Ultrasonic Sensors
Safety
• Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems
• Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices
• Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays
Control Components
• Power Supplies • Timers • Counters • Programmable Relays
• Digital Panel Meters • Monitoring Products
Switches & Relays
• Limit Switches • Pushbutton Switches • Electromechanical Relays
• Solid State Relays
Software
• Programming & Configuration
• Runtime
J140-E3-02
Note: Specifications are subject to change.
© 2020 Omron. All Rights Reserved.
Printed in U.S.A.
Printed on recycled paper.