Omron-Electronics-G2R-1-SD-DC24-S
| Part # | Omron-Electronics-G2R-1-SD-DC24-S |
| Download | Omron-Electronics-G2R-1-SD-DC24-S |
New G2RS Series
The G2RS Space-saving
Power Plug-in Relay has a mechanical
indicator and nameplate as standard features.
A relay with a lockable test button is also available.
Details on the New G2RS
Nameplate
LED indicator
Overview
Mechanical indicator
Test button
DC: Blue
AC: Red
New Features
• Nameplate and mechanical
indicator provided as a
standard.
• Models with two-way-action
test button available.
• Environment-friendly
construction.
Two-way-action test button
Relay
in
operation
For
momentary
testing
For
lock
testing
Pull down the test button to the
first stop position, then press the
yellow button with an insulated
tool to operate the contact.
Pull down the test button to the
second stop position. (The
contact is now in the locked
position.)
General-purpose Relay
G2RS
Slim and Space-saving Power Plug-in
Relay
• Lockable test button models now available.
• Built-in mechanical operation indicator.
• Provided with nameplate.
• AC type is equipped with a coil-disconnection self-
diagnostic function (LED type).
• High switching power (1-pole: 10 A).
• Environment-friendly (Cd, Pb free).
• Wide range of Sockets also available.
LR
Model Number Structure
■
Model Number Legend
G2R
–
–
–
1
2
3
4
5
6
7
1. Relay
Function
5. Terminals
Blank:General-purpose
S:
Plug-in
2. Number
of Poles
6. Classification
Blank:General-purpose
1:
2:
1 pole
2 poles
N:
D:
LED indicator
Diode
3. Contact
Form
Blank:SPDT
4. Contact
Type
Blank:Single
ND: LED
indicator and diode
NI: LED
indicator with test button
NDI: LED
indicator and diode with test button
7. Rated
Coil Voltage
Ordering Information
■
List of Models
Classification
Enclosure
rating
Coil ratings
AC/DC
Contact form/Model
SPDT
G2R-1-S
DPDT
Plug-in terminal
General-purpose
Unsealed
G2R-2-S
LED indicator
G2R-1-SN
G2R-1-SNI
G2R-1-SD
G2R-1-SND
G2R-1-SNDI
G2R-2-SN
G2R-2-SNI
G2R-2-SD
G2R-2-SND
G2R-2-SNDI
LED indicator with test button
Diode
DC
LED indicator and diode
LED indicator and diode with test button
Note:
When ordering, add the rated coil voltage and “(S)” to the model number. Rated coil voltages are given in the coil ratings table.
New model
Example: G2R-1-S
DC12 (S)
Rated coil voltage
General-purpose Relay
G2RS
1
■
Accessories (Order Separately)
Connecting Sockets
Applicable Relay model
Track/surface-mounting Socket
Back-mounting Socket
Terminals Model
PCB terminals
Screwless clamp terminal
Screw terminal
• P2RF-05-E
1 pole
• P2RF-05S
(See note.)
P2R-05
P
,
P
2R-057P
P2R-05A
+
G2R-1-S(N)(D)(ND)(NI)(NDI)
• P2RF-05
Solder terminals
(P2CM-S
(option))
2 poles
G2R-2-S(N)(D)(ND)(NI)(NDI)
• P2RF-08S
(See note.)
• P2RF-08-E
• P2RF-08
PCB terminals
P2R-08
P
,
P
2R-087P
P2R-08A
+
Solder terminals
(P2CM-S
(option))
Note:
Use of the P2CM Clip & Release Lever is recommended to ensure stable mounting.
Accessories for Screwless Clamp Terminal Socket (Option)
Name
Model
Clip & Release Lever
Nameplate
P2CM-S
R99-11 Nameplate for MY
P2RM-SR (for AC), P2RM-SB (for DC)
Socket Bridge
Mounting Tracks
Applicable Socket
Description
Model
Mounting track and accessories
Mounting track
50 cm (
l
) x 7.3 mm (t)
PFP-50N
1 m (
l
) x 7.3 mm (t)
1 m (
l
) x 16 mm (t)
PFP-100N
PFP-100N2
End plate
Spacer
PFP-M
PFP-S
P2R-P*
Mounting plate
Back-connecting Sockets
*Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
Specifications
■
Coil Ratings
Rated voltage
Rated current*
Coil
resistance*
Coil inductance (H)
(ref. value)
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consumption
(approx.)
50 Hz
60 Hz
Armature Armature
% of rated voltage
OFF
ON
AC 24
V
110 V
43.5 mA
9.5 mA
8.6 mA
4.4 mA
3.7 mA
37.4 mA
8.2 mA
7.5 mA
3.8 mA
3.2 mA
253
Ω
0.81
1.55
80% max.
30% min.
110%
0.9 VA at 60 Hz
5,566
Ω
7,286
Ω
27,172
Ω
30,360
Ω
13.33
16.13
72.68
90.58
26.83
120 V
32.46
230 V
143.90
182.34
240 V
Rated voltage
Rated current*
Coil
resistance*
Coil inductance (H)
(ref. value)
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consumption
(approx.)
Armature Armature
% of rated voltage
OFF
0.25
ON
DC 6
V
12 V
87.0 mA
69
Ω
0.48
2.35
8.25
70% max.
15% min.
110%
0.53 W
43.2 mA
21.6 mA
11.4 mA
278
Ω
0.98
3.60
15.2
24 V
1,113
Ω
4,220
Ω
48 V
29.82
*
The rated current and coil resistance are measured at a coil temperature of 23
°
C with tolerances of
±
10%.
2
General-purpose Relay
G2RS
■
Contact Ratings
Number of poles
1 pole
2 poles
Load
Resistive load
(cos
φ
= 1)
Inductive load
(cos
φ
= 0.4; L/R = 7 ms)
Resistive load
(cos
φ
= 1)
Inductive load
(cos
φ
= 0.4; L/R = 7 ms)
Rated load
10 A at 250 VAC;
10 A at 30 VDC
7.5 A at 250 VAC;
5 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 3 A at
30 VDC
Rated carry current
10 A
5 A
Max. switching voltage
Max. switching current
Max. switching capacity
440 VAC, 125 VDC
10 A
380 VAC, 125 VDC
5 A
2,500 VA,
300 W
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
Minimum permissible load
100 mA at 5 VDC
10 mA at 5 VDC
Note:
P level:
λ
60
= 0.1 x 10
-6
/operation
■
Characteristics
Item
1 pole
2 poles
Contact resistance
Operate (set) time
Release (reset) time
100 m
Ω
max.
15 ms max.
AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
Max. operating
frequency
Mechanical:
Electrical:
18,000 operations/hr
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
Ω
min. (at 500 VDC)
Dielectric strength
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
same polarity
Vibration resistance
Shock resistance
Destruction: 10
to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10
to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction: 1,000
m/s
2
Malfunction: 200
m/s
2
when energized; 100 m/s
2
when not energized
Service life
Mechanical:
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)
Electrical:
Ambient temperature
Operating:
–40
°
C to 70
°
C (with no icing or condensation)
Ambient humidity
Weight
Operating:
5% to 85%
Approx. 21 g
Note:
Values in the above table are the initial values.
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is used.
■
Approved Standards
UL 508 (File No. E41643)
IEC/VDE (EN61810)
Model
Contact Coil
ratings
form
Contact ratings
Opera-
tions
Contact
form
Coil ratings
Contact ratings
Operations
6 x 10
3
100 x 10
3
G2R-1-S SPDT
G2R-2-S DPDT
5 to 110 VDC
10 A, 30 VDC (resistive)
5 to 240 VAC
10 A, 250 VAC (general use)
TV-3 (NO contact only)
1 pole
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 440 VAC (cos
φ
= 1.0)
10 A, 250 VAC (cos
φ
= 1.0)
10 A, 30 VDC (0 ms)
6 x 10
3
100 x 10
3
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
2 poles
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 250 VAC (cos
φ
=1.0)
5 A, 30 VDC (0 ms)
CSA 22.2 No.0, No.14
(File No. LR31928)
LR
Number of
Coil ratings
poles
Contact ratings
Operations
Model
Contact Coil
ratings
form
Contact ratings
Opera-
tions
6 x 10
3
100 x 10
3
1 pole
5 to 110 VDC
10 A, 250 VAC (general use)
5 to 240 VDC
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
G2R-1-S SPDT
G2R-2-S DPDT
5 to 110 VDC
10 A, 30 VDC (resistive)
5 to 240 VAC
10 A, 250 VAC (general use)
TV-3 (NO contact only)
5A, 30VDC (L/R=7ms)
100 x 10
3
2 poles
5 to 110 VDC
5 A, 250 VAC (general use)
5 to 240 VDC
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
6 x 10
3
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
3A, 30VDC (L/R=7ms)
General-purpose Relay
G2RS
3
Engineering Data
■
Maximum Switching Capacity
Plug-in Relays
G2R-1-S
G2R-2-S
100
100
AC inductive load
(cos
φ
= 0.4)
AC resistive
load
AC inductive load
(cos
φ
= 0.4)
AC resistive
load
10
10
1
DC resistive
load
DC resistive
load
DC inductive load
(L/R = 7 ms)
1
DC inductive load
(L/R = 7 ms)
0.1
0.1
1
10
100
1000
1
10
100
1000
Switching voltage (V)
Switching voltage (V)
■
Electrical Service Life
Plug-in Relays
G2R-1-S
G2R-2-S
10,000
5,000
5,000
250-VAC/30-VDC
1,000
500
resistive load
1,000
500
250-VAC inductive load
(cos
φ
= 0.4)
30-VDC inductive load (L/R = 7ms)
250-VAC/30-VDC
resistive load
100
50
100
50
30-VDC inductive load (L/R = 7ms)
250-VAC
inductive load
(cos
φ
= 0.4)
Switching current (A)
Switching current (A)
Ambient Temperature vs. Maximum Coil Voltage
DC coil
AC coil
Note:
The maximum voltage refers to the maximum
value in a varying range of operating power
voltage, not a continuous voltage.
Ambient temperature (
°
C)
4
General-purpose Relay
G2RS
Dimensions
Unit: mm (inch)
■
Relays with Plug-in Terminals
SPDT Relays
Terminal Arrangement/Internal Connections
(Bottom View)
G2R-1-S, G2R-1-SN, G2R-1-SNI
G2R-1-SD, G2R-1-SND, G2R-1-SNDI
G2R-1-SD (DC)
G2R-1-S
1
5
1
5
13 max.
(0.51)
29 (1.14) max.
2
4
3
2
4
3
35.5 max.
(1.40)
G2R-1-SN, G2R-1-SNI (DC)
G2R-1-SN, G2R-1-SNI (AC)
20
(0.79)
1
1
D
C
24V
5 (0.20)
1(0.04)
4.75
(0.19)
0.5
(0.02)
2
4
3
2
4
3
5
5
7.5 (0.29)
G2R-1-SND, G2R-1-SNDI (DC)
5.2
5.2
(0.20)
(0.20)
17.5
1
(0.69)
2
4
3
5
DPDT Relays
G2R-2-S, G2R-2-SN, G2R-2-SNI
G2R-2-SD, G2R-2-SND, G2R-2-SNDI
Terminal Arrangement/Internal Connections
(Bottom View)
G2R-2-S
G2R-2-SD (DC)
1
2
7
3
6
4
5
1
2
7
3
4
29 max.
(1.14)
13 max.
(0.51)
8
8
6
5
35.5 max.
(1.40)
G2R-2-SN, G2R-2-SNI (AC)
G2R-2-SN, G2R-2-SNI (DC)
20
(0.79)
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
5
6.2
(0.29)
2.5
(0.10)
0.5
(0.02)
2.4
(0.09)
7.4
8.9
(0.29)
(0.35)
G2R-2-SND, G2R-2-SNDI (DC)
5 (0.02)
5 (0.02)
1
8
2
7
3
6
4
5
19.4
(0.76)
General-purpose Relay
G2RS
5
Track/Surface Mounting Sockets
P2RF-05-S
T
e
rminal Arrangement
(
T
o
p View)
38.2 max. (1.50)
36.5 max. (1.44)
11
14
12
32.6 (1.28)
27.6 (1.09)
22.6
(0.89)
24.5
(0.96)
35.4
(1.39)
92.0 max.
(3.62)
A1 A2
Option (with ejector and
Standard model
label attached)
28.5 (1.12)
5.3 typical
(0.21)
18.0 max.
(0.71)
32.6
(1.28)
T
e
rminal Arrangement
(
T
o
p View)
38.2 max. (1.50)
P2RF-08-S
36.5 max.(1.44)
21 11
24 14
22 12
32.6 (1.28)
27.6 (1.09)
22.6
(0.89)
3.4 (0.13) typical
24.5
(0.96)
92.0 max.
(3.62)
35.4
(1.39)
A1 A2
Option (with ejector
and label attached)
Standard model
28.6 (1.12)
32.6 (1.28)
5.3 typical
(0.21)
18.0 max.
(0.71)
Accessories for P2RF-
@
-S
Socket Bridge
Clip and Release Lever
16.8
(0.66)
40.35
(1.59)
Note:
The color of insulating coating indicates power type.
36
(1.42)
Model
P2RM-SR
P2RM-SB
Power
Color
AC
DC
Red
Blue
6
General-purpose Relay
G2RS
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
P2RF-05-E
2 (0.08)
Five, M3.5
×
7
48 max.
(1.89)
3.2 (0.13)
dia. hole
(11)
4
39.5
(1.55)
35.5
(1.40)
2
(14)
3
(12)
39.5 0.1
(1.55 0.004)
85.5 max.
(3.37)
3.5 (0.14)
dia. hole
5
M3 or 3.5
(0.14) dia.
(A1)
(A2)
1
5
11.5
(0.20)
(0.45)
16.0 max.
(0.63)
61 max.
(2.40)
Note:
Pin numbers in parentheses apply to DIN standard.
P2RF-08-E
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
1.5
(0.06)
2 (0.08)
3 (0.12)
48.0 max.
(1.89)
Eight, M3
×
8
2 (0.08)
(11)
(12)
(14)
(21)
(22)
(24)
6
3
2
4
3.2 (0.13)
dia. hole
7
5
39.5
(1.55)
35.5
(1.40)
85.5 max
(3.37)
39.5 0.1
(1.55 0.004)
8
3.5 (0.14)
dia. hole
(A1)
1
M3 or 3.5 (0.14)
dia. hole
(A2)
11.5 (0.45)
5 (0.20)
61.0 max.
(2.40)
16.0 (0.63) max.
2 (0.08)
7(0.28)
Five, M3.5 x 8
P2RF-05
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
4 (0.16)
dia. holes
4.2 (0.16)
dia. hole
71.5 max.
35.5
(2.81)
(1.40)
30 0.05
(1.18 0.002)
4
19.5 (0.77)
30 max.(1.18)
M3 or 3.2 (0.13)
dia. hole
19.5 max.
(0.77)
(0.16)
54 max.
(2.12)
P2RF-08
2 (0.08)
7 (0.28)
Eight, M3.5 x 8
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
4.2 (0.16) dia. hole
4 (0.16)
dia. holes
71.5 max.
(2.89)
35.5
(1.40)
30 0.05
(1.18 0.002)
19.5 (0.77)
30 max.(1.18)
4 (0.16)
19.5 max.
(0.77)
M3 or 3.2 (0.13)
dia. hole
54 max.
(2.12)
General-purpose Relay
G2RS
7
Mounting Height of Relay with Track/Surface Mounting Sockets
P2RF-
@
-E
P2RF-
@
62.0
(2.44)
66.5
(2.62)
67.0
(2.64)
70.5
(2.77)
P2RF-
@
-S
72.0
(2.83)
65.0
(2.56)
28.6
(1.12)
5.30 (0.21) typical
Back-connecting Sockets
Terminal Arrangement
(Bottom View)
Mounting Holes
14.5 max.
(0.57)
P2R-05P (1-pole)
T
o
lerance: 0.1
4 (0.16)
1(0.04)
7 (0.27)
4 (0.14)
Five, 1.6 (0.06)
dia. holes
6 (0.24)
4.5 (0.18)
15
35.5 max.
(1.40)
6 (0.24)
(0.59)
4.5 (0.18)
15 (0.59)
1.2 (0.05)
4 (0.16)
3.5
(0.14)
4 (0.16)
1.5 (0.06)
5 (0.20) typical
7 (0.27)
4 (0.16)
7 (2.27)
36.5 max.
(1.44)
P2R-08P (2-pole)
14.5 max.
(0.57)
Terminal Arrangement
(Bottom View)
Mounting Holes
4 (0.16)
0.3
7 (0.27)
7.5
(0.29)
Eight, 1.3 (0.05)
dia. holes
(0.01)
5 (0.20)
5 (0.20)
35.5 max.
(1.40)
5 (0.20)
20
(0.79)
1 (0.04)
5 (0.20)
20
(0.79)
2.8 (0.11)
1.5 (0.06)
7.5 (0.29)
4.3 (0.17) typical
T
e
rminal plate thickness: 0.3 (0.01)
36.5 max. (1.44)
8
General-purpose Relay
G2RS
5 (0.20)
0.3
(0.01)
14.5 max.
(0.57)
7 (0.28)
1.2 (0.05)
P2R-05A (1-pole)
Terminal Arrangement
(Bottom View)
6.7 (0.26)
3.8 (0.15)
35.5 max.
(1.40)
16.7
(0.66)
5 (0.20)
Panel Cutout
Five, 3 x 1.8-dia. holes
(0.12 x 0.07)
13.6 0.1
(0.54 0.004)
6 (0.24)
36.5 max.
(1.44)
T
e
rminal plate thickness: 0.3
7 (0.28)
30.5 0.2
(1.20 0.008)
14.5 max.
(0.57)
7 (0.28)
1.2 (0.05)
P2R-08A (2-pole)
0.3
(0.01)
5 (0.20)
5 (0.20)
35.5 max.
(1.40)
20
Recommended thickness of
the panel is 1.6 to 2.0 mm
(0.79)
2.6 (0.10)
2.8(0.11)
1.5 (0.06)
Eight, 3 x 1.2
(0.12 x 0.05)dia. holes
7.5
(0.30)
T
e
rminal plate thickness: 0.3
36.5 max.
(1.44)
P2R-057P
14 max. (0.55)
Terminal Arrangement
(Bottom View)
Mounting Holes
4 0.1
16.4 (0.65)
10.4
0.7 (0.03)
1(0.04)
8.7
(0.16 0.004)
(0.41)
Five, 1.6 (0.06)
dia. holes
6 0.1(0.24 0.004)
(0.34)
29.6
(1.17)
37 max.
(1.46)
4.5 0.1
(0.18 0.004)
15 0.1(0.59 0.004)
7.4 (0.29)
4 0.1
(0.16 0.004)
5 (0.20)
8.7
(0.34)
7 0.1(0.27 0.004)
41 max.
(1.61)
14 max.
(0.55)
Terminal Arrangement
(Bottom View)
Mounting Holes
16.4(0.65)
1 (0.04)
P2R-087P
10.4
7.5
(0.30)
7.5 (0.30)
Eight, 1.3 (0.05)
(0.41)
dia. holes
37 max.
29.1
(1.15)
(1.46)
5 (0.20)
5 (0.20)
20
(0.79)
7.4 (0.29)
8.9 (0.35)
8.1(0.32) typical
41 max.
(1.61)
General-purpose Relay
G2RS
9
Mounting Height of Relay with Back-connecting Sockets
G2R-
@
P
G2R-
@
A
G2R-
@
7P
G2R Relay
G2R Relay
47.5
(1.87)
38.0
(1.50)
44.5
(1.75)
P2R-_A
Socket
P2R-_P
Socket
Mounting Tracks
PFP-100N, PFP-50N
PFP-100N2
16 (0.63)
7.3 0.15
(0.29 0.006)
4.5
4.5 (0.18)
(0.18)
24
(0.94)
27
(1.06)
29.2
(1.15)
35 0.3
(1.38 0.01)
27 0.15
1
35 0.3
15
25
25
10 (0.39)
25
25
10 (0.39)
25
25
15 (0.59)
25 (0.98)
1 (0.04)
1.5 (0.06)
15 (0.59)
25 (0.98)
1,000 (39.37)
or 500 (19.68)
15(0.59)
or 5 (0.20)
10
10
1,000
(39.37)
It is recommended to use a panel 1.6 to 2.0 mm thick.
End Plate
Spacer
16 (0.63)
10 (0.39)
6.2 (0.24)
5 (0.20)
12 (0.47)
PFP-M
PFP-S
1.8 (0.07)
1 (0.04)
35.5
(1.40)
35.3
(1.39)
50
(1.97)
34.8
(1.37)
1.8
(0.07)
44.3
(1.74)
11.5
(0.45)
1.3 (0.05)
4.8 (0.19)
10 (0.39)
M4 x 8 pan
head screw
16.5 (0.65)
Precautions
Precautions for P2RF-
@
-S Connection
•
Do not move the screwdriver up, down, or from side to side while it
is inserted in the hole. Doing so may cause damage to internal
components (e.g., deformation of the clamp spring or cracks in the
housing) or cause deterioration of insulation.
!Caution
Do not use the test button for any purpose other than testing. Be
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
•
Do not insert the screwdriver at an angle. Doing so may break the
side of the socket and result in a short-circuit.
!Caution
Check that the test button is released before turning ON relay cir-
cuits.
!Caution
If the test button is pulled out too forcefully, it may bypass the mo-
mentary testing position and go straight into the locked position.
!Caution
Use an insulated tool when you operate the test button.
10
General-purpose Relay
G2RS
Certain Terms and Conditions of Sale
1. Offer;
Acceptance. These terms and conditions (these “
T
e
rms”) are deemed
12. Warranties.
(a) Exclusive Warrant
y
.
S
eller’s exclusive warranty is that the
part of all catalogs, manuals or other documents, whether electronic or in writ-
ing, relating to the sale of goods or services (collectivel
y
,
t
he “Goods”) by
Omron Electronics LLC and its subsidiary companies (“Seller”).
Seller hereby
objects to any terms or conditions proposed in Buyer’s purchase order or other
documents which are inconsistent with, or in addition to, these
T
e
rms.
Please
contact your Omron representative to confirm any additional terms for sales
from your Omron compan
y
.
Goods will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Seller (or such other period expressed
in writing by Seller).
Seller disclaims all other warranties, express or implied.
(b) Limitations.
SELLER MAKES NO WARRANTY OR REPRESEN
T
A
T
ION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMEN
T
,
M
ERCHAN
T
A
BIL-
ITY OR FITNESS FOR
A
P
A
RTICULAR PURPOSE OF THE GOODS.
BUYER ACKNOWLEDGES TH
A
T
I
T ALONE HAS DETERMINED TH
A
T
T
HE
GOODS WILL SUI
T
A
B
L
Y
M
EET THE REQUIREMENTS OF THEIR
INTENDED USE.
Seller further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Goods or other-
wise of any intellectual property right.
(c) Buyer Remed
y
.
S
eller’s sole obliga-
tion hereunder shall be to replace (in the form originally shipped with Buyer
responsible for labor charges for removal or replacement thereof) the non-
complying Good or, at Seller’s election, to repay or credit Buyer an amount
equal to the purchase price of the Good; provided that in no event shall Seller
be responsible for warrant
y
,
r
epair, indemnity or any other claims or expenses
regarding the Goods unless Seller’s analysis confirms that the Goods were
properly handled, stored, installed and maintained and not subject to contami-
nation, abuse, misuse or inappropriate modification.
Return of any goods by
Buyer must be approved in writing by Seller before shipment.
Seller shall not
be liable for the suitability or unsuitability or the results from the use of Goods
in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments.
Any
advice, recommendations or information given orally or in writing, are not to be
construed as an amendment or addition to the above warrant
y
.
2. Prices. All
prices stated are current, subject to change without notice by
Seller. Buyer
agrees to pay the price in effect at time of shipment.
3. Discounts.
Cash discounts, if an
y
,
w
ill apply only on the net amount of
invoices sent to Buyer after deducting transportation charges, taxes and
duties, and will be allowed only if (i) the invoice is paid according to Seller’s
payment terms and (ii) Buyer has no past due amounts owing to Seller.
4. Orders.
Seller will accept no order less than $200 net billing.
5. Governmental
Approvals. Buyer
shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the impor-
tation or sale of the Goods.
6.
T
a
xes.
All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon,
imposed directly or indirectly on Seller or required to be collected directly or
indirectly by Seller for the manufacture, production, sale, deliver
y
,
i
mportation,
consumption or use of the Goods sold hereunder (including customs duties
and sales, excise, use, turnover and license taxes) shall be charged to and
remitted by Buyer to Seller.
7. Financial.
If the financial position of Buyer at any time becomes unsatisfactory
to Seller, Seller reserves the right to stop shipments or require satisfactory
13. Damage Limits; Etc.
SELLER SHALL NOT BE LIABLE FOR SPECIAL, INDI-
security or payment in advance.
If Buyer fails to make payment or otherwise
comply with these
T
e
rms or any related agreement, Seller may (without liability
and in addition to other remedies) cancel any unshipped portion of Goods sold
hereunder and stop any Goods in transit until Buyer pays all amounts, includ-
ing amounts payable hereunder, whether or not then due, which are owing to it
by Buyer.
Buyer shall in any event remain liable for all unpaid accounts.
8. Cancellation;
Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Seller fully against all costs or expenses arising in
connection therewith.
RECT OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUC-
TION OR COMMERCIAL LOSS IN ANY W
A
Y
C
ONNECTED WITH THE
GOODS, WHETHER SUCH CLAIM IS BASED IN CONTRAC
T
, WARRANT
Y
,
NEGLIGENCE OR STRICT LIABILIT
Y
.
F
urther, in no event shall liability of
Seller exceed the individual price of the Good on which liability is asserted.
14. Indemnities.
Buyer shall indemnify and hold harmless Seller, its affiliates and
its employees from and against all liabilities, losses, claims, costs and
expenses (including attorney’s fees and expenses) related to any claim, inves-
tigation, litigation or proceeding (whether or not Seller is a party) which arises
or is alleged to arise from Buyer’s acts or omissions under these
T
e
rms or in
any way with respect to the Goods.
Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Seller and defend or settle
any action brought against Seller to the extent that it is based on a claim that
any Good made to Buyer specifications infringed intellectual property rights of
another part
y
.
15. Property; Confidentialit
y
.
T
he intellectual property embodied in the Goods is
the exclusive property of Seller and its affiliates and Buyer shall not attempt to
duplicate it in any way without the written permission of Seller.
Notwithstand-
ing any charges to Buyer for engineering or tooling, all engineering and tooling
shall remain the exclusive property of Seller.
All information and materials
supplied by Seller to Buyer relating to the Goods are confidential and propri-
etar
y
,
a
nd Buyer shall limit distribution thereof to its trusted employees and
strictly prevent disclosure to any third part
y
.
16. Miscellaneous.
(a) Waiver.
No failure or delay by Seller in exercising any right
and no course of dealing between Buyer and Seller shall operate as a waiver
of rights by Seller. (b) Assignment.
Buyer may not assign its rights hereunder
without Seller’s written consent.
(c) Amendment.
These
T
e
rms constitute the
entire agreement between Buyer and Seller relating to the Goods, and no pro-
vision may be changed or waived unless in writing signed by the parties.
(d) Severabilit
y
.
I
f any provision hereof is rendered ineffective or invalid, such
provision shall not invalidate any other provision. (e) Setoff.
Buyer shall have
no right to set off any amounts against the amount owing in respect of this
invoice. (f)
As used herein, “including” means “including without limitation”.
9. Force
Majeure. Seller
shall not be liable for any delay or failure in delivery
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machiner
y
,
a
cts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authorit
y
.
10. Shipping; Deliver
y
.
U
nless otherwise expressly agreed in writing by Seller:
a. Shipments shall be by a carrier selected by Seller;
b. Such
carrier shall act as the agent of Buyer and delivery to such carrier
shall constitute delivery to Buyer;
c. All
sales and shipments of Goods shall be FOB shipping point (unless oth-
erwise stated in writing by Seller), at which point title to and all risk of loss of
the Goods shall pass from Seller to Buyer, provided that Seller shall retain a
security interest in the Goods until the full purchase price is paid by Buyer;
d. Delivery and shipping dates are estimates onl
y
.
e. Seller will package Goods as it deems proper for protection against normal
handling and extra charges apply to special conditions.
11. Claims.
Any claim by Buyer against Seller for shortage or damage to the
Goods occurring before delivery to the carrier must be presented in writing to
Seller within 30 days of receipt of shipment and include the original transporta-
tion bill signed by the carrier noting that the carrier received the Goods from
Seller in the condition claimed.
Certain Precautions on Specifications and Use
1. Suitability
of Use.
Seller shall not be responsible for conformity with any stan-
2. Programmable
Products. Seller
shall not be responsible for the user’s pro-
dards, codes or regulations which apply to the combination of the Good in the
gramming of a programmable Good, or any consequence thereof.
Buyer’s application or use of the Good.
At Buyer’s request, Seller will provide
3. Performance
Data. Performance
data given in this catalog is provided as a
applicable third party certification documents identifying ratings and limitations
of use which apply to the Good.
This information by itself is not sufficient for a
complete determination of the suitability of the Good in combination with the
end product, machine, system, or other application or use.
The following are
guide for the user in determining suitability and does not constitute a warrant
y
.
It may represent the result of Seller’s test conditions, and the user must corre-
late it to actual application requirements.
Actual performance is subject to the
Seller’s Warranty and Limitations of Liabilit
y
.
some examples of applications for which particular attention must be given.
4. Change
in Specifications.
Product specifications and accessories may be
This is not intended to be an exhaustive list of all possible uses of this Good,
nor is it intended to imply that the uses listed may be suitable for this Good:
(i) Outdoor
use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Energy
control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government
regulations.
changed at any time based on improvements and other reasons.
It is our prac-
tice to change part numbers when published ratings or features are changed,
or when significant construction changes are made.
However, some specifica-
tions of the Good may be changed without any notice.
When in doubt, special
part numbers may be assigned to fix or establish key specifications for your
application. Please
consult with your Seller’s representative at any time to con-
firm actual specifications of purchased Good.
5. Errors
and Omissions.
The information in this catalog has been carefully
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors, or omissions.
(iii) Systems, machines and equipment that could present a risk to life or
propert
y
.
P
lease know and observe all prohibitions of use applicable to
this Good.
NEVER USE THE PRODUCT FOR AN APPLIC
A
T
ION INVO
L
V
ING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING TH
A
T
T
HE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND TH
A
T
THE SELLER’S PRODUCT IS PROPER
L
Y
R
A
T
ED AND INS
T
A
LLED FOR
THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
General-purpose Relay
G2RS
11
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
OMRON ON-LINE
OMRON ELECTRONICS LLC
55 East Commerce Drive, Suite B
Schaumburg, IL 60173-5302
OMRON CANADA, INC.
885 Milner Avenue
T
o
ronto, Ontario M1B 5V8
847-882-2288
416-286-6465
Cat. No. J140-E3-01
11/03/2.5M
Specifications subject to change without notice
Printed in USA
12
General-purpose Relay
G2RS