Omron-Electronics-G2RL-1A-E2-CV-HA-DC5
| Part # | Omron-Electronics-G2RL-1A-E2-CV-HA-DC5 |
| Download | Omron-Electronics-G2RL-1A-E2-CV-HA-DC5 |
G2RL-1A-E2-CV-HA
PCB Power Relay
Compact single pole Relay for
High Current Load Switching &
High Ambient Temperature
G
2
R
L
I
E
2
• High current 23 A switching surpassing standard G2RL models.
• Meets ambient operating temperature requirements of 105°C
• Low profile; 16.7 mm max. in height.
G
2
R
L
• Reinforced insulation between coil and contact with 10 kV Impulse voltage.
• Conforms to EN60335-1 of Safety of Household appliances.
• Clearance and creepage distances: 8 mm / 8 mm min.
• Coil insulation system: Class F (UL1446)
1
A
RoHS Compliant
E
2
Model Number Legend
Application Examples
C
G2RL-
@ @ @
–
@
–
@
–
@
V
• Home appliances
• Cooking top, Microwave Oven
• Industrial use
1 2 3
4
5
6
H
4. Classification
1. Number
of pole
A
E2: High-capacity at 23 A
1: 1 Pole
• HVAC
5. Special
Requirement
2. Contact
Form
CV: Ambient operating temperature 105°C
A: SPST-NO (1a)
6. Market
Code
3. Enclosure
Rating
HA: Home Appliance according to IEC/EN60335-1
None: Flux protection
Ordering Information
Classification
Contact form
Enclosure rating
Model
Rated coil voltage
Minimum packing unit
5 VDC
12 VDC
24 VDC
High-capacity &
High-temperature
SPST-NO (1a)
Flux protection
G2RL-1A-E2-CV-HA
100 pcs. / tray
Note: 1.
When ordering, add the rated coil voltage to the model number.
Example: G2RL-1A-E2-CV-HA DC5
Rated coil voltage
However, the notation of the coil voltage on the product case will be marked as
@@
VDC.
Note: 2.
Place your order in tray (100 pcs./tray) units.
Ratings
●
Coil Ratings
Must-operate voltage
Must-release voltage
Item
Max. voltage (V)
Rated current
(mA)
Coil resistance
Power consumption
(mW)
(V)
(V)
(
Ω
)
Rated voltage
% of rated voltage
5 VDC
80.0
33.3
16.7
62.5
360
130%
(at 23°C)
12 VDC
24 VDC
75% max.
10% min.
Approx. 400
1,440
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note: 2.
The operating characteristics are measured at a coil temperature of 23°C.
Note: 3.
The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
●
Contact
Classification
Model
High-capacity & High-temperature type (resistive load)
G2RL-1A-E2-CV-HA
Item
Contact type
Single
Contact material
Ag-Alloy (Cd free)
23 A at 250 VAC
23 A
Rated load
Rated carry current
Max. switching voltage
Max. switching current
250 VAC
23 A
1
G2RL-1A-E2-CV-HA
PCB Power Relay
Characteristics
Classification
High-capacity & High-temperature type
G2RL-1A-E2-CV-HA
Item
Model
Contact resistance
*
1
Operate time
100 m
Ω
max.
15 ms max.
Release time
5 ms max.
G
2
R
L
I
E
2
Insulation resistance
*
2
1,000 M
Ω
min.
5,000 VAC, 50/60 Hz for 1 min
Between coil and contacts
Dielectric strength
Between contacts of the
same polarity
1,000 VAC, 50/60 Hz for 1 min
Impulse withstand voltage
10 kV (1.2 × 50 µs)
G
2
R
L
Destruction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s
2
Vibration resistance
Shock resistance
Malfunction
Destruction
Malfunction
Mechanical
Energized: 100 m/s
2
, De-energized: 100 m/s
2
1
A
20,000,000 operations (18,000 operation per hour)
Durability
Electrical
*
3
(resistive load)
100,000 operations at 250 VAC, 23 A, at 105°C (1s ON / 9s OFF)
E
Ambient operating temperature
Ambient operating humidity
-40°C to 105°C (with no icing or condensation)
5% to 85% (with no icing or condensation)
Approx. 12 g
2
C
Weight
V
Note:
Values in the above table are the initial values at 23°C.
*1.
Measurement conditions: 5 VDC, 1 A, voltage drop method
*2.
Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
*3.
360 operations per hour.
H
A
Engineering Data
●
Maximum Switching Capacity
●
Ambient Temperature vs. Maximum Coil Voltage
25
23
200
180
20
15
10
5
150
130
100
50
0
0
0
50
100
150
200
250 300
0
20 23
40
60
80
100 105
120
Switching voltage (V)
Ambient Temperature (°C)
Note:
The maximum coil voltage refers to the maximum value in a varying
range of operating power voltage, not a continuous voltage.
●
Shock Malfunction
●
Ambient Temperature vs.
Must Operate and Must Release Voltage
Y
100
Test conditions: Shock is applied
1,000
Must operate voltage
Must release voltage
90
in ±X, ±Y, and ±Z directions three
times each with without energizing
the Relays to check the number of
malfunctions.
Requirement: None malfuction
100 m/s
2
80
70
60
50
40
30
20
max.
X
min.
X’
1,000
Z
1,000
max.
X
min.
130
1,000
X
Shock direction
1,000
Z’
10
0
X
X’
Y
Z
Z’
0
20
40
60
80
100
120
Ambient Temperature (°C)
1,000
Y’
Unit: m/s
2
Y’
2
G2RL-1A-E2-CV-HA
PCB Power Relay
Dimensions
(Unit: mm)
G2RL-1A-E2-CV-HA
PCB Mounting Holes
Terminal Arrangement/
Internal Connections
(Bottom View)
(Bottom View)
5
Six, 1.3-dia. holes
(2.5)
12.7 max.
(12.5)*
29 max.
(28.8)*
1
3
4
G
2
R
L
I
E
2
7.5
16.7 max.
(16.5)*
8
6
5
(2.3)
20
(No coil polarity)
0.5
0.5
0.8
3.5
0.5
* Average value
G
2
R
Approved Standards
L
UL Recognized:
(File No. E41643)
1
A
CSA Certified:
(File No. LR31928)
Model
Contact form
Coil ratings
Contact ratings
Number of test operations
E
G2RL-1A-E2-CV-HA
SPST-NO (1a)
5 to 24 V
23 A, 250 VAC (Resistive) 105°C
100,000
2
EN/IEC, TÜV:
(Certisfied/No.*****)
C
V
Model
Contact form
Coil ratings
Contact ratings
Number of test operations
G2RL-1A-E2-CV-HA
SPST-NO (1a)
5 to 24 V
23 A, 250 VAC (cos
φ
=1) 105°C
100,000
H
A
Creepage distance
8 mm min.
8 mm min.
IIIa
Clearance distance
Insulation material group
Type of insulation coil-contact
open contact circuit
Reinforced
Micro disconnection
Rated insulation voltage
250 V
Pollution degree
3
Rated voltage system
250 V
Over voltage category
III
Category of protection according to IEC61810-1
Glow wire according to IEC 60335-1
Tracking Index of relay base
Flammability class according to UL94
Coil Insulation system
RTII (flux protection)
GWT 750°C min. (IEC 60695-2-11/GWFI 850°C min (IEC 60695-2-12)
PTI 250
V min. (housing parts)
V-0
F Class (UL 1446)
Precautions
●
Please refer to
PCB Relays Common Precautions
for correct use.
Electrical Appliance and Material Safety Law (Japan)
The G2RL-1A-E2 series is not compliant with the Electrical Appliance and Material Safety Law of Japan. Please pay careful attention to
select a suitable relay for the application.
•
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
•
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
Europe
Asia-Pacific
China
Korea
Japan
© OMRON Corporation 2018
All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. K315-E1-01
1218(1218)(O)
3