Omron-Electronics-G2RL-1A4-E-DC5
| Part # | Omron-Electronics-G2RL-1A4-E-DC5 |
| Download | Omron-Electronics-G2RL-1A4-E-DC5 |
G2RL
PCB Power Relay
Low profile power relay
with 15.7 mm height, ideal for
incorporation in miniature
equipments
• A wide variety of single pole, double pole, high-capacity (16 A)
type and high-sensitivity type (250 mW) relays are available.
• IEC/EN 60335-1 conformed. (-HA Model)
• Satisfies ambient operating temperature requirement of 85°C
and 105°C (-CV Model).
• Clearance and creepage distance: 8 mm / 8 mm min.
• G2RL-1(A)-E-ASI: TV3 rating models available.
• IEC/EN 60079-15 conformed
(Except G2RL-1(A)-H, G2RL-1A-E-CV(-HA) Models).
• Reduced power consumption with voltage holding and pulse
width modulation (PWM) control (only for G2RL-
@
-PW1 model).
■
Application Examples
• Home appliances
• OA equipment
• Industrial machinery
■
Model Number Legend
G
2
R
L
G2RL-
@
@@
–
@
–
@
–
—
@
–
—
@
–
—
@
— — —
—
—
1 2 3
4
5
6 7
8
1. Number of Poles
3. Enclosure Rating
None : Flux protection
5. Contact Material
None : Standard (Ag-allo
y
,
C
d free)
None : General purpose
ASI :
AgSnIn
6. Special Requirement 1
None : Standard
CV :
16 A, pinning 5 mm,
switching at 105°C
7. Market Code
1
2
: 1 pole
: 2 pole
4
: Sealed
HA :
Home Appliance according
4. Classification
to IEC/EN60335-1
2. Contact Form
None : Standard
8. Special Requirement 2
None : Standard
PW1 :Coil holding voltage and
PWM control type
None : SPDT (1c)
E
H
: High-capacity
: High-sensitivity
A
: SPS
T
–
NO (1a)
1
G2RL
PCB Power Relay
■
Ordering Information
Terminal Shape
Market Code
Classification
Contact Form
SPST-NO (1a)
Enclosure Rating
Flux protection
Sealed
Model
G2RL-1A
G2RL-1A-PW1
G2RL-1A4
G2RL-1
G2RL-1-PW1
G2RL-14
G2RL-2A
G2RL-2A-PW1
G2RL-2A4
Rated Coil Voltage
Minimum Packing Unit
5, 12, 24, 48 VDC
5, 12, 24 VDC
5, 12, 24, 48 VDC
5, 12, 24 VDC
Flux protection
Sealed
SPDT (1c)
5, 12, 24, 48 VDC
5, 12, 24 VDC
Standard
Flux protection
Sealed
DPST-NO (2a)
G2RL-2
5, 12, 24, 48 VDC
5, 12, 24 VDC
Flux protection
Sealed
G2RL-2-ASI
G2RL-2-PW1
G2RL-24
DPDT (2c)
SPST-NO (1a)
SPDT (1c)
General
Purpose
G2RL-1A-E
G2RL-1A-E-ASI
G2RL-1A-E-CV
G2RL-1A-E-PW1
G2RL-1A4-E
G2RL-1-E
5, 12, 24, 48 VDC
PCB terminals
Flux protection
20 pcs/tube
5, 12, 24 VDC
High-capacity
Sealed
Flux protection
Sealed
5, 12, 24, 48 VDC
G2RL-1-E-ASI
G2RL-1-E-PW1
G2RL-14-E
5, 12, 24 VDC
5, 12, 24, 48 VDC
G
2
SPST-NO (1a)
SPDT (1c)
SPDT (1c)
DPST-NO (2a)
DPDT (2c)
G2RL-1A-H
G2RL-1-H
High-sensitivity
Standard
R
L
G2RL-1-HA
G2RL-2A-HA
G2RL-2-HA
G2RL-1A-E-HA
G2RL-1A-E-CV-HA
G2RL-1-E-HA
Flux protection
5, 12, 24 VDC
Home
Application
SPST-NO (1a)
SPDT (1c)
High-capacity
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G2RL-1A DC5
Rated coil voltage
However, the notation
of the coil voltage
on the product case will be marked as
@@
VDC.
Note 2. Place your order in tube (20 pcs/tube) units.
Note 3. Contact your OMRON sales representative for sealed models.
■
Ratings
●
Coil
Item
Must operate voltage Must release voltage
Max. voltage
Power consumption
(V)
Rated current
(mA)
Coil resistance
(V)
(V)
(
Ω
)
(mW)
Rated voltage
5 VDC
12 VDC
24 VDC
48 VDC
5 VDC
% of rated voltage
80.0
33.3
16.7
8.96
50
20.8
10.42
62.5
360
1,440
5,358
96
576
2,304
Approx. 400
Approx. 120*
Standard,
High-
10% min.
70% max.
75% max.
10 to 41%*
capacity
130%
Approx. 430
(at 85°C)
High-
sensitivity
12 VDC
24 VDC
10%
Approx. 250
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “max. voltage” is the maximum voltage that can be applied to the relay coil.
*
These numbers are only for -PW1 type. Power consumption with holding voltage is approx.120mW. Please confirm the detail in page 8 coil voltage reduction (holding
voltage).
●
Contacts: Flux Protection Type
Classification
Standard type (resistive load)
High-capacity type (resistive load)
High-sensitivity type (resistive load)
1-pole
Item
Model
1-pole
2-pole
Contact type
Contact material
Single
Ag-alloy (Cd free)
12 A at 250 VAC
8 A at 250 VAC
16 A at 250 VAC
Rated load
10 A at 250 VAC (See note)
10 A (See note)
12 A at 24 VDC (See note)
8 A at 30 VDC (See note)
16 A at 24 VDC (See note)
Rated carry current
12 A (See note)
8 A (70°C)/5 A (85°C) (See note)
16 A (See note)
Max. switching voltage
Max. switching current
440 VAC, 300 VDC
12 A
8 A
16 A
10 A
Failure rate (P level)
(reference value*)
40 mA at 24 VDC
*
This value was measured at a switching frequency of 120 operations/min.
Note: Contact your OMRON representative for the ratings on sealed models.
2
G2RL
PCB Power Relay
■
Characteristics
●
Flux Protection Type
Classification
Standard type
High-capacity type
High-sensitivity type
Item
Number of poles
1-pole
2-pole
1-pole
Contact resistance *1
Operate time
100 m
Ω
max.
15 ms max.
Release time
5 ms max.
Insulation resistance *2
1,000 M
Ω
min.
Between coil and
contacts
5,000 VAC, 50/60 Hz for 1min
Between contacts
of the same
polarity
Dielectric
strength
1,000 VAC, 50/60 Hz for 1min
Between contacts
−
2,500 VAC, 50/60 Hz for 1min
10 kV (1.2 x 50
μ
s)
−
of different polarity
Impulse withstand voltage
Destruction
Malfunction
Destruction
Malfunction
Mechanical
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s
2
Vibration
resistance
Shock
resistance
Energized: 100 m/s
2
, De-energized: 100 m/s
2
20,000,000 operations (at 18,000 operations/hr)
G2RL-1A-E(-ASI, -HA, -PW1),
G2RL-1-E(-ASI, -HA, -PW1):
G2RL-2(A)(-HA, -PW1),
G2RL-1A, G2RL-1(-HA, -PW1):
50,000 operations at 250 VAC, 12 A
30,000 operations at 24 VDC, 12 A
30,000 operations at 250 VAC, 16 A
G2RL-2-ASI:
Durability
Electrical *3
(resistive load)
G2RL-1(A)-H:
50,000 operations at 250 VAC, 10 A
30,000 operations at 24 VDC, 16 A
30,000 operations at 250 VAC, 8 A
G2RL-1A-E-CV(-HA):
30,000 operations at 30 VDC, 8 A
50,000 operations at 250 VAC, 16 A
G
2
at 105°C
-40°C to 85°C (with no icing or condensation)
R
L
Ambient operating temperature
-40°C to 105°C (with no icing or condensation) by G2RL-1A-E-CV
Ambient operating humidity
Weight
5% to 85% (with no icing or condensation)
Approx. 12 g
Note 1. Values in the above table are the initial values at 23°C.
Note 2. Contact your OMRON sales representative for sealed models.
*1. Measurement
conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement
conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
*3. 1,800
operations per hour.
3
G2RL
PCB Power Relay
■
Engineering Data
●
Maximum Switching Capacity
1-pole Standard Type
1-pole High-capacity Type
2-pole Type
50
50
50
AC resistive load
AC resistive load
AC resistive load
10
5
10
5
10
5
DC resistive
load
DC resistive
load
DC resistive
load
1
1
1
0.5
0.5
0.5
0.1
0.1
0.1
0
5
10 20
30 50
100
50
0
1,000
0
5
10 20
30 50
100
50
0
1,000
0
5
10 20
30 50
100
50
0
1,000
Switching voltage (V)
Switching voltage (V)
Switching voltage (V)
●
Ambient Temperature vs. Rated
●
Ambient Temperature vs. Maximum
High-sensitibity Type
Carry Current
Coil Voltage
20
250
50
1-pole High-capacity type
AC resistive load
16
15
200
G
2
10
5
1-pole Standard type
180
G2RL-1A-E-CV
R
L
12
150
130
DC resistive
load
1-pole High-sensitivity type
10
110
100
8
1
Other type
2-pole type
5
0.5
50
0.1
0
10 20 30 40 50 60 70
8
0
8
5 90
100 105 110
0
10 20 30 40 50 60 70
80 85 90 100
Ambient temperature (°C)
0
5
10 20
30 50
100
50
0
1,000
Ambient temperature (°C)
Switching voltage (V)
Note. The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
●
Ambient Temperature vs. Must
Operate and Must Release Voltages
100
Sample:
G2RL-14-E 24 VDC
Number of relays: 5 pcs
Must operate voltage
Must release voltage
90
80
70
60
50
40
30
20
10
max.
X
min.
max.
X
min.
0
20
40
60
80
100 120
Ambient temperature (°C)
4
G2RL
PCB Power Relay
●
Shock Malfunction
1-pole type
2-pole type
Y
1,000
Y
1,000
NO contact
NO contact
Sample: G2RL-14 12 VDC
Number of relays: 5 pcs
Sample: G2RL-24 12 VDC
Number of relays: 5 pcs
X’
Z
X’
Z
Test conditions: Shock is applied
in ±X, ±Y, and ±Z directions three
times each with without energizing
the relays to check the number of
malfunctions.
Test conditions: Shock is applied
in ±X, ±Y, and ±Z directions three
times each with without energizing
the Relays to check the number of
malfunctions.
1,000
1,000
1,000
1,000
150
130
Requirement: None malfuction
Requirement: None malfuction
100 m/s
2
1,000
Z’
100 m/s
2
1,000
X
1,000
X
1,000
NC contact
NC contact
Z’
Shock direction
Shock direction
X
X’
X
X’
Y
Y
Z
Z
1,000
Y’
1,000
Y’
Unit: m/s
2
Unit: m/s
2
Z’
Z’
Y’
Y’
■
Electrical Endurance Data (Reference Value)
8 A 250 VAC (cos
φ
=0.4) 200,000
operation min. (NO)
G2RL-1-E
8 A 30 VDC (L/R=7 ms)
10,000 operation min. (NO)
5 A 250 VAC (cos
φ
=0.4) 150,000
operation min. (NO)
G2RL-1
5 A 30 VDC (L/R=7 ms)
10,000 operation min. (NO)
8 A 250 VAC (cos
φ
=1)
30,000 operation min.
10,000 operation min.
G
2
G2RL-2
8 A 30 VDC
Pilot duty (A300), 250 VAC 250,000 operation min.
Pilot duty (A300), 125 VAC 150,000 operation min.
R
L
G2RL-1A-E
Note. The results shown reflect values at ambient temperature 23°C. Electrical endurance will vary depending on the test conditions.
Contact your OMRON representative if you require more detailed information for the electrical endurance under your test condition.
■
Dimensions
(Unit: mm)
G2RL-1A(-PW1), G2RL-1A4,
G2RL-1A-H
PCB Mounting Holes
(Bottom View)
3.5
Terminal Arrangement/
Internal Connections
(Bottom View)
Four, 1.3-dia. holes
12.7 max.
(12.5)*
29 max.
(28.8)*
(2.5)
1
3
7.5
15.7 max.
(15.5)*
5
4
(2.3)
20
(No coil polarity)
0.5
0.5
0.8
3.5
0.5
* Average value
G2RL-1(-PW1), G2RL-14,
G2RL-1-H, G2RL-1-HA
PCB Mounting Holes
(Bottom View)
3.5 3.5
Terminal Arrangement/
Internal Connections
(Bottom View)
Five, 1.3-dia. holes
(2.5)
12.7 max.
(12.5)*
29 max.
(28.8)*
1
2
3
7.5
15.7 max.
(15.5)*
5
4
(2.3)
20
(No coil polarity)
0.5
0.5
0.8
3.5
0.5
0.5
* Average value
G2RL-1A-E(-HA
,
-PW1),
G2RL-1A4-E,
G2RL-1A-E-CV(-HA),
G2RL-1A-E-ASI
PCB Mounting Holes
Terminal Arrangement/
Internal Connections
(Bottom View)
(Bottom View)
5
Six, 1.3-dia. holes
(2.5)
12.7 max.
(12.5)*
29 max.
(28.8)*
1
3
4
7.5
15.7 max.
(15.5)*
8
6
5
(2.3)
20
(No coil polarity)
0.5
0.5
0.8
3.5
0.5
* Average value
5
G2RL
PCB Power Relay
G2RL-1-E(-ASI, -HA, -PW1)
G2RL-14-E
PCB Mounting Holes
Terminal Arrangement/
Internal Connections
(Bottom View)
Eight, 1.3-dia. holes
(Bottom View)
5
5
12.7 max.
(12.5)*
29 max.
(28.8)*
(2.5)
1
2
3
4
5
7.5
15.7 max.
(15.5)*
8
7
6
(2.3)
20
(No coil polarity)
0.5
0.5
0.5
0.5
0.8
0.8
0.8
3.5
0.5
0.5
0.5
0.5
* Average value
G2RL-2A(-HA, -PW1), G2RL-2A4
PCB Mounting Holes
Terminal Arrangement/
Internal Connections
(Bottom View)
(Bottom View)
5
Six, 1.3-dia. holes
(2.5)
12.7 max.
(12.5)*
29 max.
(28.8)*
1
3
4
7.5
15.7 max.
(15.5)*
8
6
5
(2.3)
20
(No coil polarity)
0.5
3.5
* Average value
G2RL-2(-HA, -PW1), G2RL-24,
G2RL-2-ASI
G
2
PCB Mounting Holes
Terminal Arrangement/
Internal Connections
(Bottom View)
R
L
Eight, 1.3-dia. holes
(Bottom View)
5
5
12.7 max.
(12.5)*
29 max.
(28.8)*
(2.5)
1
2
3
4
5
7.5
15.7 max.
(15.5)*
8
7
6
(2.3)
20
(No coil polarity)
0.5
3.5
0.5
* Average value
■
Approved Standards
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm
the values before use.
UL Recognized:
CSA Certified:
(File No. 41643)
(File No. LR31928)
Number of test
operations
100,000
50,000
Model
Contact form
Coil ratings
3 to 48 VDC
3 to 48 VDC
Contact ratings
G2RL-1A(-PW1)
G2RL-1(-HA, -PW1)
G2RL-1A-E(-HA, -PW1)
G2RL-1-E(-HA, -PW1)
G2RL-1A-E-ASI
G2RL-1-E-ASI
G2RL-1A-E-CV(-HA)
G2RL-1A-H
SPST-NO (1a)
SPDT (1c)
SPST-NO (1a)
SPDT (1c)
SPST-NO (1a)
SPDT (1c)
SPST-NO (1a)
SPST-NO (1a)
SPDT (1c)
12 A, 250 VAC (General Use) 40°C
12 A, 24 VDC (Resistive) 40°C
16 A, 250 VAC (General Use) 40°C
16 A, 24 VDC (Resistive) 40°C
16 A, 250 VAC (Resistive) 85°C
TV-3 40°C
16 A, 250 VAC (Resistive) 105°C
10 A, 250 VAC (General Use) 40°C
10 A, 24 VDC (Resistive) 40°C
100,000
50,000
30,000
25,000
100,000
3 to 48 VDC
3 to 48 VDC
3 to 48 VDC
50,000
G2RL-1-H
G2RL-2A(-HA, -PW1)
G2RL-2(-HA, -PW1)
DPST-NO (2a)
DPDT (2c)
8 A, 277 VAC (General Use) 40°C
3 to 48 VDC
3 to 48 VDC
100,000
8 A, 30 VDC (Resistive) 40°C
8 A, 250 VAC (Resistive) 85°C
8 A, 30 VDC (Resistive) 85°C
15,000
15,000
G2RL-2-ASI
DPDT (2c)
6
G2RL
EN/IEC, VDE Certified
PCB Power Relay
(Certificate No. 119650)
Number of test
operations
Model
Contact form
Coil ratings
Contact ratings
12 A, 250 VAC (cos
φ
=1) 85°C
100,000
12 A, 24 VDC (L/R=0 ms) 85°C
G2RL-1A(-PW1)
SPST-NO (1a)
SPDT (1c)
5, 12, 24, 48
VDC
G2RL-1(-HA, -PW1)
AC15: 3
A at 240 VAC at room temperature
DC13: 2.5 A at 24 VDC, 50ms at room temperature
16 A, 250 VAC (cos
φ
=1) 85°C
6,000
30,000
15,000
16 A, 24 VDC (L/R=0 ms) 85°C
G2RL-1A-E(-HA, -PW1)
G2RL-1-E(-HA, -PW1)
SPST-NO (1a)
SPDT (1c)
5, 12, 24, 48
VDC
AC15: 3
A at 240 VAC (NO) at room temperature,
1.5 A at 240V AC (NC) at room temperature
DC13: 2.5 A at 24 VDC (NO), 50ms at room temperature
6,000
G2RL-1A-E-ASI
G2RL-1-E-ASI
SPST-NO (1a)
SPDT (1c)
5, 12, 24, 48
VDC
16 A, 250 VAC (cos
φ
=1) 85°C
30,000
5, 12, 24, 48
G2RL-1A-E-CV(-HA)
SPST-NO (1a)
16 A, 250 VAC (cos
φ
=1) 105°C
10 A, 250 VAC (cos
φ
=1) 85°C
100,000
VDC
50,000
100,000
50,000
30,000
15,000
G2RL-1A-H
G2RL-1-H
SPST-NO (1a)
SPDT (1c)
5, 12, 24 VDC
10 A, 250 VAC (cos
φ
=1) 40°C
10 A, 24 VDC (L/R=0 ms) 85°C
8 A, 250 VAC (cos
φ
=1) 85°C
8 A, 30 VDC (L/R=0 ms) 85°C
AC15: 1.5
A at 240VAC at room temperature
DC13: 2 A at 30 VDC, 50ms at room temperature
8 A, 250V AC (Resistive) 85°C
G2RL-2A (-HA, -PW1)
G2RL-2 (-HA, -PW1)
G2RL-2-ASI
DPST-NO (2a)
DPDT (2c)
5, 12, 24, 48
VDC
6,000
15,000
15,000
5, 12, 24, 48
VDC
DPDT (2c)
8 A, 30V DC (Resistive) 85°C
CQC Certified
(Certificate No. CQC17002171904)
Number of test
operations
50,000
30,000
50,000
30,000
30,000
30,000
30,000
30,000
30,000
30,000
30,000
30,000
Model
Contact form
Coil ratings
Contact ratings
G
2
12 A, 250 VAC (cos
φ
=1) at room temperature
12 A, 24 VDC (L/R=0 ms) at room temperature
12 A, 250 VAC (cos
φ
=1) at room temperature
12 A, 24 VDC (L/R=0 ms) at room temperature
16 A, 250 VAC (cos
φ
=1) at room temperature
16 A, 24 VDC (L/R=0 ms) at room temperature
16 A, 250 VAC (cos
φ
=1) at room temperature
16 A, 24 VDC (L/R=0 ms) at room temperature
8 A, 250 VAC (cos
φ
=1) at room temperature
8 A, 30 VDC (L/R=0 ms) at room temperature
3 A, 250 VAC (cos
φ
=1) at room temperature
3 A, 30 VDC (L/R=0 ms) at room temperature
G2RL-1A(-PW1)
SPST-NO (1a)
5 to 48 VDC
5 to 48 VDC
5 to 48 VDC
R
L
G2RL-1(-HA, -PW1)
SPDT (1c)
G2RL-1A-E(-ASI, -HA, -PW1)
G2RL-1A-E-CV(-HA)
SPST-NO (1a)
SPDT (1c)
G2RL-1-E(-ASI,-HA, -PW1)
G2RL-2A (4)(-HA, -PW1)
G2RL-2(-ASI,-HA, -PW1)
DPST-NO (2a)
DPDT (2c)
Creepage distance
Clearance distance
Insulation material group
8 mm min.
8 mm min.
IIIa
Type of insulation coil-contact circuit
open contact circuit
Rated Insulation voltage
Pollution degree
Rated voltage system
Over voltage category
Reinforced
Micro disconnection
250 V
3 (Flux protection / Sealed)
250 V / 400 V (Flux protection)
III
Category of protection according to IEC 61810-1
RT II (Flux protection) / RT III (Sealed)
<HA Models only>
Glow wire according to IEC 60335-1
Tracking Index of relay base
GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)
PTI 250 V min. (housing parts)
7
G2RL
PCB Power Relay
■
Precautions
• Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●
Mounting Position Compared to G2R Model
●
Power consumption reduction of coil with pulse width
modulation (PWM)
• Although the G2RL model and the G2R model are both low
profile relays, their characteristics such as switching capacity
are different. Be sure to check operation under the actual
operating conditions before use.
• Models with PWM drive capability (-PW1) can reduce coil
holding current with PWM control. This function reduces power
consumption by reducing the current held by coil.
• Apply the rated voltage for at least 100 ms at the time of relay
operation.
• The following are our verification conditions. When using, it be
sure to check the actual machine under the actual usage
conditions.
●
Cleaning
• The G2RL model is flux-resistant with two sealing holes on the
case. Thus, do not clean the relay by boiling or soaking in
water. Consult your Omron sales representative for sealed
type rela
y
.
●
Using Relays in an Atmosphere Containing Corrosive
Gas
• Do not use relays in an atmosphere containing corrosive gas
(sulfuric or organic gas). Otherwise, connection failure due to
corrosion on the contact surface may lead to functional faults.
●
Coil
V
o
ltage Reduction (Holding Voltage) after Relay
■
Example of drive circuit
■
Conditions of validation carried
out by OMRON
Applied coil
v
oltage (100
%
)
• Applied voltage: rated voltage
• Duty: 60% or more
• Frequency: 10 kHz or more
• Diode Vf: 0.4 V or less
S
u
rge
Relay
Coil
a
b
sorption
diode
Operation
• If the coil voltage is reduced to the holding voltage after relay
operation, first apply the rated voltage to the coil for at least
100 ms, as shown below.
MOS-FET
P
u
lse inp
u
t
• A voltage of at least 55% of the rated voltage is required for the
coil holding voltage. Do not allow voltage fluctuations to cause
the coil holding voltage to fall below this level.
G
2
R
L
100
%
(Rated
v
oltage)
55
%
(Holding
v
oltage)
100ms min.
Applied
coil voltage
Power
consumption
Coil resistance*
62.5
Ω
(5 VDC)
360
Ω
(12 VDC)
1,440
Ω
(24 VDC)
Rated voltage
100%
55%
Approx. 400 mW
Approx. 120 mW
Holding voltage
*
The coil resistance were measured at a coil temperature of 23°C with
tolerances of
10%.
Please check each region’s Terms & Conditions by region website.
OMRON Corporation
Device & Module Solutions Company
Regional Contact
Americas
Europe
Asia-Pacific
China
Korea
Japan
© OMRON Corporation 2007-2022
All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. J117-E1-18
1122(0207)
8