Omron-Electronics-G2R-1-SD-DC6-S

Part #Omron-Electronics-G2R-1-SD-DC6-S
Download 
Omron-Electronics-G2R-1-SD-DC6-S
New G2RS Series  
The G2RS Space-saving  
Power Plug-in Relay has a mechanical  
indicator and nameplate as standard features.  
A relay with a lockable test button is also available.  

Details on the New G2RS  
Nameplate  
LED indicator  
Overview  
Mechanical indicator  
Test button  
DC: Blue  
AC: Red  
New Features  
• Nameplate and mechanical  
indicator provided as a  
standard.  
• Models with two-way-action  
test button available.  
• Environment-friendly  
construction.  
Two-way-action test button  
Relay  
in  
operation  
For  
momentary  
testing  
For  
lock  
testing  
Pull down the test button to the  
first stop position, then press the  
yellow button with an insulated  
tool to operate the contact.  
Pull down the test button to the  
second stop position. (The  
contact is now in the locked  
position.)  

General-purpose Relay  
G2RS  
Slim and Space-saving Power Plug-in  
Relay  
• Lockable test button models now available.  
• Built-in mechanical operation indicator.  
• Provided with nameplate.  
• AC type is equipped with a coil-disconnection self-  
diagnostic function (LED type).  
• High switching power (1-pole: 10 A).  
• Environment-friendly (Cd, Pb free).  
• Wide range of Sockets also available.  
LR  
Model Number Structure  
■
Model Number Legend  
G2R  
–
–
–
1
2
3
4
5
6
7
1. Relay
 
Function  
5. Terminals  
Blank:General-purpose  
S:  
Plug-in  
2. Number
 
of Poles  
6. Classification  
Blank:General-purpose  
1:  
2:  
1 pole  
2 poles  
N:  
D:  
LED indicator  
Diode  
3. Contact
 
Form  
Blank:SPDT  
4. Contact
 
Type  
Blank:Single  
ND: LED
 
indicator and diode  
NI: LED
 
indicator with test button  
NDI: LED
 
indicator and diode with test button  
7. Rated
 
Coil Voltage  
Ordering Information  
■
List of Models  
Classification  
Enclosure  
rating  
Coil ratings  
AC/DC  
Contact form/Model  
SPDT  
G2R-1-S  
DPDT  
Plug-in terminal  
General-purpose  
Unsealed  
G2R-2-S  
LED indicator  
G2R-1-SN  
G2R-1-SNI  
G2R-1-SD  
G2R-1-SND  
G2R-1-SNDI  
G2R-2-SN  
G2R-2-SNI  
G2R-2-SD  
G2R-2-SND  
G2R-2-SNDI  
LED indicator with test button  
Diode  
DC  
LED indicator and diode  
LED indicator and diode with test button  
Note:
When ordering, add the rated coil voltage and “(S)” to the model number. Rated coil voltages are given in the coil ratings table.  
New model  
Example: G2R-1-S
 
DC12 (S)  
Rated coil voltage  
General-purpose Relay
G2RS  
1

■
Accessories (Order Separately)  
Connecting Sockets  
Applicable Relay model  
Track/surface-mounting Socket  
Back-mounting Socket  
Terminals Model  
PCB terminals  
Screwless clamp terminal  
Screw terminal  
• P2RF-05-E  
1 pole  
• P2RF-05S
(See note.)  
P2R-05
P
,
P
2R-057P  
P2R-05A  
+
G2R-1-S(N)(D)(ND)(NI)(NDI)  
• P2RF-05  
Solder terminals  
(P2CM-S
(option))  
2 poles  
G2R-2-S(N)(D)(ND)(NI)(NDI)  
• P2RF-08S
(See note.)  
• P2RF-08-E  
• P2RF-08  
PCB terminals  
P2R-08
P
,
P
2R-087P  
P2R-08A  
+
Solder terminals  
(P2CM-S
(option))  
Note:
Use of the P2CM Clip & Release Lever is recommended to ensure stable mounting.  
Accessories for Screwless Clamp Terminal Socket (Option)  
Name  
Model  
Clip & Release Lever  
Nameplate  
P2CM-S  
R99-11 Nameplate for MY  
P2RM-SR (for AC), P2RM-SB (for DC)  
Socket Bridge  
Mounting Tracks  
Applicable Socket  
Description  
Model  
Mounting track and accessories  
Mounting track  
50 cm (
l
) x 7.3 mm (t)
 
PFP-50N  
1 m (
l
) x 7.3 mm (t)  
1 m (
l
) x 16 mm (t)  
PFP-100N  
PFP-100N2  
End plate  
Spacer  
PFP-M  
PFP-S  
P2R-P*  
Mounting plate  
Back-connecting Sockets  
*Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.  
Specifications  
■
Coil Ratings  
Rated voltage  
Rated current*  
Coil  
resistance*  
Coil inductance (H)  
(ref. value)  
Must  
operate  
voltage  
Must  
release  
voltage  
Max.  
voltage  
Power  
consumption  
(approx.)  
50 Hz  
60 Hz  
Armature Armature  
% of rated voltage  
OFF  
ON  
AC 24
 
V  
110 V  
43.5 mA  
9.5 mA  
8.6 mA  
4.4 mA  
3.7 mA  
37.4 mA  
8.2 mA  
7.5 mA  
3.8 mA  
3.2 mA  
253
Ω
 
0.81  
1.55  
80% max.
 
30% min.
 
110%  
0.9 VA at 60 Hz  
5,566
Ω  
7,286
Ω  
27,172
Ω  
30,360
Ω  
13.33  
16.13  
72.68  
90.58  
26.83  
120 V  
32.46  
230 V  
143.90  
182.34  
240 V  
Rated voltage  
Rated current*  
Coil  
resistance*  
Coil inductance (H)  
(ref. value)  
Must  
operate  
voltage  
Must  
release  
voltage  
Max.  
voltage  
Power  
consumption  
(approx.)  
Armature Armature  
% of rated voltage  
OFF  
0.25  
ON  
DC 6
 
V  
12 V  
87.0 mA  
69
Ω  
0.48  
2.35  
8.25  
70% max.
 
15% min.
 
110%  
0.53 W  
43.2 mA  
21.6 mA  
11.4 mA  
278
Ω  
0.98  
3.60  
15.2  
24 V  
1,113
Ω  
4,220
Ω  
48 V  
29.82  
*
The rated current and coil resistance are measured at a coil temperature of 23
°
C with tolerances of
±
10%.  
2
General-purpose Relay
G2RS  

■
Contact Ratings  
Number of poles  
1 pole  
2 poles  
Load  
Resistive load  
(cos
φ
= 1)  
Inductive load  
(cos
φ
= 0.4; L/R = 7 ms)  
Resistive load  
(cos
φ
= 1)  
Inductive load  
(cos
φ
= 0.4; L/R = 7 ms)  
Rated load  
10 A at 250 VAC;  
10 A at 30 VDC  
7.5 A at 250 VAC;  
5 A at 30 VDC  
5 A at 250 VAC;  
5 A at 30 VDC  
2 A at 250 VAC; 3 A at  
30 VDC  
Rated carry current  
10 A  
5 A  
Max. switching voltage  
Max. switching current  
Max. switching capacity  
440 VAC, 125 VDC  
10 A  
380 VAC, 125 VDC  
5 A  
2,500 VA,  
300 W  
1,875 VA,  
150 W  
1,250 VA,  
150 W  
500 VA,  
90 W  
Minimum permissible load  
100 mA at 5 VDC  
10 mA at 5 VDC  
Note:
P level:
λ

60

= 0.1 x 10

-6

/operation  
■
Characteristics  
Item  
1 pole  
2 poles  
Contact resistance  
Operate (set) time  
Release (reset) time  
100 m
Ω
max.  
15 ms max.  
AC: 10 ms max.; DC: 5 ms max.  
(w/built-in diode: 20 ms max.)  
AC: 15 ms max.; DC: 10 ms max.  
(w/built-in diode: 20 ms max.)  
Max. operating  
frequency  
Mechanical:  
Electrical:  
18,000 operations/hr  
1,800 operations/hr (under rated load)  
Insulation resistance
 
1,000 M
Ω
min. (at 500 VDC)  
Dielectric strength  
5,000 VAC, 50/60 Hz for 1 min between coil and  
contacts*;  
5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;  
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity  
1,000 VAC, 50/60 Hz for 1 min between contacts of
 
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity  
same polarity  
Vibration resistance  
Shock resistance  
Destruction: 10
 
to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
Malfunction: 10
 
to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
Destruction: 1,000
 
m/s

2  

Malfunction: 200
 
m/s

2

when energized; 100 m/s

2

when not energized  
Service life  
Mechanical:  
AC coil: 10,000,000 operations min.;  
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)  
100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)  
Electrical:  
Ambient temperature
 
Operating:  
–40
°
C to 70
°
C (with no icing or condensation)  
Ambient humidity  
Weight  
Operating:  
5% to 85%  
Approx. 21 g  
Note:
Values in the above table are the initial values.  
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is used.  
■
Approved Standards  
UL 508 (File No. E41643)  
IEC/VDE (EN61810)  
Model  
Contact Coil
 
ratings  
form  
Contact ratings  
Opera-  
tions  
Contact  
form  
Coil ratings  
Contact ratings  
Operations  
6 x 10

3  

100 x 10

3  

G2R-1-S SPDT  
G2R-2-S DPDT  
5 to 110 VDC
 
10 A, 30 VDC (resistive)  
5 to 240 VAC
 
10 A, 250 VAC (general use)  
TV-3 (NO contact only)  
1 pole  
6, 12, 24, 48 VDC  
24, 110, 120, 230,  
240 VAC  
5 A, 440 VAC (cos
φ
= 1.0)  
10 A, 250 VAC (cos
φ
= 1.0)  
10 A, 30 VDC (0 ms)  
6 x 10

3  

100 x 10

3  

5 A, 30 VDC (resistive)  
5 A, 250 VAC (general use)  
TV-3 (NO contact only)  
2 poles  
6, 12, 24, 48 VDC  
24, 110, 120, 230,  
240 VAC  
5 A, 250 VAC (cos
φ
=1.0)  
5 A, 30 VDC (0 ms)  
CSA 22.2 No.0, No.14  
(File No. LR31928)  
LR  
Number of
 
Coil ratings  
poles  
Contact ratings  
Operations  
Model  
Contact Coil
 
ratings  
form  
Contact ratings  
Opera-  
tions  
6 x 10

3  

100 x 10

3  

1 pole  
5 to 110 VDC
 
10 A, 250 VAC (general use)  
5 to 240 VDC
 
7.5 A, 250 VAC (PF0.4)  
10 A, 30 VDC (resistive)  
G2R-1-S SPDT  
G2R-2-S DPDT  
5 to 110 VDC
 
10 A, 30 VDC (resistive)  
5 to 240 VAC
 
10 A, 250 VAC (general use)  
TV-3 (NO contact only)  
5A, 30VDC (L/R=7ms)  
100 x 10

3  

2 poles  
5 to 110 VDC
 
5 A, 250 VAC (general use)  
5 to 240 VDC
 
2 A, 250 VAC (PF0.4)  
5 A, 30 VDC (resistive)  
6 x 10

3  

5 A, 30 VDC (resistive)  
5 A, 250 VAC (general use)  
TV-3 (NO contact only)  
3A, 30VDC (L/R=7ms)  
General-purpose Relay
G2RS  
3

Engineering Data  
■
Maximum Switching Capacity  
Plug-in Relays  
G2R-1-S  
G2R-2-S  
100  
100  
AC inductive load  
(cos
φ
= 0.4)  
AC resistive  
load  
AC inductive load  
(cos
φ
= 0.4)  
AC resistive  
load  
10  
10  
1
DC resistive  
load  
DC resistive  
load  
DC inductive load  
(L/R = 7 ms)  
1
DC inductive load  
(L/R = 7 ms)  
0.1  
0.1  
1
10  
100  
1000  
1
10  
100  
1000  
Switching voltage (V)  
Switching voltage (V)  
■
Electrical Service Life  
Plug-in Relays  
G2R-1-S  
G2R-2-S  
10,000  
5,000  
5,000  
250-VAC/30-VDC  
1,000  
500  
resistive load  
1,000  
500  
250-VAC inductive load  
(cos
φ
= 0.4)  
30-VDC inductive load (L/R = 7ms)  
250-VAC/30-VDC  
resistive load  
100  
50  
100  
50  
30-VDC inductive load (L/R = 7ms)  
250-VAC  
inductive load  
(cos
φ
= 0.4)  
Switching current (A)  
Switching current (A)  
Ambient Temperature vs. Maximum Coil Voltage  
DC coil  
AC coil  
Note:
The maximum voltage refers to the maximum  
value in a varying range of operating power  
voltage, not a continuous voltage.  
Ambient temperature (
°
C)  
4
General-purpose Relay
G2RS  

Dimensions  
Unit: mm (inch)  
■
Relays with Plug-in Terminals  
SPDT Relays  
Terminal Arrangement/Internal Connections  
(Bottom View)  
G2R-1-S, G2R-1-SN, G2R-1-SNI  
G2R-1-SD, G2R-1-SND, G2R-1-SNDI  
G2R-1-SD (DC)  
G2R-1-S  
1
5
1
5
13 max.  
(0.51)  
29 (1.14) max.  
2
4
3
2
4
3
35.5 max.  
(1.40)  
G2R-1-SN, G2R-1-SNI (DC)  
G2R-1-SN, G2R-1-SNI (AC)  
20  
(0.79)  
1
1
D
C
24V  
5 (0.20)  
1(0.04)  
4.75  
(0.19)  
0.5  
(0.02)  
2
4
3
2
4
3
5
5
7.5 (0.29)  
G2R-1-SND, G2R-1-SNDI (DC)  
5.2  
5.2  
(0.20)  
(0.20)  
17.5  
1
(0.69)  
2
4
3
5
DPDT Relays  
G2R-2-S, G2R-2-SN, G2R-2-SNI  
G2R-2-SD, G2R-2-SND, G2R-2-SNDI  
Terminal Arrangement/Internal Connections  
(Bottom View)  
G2R-2-S  
G2R-2-SD (DC)  
1
2
7
3
6
4
5
1
2
7
3
4
29 max.  
(1.14)  
13 max.  
(0.51)  
8
8
6
5
35.5 max.  
(1.40)  
G2R-2-SN, G2R-2-SNI (AC)  
G2R-2-SN, G2R-2-SNI (DC)  
20  
(0.79)  
1
8
2
7
3
6
4
5
1
8
2
7
3
6
4
5
6.2  
(0.29)  
2.5  
(0.10)  
0.5  
(0.02)  
2.4  
(0.09)  
7.4  
8.9  
(0.29)  
(0.35)  
G2R-2-SND, G2R-2-SNDI (DC)  
5 (0.02)  
5 (0.02)  
1
8
2
7
3
6
4
5
19.4  
(0.76)  
General-purpose Relay
G2RS  
5

Track/Surface Mounting Sockets  
P2RF-05-S  
T
e
rminal Arrangement  
(
T
o
p View)  
38.2 max. (1.50)  
36.5 max. (1.44)  
11  
14  
12  
32.6 (1.28)  
27.6 (1.09)  
22.6  
(0.89)  
24.5  
(0.96)  
35.4  
(1.39)  
92.0 max.  
(3.62)  
A1 A2  
Option (with ejector and  
Standard model  
label attached)  
28.5 (1.12)  
5.3 typical  
(0.21)  
18.0 max.  
(0.71)  
32.6  
(1.28)  
T
e
rminal Arrangement  
(
T
o
p View)  
38.2 max. (1.50)  
P2RF-08-S  
36.5 max.(1.44)  
21 11  
24 14  
22 12  
32.6 (1.28)  
27.6 (1.09)  
22.6  
(0.89)  
3.4 (0.13) typical  
24.5  
(0.96)  
92.0 max.  
(3.62)  
35.4  
(1.39)  
A1 A2  
Option (with ejector  
and label attached)  
Standard model  
28.6 (1.12)  
32.6 (1.28)  
5.3 typical  
(0.21)  
18.0 max.  
(0.71)  
Accessories for P2RF-
@
-S  
Socket Bridge  
Clip and Release Lever  
16.8  
(0.66)  
40.35  
(1.59)  
Note:
The color of insulating coating indicates power type.  
36  
(1.42)  
Model  
P2RM-SR  
P2RM-SB  
Power  
Color  
AC  
DC  
Red  
Blue  
6
General-purpose Relay
G2RS  

Terminal Arrangement  
(Top View)  
Mounting Holes  
(for Surface Mounting)  
P2RF-05-E  
2 (0.08)  
Five, M3.5
×
7  
48 max.  
(1.89)  
3.2 (0.13)  
dia. hole  
(11)  
4
39.5  
(1.55)  
35.5  
(1.40)  
2
(14)  
3
(12)  
39.5 0.1  
(1.55 0.004)  
85.5 max.  
(3.37)  
3.5 (0.14)  
dia. hole  
5
M3 or 3.5  
(0.14) dia.  
(A1)  
(A2)  
1
5
11.5  
(0.20)  
(0.45)  
16.0 max.  
(0.63)  
61 max.  
(2.40)  
Note:
Pin numbers in parentheses apply to DIN standard.  
P2RF-08-E  
Terminal Arrangement  
(Top View)  
Mounting Holes  
(for Surface Mounting)  
1.5  
(0.06)  
2 (0.08)  
3 (0.12)  
48.0 max.  
(1.89)  
Eight, M3
×
8  
2 (0.08)  
(11)  
(12)  
(14)  
(21)  
(22)  
(24)  
6
3
2
4
3.2 (0.13)  
dia. hole  
7
5
39.5  
(1.55)  
35.5  
(1.40)  
85.5 max  
(3.37)  
39.5 0.1  
(1.55 0.004)  
8
3.5 (0.14)  
dia. hole  
(A1)  
1
M3 or 3.5 (0.14)  
dia. hole  
(A2)  
11.5 (0.45)  
5 (0.20)  
61.0 max.  
(2.40)  
16.0 (0.63) max.  
2 (0.08)  
7(0.28)  
Five, M3.5 x 8  
P2RF-05  
Terminal Arrangement  
(Top View)  
Mounting Holes  
(for Surface Mounting)  
4 (0.16)  
dia. holes  
4.2 (0.16)  
dia. hole  
71.5 max.  
35.5  
(2.81)  
(1.40)  
30 0.05  
(1.18 0.002)  
4
19.5 (0.77)  
30 max.(1.18)  
M3 or 3.2 (0.13)  
dia. hole  
19.5 max.  
(0.77)  
(0.16)  
54 max.  
(2.12)  
P2RF-08  
2 (0.08)  
7 (0.28)  
Eight, M3.5 x 8  
Terminal Arrangement  
(Top View)  
Mounting Holes  
(for Surface Mounting)  
4.2 (0.16) dia. hole  
4 (0.16)  
dia. holes  
71.5 max.  
(2.89)  
35.5  
(1.40)  
30 0.05  
(1.18 0.002)  
19.5 (0.77)  
30 max.(1.18)  
4 (0.16)  
19.5 max.  
(0.77)  
M3 or 3.2 (0.13)  
dia. hole  
54 max.  
(2.12)  
General-purpose Relay
G2RS  
7

Mounting Height of Relay with Track/Surface Mounting Sockets  
P2RF-
@
-E  
P2RF-
@  
62.0  
(2.44)  
66.5  
(2.62)  
67.0  
(2.64)  
70.5  
(2.77)  
P2RF-
@
-S  
72.0  
(2.83)  
65.0  
(2.56)  
28.6  
(1.12)  
5.30 (0.21) typical  
Back-connecting Sockets  
Terminal Arrangement  
(Bottom View)  
Mounting Holes  
14.5 max.  
(0.57)  
P2R-05P (1-pole)  
T
o
lerance: 0.1  
4 (0.16)  
1(0.04)  
7 (0.27)  
4 (0.14)  
Five, 1.6 (0.06)  
dia. holes  
6 (0.24)  
4.5 (0.18)  
15  
35.5 max.  
(1.40)  
6 (0.24)  
(0.59)  
4.5 (0.18)  
15 (0.59)  
1.2 (0.05)  
4 (0.16)  
3.5  
(0.14)  
4 (0.16)  
1.5 (0.06)  
5 (0.20) typical  
7 (0.27)  
4 (0.16)  
7 (2.27)  
36.5 max.  
(1.44)  
P2R-08P (2-pole)  
14.5 max.  
(0.57)  
Terminal Arrangement  
(Bottom View)  
Mounting Holes  
4 (0.16)  
0.3  
7 (0.27)  
7.5  
(0.29)  
Eight, 1.3 (0.05)  
dia. holes  
(0.01)  
5 (0.20)  
5 (0.20)  
35.5 max.  
(1.40)  
5 (0.20)  
20  
(0.79)  
1 (0.04)  
5 (0.20)  
20  
(0.79)  
2.8 (0.11)  
1.5 (0.06)  
7.5 (0.29)  
4.3 (0.17) typical  
T
e
rminal plate thickness: 0.3 (0.01)  
36.5 max. (1.44)  
8
General-purpose Relay
G2RS  

5 (0.20)  
0.3  
(0.01)  
14.5 max.  
(0.57)  
7 (0.28)  
1.2 (0.05)  
P2R-05A (1-pole)  
Terminal Arrangement  
(Bottom View)  
6.7 (0.26)  
3.8 (0.15)  
35.5 max.  
(1.40)  
16.7  
(0.66)  
5 (0.20)  
Panel Cutout  
Five, 3 x 1.8-dia. holes  
(0.12 x 0.07)  
13.6 0.1  
(0.54 0.004)  
6 (0.24)  
36.5 max.  
(1.44)  
T
e
rminal plate thickness: 0.3  
7 (0.28)  
30.5 0.2  
(1.20 0.008)  
14.5 max.  
(0.57)  
7 (0.28)  
1.2 (0.05)  
P2R-08A (2-pole)  
0.3  
(0.01)  
5 (0.20)  
5 (0.20)  
35.5 max.  
(1.40)  
20  
Recommended thickness of  
the panel is 1.6 to 2.0 mm  
(0.79)  
2.6 (0.10)  
2.8(0.11)  
1.5 (0.06)  
Eight, 3 x 1.2  
(0.12 x 0.05)dia. holes  
7.5  
(0.30)  
T
e
rminal plate thickness: 0.3  
36.5 max.  
(1.44)  
P2R-057P

14 max. (0.55)  

Terminal Arrangement  
(Bottom View)  
Mounting Holes  
4 0.1  
16.4 (0.65)  
10.4  
0.7 (0.03)  
1(0.04)  
8.7  
(0.16 0.004)  
(0.41)  
Five, 1.6 (0.06)  
dia. holes  
6 0.1(0.24 0.004)  
(0.34)  
29.6  
(1.17)  
37 max.  
(1.46)  
4.5 0.1  
(0.18 0.004)  
15 0.1(0.59 0.004)  
7.4 (0.29)  
4 0.1
 
(0.16 0.004)  
5 (0.20)  
8.7  
(0.34)  
7 0.1(0.27 0.004)  
41 max.  
(1.61)  
14 max.  
(0.55)  
Terminal Arrangement  
(Bottom View)  
Mounting Holes  
16.4(0.65)  
1 (0.04)  
P2R-087P  
10.4  
7.5  
(0.30)  
7.5 (0.30)  
Eight, 1.3 (0.05)  
(0.41)  
dia. holes  
37 max.  
29.1  
(1.15)  
(1.46)  
5 (0.20)  
5 (0.20)  
20  
(0.79)  
7.4 (0.29)  
8.9 (0.35)  
8.1(0.32) typical  
41 max.  
(1.61)  
General-purpose Relay
G2RS  
9

Mounting Height of Relay with Back-connecting Sockets  
G2R-
@
P  
G2R-
@
A  
G2R-
@
7P  
G2R Relay  
G2R Relay  
47.5  
(1.87)  
38.0  
(1.50)  
44.5  
(1.75)  
P2R-_A  
Socket  
P2R-_P  
Socket  
Mounting Tracks  
PFP-100N, PFP-50N  
PFP-100N2  
16 (0.63)  
7.3 0.15  
(0.29 0.006)  
4.5  
4.5 (0.18)  
(0.18)  
24  
(0.94)  
27  
(1.06)  
29.2  
(1.15)  
35 0.3  
(1.38 0.01)  
27 0.15  
1
35 0.3  
15  
25  
25  
10 (0.39)  
25  
25  
10 (0.39)  
25  
25  
15 (0.59)  
25 (0.98)  
1 (0.04)  
1.5 (0.06)  
15 (0.59)  
25 (0.98)  
1,000 (39.37)  
or 500 (19.68)  
15(0.59)  
or 5 (0.20)  
10  
10  
1,000  
(39.37)  
It is recommended to use a panel 1.6 to 2.0 mm thick.  
End Plate  
Spacer  
16 (0.63)  
10 (0.39)  
6.2 (0.24)  
5 (0.20)  
12 (0.47)  
PFP-M  
PFP-S  
1.8 (0.07)  
1 (0.04)  
35.5  
(1.40)  
35.3  
(1.39)  
50  
(1.97)  
34.8  
(1.37)  
1.8  
(0.07)  
44.3  
(1.74)  
11.5  
(0.45)  
1.3 (0.05)  
4.8 (0.19)  
10 (0.39)  
M4 x 8 pan  
head screw  
16.5 (0.65)  
Precautions  
Precautions for P2RF-
@
-S Connection  
•
Do not move the screwdriver up, down, or from side to side while it  
is inserted in the hole. Doing so may cause damage to internal  
components (e.g., deformation of the clamp spring or cracks in the  
housing) or cause deterioration of insulation.  
!Caution  
Do not use the test button for any purpose other than testing. Be  
sure not to touch the test button accidentally as this will turn the  
contacts ON. Before using the test button, confirm that circuits, the  
load, and any other connected item will operate safely.  
•
Do not insert the screwdriver at an angle. Doing so may break the  
side of the socket and result in a short-circuit.  
!Caution  
Check that the test button is released before turning ON relay cir-  
cuits.  
!Caution  
If the test button is pulled out too forcefully, it may bypass the mo-  
mentary testing position and go straight into the locked position.  
!Caution  
Use an insulated tool when you operate the test button.  
10  
General-purpose Relay
G2RS  

Certain Terms and Conditions of Sale  
1. Offer;
 
Acceptance. These terms and conditions (these “
T
e
rms”) are deemed
 
12. Warranties.
 
(a) Exclusive Warrant
y
.
 
S
eller’s exclusive warranty is that the  
part of all catalogs, manuals or other documents, whether electronic or in writ-  
ing, relating to the sale of goods or services (collectivel
y
,
t
he “Goods”) by  
Omron Electronics LLC and its subsidiary companies (“Seller”).
 
Seller hereby  
objects to any terms or conditions proposed in Buyer’s purchase order or other  
documents which are inconsistent with, or in addition to, these
T
e
rms.
 
Please  
contact your Omron representative to confirm any additional terms for sales  
from your Omron compan
y
.  
Goods will be free from defects in materials and workmanship for a period of  
twelve months from the date of sale by Seller (or such other period expressed  
in writing by Seller).
 
Seller disclaims all other warranties, express or implied.  
(b) Limitations.
 
SELLER MAKES NO WARRANTY OR REPRESEN
T
A
T
ION,  
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMEN
T
,
M
ERCHAN
T
A
BIL-  
ITY OR FITNESS FOR  
A
P
A
RTICULAR PURPOSE OF THE GOODS.  
BUYER ACKNOWLEDGES TH
A
T
I
T ALONE HAS DETERMINED TH
A
T
T
HE  
GOODS WILL SUI
T
A
B
L
Y
M
EET THE REQUIREMENTS OF THEIR  
INTENDED USE.
 
Seller further disclaims all warranties and responsibility of  
any type for claims or expenses based on infringement by the Goods or other-  
wise of any intellectual property right.
 
(c) Buyer Remed
y
.
S
eller’s sole obliga-  
tion hereunder shall be to replace (in the form originally shipped with Buyer  
responsible for labor charges for removal or replacement thereof) the non-  
complying Good or, at Seller’s election, to repay or credit Buyer an amount  
equal to the purchase price of the Good; provided that in no event shall Seller  
be responsible for warrant
y
,
r
epair, indemnity or any other claims or expenses  
regarding the Goods unless Seller’s analysis confirms that the Goods were  
properly handled, stored, installed and maintained and not subject to contami-  
nation, abuse, misuse or inappropriate modification.
 
Return of any goods by  
Buyer must be approved in writing by Seller before shipment.
 
Seller shall not  
be liable for the suitability or unsuitability or the results from the use of Goods  
in combination with any electrical or electronic components, circuits, system  
assemblies or any other materials or substances or environments.
 
Any  
advice, recommendations or information given orally or in writing, are not to be  
construed as an amendment or addition to the above warrant
y
.  
2. Prices. All
 
prices stated are current, subject to change without notice by  
Seller. Buyer
 
agrees to pay the price in effect at time of shipment.  
3. Discounts.
 
Cash discounts, if an
y
,
w
ill apply only on the net amount of  
invoices sent to Buyer after deducting transportation charges, taxes and  
duties, and will be allowed only if (i) the invoice is paid according to Seller’s  
payment terms and (ii) Buyer has no past due amounts owing to Seller.  
4. Orders.
 
Seller will accept no order less than $200 net billing.  
5. Governmental
 
Approvals. Buyer
 
shall be responsible for, and shall bear all  
costs involved in, obtaining any government approvals required for the impor-  
tation or sale of the Goods.  
6.
T
a
xes.
 
All taxes, duties and other governmental charges (other than general  
real property and income taxes), including any interest or penalties thereon,  
imposed directly or indirectly on Seller or required to be collected directly or  
indirectly by Seller for the manufacture, production, sale, deliver
y
,
i
mportation,  
consumption or use of the Goods sold hereunder (including customs duties  
and sales, excise, use, turnover and license taxes) shall be charged to and  
remitted by Buyer to Seller.  
7. Financial.
 
If the financial position of Buyer at any time becomes unsatisfactory  
to Seller, Seller reserves the right to stop shipments or require satisfactory
 
13. Damage Limits; Etc.
 
SELLER SHALL NOT BE LIABLE FOR SPECIAL, INDI-  
security or payment in advance.
 
If Buyer fails to make payment or otherwise  
comply with these
T
e
rms or any related agreement, Seller may (without liability  
and in addition to other remedies) cancel any unshipped portion of Goods sold  
hereunder and stop any Goods in transit until Buyer pays all amounts, includ-  
ing amounts payable hereunder, whether or not then due, which are owing to it  
by Buyer.
 
Buyer shall in any event remain liable for all unpaid accounts.  
8. Cancellation;
 
Etc. Orders are not subject to rescheduling or cancellation  
unless Buyer indemnifies Seller fully against all costs or expenses arising in  
connection therewith.  
RECT OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUC-  
TION OR COMMERCIAL LOSS IN ANY W
A
Y
C
ONNECTED WITH THE  
GOODS, WHETHER SUCH CLAIM IS BASED IN CONTRAC
T
, WARRANT
Y
,  
NEGLIGENCE OR STRICT LIABILIT
Y
.
 
F
urther, in no event shall liability of  
Seller exceed the individual price of the Good on which liability is asserted.  
14. Indemnities.
 
Buyer shall indemnify and hold harmless Seller, its affiliates and  
its employees from and against all liabilities, losses, claims, costs and  
expenses (including attorney’s fees and expenses) related to any claim, inves-  
tigation, litigation or proceeding (whether or not Seller is a party) which arises  
or is alleged to arise from Buyer’s acts or omissions under these
T
e
rms or in  
any way with respect to the Goods.
 
Without limiting the foregoing, Buyer (at  
its own expense) shall indemnify and hold harmless Seller and defend or settle  
any action brought against Seller to the extent that it is based on a claim that  
any Good made to Buyer specifications infringed intellectual property rights of  
another part
y
.  
15. Property; Confidentialit
y
.
 
T
he intellectual property embodied in the Goods is  
the exclusive property of Seller and its affiliates and Buyer shall not attempt to  
duplicate it in any way without the written permission of Seller.
 
Notwithstand-  
ing any charges to Buyer for engineering or tooling, all engineering and tooling  
shall remain the exclusive property of Seller.
 
All information and materials  
supplied by Seller to Buyer relating to the Goods are confidential and propri-  
etar
y
,
a
nd Buyer shall limit distribution thereof to its trusted employees and  
strictly prevent disclosure to any third part
y
.  
16. Miscellaneous.
 
(a) Waiver.
 
No failure or delay by Seller in exercising any right  
and no course of dealing between Buyer and Seller shall operate as a waiver  
of rights by Seller. (b) Assignment.
 
Buyer may not assign its rights hereunder  
without Seller’s written consent.
 
(c) Amendment.
 
These
T
e
rms constitute the  
entire agreement between Buyer and Seller relating to the Goods, and no pro-  
vision may be changed or waived unless in writing signed by the parties.  
(d) Severabilit
y
.
 
I
f any provision hereof is rendered ineffective or invalid, such  
provision shall not invalidate any other provision. (e) Setoff.
 
Buyer shall have  
no right to set off any amounts against the amount owing in respect of this  
invoice. (f)
 
As used herein, “including” means “including without limitation”.  
9. Force
 
Majeure. Seller
 
shall not be liable for any delay or failure in delivery  
resulting from causes beyond its control, including earthquakes, fires, floods,  
strikes or other labor disputes, shortage of labor or materials, accidents to  
machiner
y
,
a
cts of sabotage, riots, delay in or lack of transportation or the  
requirements of any government authorit
y
.  
10. Shipping; Deliver
y
.
 
U
nless otherwise expressly agreed in writing by Seller:  
a. Shipments shall be by a carrier selected by Seller;  
b. Such
 
carrier shall act as the agent of Buyer and delivery to such carrier  
shall constitute delivery to Buyer;  
c. All
 
sales and shipments of Goods shall be FOB shipping point (unless oth-  
erwise stated in writing by Seller), at which point title to and all risk of loss of  
the Goods shall pass from Seller to Buyer, provided that Seller shall retain a  
security interest in the Goods until the full purchase price is paid by Buyer;  
d. Delivery and shipping dates are estimates onl
y
.  
e. Seller will package Goods as it deems proper for protection against normal  
handling and extra charges apply to special conditions.  
11. Claims.
 
Any claim by Buyer against Seller for shortage or damage to the  
Goods occurring before delivery to the carrier must be presented in writing to  
Seller within 30 days of receipt of shipment and include the original transporta-  
tion bill signed by the carrier noting that the carrier received the Goods from  
Seller in the condition claimed.  
Certain Precautions on Specifications and Use  
1. Suitability
 
of Use.
 
Seller shall not be responsible for conformity with any stan-
 
2. Programmable
 
Products. Seller
 
shall not be responsible for the user’s pro-  
dards, codes or regulations which apply to the combination of the Good in the  
gramming of a programmable Good, or any consequence thereof.  
Buyer’s application or use of the Good.
 
At Buyer’s request, Seller will provide
 
3. Performance
 
Data. Performance
 
data given in this catalog is provided as a  
applicable third party certification documents identifying ratings and limitations  
of use which apply to the Good.
 
This information by itself is not sufficient for a  
complete determination of the suitability of the Good in combination with the  
end product, machine, system, or other application or use.
 
The following are  
guide for the user in determining suitability and does not constitute a warrant
y
.  
It may represent the result of Seller’s test conditions, and the user must corre-  
late it to actual application requirements.
 
Actual performance is subject to the  
Seller’s Warranty and Limitations of Liabilit
y
.  
some examples of applications for which particular attention must be given.
 
4. Change
 
in Specifications.
 
Product specifications and accessories may be  
This is not intended to be an exhaustive list of all possible uses of this Good,  
nor is it intended to imply that the uses listed may be suitable for this Good:  
(i) Outdoor
 
use, uses involving potential chemical contamination or electrical  
interference, or conditions or uses not described in this document.  
(ii) Energy
 
control systems, combustion systems, railroad systems, aviation  
systems, medical equipment, amusement machines, vehicles, safety  
equipment, and installations subject to separate industry or government  
regulations.  
changed at any time based on improvements and other reasons.
 
It is our prac-  
tice to change part numbers when published ratings or features are changed,  
or when significant construction changes are made.
 
However, some specifica-  
tions of the Good may be changed without any notice.
 
When in doubt, special  
part numbers may be assigned to fix or establish key specifications for your  
application. Please
 
consult with your Seller’s representative at any time to con-  
firm actual specifications of purchased Good.  
5. Errors
 
and Omissions.
 
The information in this catalog has been carefully  
checked and is believed to be accurate; however, no responsibility is assumed  
for clerical, typographical or proofreading errors, or omissions.  
(iii) Systems, machines and equipment that could present a risk to life or  
propert
y
.
P
lease know and observe all prohibitions of use applicable to  
this Good.  
NEVER USE THE PRODUCT FOR AN APPLIC
A
T
ION INVO
L
V
ING SERIOUS  
RISK TO LIFE OR PROPERTY WITHOUT ENSURING TH
A
T
T
HE SYSTEM  
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND TH
A
T  
THE SELLER’S PRODUCT IS PROPER
L
Y
R
A
T
ED AND INS
T
A
LLED FOR  
THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
General-purpose Relay
G2RS  
11  

Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website  

at www.omron.com/oei

–
under the “About Us” tab, in the Legal Matters section.  
OMRON ON-LINE  
OMRON ELECTRONICS LLC  
55 East Commerce Drive, Suite B  
Schaumburg, IL 60173-5302  
OMRON CANADA, INC.  
885 Milner Avenue  
T
o
ronto, Ontario M1B 5V8  
847-882-2288  
416-286-6465  
Cat. No. J140-E3-01  
11/03/2.5M  
Specifications subject to change without notice  
Printed in USA  
12  
General-purpose Relay
G2RS