Omron-Electronics-G2RV-1-SI-DC21
| Part # | Omron-Electronics-G2RV-1-SI-DC21 |
| Download | Omron-Electronics-G2RV-1-SI-DC21 |
New Product
Slim I/O Relay
G2RV-SR/G3RV-SR
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay
• Realized about 25% lower profile than conventional
products, contributing to further miniaturization of the
control panel.
• Push-In Plus technology are used to save wiring work in
comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with
traditional screw terminals.)
For the recent information on models that have been certified
for safety standards, refer to your OMRON website.
• No screw loosening means maintenance-free application,
realizing high reliability
• ‘Hand-free’ structure that holds an inserted flat-blade
screwdriver to achieve easier wiring work for stranded
wires.
• Screw terminal is also stocked to meet the screw type
needs.
• Mounted relay or solid-state relay has a plug-in terminal
that is difficult to bend at the time of exchange.
*
According to OMRON actual measurement data from November 2015.
Refer to
Safety Precautions
on page 20.
Slim I/O Relay Types
G2RV-SR series
mounted relay: electromagnetic relay …..
.
f
rom page 2
G3RV-SR series
mounted relay: solid state relay ……………
.
f
rom page 10
Common matter
Common precaution
s
.
……………………………………………………..
.
f
rom page 20
Common accessories (order separately)…………………………..
.
f
rom page 25
1
Slim I/O Relay
G2RV-SR
Global standard size, low profile slim
I/O relay with width 6.2 mm
• Realized about 25% lower profile than conventional
products, contributing to further miniaturization of the
control panel.
• Realized opening and closing ability with one pole 6 A slim
shape.
• Micro load products for one pole 50 mA using Au-plated
contacts for small load switching also available.
• Since G2RV is a transparent case, confirming the state of
the contact with the naked eye is possible, and easy to
confirm abnormality on-site (installed location).
• Screw terminal is also stocked to meet the screw type
needs.
For the recent information on models that have been certified
for safety standards, refer to your OMRON website.
• Mounted relay uses plug-in terminals that are difficult to
bend when exchanging.
• G3RV-SR featuring a solid state relay similar in shape to G2RV-SR also available.
Refer to
Safety Precautions
on page 20.
Features
With latching lever
(
T
est switch)
Push-In Plus technology
Standard model/Micro load
Terminal x 5
• Push-in
• Screw
Short bar insertion holes
Protective cover
(Released state)
Operation
Release hole
display LED
(Socket section)
Release lever
Protective cover
(Locked condition)
Latching lever
(
T
est switch)
Terminal (insertion) hole
Latching lever
(
T
est switch)
• Circuit check operation
Confirmation, reducing the inspection effort
Mechanical
indicator
• Operation
verification
which is linked
to the contact
PAT
“Foreign matter intrusion prevention structure”
“Malfunction prevention stopper”
Transparent case
Relay contact
Easy confirmation
of the situation
Release lever
Relay easily
fixed/removed
90
mm
Plug-in terminal
Peace of mind as the
terminal does not bend
when replacing
80
mm
2
G2RV-SR
Model Number Structure
Model Number Legend
G2RV-SR
@@ @
–
@ @
(1)
(2) (3)
(4) (5) (6)
(1) Basic model name
G2RV: Slim I/O Relay
(3) Terminal (wire connection)
50: Push-In Plus Terminal
70: Screw terminal
(5) Contact structure
Blank: Standard
AP: Microloads
(2) Sub type
(6) Rated input voltage
12, 24 VDC
24, 48 VAC/VC
SR: Slim relay + integrated low profile socket
(4) Latching lever (test switch)
0: Without latching lever
1: With latching lever
100, 110, 200, 230 VAC
Ordering Information
Terminal
Latching lever
(Test switch)
Classification
(Wire connection)
Rated input voltage (V)
Model
12
G2RV-SR500 DC12
DC
24
G2RV-SR500 DC24
24
G2RV-SR500 AC/DC24
G2RV-SR500 AC/DC48
G2RV-SR500 AC100
AC/DC
48
No
100
Standard
110
G2RV-SR500 AC110
AC
200
G2RV-SR500 AC200
230
G2RV-SR500 AC230
DC
24
G2RV-SR501 DC24
Push-In Plus
Yes
Terminal
AC/DC
24
G2RV-SR501 AC/DC24
G2RV-SR500-AP DC12
G2RV-SR500-AP DC24
G2RV-SR500-AP AC/DC24
G2RV-SR500-AP AC/DC48
G2RV-SR500-AP AC100
G2RV-SR500-AP AC110
G2RV-SR500-AP AC200
G2RV-SR500-AP AC230
G2RV-SR700 DC12
12
DC
24
24
AC/DC
48
Microloads
No
100
110
200
230
12
AC
DC
24
G2RV-SR700 DC24
24
G2RV-SR700 AC/DC24
G2RV-SR700 AC/DC48
G2RV-SR700 AC100
AC/DC
48
No
100
110
200
230
24
Standard
G2RV-SR700 AC110
AC
G2RV-SR700 AC200
G2RV-SR700 AC230
DC
G2RV-SR701 DC24
Screw terminal
Yes
AC/DC
24
G2RV-SR701 AC/DC24
G2RV-SR700-AP DC12
G2RV-SR700-AP DC24
G2RV-SR700-AP AC/DC24
G2RV-SR700-AP AC/DC48
G2RV-SR700-AP AC100
G2RV-SR700-AP AC110
G2RV-SR700-AP AC200
G2RV-SR700-AP AC230
12
DC
24
24
AC/DC
48
Microloads
No
100
110
200
230
AC
Note:
Sockets are not sold individually.
3
G2RV-SR
Relay for Maintenance
Model Number Legend
G2RV-1-SI-G
G2RV-1-S(-AP)-G
G2RV-1 – S
@
–
@
– G
@
(1) (2)
(3) (4) (5) (6)
(1) No. of poles
1: 1 pole
(4) Contact material
Blank: Ag alloy
AP: Ag alloy + Au plating
(2) Terminal
S: plug-in
(5) Types of relay for exchange
G: G2RV-SR series equipped
Relay
(3) Latching lever (Test switch)
Blank: Without latching lever
I: With latching lever
(6) Rated coil voltage
Number: 11, 21, 48 VDC
List of Models
Latching
Lever
(Test switch)
Rated coil
voltage (V)
Type
Model
Applicable model
11
G2RV-1-S-G DC11
G2RV-1-S-G DC21
G2RV-SR700/500 DC12V
G2RV-SR700/500 DC24V
G2RV-SR700/500 AC/DC24V
G2RV-SR700/500 AC/DC48V
G2RV-SR700/500 AC100V
G2RV-SR700/500 AC110V
G2RV-SR700/500 AC200V
G2RV-SR700/500 AC230V
G2RV-SR701/501 DC24V
G2RV-SR701/501 AC/DC24V
G2RV-SR700/500-AP DC12V
G2RV-SR700/500-AP DC24V
21
48
No
DC
DC
DC
Standard
G2RV-1-S-G DC48
Yes
21
11
21
G2RV-1-SI-G DC21
G2RV-1-S-AP-G DC11
G2RV-1-S-AP-G DC21
G2RV-SR700/500-AP AC/DC24V
G2RV-SR700/500-AP AC/DC48V
G2RV-SR700/500-AP AC100V
G2RV-SR700/500-AP AC110V
G2RV-SR700/500-AP AC200V
G2RV-SR700/500-AP AC230V
Microload
No
48
G2RV-1-S-AP-G DC48
Note:
Voltage is reduced within the socket for the slim I/O relay, so the rated input voltage and rated coil voltage of replacement relays are different.
Accessories (order separately)
Refer to page 25 for G2RV-SR/G3VR-SR Common Accessories.
4
G2RV-SR
Specifications
Ratings
Coil ratings
Must operate
voltage
Must release
voltage
Maximum
allowable voltage
Rated current
Power consumption
Rated input
voltage
AC
Percentage of the
rated voltage
DC
Percentage of the rated voltage
AC (VA)
DC (mW)
50 Hz
60 Hz
12 VDC
–
–
–
–
27.9 mA
–
–
Approx. 300 mW
Approx. 300 mW
24 VDC
13.5 mA
24 VAC/VDC
48 VAC/VDC
100 VAC
110 VAC
200 VAC
230 VAC
12.5 mA
12.6 mA
12.6 mA
Approx. 0.5 VA
Approx. 300 mW
Approx. 0.4 VA
Approx. 250 mW
5.9 mA
5.9 mA
5.9 mA
6.6 mA
7.3 mA
6.1 mA
6.0 mA
5.9 mA
7.6 mA
8.4 mA
5.2 mA
80% max.*
10% min.
110%
–
–
–
–
Approx. 0.8 VA
Approx. 0.8 VA
Approx. 1.7 VA
Approx. 1.7 VA
–
–
–
–
Note:
The operating characteristics are measured at ambient temperature of 23°C.
*
Operating voltage will be, for mounting in the upside down direction, 85% max.
(Upside down: Direction in which the mechanical indicator faces down)
Contact ratings
Item
Standard (G2RV-SR700, 500, 701, 501)
For microloads
(G2RV-SR700-AP, 500-AP) *2
Contact configuration
SPDT
Resistive load
(cos
φ
=1)
Inductive load
(cos
φ
=0.4, L/R=7ms)
Resistive load
(cos
φ
=1)
Load
6 A at 250 VAC
6 A at 30 VDC
2.5 A at 250 VAC
2 A at 30 VDC
50 mA at 30 VAC
50 mA at 36 VDC
Rated load
Rated carry current
6 A
50 mA
Maximum switching voltage
Maximum switching current
440 VAC, 125 VDC
6 A
30 VAC, 36 VDC
50 mA
1,500 VA
180 W
500 VA
60 W
Maximum switching power
–
Failure rate P value
(reference value) *1
10 mA at 5 VDC
1 mA at 100 mVDC
*1.
P level:
λ
60
=0.1×10
-6
/times
This value is the value in switching frequency 120 operations/min.
*2.
If the Au plating layer is destroyed, the number will be the same as the standard type.
Characteristics
Item
Contact resistance *
Operate (Set) time *
Standard (G2RV-SR700, 500, 701, 501)
100 m
Ω
max.
For microloads
(G2RV-SR700-AP, 500-AP)
20 ms max.
AC, AC/DC: 40 ms max.
DC: 20 ms max.
Release time *
Mechanical: 18,000 operations/h
Electrical: 1,800 operations/h (rated load)
Maximum operating frequency
Insulation resistance
1,000 M
Ω
min. (at 500 VDC)
Between coil and contacts: 4,000VAC 50/60 Hz 1 min
Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min
Dielectric strength
Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Vibration resistance
Shock resistance
Destruction: 1,000 m/s
2
Malfunction: Energized 200m/s
2
, Non-energized 100m/s
2
Mechanical
5,000,000 operations min.
Endurance *
NO contact: 70,000 operations min.
5,000,000 operations min.
Electrical
NC contact: 50,000 operations min.
Ambient operating temperature
Operating: –40 to +55°C (with no icing or condensation)
Ambient operating humidity
Weight
Operating: 5 to 85% RH
Approx. 30 g
Contact material
Ag alloy
Ag alloy + Au plating
Note:
Above values are initial values.
*
Value is at ambient temperature of 23°C.
5
G2RV-SR
Approved standards
UL508 (file No.E41643)
Model
Contact form
Operation coil ratings
Contact ratings
Operations
6 A at 250 VAC (Resistive load)
6 A at 30 VDC (Resistive load)
2 A at 400 VAC (Resistive load)*
12 to 48 VDC
24 to 230 VAC
G2RV-SR series
SPDT
6,000
* If
the load voltage exceeds 250 VAC, please attach with a spacing
of 12 mm min., or use a separate plate (XW5Z-EP12).
12 mm 12 mm 12 mm
TÜV (EN 61810-1)
Model
Contact form
SPDT
Operation coil ratings
12, 24 VDC
Contact ratings
Operations
6 A at 250 VAC (Resistive load)
50,000
6 A at 30 VDC (Resistive load)
50,000
G2RV-SR series
24, 48 VAC/VDC
100, 110, 200, 230 VAC
2 A at 400 VAC (Resistive load)*
6,000
* If
the load voltage exceeds 250 VAC, please attach with a spacing
of 12 mm min., or use a separate plate (XW5Z-EP12).
12 mm 12 mm 12 mm
Lloyd’s (File No.07/10020)
Model
Contact form
Operation coil ratings
Contact ratings
6 A at 250 VAC (Resistive load)
2.5 A at 250 VAC (PF0.4)
6 A at 30 VAC (Ress)
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
G2RV-SR500
G2RV-SR700
SPDT
2 A at 30 VDC (L/R=7ms)
6 A at 250 VAC (Resistive load)
2.5 A at 250 VAC (PF0.4)
6 A at 30 VAC (Ress)
G2RV-SR501
G2RV-SR701
12, 24 VDC
24 VAC/VDC
SPDT
SPDT
2 A at 30 VDC (L/R=7ms)
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
G2RV-SR500-AP
G2RV-SR700-AP
0.05 A at 30 VAC (Resistive load)
0.05 A at 36 VDC (Resistive load)
Engineering Data
Endurance curve (N.O. side)
Switching capacity of DC resistive load
10.0
1000
30 VDC resistive load
250 VAC resistive load
1.0
100
30 VDC
inductive load
250 VAC
inductive
load
10
0
0.1
2
4
6
20
60
100
140
180
220
Opening and closing current (A)
DC switching voltage (V)
6
G2RV-SR
Dimensions
(unit: mm)
Slim I/O Relay + socket
Push-In Plus Terminal Block
Models without latching lever (without test switch)
G2RV-SR500
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
78 max.
G2RV-SR500-AP
(+)
Input circuit
A1
A2
G2RV
(–)
3.4
74.5
74.1
Other voltage
35.25
18.78
Input circuit
(5.05)
A1
A2
G2RV
12
14
11
78.77
35.3
90 max.
24 VDC
(+)
A1
Input circuit
12
14
A2
(–)
G2RV
11
: Diode bridge
(5.05)
: Light emitting diode
18.78
35.25
51.72
59.71
6.2 max.
12
14
11
Models with latching lever (with test switch)
G2RV-SR501
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
81 max.
(+)
A1
Input circuit
A2
(–)
G2RV
3.4
77.5
74.1
Other voltage
Input circuit
A1
35.25
18.78
(5.05)
A2
G2RV
12
14
11
78.77
24 VDC
35.3
90 max.
(+)
A1
Input circuit
12
14
A2
(–)
G2RV
11
: Diode bridge
(5.05)
: Light emitting diode
18.78
35.25
51.72
59.71
6.2 max.
12
14
11
7
G2RV-SR
Screw terminal
Models without latching lever (without test switch)
G2RV-SR700
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
G2RV-SR700-AP
12 VDC
Input circuit
(+)
A1
78 max.
A2
(–)
G2RV
3.4
74.5
74.1
Other voltage
35.18
18.71
Input circuit
A1
(5.05)
A2
G2RV
12
14
11
78.77
35.3
90 max.
24 VDC
(+)
Input circuit
A1
12
14
A2
(–)
G2RV
11
: Diode bridge
(5.05)
18.71
35.18
51.65
56.2
: Light emitting diode
6.2 max.
12
14
11
Models with latching lever (with test switch)
G2RV-SR701
Terminal Arrangement/Internal Connection Diagram
(TOP VIEW)
12 VDC
(+)
A1
Input circuit
81 max.
A2
(–)
G2RV
3.4
77.5
74.1
Other voltage
Input circuit
A1
35.18
18.71
(5.05)
A2
G2RV
12
14
11
78.77
24 VDC
35.3
90 max.
(+)
A1
Input circuit
12
14
A2
(–)
G2RV
11
: Diode bridge
(5.05)
18.71
35.18
51.65
56.2
: Light emitting diode
6.2 max.
12
14
11
8
G2RV-SR
Relay for maintenance
Models without latching lever
G2RV-1-S-G
G2RV-1-S-AP-G
5.2 max.
30.5 max.
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
33 max.
(Input circuit)
16.2
12
A1 A2
14 11
1.8
0.5
2.4
3.5
5.04
5.04
22
3
Models with latching lever (test switch)
G2RV-1-SI-G
5.2 max.
30.5 max.
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
(Input circuit)
36 max.
12
A1 A2
14 11
16.2
0.5
1.8
2.4
3.5
5.04
5.04
22
3
9
Slim I/O Solid State Relay
G3RV-SR
Global standard size, low profile type
slim I/O solid state relay with width
6.2 mm.
• Realized about 25% lower profile than conventional products,
contributing to further miniaturization of the control panel.
• Optimal slim, high frequency, high-speed opening and closing
SSR (solid state relay).
• Realized a slim shape with a switching capacity up to
3 A (DC), and 2 A (AC).
• Because MOSFET is used for the outlet element for the DC
load, opening and closing load of 100
μ
A to 3 A is possible.
• Check operating status at a glance at the operating display
LED.
For the recent information on models that have been certified
for safety standards, refer to your OMRON website.
• Mounted I/O SSR (solid-state relay) uses plug-in terminals that
are difficult to bend when exchanging.
• G2RV-SR featuring a general-purpose relay similar in shape to G3RV-SR also available.
Refer to
Safety Precautions
on page 20.
Features
Push-In Plus technology
Terminal x 5
• Push-in
• Screw
Short bar insertion holes
Release hole
Operation display LED
(Socket section)
Release lever
Operation
display LED
(SSR section)
Terminal (insertion) hole
Release lever
Relay easily
fixed/removed
90
mm
Plug-in terminal
Peace of mind as the terminal
does not bend when replacing
80
mm
10
G3RV-SR
Model Number Structure
Model Number Legend
G3RV-SR
@ @ @
–
@ @
(1)
(2)
(3)
(4) (5)
(1) Basic model name
G3RV: Slim I/O Solid State Relay
(4) Output voltage specification
: AC output (triac) zero cross function available
AL :
AC output (triac) zero cross function not available
: DC output (MOS FET)
A
(2) Sub type
D
SR: Slim solid relay + integrated low profile socket
(5) Rated voltage input
12, 24 VDC
24, 48 VAC/VDC
(3) Terminal (wire connection)
500: Push-In Plus Terminal
700: Screw terminal
100, 110, 200, 230 VAC
11
G3RV-SR
Ordering Information
Terminal
(wire connection)
Applicable
output load
Zero cross
function
Rated input voltage
(V)
Model
12
G3RV-SR500-D DC12
G3RV-SR500-D DC24
G3RV-SR500-D AC/DC24
G3RV-SR500-D AC/DC48
G3RV-SR500-D AC100
G3RV-SR500-D AC110
G3RV-SR500-D AC200
G3RV-SR500-D AC230
G3RV-SR500-A DC12
G3RV-SR500-A DC24
G3RV-SR500-A AC/DC24
G3RV-SR500-A AC/DC48
G3RV-SR500-A AC100
G3RV-SR500-A AC110
G3RV-SR500-A AC200
G3RV-SR500-A AC230
G3RV-SR500-AL DC12
G3RV-SR500-AL DC24
G3RV-SR500-AL AC/DC24
G3RV-SR500-AL AC/DC48
G3RV-SR500-AL AC100
G3RV-SR500-AL AC110
G3RV-SR500-AL AC200
G3RV-SR500-AL AC230
G3RV-SR700-D DC12
G3RV-SR700-D DC24
G3RV-SR700-D AC/DC24
G3RV-SR700-D AC/DC48
G3RV-SR700-D AC100
G3RV-SR700-D AC110
G3RV-SR700-D AC200
G3RV-SR700-D AC230
G3RV-SR700-A DC12
G3RV-SR700-A DC24
G3RV-SR700-A AC/DC24
G3RV-SR700-A AC/DC48
G3RV-SR700-A AC100
G3RV-SR700-A AC110
G3RV-SR700-A AC200
G3RV-SR700-A AC230
G3RV-SR700-AL DC12
G3RV-SR700-AL DC24
G3RV-SR700-AL AC/DC24
G3RV-SR700-AL AC/DC48
G3RV-SR700-AL AC100
G3RV-SR700-AL AC110
G3RV-SR700-AL AC200
G3RV-SR700-AL AC230
DC
24
24
AC/DC
48
DC load
AC load
DC load
AC load
—
Yes
No
—
100
110
AC
200
230
12
DC
24
24
AC/DC
48
Push-In Plus Terminal
100
110
AC
200
230
12
DC
24
24
AC/DC
48
100
110
AC
200
230
12
DC
24
24
AC/DC
48
100
110
AC
200
230
12
DC
24
24
AC/DC
48
Screw terminal
Yes
100
110
AC
200
230
12
DC
24
24
AC/DC
48
No
100
110
AC
200
230
Note:
Sockets are not sold individually.
12
G3RV-SR
Solid state relay for maintenance
Model Number Legend
G3RV-
@ @
S
@ @
(1) (2) (3) (4)
(5)
(1) Output voltage
specification
D: DC output
(3) Terminal
S: Plug-in type
(4) Zero cross functions
2: AC output
Blank: Zero cross function available
L: Zero cross function not available
(2) Rated current
02: AC output 2 A
03: DC output 3 A
(5) Rated input voltage
Number: 12, 24, 48 VDC
List of Models
Rated
output
Load *
Rated input
voltage
(socket)
Insulation
Operation
Output Zero
cross
Model
Applicable model
method
Display
(SSR)
Function
12 VDC
G3RV-202S DC12
G3RV-202S DC24
G3RV-SR700/500-A DC12V
G3RV-SR700/500-A DC24V
24 VDC
24 VAC/VDC
48 VAC/VDC
100 VAC
110 VAC
200 VAC
230 VAC
12 VDC
G3RV-SR700/500-A AC/DC24V
G3RV-SR700/500-A AC/DC48V
G3RV-SR700/500-A AC100V
G3RV-SR700/500-A AC110V
G3RV-SR700/500-A AC200V
G3RV-SR700/500-A AC230V
G3RV-SR700/500-AL DC12V
G3RV-SR700/500-AL DC24V
G3RV-SR700/500-AL AC/DC24V
G3RV-SR700/500-AL AC/DC48V
G3RV-SR700/500-AL AC100V
G3RV-SR700/500-AL AC110V
G3RV-SR700/500-AL AC200V
G3RV-SR700/500-AL AC230V
G3RV-SR700/500-D DC12V
G3RV-SR700/500-D DC24V
G3RV-SR700/500-D AC/DC24V
G3RV-SR700/500-D AC/DC48V
G3RV-SR700/500-D AC100V
G3RV-SR700/500-D AC110V
G3RV-SR700/500-D AC200V
G3RV-SR700/500-D AC230V
Yes
G3RV-202S DC48
2 A
(at 100 to
240
Photo-
triac
AC
G3RV-202SL DC12
G3RV-202SL DC24
VAC)
24 VDC
24 VAC/VDC
48 VAC/VDC
100 VAC
110 VAC
200 VAC
230 VAC
12 VDC
Yes
(green)
No
G3RV-202SL DC48
G3RV-D03SL DC12
G3RV-D03SL DC24
24 VDC
24 VAC/VDC
48 VAC/VDC
100 VAC
110 VAC
200 VAC
230 VAC
Photo-
voltage
coupler
3 A
(at 5 to
24 VDC)
DC
–
G3RV-D03SL DC48
*
Different depending on the ambient temperature.
For more details, refer to
Load current vs. ambient rated temperature
on page 16.
Accessories (order separately)
Refer to page 25 for G2RV-SR/G3VR-SR Common Accessories.
13
G3RV-SR
Specifications
Rating (ambient temperature 25°C)
Input
G3RV-SR700/500-A series
Rated current
Input voltage
Rated input
voltage
Must operate
Must release
voltage
AC
Percentage of the
rated voltage
voltage
DC
50 Hz
60 Hz
12 VDC
–
–
–
15.0 mA
12.0 mA
10.8 V max.
21.6 V max.
21.6 V max.
43.2 V max.
90 V max.
24 VDC
–
24 VAC/VDC
48 VAC/VDC
100 VAC
11.3 mA
11.4 mA
11.0 mA
6.8 mA
6.2 mA
6.2 mA
6.7 mA
7.5 mA
6.9 mA
6.2 mA
6.2 mA
7.9 mA
8.8 mA
6.0 mA
1 V min.
±10%
–
–
–
–
110 VAC
99 V max.
200 VAC
180 V max.
207 V max.
230 VAC
G3RV-SR700/500-AL series
Rated current
AC
Input voltage
Rated input
voltage
Must operate
voltage
Must release
voltage
Percentage of the
rated voltage
DC
50 Hz
60 Hz
12 VDC
–
–
–
15.0 mA
12.0 mA
10.8 V max.
21.6 V max.
21.6 V max.
43.2 V max.
90 V max.
24 VDC
–
24 VAC/VDC
48 VAC/VDC
100 VAC
11.4 mA
11.5 mA
11.0 mA
7.7 mA
7.3 mA
7.3 mA
7.0 mA
7.7 mA
7.7 mA
7.3 mA
7.3 mA
8.1 mA
8.9 mA
6.9 mA
1 V min.
±10%
–
–
–
–
110 VAC
99 V max.
200 VAC
180 V max.
207 V max.
230 VAC
G3RV-SR700/500-D series
Rated current
AC
Input voltage
Rated input
voltage
Must operate
voltage
Must release
voltage
Percentage of the
rated voltage
DC
50 Hz
60 Hz
12 VDC
–
–
–
8.0 mA
10.8 V max.
21.6 V max.
21.6 V max.
43.2 V max.
90 V max.
24 VDC
–
4.6 mA
24 VAC/VDC
48 VAC/VDC
100 VAC
5.0 mA
6.8 mA
6.2 mA
6.2 mA
6.7 mA
7.5 mA
5.1 mA
6.9 mA
6.2 mA
6.2 mA
7.9 mA
8.8 mA
4.3 mA
6.0 mA
1 V min.
±10%
–
–
–
–
110 VAC
99 V max.
200 VAC
180 V max.
207 V max.
230 VAC
Output
Item
G3RV-SR700/500-A(L)
100 to 240 VAC (50/60 Hz)
G3RV-SR700/500-D
Rated load voltage
Load voltage range
Load current
5 to 24 VDC
75 to 264 VAC (50/60 Hz)
3 to 26.4 VDC
0.1 to 2 A (Ambient temperature=25°C)
100
μ
A to 3 A (Ambient temperature=25°C)
Inrush current resistance
30 A (60 Hz, 1 cycle)
30 A (60 Hz, 1 cycle)
Permissible l
2
t; Joule integral value
(reference value)
15A
2
s
9 A
2
s
400 W
72 W
Applied load capacity
(Output voltage: 200 VAC)
(Output voltage: 24 VDC)
14
G3RV-SR
Characteristics
Item
G3RV-SR700/500-A
G3RV-SR700/500-AL
3 ms max.
60 ms max.
G3RV-SR700/500-D
6 ms max.
60 ms max.
1/2 cycle of load power supply
+1 ms max.
Operate time
Release time
60 ms max.
Output ON voltage drop
Output ON resistance
Leaked current
1.6 V (RMS) max.
–
–
0.3
Ω
max. (at 24 VDC)
5 mA max. (at 200 VAC, 50/60 Hz)
10 µA max. (at 24 VDC)
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
100 M
Ω
min. (at 500 VDC)
Between input and output 2,500 VAC 50/60 Hz 1 min
Malfunction: 10 to 55 to 10 Hz double amplitude 0.70 mm
300m/s
2
Storage: –30 to +100°C (with no icing or no condensation)
Operating: –30 to +55°C (with no icing or no condensation)
Ambient operating temperature
Ambient operating humidity
Weight
45 to 85% RH
Approx. 38 g
2
Pollution degree
The degree of protection by
IEC60529
IP20
Rated impulse dielectric
strength
4.0 kV/
III
Load category
LC-A
DC-12
1.5Ie 1.1Ue
5s ON, 10s OFF, 10 cycles
Overload current profile
Rated insulation voltage
240 V
Approved standards
UL 508 (file No.E64562)
Model
Input ratings
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
Contact ratings
24 VDC 3 A (resistive load) at 25°C
G3RV-SR700/500-D series
G3RV-SR700/500-A(L) series
12, 24 VDC
24, 48 VAC/DC
240 VAC 2 A (resistive load) at 25°C
100, 110, 200, 230 VAC
TÜV(EN 62314)
Model
Input ratings
Contact ratings
12, 24 VDC
G3RV-SR700/500-D series
G3RV-SR700/500-A(L) series
24, 48 VAC/VDC
100, 110, 200, 230 VAC
24 VDC 3 A (resistive load)
12, 24 VDC
24, 48 VAC/VDC
100, 110, 200, 230 VAC
240 VAC 2 A (resistive load)
15
G3RV-SR
Engineering Data
Load current vs. ambient rated temperature
G3RV-SR700/500-A(L) series
Product mounting spacing 10 mm (Separate Mounting)
Close mounting (up to 5 units *)
5
5
4
3
2
4
3
2
1
1
0
0.2
0
−30 −20
−30 −20
0
20 25
40 55
60
80
100
0
20 25
40 55
60
80
100
Ambient temperature (°C)
Ambient temperature (°C)
G3RV-SR700/500-D series
Product mounting spacing 10 mm (Separate Mounting)
Close mounting (up to 5 units *)
5
5
4
3
2
4
3
2
1
1
0
0.5
0
−30 −20
0
20 25
40 55
60
80
100
−30 −20
0
20 25
40 55
60
80
100
Ambient temperature (°C)
Ambient temperature (°C)
*
When five or more are installed, install with 10 mm space between
each.
For details, please refer to
Mounting
on page 23.
Inrush Current Resistance: Non-repetitive
Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively.
G3RV-SR700/500-A(L) series
G3RV-SR700/500-D series
40
40
35
30
35
30
25
20
15
10
5
25
20
15
10
5
0
0
10
30 50
100
300 500
1,000 3,000
5,000
Energized time (ms)
10
30 50
100
300 500
1,000 3,000
5,000
Energized time (ms)
16
G3RV-SR
Dimensions
(unit: mm)
Solid state relay + socket
Push-In Plus Terminal Block
G3RV-SR500
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
12 VDC
Input circuit
(+)
A1
78 max.
G3RV
A2
(–)
A2–
INPUT
3.4
74.5
74.1
A1+
13 (+)
35.25
18.78
OUTPUT
14 (–)
(5.05)
12
14
The information in
parentheses in for
a DC
out
put.
13
78.77
35.3
90 max.
24 VDC
(+)
Input circuit
A1
G3RV
A2
(–)
A2–
INPUT
A1+
(5.05)
18.78
35.25
51.72
59.71
6.2 max.
13 (+)
OUTPUT
14 (–)
12
14
The information in
parentheses in for
a DC
out
put.
13
Other voltage
Input circuit
A1
A2
G3RV
A2–
INPUT
A1+
13 (+)
OUTPUT
14 (–)
12
14
The information in
parentheses in for
a DC
out
put.
13
: Diode bridge
: Light emitting diode
17
G3RV-SR
Screw terminal
G3RV-SR700
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
12 VDC
78 max.
Input circuit
(+)
A1
3.4
74.5
74.1
G3RV
A2
(–)
35.18
18.71
A2–
INPUT
(5.05)
A1+
13 (+)
OUTPUT
14 (–)
12
14
The information in
parentheses in for
a DC
out
put.
78.77
35.3
90 max.
13
24 VDC
(+)
A1
Input circuit
(5.05)
18.71
35.18
51.65
56.2
G3RV
A2
(–)
6.2 max.
A2–
INPUT
A1+
13 (+)
OUTPUT
14 (–)
12
14
The information in
parentheses in for
a DC
out
put.
13
Other voltage
Input circuit
A1
A2
G3RV
A2–
INPUT
A1+
13 (+)
OUTPUT
14 (–)
12
14
The information in
parentheses in for
a DC
out
put.
13
: Diode bridge
: Light emitting diode
18
G3RV-SR
Solid state relay for maintenance
Terminal Arrangement/
Internal Connection Diagram
(TOP VIEW)
G3RV-D03SL
G3RV-202S(L)
G3RV-D03SL (input circuit)
Input
30.5 max.
Load
33 max.
15.8
14 13
G3RV-202S(L) (input circuit)
Input
A1 A2
1.8
3.5
2.4
22
3
5.04
5.2 max.
Load
14 13
A1 A2
19
G2RV-SR/G3RV-SR
Safety Precautions
Be sure to read the
Safety Precautions for All Relays
in the website at the following URL:
Format of Warning Indications
WARNING
Indicates a potentially hazardous situation
which, if not avoided, will result in minor or
Ensure that the socket is not charged during wiring and
maintenance. Not doing so may result in electric shock.
moderate injury, or may result in serious
injury or death. Additionally, there may be
significant property damage.
WARNING
Do not touch the terminal section of the G2RV-SR or the
surrounding area while the power is being supplied.
Doing so may result in electric shock.
Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury or in property damage.
CAUTION
Indicates supplementary comments on
what to do or avoid doing, to use the
product safety.
Precautions
for Safe Use
CAUTION
Minor electrical shock may occasionally occur.
Do not touch the G3RV terminal section (i.e., current
carrying parts) while the power is being supplied.
Includes operating precautions to ensure
that the product will operate properly and
that performance and functions will not be
adversely affected.
Precautions
for Correct
Use
The G3RV may rupture if short-circuit current flows.
As protection against accidents due to short-circuiting,
be sure to install protective devices, such as fuses and
no-fuse breakers, on the power supply side.
Meaning of Graphic Symbols for Ensuring Product Safety
Indicates the possibility of electric shock under
specific conditions.
Minor electrical shock may occasionally occur.
Do not touch the main circuit terminals on the G3RV
immediately after the power supply has been turned
OFF.
Shock may result due to the electrical charge stored
in the built-in snubber circuit.
Used for general CAUTION, WARNING, or
DANGER precautions for which there is no
specified symbol. (This symbol is also used as
the alerting symbol, but shall not be used in this
meaning on the product.)
Indicates the possibility of explosion or rupture
under specific conditions.
Note: G3RV-202S(L), G3RV-SR500/700-A(L) series
models only
Minor burns may occasionally occur.
Indicates the possibility of injuries by high
temperature under specific conditions.
Do not touch the G3RV or the heat sink while the
power is being supplied or immediately after the
power supply has been turned OFF.
The G3RV becomes extremely hot.
Provide a space of at least 3 mm between the G2RV-
SR and ground. Not doing so may result in a ground
fault.
20
G2RV-SR/G3RV-SR
Precautions for Safe Use
Transport
• Do
not use the product if it has been dropped on the ground.
Dropping the product may adversely affect performance.
• Do
not drop the product or subject it to abnormal vibration or shock
during transportation or mounting. Doing so may result in
deterioration of performance, malfunction, or failure.
• Do
not transport the product without it being packaged. Doing so
may result in damage, malfunction, or failure.
Usage
• Please
select the load within the rated range. Doing so may result
in damage, malfunction, or failure.
• Do
not transport the G3RV under the following conditions. Doing
so may result in damage, malfunction, or deterioration of
performance characteristics.
• Please
use the power of the rated frequency. It may cause
malfunction, failure, or risk of burnout.
<G3RV>
• High
temperature, high humidity conditions
• Install
G3RV according to instructions
Mounting
on page 23. If you
• Conditions
such as temperature change that causes rapid
condensation
install in the wrong direction, abnormal heat is generated, and may
lead to short-circuiting or burning the output element.
• G3RV
is an SSR that generates heat. Please observe the ambient
temperature setting range of G3RV. If installing in an enclosed
space, set a fan, and ventilate.
• Condition
where it is not packaged
Operating and Storage Environments
• Do
not use or store the product in the following locations. Doing so
may result in damage, malfunction, or deterioration of performance
characteristics.
• When
mounting G3RV to DIN rail, firmly fits into the groove. If it is
not properly installed, there is a risk of it falling.
• Do
not store in locations subject to ambient storage
temperatures outside the range –40 to 70°C (for G2RV) and
outside the range –30 to 100°C (for G3RV).
Wiring
•
For the current to be applied, make sure a wire size with margin is used.
Otherwise, excessive heat generated by the wires may cause burning
.
• Locations
subject to relative humidity outside the range 5% to
85% (for G2RV) and outside the range 45% to 85% (for G3RV).
• Locations
subject to high temperature or high humidity.
• Conditions
such as temperature change that causes rapid
condensation
• Do
not attempt to use the wire if the coat is torn. Not doing so may
result in electric shock.
• Always
turn OFF the power supply before performing wiring. Not
doing so may cause electrical shock.
<G3RV>
• L
ocations where corrosive gases or flammable gases are present
• Location
where rainwater or water droplets gets splashed
• Location
with splashes of water, oil, and chemicals, etc.
• Locations
with much dust, salt, and iron powder
• Location
with blockers
• The
wires of the socket for G3RV socket should not be passed
through the same duct as that being connected to the high-voltage
power supply. Otherwise, inductive noise may damage the G3RV
or cause it to malfunction.
• Where
static electricity or noise occurs
Push-In Plus Terminal Block
• Do
not wire anything to the release holes.
• Where
strong electromagnetic field is generated
• Where
there is a risk of exposure to radioactivity
• Do
not use or store Sockets in environments that contain silicone
gas, sulfidizing gas (e.g., SO
2
or H
2
S), or organic gas, or near
materials that contain silicone. Doing so may cause the contacts to
be unstable or to fail.
•
Do not tilt or twist a flat-blade screwdriver while it is inserted into a release
hole on the terminal block. The terminal block may be damaged
.
• Insert
a flat-blade screwdriver into the release holes at an angle.
The terminal block may be damaged if you insert the screwdriver
straight in.
• Do
not allow the flat-blade screwdriver to fall out while it is inserted
into a release hole.
Handling <G3RV>
• Keep
the G3RV well ventilated.
There is a risk of short-circuiting or burning due to G3RV
overheating.
•
Do not bend the wire past its natural bending radius or pull on it
with excessive force. Doing so may cause the wire disconnection.
•
Do not insert more than one wire into each terminal (insertion) hole
.
Mounting
• To
prevent wiring materials from smoking or ignition, confirm wire
ratings and use the wiring materials given in the following table.
• Before
you start wiring, please make sure that the socket is
securely attached to the mounting rail. If the socket is unstable, it
may come loose and risk of injury towards the workers.
Stripping length
Recommended Wire
(Ferrules not used)
•
Please insert the flat-blade screwdriver to the bottom of the hole. If
you do not insert the flat-blade screwdriver correctly, the cable will
0.5 to 1.5 mm
2
/AWG20 to AWG16
8 mm
Disposal
not be connected correctly
.
• When
disposing of the product, do not put into the fire.
• When
lubricant such as oil is attached to the tip of the driver, the
driver will fall off, with a risk of injury towards the workers.
• Do
not tilt the G2RV-SR/G3RV-SR after mounting to the support
rail. Doing so may apply excessive force to the mounting portion,
possibly damaging the product. Attach end plates (PFP-M) to
sandwich the product and hold it in place.
21
G2RV-SR/G3RV-SR
Precautions for Correct Use
• Do
not use or store the product in the following locations. Doing so
may result in damage, malfunction, or deterioration of performance
characteristics.
• When
replacing relays, there is a possibility the relay will pop out
and fall. Take care to prevent the relay from falling during
replacement.
• Where
vibration or shock is directly transmitted to the body
• Where
the socket could come into contact with a solvent or
alkaline agent
Push-In Plus Terminal Block
1. Connecting Wires to the Push-In Plus Terminal Block
Part Names of the Terminal Block
• Insert
the short bar into the insertion hole in the correct orientation,
and insert until all terminals are all the way in.
• If
using a short bar, install the short bar before performing wiring
work.
Release hole
T
e
rminal (Insertion) hole
• A
push-in Plus terminal block type and a screw terminal type have
different insertion positions, so a mixed installation using the same
short bar is not possible.
Connecting Wires with Ferrules and Solid Wires
Insert the solid wire or ferrule straight into the terminal block until the
end strikes the terminal block.
Orient correctly
and push all the
way in.
Release hole
T
e
rminal
(Insertion) hole
Ferrules or
solid wire
Completely inserted
• If
a wire is difficult to connect because it is too thin, use a flat-blade
screwdriver in the same way as when connecting stranded wire.
All terminals are inserted all the way in.
Connecting Stranded Wires
Use the following procedure to connect the wires to the terminal block.
(1) Hold a flat-blade screwdriver at an angle and insert it into the
release hole.
The angle should be between 10°and15°. If the flat-blade
screwdriver is inserted correctly, you will feel the spring in the
release hole.
(2) With the flat-blade screwdriver still inserted into the release hole,
insert the wire into the terminal hole until it strikes the terminal
block.
(3) Remove the flat-blade screwdriver from the release hole.
Flat-blade screwdriver
(3)
(1)
Incomplete insertion
All terminals are not inserted
all the way in.
Incorrect installation
Some terminals not inserted
completel
y
.
10 to 15°
(3)
(1)
(2)
Stranded Wires
Incomplete
insertion
Checking Connections
• After
the insertion, pull gently on the wire to make sure that it will
not come off and the wire is securely fastened to the terminal block.
• If
you use a ferrule with a conductor length of 10 mm, part of the
conductor may be visible after the ferrule is inserted into the
terminal block, but the product insulation distance will still be
satisfied.
• Do
not insert short bar in the hole for wire or screw driver, it may
cause the result of failure of pull out.
2. Removing Wires from the Push-In Plus Terminal Block
Use the following procedure to remove wires from the terminal block.
The same method is used to remove stranded wires, solid wires, and
ferrules.
(1) Hold a flat-blade screwdriver at an angle and insert it into the
release hole.
If insert short bar in the hole for wire or screw driver and try to pull
out, it may cause damage for short bar or socket and failure in
electric conductivity.
• Please
insert P2RVC terminal into the short bar insertion hole of
G2RV-SR/G3RV-SR. If insert P2RVC into the release hole or
terminal (insertion) hole wrongly, P2RVC may stuck and can not
remove and it may cause result of damage on P2RVC and G2RV-
SR/G3RV-SR.
(2) With the flat-blade screwdriver still inserted into the release hole,
remove the wire from the terminal insertion hole.
(3) Remove the flat-blade screwdriver from the release hole.
Flat-blade screwdriver
(3)
(1)
10 to 15°
Wire
(3)
Please turn off the power of input and output side and remove PLC
interface unit when replacing mounting relays and SSRs for
maintenance.
(1)
(2)
22
G2RV-SR/G3RV-SR
3. Recommended ferrules and Crimp Tools
Recommended ferrules
Recommended Flat-blade Screwdriver
Use a flat-blade screwdriver to connect and remove wires.
Use the following flat-blade screwdriver.
The following table shows manufacturers and models as of 2015/Dec.
Applicable
wire
Stripping
length
(mm)
(Ferrules
used)
Ferrules
Conduct
length
Recommended ferrules
Side
Front
Phoeni
x
C
ontact
Weidmuller
Wago
product
(mm
2
)
(AWG)
(mm)
product
product
2.5 mm dia.
8
10
8
10
12
10
12
10
12
10
12
10
12
10
12
AI 0,25-8
AI 0,25-10
AI 0,34-8
AI 0,34-10
AI 0,5-8
H0.25/12 216-301
— —
H0.34/12 216-302
0.25
0.34
0.5
24
22
20
18
0.4 mm
2.5 mm
10
8
—
—
H0.5/14
H0.5/16
216-201
216-241
Model
Manufacturer
10
8
AI 0,5-10
AI 0,75-8
AI 0,75-10
AI 1-8
ESD 0,40×2,5
SZS 0,4×2,5
SZF 0-0,4×2,5
*
0.4×2.5×75 302
AEF.2,5×75
Wera
H0.75/14 216-202
H0.75/16 216-242
Phoenix Contact
0.75
10
8
Wiha
H1.0/14
H1.0/16
H1.5/14
H1.5/16
216-203
216-243
216-204
216-244
Facom
Wago
1/1.25 18/17
1.25/1.5
17/16
10
8
AI 1-10
210-719
AI 1,5-8
SDI 0.4×2.5×75
Weidmuller
10
AI 1,5-10
*
OMRON’s exclusive purchase model XW4Z-00B is available to
order as SZF 0-0
,
4×2
,
5 (manufactured by Phoenix Contact).
CRIMPFOX6
Recommended crimp tool
CRIMPFOX6T-F
PZ6 roto
CRIMPFOX10S
Variocrimp4
Screw Terminal
• Screw terminal
Note: 1.
Make sure that the outer diameter of the wire is smaller than
the inner diameter of the insulating sleeve of the
recommended ferrule.
Applicable wire
size
Stripping
length
Wired type
2.
Make sure that the ferrule processing dimensions conform
to the following figure.
Stranded wires, without
ferrule
0.5 to 1.5 mm
2
0.5 to 1.5 mm
2
8 mm
Stranded wires, with ferrule
and plastic collar
8 mm
8 to 10 mm
Stranded wires with ferrule,
without plastic collar
0.5 to 1.5 mm
2
0.5 to 1.5 mm
2
8 mm
8 mm
2.6 mm max.
1.9 mm max.
Single wire
3.
If you use AWG24 to AWG22 (0.25 to 0.34 mm
2
) wires, UL
certification will not apply.
• Tightening Torque
0.4 N • m
• Electric wiring
Use the electric wire of specified size as shown above. The length
of the that is not covered is 8 mm.
Screw terminal
8 mm
Stripping length
<G2RV>
Operating latching lever (test switch)
When operating the latching lever for G2RV-SR701/501
series, use a 2.5 mm width flat-blade screwdriver.
• Applicable
flat-blade screwdriver
Flat-blade screwdriver with parallel cutting edge: shaft diameter
2.5 mm (3.0 mm max.)
Parallel cutting edge flat-blade screwdriver
Shaft diameter 2.5 mm (3.0 mm max.)
Wide flat-blade screwdriver
Driver with a thick shaft cannot be used.
• Always
turn OFF the power supply before operating latching lever.
• Return
to its original state after using the latching lever.
23
G2RV-SR/G3RV-SR
• Do
not use the latching lever as a switch.
<Relationship of SSR and duct (duct depth)>
• Operation
durability of the latching lever is 100 times or more.
• Do
not keep the latching lever ON for a long period of time (24
hours or more) in order to maintain the operation check function.
Incorrect Example
Countermeasure 1
Recommended height of the duct is
1/2 or less of the height of the SSR
Countermeasure 2
Duct or other object
blocking airflow
Duct or other object
blocking airflow
Duct or
Method of operation of the latching lever (test
switch)
other object
blocking
airflow
Airflow
Height of SSR
<Protective cover: locked>
<Protective cover: disengage>
Contact normal position
Vertical
Direction
Metal
base
SSR
SSR
Contact operating position (on-state)
SSR
Close protective cover
Open protective cover
Duct or other object
blocking airflow
Duct or other object
blocking airflow
Duct or other object
blocking airflow
Do not enclose the SSR in a
duct of the same height.
It will interfere with the heat
dissipation of SSR.
Use ducts that have a
shallow depth, to provide a
place the SSR on a metal base so
sufficient ventilation area.
that it is not surrounded by the ducts.
If the ducts cannot be made lower,
<Ventilation Outside the Control Panel>
Be aware of airflow
Duct or other object
blocking airflow
Exhaust
(Axial fan)
Keep the protective cover open when using the latching lever. Move
until the latching lever clicks to the ON position (ON state). After use
latching lever, in order to prevent malfunction, return the switch to
contact normal position (OFF state), and make sure the protective
cover is firmly closed.
SSR
SSR
SSR
Using the latching lever
Example: check the operation of the relay and the sequence circuit
Inlet
<G3RV>
• If
the air inlet or air outlet has a filter, clean the filter regularly to
prevent it from clogging to ensure an efficient flow of air.
• Do
not place objects that may obstruct the proper ventilation for
outside or inside the inlet or exhaust port, and in the outside
vicinity.
• Since
the G3RV uses electronic components, do not allow it to fall,
vibrate, or apply shock that exceeds the criteria. Doing so may
result in failure, malfunction, or deterioration of performance.
• Tighten
screw terminal for G3RV at torque 0.4 N · m. It may cause
short-circuit failure or burning.
• A
heat exchanger, if used, should be located in front of the G3RV
to ensure the efficiency of the heat exchanger.
• Please
use the voltage and current suitable for the input and
output terminal portion of G3RV. It may cause short-circuit failure
or burning.
• Please
observe the ambient temperature of G3RV. The rated
current of the G3RV is measured at an ambient temperature of
25°C.
Mounting
• The
G3RV uses a semiconductor in the output element.
This causes the temperature inside the control panel to increase
due to heating resulting from the flow of electrical current through
the load. The G3RV reliability can be increased by adding a
ventilation fan to the control panel to dispel this heat, thus lowering
the ambient temperature of the G3RV.
<The SSR Mounting Pitch (Panel Mounting)>
Duct or other object blocking airflow
60 mm min.
10 mm min.
SSR
(It suggests that life expectancy is doubled by each 10°C reduction
in ambient temperature.)
Vertical Direction
EMI
The G3RV is a Class A product (for industrial environments). When
used in a residential environment, it may cause radio interference.
In such case, the user may be required to take appropriate
measures.
30 mm min.
80 mm min.
*
When five or more are installed, install with 10 mm space between
each.
24
G2RV-SR/G3RV-SR
For G2RV-SR/G3VR-SR
Common Accessories (order separately)
Ordering Information
Short Bars
No. of
poles
Minimum order
(Quantity)
Maximum energizing
current
Appearance
Pitch
Colors
Model *
2
PYDN-6.2-020
@
PYDN-6.2-030
@
PYDN-6.2-040
@
PYDN-6.2-100
@
PYDN-6.2-200
@
3
Red (R),
Blue (S),
Yellow (Y)
6.2 mm
4
10
32 A
10
20
Note:
Use for wiring to the adjacent socket.
*
Replace the box (
@
) in the model number with the code for the covering color.
@
color selection: R = red, S = blue, Y = yellow
Label
Minimum order (Sheet)
(Pieces per sheet)
Appearance
Model
XW5Z-P2.5LB1
*
5
(1 sheet/72 pieces)
XW5Z-P2.5LB2
*
Available following June 2017 production.
Separate Plate
Appearance
Model
XW5Z-EP12
PLC interface unit
Appearance
I/O classification
Connection method
Common process
Applicable Models
*
G2RV-SR500-AP
Model
P2RVC-8-I-5-1
P2RVC-8-I-5
PNP
NPN
PNP
PNP
NPN
Push-In
Screw
For input
G2RV-SR700-AP
P2RVC-8-I-7-1
P2RVC-8-O-5-1
P2RVC-8-O-5
G2RV-SR500
G2RV-SR501
G3RV-SR500
Push-In
For output
G2RV-SR700
G2RV-SR701
G3RV-SR700
Screw
PNP
P2RVC-8-O-7-1
*
Please make sure applicable models, P2RVC can not be used other combination than the above table.
Parts for DIN Track Mounting
Minimum order
(Quantity)
Appearance
Type
Model
1 m
PFP-100N
PFP-50N
DIN Tracks
1
0.5 m
End Plate
*
PFP-M
PFP-S
10
Spacer
*
When mounting DIN Track, please use End Plate (PFP-M).
Refer to your OMRON website for details on PFP-
@
.
25
G2RV-SR/G3RV-SR
Applicable Cables
Cable
length L
(mm)
Name
Appearance
Connecting Cables
Applicable Connectors
1,000
2,000
3,000
5,000
P2RV-A100C
P2RV-A200C
P2RV-A300C
P2RV-A500C
End A
Device
end
End B
PLC interface
unit end
Cables with Loose
8 I/O
Wires
Various devices
points
P2RV-A
@
C
L
70
P2RV-4-100C
1,000
2,000
3,000
5,000
1,000
2,000
3,000
5,000
1,000
2,000
3,000
5,000
P2RV-4-200C
Cables with
32 output
PLC I/O Units with MIL connectors (1:4)
CJ1W-OD232/OD262, etc.
Connectors (1:4)
points
P2RV-4-
@
C
P2RV-4-300C
P2RV-4-500C
L
L
L
300
300
300
P2RV-4-100IMC
P2RV-4-200IMC
P2RV-4-300IMC
P2RV-4-500IMC
P2RV-4-100IFC
P2RV-4-200IFC
P2RV-4-300IFC
P2RV-4-500IFC
Cables with
32 input
PLC I/O Units with MIL connectors (1:4)
CJ1W-ID232/ID262, etc.
Connectors (1:4)
points
P2RV-4-
@
IMC
Cables with
32 input
PLC I/O Units with Fujitsu connectors (1:4)
CJ1W-ID231/ID261, etc.
Connectors (1:4)
points
P2RV-4-
@
IFC
P2RV-A050C-OMR GRT1
P2RV-A100C-OMR GRT1
P2RV-A050IC-OMR GRT1
P2RV-A100IC-OMR GRT1
P2RV-A050C-OMR NX
P2RV-A100C-OMR NX
P2RV-A050IC-OMR NX
P2RV-A100IC-OMR NX
500
1,000
500
8 output
Cables with Connectors
points
(1:1)
Slice I/O Units (1:1)
For inputs: GRT1-ID8-1
For outputs: GRT1-OD8-1
P2RV-A
@
C-OMR GRT1
8 input
L
points
1,000
500
Removable
terminal block
8 output
PLC I/O Units with screw-less clamp
terminal block (1:1)
For inputs: NX-ID4442
points
Cables with
1,000
500
Connectors (1:1)
P2RV-A
@
C-OMR NX
8 input
For outputs: NX-OD4256
points
L
1,000
26
G2RV-SR/G3RV-SR
Cable
length L
(mm)
Name
Appearance
Connecting Cables
Applicable Connectors
P2RV-050C-SCH-A
P2RV-100C-SCH-A
P2RV-200C-SCH-A
P2RV-300C-SCH-A
P2RV-500C-SCH-A
P2RV-050C-SCH-B
P2RV-100C-SCH-B
P2RV-200C-SCH-B
P2RV-300C-SCH-B
P2RV-500C-SCH-B
P2RV-050C-SCH-C
P2RV-100C-SCH-C
P2RV-200C-SCH-C
P2RV-300C-SCH-C
P2RV-500C-SCH-C
P2RV-050C-SCH-D
P2RV-100C-SCH-D
P2RV-200C-SCH-D
P2RV-300C-SCH-D
P2RV-500C-SCH-D
P2RV-050C-SIM-A
P2RV-100C-SIM-A
P2RV-200C-SIM-A
P2RV-300C-SIM-A
P2RV-500C-SIM-A
P2RV-050C-SIM-B
P2RV-100C-SIM-B
P2RV-200C-SIM-B
P2RV-300C-SIM-B
P2RV-500C-SIM-B
500
End A
De
v
ice
end
End B
PLC interface
1,000
2,000
3,000
5,000
500
32 input
points
u
nit end
Schneider Electric PLCs with 32-point
connectors (1:4)
For inputs: 140 DDI 353 00
For outputs: 140 DDO 353 00
1,000
2,000
3,000
5,000
500
32 output
points
Schneider Electric
PLC Connecting
Cables
L
300
P2RV-
@
C-SCH-
@
1,000
2,000
3,000
5,000
500
16 input
points
Schneider Electric PLCs with
16-point connectors (1:2)
For inputs: BMX DDI 1602
For outputs: BMX DDO 1602
1,000
2,000
3,000
5,000
500
16 output
points
L
300
1,000
2,000
3,000
5,000
500
32 input
points
Siemens PLCs with
32-point connectors (1:4)
For inputs: 6ES7 321-1BL00-0AA0
For outputs: 6ES7 322-1BL00-0AA0
1,000
2,000
3,000
5,000
32 output
points
L
L
L
300
300
300
P2RV-050C-SIM-C
P2RV-100C-SIM-C
P2RV-200C-SIM-C
P2RV-300C-SIM-C
P2RV-500C-SIM-C
500
1,000
2,000
3,000
5,000
Siemens PLC
Connecting Cables
P2RV-
@
C-SIM-
@
Siemens PLCs with
16-point connectors (1:2)
For inputs: 6ES7 321-1BH02-0AA0
16 input
points
P2RV-050C-SIM-D
P2RV-100C-SIM-D
P2RV-200C-SIM-D
P2RV-300C-SIM-D
P2RV-500C-SIM-D
P2RV-050C-SIM-E
P2RV-100C-SIM-E
P2RV-200C-SIM-E
P2RV-300C-SIM-E
P2RV-500C-SIM-E
500
1,000
2,000
3,000
5,000
500
32 input
points
Siemens PLCs with
32-point connectors (1:4)
For inputs: 6ES7 421-1BL-0AA0
For outputs: 6ES7 422-1BL-0AA0
1,000
2,000
3,000
5,000
32 output
points
27
G2RV-SR/G3RV-SR
PLC interface unit
Ratings / characteristices
Rated voltage
30 VAC/DC
Rated current
0.5 A/poles, 2 A/unit
Ambient operating temperature
−
40 to 55°C
Destruction
10 to 55 to 10 Hz, single amplitude 0.75 mm (double amplitude 1.5 mm)
Vibration resistance
Shock resistance
Malfunction
Destruction
Malfunction
10 to 55 to 10 Hz, single amplitude 0.75 mm (double amplitude 1.5 mm)
300 m/s
2
100 m/s
2
Electrical schematic
Input
P2RVC-8-I-
@
-1 (PNP)
P2RVC-8-I-5 (NPN)
1………………..8
1………………..8
14
14
11
11
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
Output
P2RVC-8-O-
@
-1 (PNP)
P2RVC-8-O-5 (NPN)
1………………..8
1………………..8
A2
A2
A1
A1
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
28
G2RV-SR/G3RV-SR
Dimensions
(unit: mm)
PLC interface unit
Push-I
N
P2RVC-8-I-5(-1)
P2RVC-8-O-5(-1)
49.60
67.16
12.68
7×6.20
29
Screw
P2RVC-8-I-7-1
P2RVC-8-O-7-1
49.60
67.16
12.68
7×6.20
29
29
G2RV-SR/G3RV-SR
(Except for PLC interface unit)
Common Accessories (order separately)
Dimensions
(unit: mm)
Short Bars
PYDN-6.2-
@@
(6.2 mm)
Maximum carry
Pitch
No. of poles
L (Length)
Colors
Model
*
current
2
3
12.4
18.6
24.8
62
PYDN-6.2-020
@
PYDN-6.2-030
@
PYDN-6.2-040
@
PYDN-6.2-100
@
PYDN-6.2-200
@
2
1.20
9
L
Red (R)
Blue (S)
Yellow (Y)
6.2 mm
4
32 A
14
10
20
124
6.20
Note:
Use the Short Bars for crossover wiring within one Socket or between Sockets.
*
Replace the box (
@
) in the model number with the code for the covering color.
Separate Plate
XW5Z-EP12
12
56
63
Parts for DIN Track Mounting
Refer to your OMRON website for details on the PFP-
@
.
Safety Precautions
Precautions for Correct Use
When mounting a short bar
• Intermediate
pins can be bent by a tool or by hand and cut off for use.
Mounting a separate plate
• Use
a flat-blade screwdriver to tighten the center top screw and
secure the plate. Loosen the screw to remove the plate from the
DIN rail.
M4 Screw
Bend
Cut off
• The
short bar can be cut to as many poles as needed. Insert the
tool from the plastic part side, and cut along the groove in the
plastic part between the terminals. When cutting, take care not to
break or deform the terminals.
However, because the metal on the cut surface will be exposed,
insulation countermeasures between adjacent products must be
ensured. Such countermeasures include widening the intervals
between products or using XW5Z-EP12 separate plates (order
separately).
Cut
30
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warrant
y
.
O
mron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESEN
T
A
T
ION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMEN
T
,
M
ERCHAN
T
A
BILITY OR FITNESS FOR A
P
A
RTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES TH
A
T
I
T ALONE HAS DETERMINED TH
A
T
T
HE PRODUCTS WILL
SUI
T
A
B
L
Y
M
EET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remed
y
.
O
mron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warrant
y
,
r
epair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warrant
y
.
Limitation on Liability; Etc.
OMRON COM
P
A
NIES SHALL NOT BE LIABLE FOR SPECIAL, INDIREC
T
,
I
NCIDEN
T
A
L, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY W
A
Y
C
ONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRAC
T
, WARRANT
Y
,
N
EGLIGENCE OR STRICT LIABILIT
Y
.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLIC
A
T
ION INVO
L
V
ING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING TH
A
T
T
HE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND TH
A
T
T
HE OMRON PRODUCT(S) IS PROPER
L
Y
R
A
T
ED AND INS
T
A
LLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warrant
y
.
I
t may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liabilit
y
.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
OMRON Corporation
Kyoto, JAPAN
Industrial Automation Company
Authorized Distributor:
Regional Headquarters
OMRON EUROPE B.
V
.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
OMRON ELECTRONICS LLC
2895 Greenspoint Parkwa
y
,
S
uite 200
Hoffman Estates, IL 60169 U.S.A.
T
e
l: (31)2356-81-300/Fax: (31)2356-81-388
T
e
l: (1) 847-843-7900/Fax: (1) 847-843-7787
© OMRON Corporation 2016-2017
All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China
T
o
wer,
200 Yin Cheng Zhong Road,
OMRON ASIA
P
ACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra
T
e
chnopark,
PuDong New Area, Shanghai, 200120, China
T
e
l: (86) 21-5037-2222/Fax: (86) 21-5037-2200
CSM_
6
_
4
_
12
17
Cat. No. J214-E1-02
Singapore 119967
T
e
l: (65) 6835-3011/Fax: (65) 6835-2711
0617(0316)