Omron-Electronics-G2RV-1SG-DC21

Part #Omron-Electronics-G2RV-1SG-DC21
Download 
Omron-Electronics-G2RV-1SG-DC21
New Product  
Slim I/O Relay  
G2RV-SR/G3RV-SR  
Global standard size,  
low profile slim I/O relay with width 6.2 mm,  
slim I/O solid state relay  
• Realized about 25% lower profile than conventional  
products, contributing to further miniaturization of the  
control panel.  
• Push-In Plus technology are used to save wiring work in  
comparison with conventional screw terminals.  
(Wiring time is reduced by 60%* in comparison with  
traditional screw terminals.)  
For the recent information on models that have been certified  
for safety standards, refer to your OMRON website.  
• No screw loosening means maintenance-free application,  
realizing high reliability  
• ‘Hand-free’ structure that holds an inserted flat-blade  
screwdriver to achieve easier wiring work for stranded  
wires.  
• Screw terminal is also stocked to meet the screw type  
needs.  
• Mounted relay or solid-state relay has a plug-in terminal  
that is difficult to bend at the time of exchange.  
*
According to OMRON actual measurement data from November 2015.  
Refer to
Safety Precautions
on page 20.  
Slim I/O Relay Types  
G2RV-SR series
 
mounted relay: electromagnetic relay …..
.
f
rom page 2  
G3RV-SR series
 
mounted relay: solid state relay ……………
.
f
rom page 10  
Common matter  
Common precaution
s
.
……………………………………………………..
.
f
rom page 20  
Common accessories (order separately)…………………………..
.
f
rom page 25  
1

Slim I/O Relay  
G2RV-SR  
Global standard size, low profile slim  
I/O relay with width 6.2 mm  
• Realized about 25% lower profile than conventional  
products, contributing to further miniaturization of the  
control panel.  
• Realized opening and closing ability with one pole 6 A slim  
shape.  
• Micro load products for one pole 50 mA using Au-plated  
contacts for small load switching also available.  
• Since G2RV is a transparent case, confirming the state of  
the contact with the naked eye is possible, and easy to  
confirm abnormality on-site (installed location).  
• Screw terminal is also stocked to meet the screw type  
needs.  
For the recent information on models that have been certified  
for safety standards, refer to your OMRON website.  
• Mounted relay uses plug-in terminals that are difficult to  
bend when exchanging.  
• G3RV-SR featuring a solid state relay similar in shape to G2RV-SR also available.  
Refer to
Safety Precautions
on page 20.  
Features  
With latching lever  
(
T
est switch)  
Push-In Plus technology  
Standard model/Micro load  
Terminal x 5  
• Push-in  
• Screw  
Short bar insertion holes  
Protective cover  
(Released state)  
Operation  
Release hole  
display LED  
(Socket section)  
Release lever  
Protective cover  
(Locked condition)  
Latching lever  
(
T
est switch)  
Terminal (insertion) hole  
Latching lever  
(
T
est switch)  
• Circuit check operation  
Confirmation, reducing the inspection effort  
Mechanical  
indicator  
• Operation  
verification  
which is linked  
to the contact  
PAT  
“Foreign matter intrusion prevention structure”  
“Malfunction prevention stopper”  
Transparent case  
Relay contact  
Easy confirmation  
of the situation  
Release lever  
Relay easily  
fixed/removed  
90
mm  
Plug-in terminal  
Peace of mind as the  
terminal does not bend  
when replacing  
80
mm  
2

G2RV-SR  
Model Number Structure  
Model Number Legend  
G2RV-SR
@@ @
–
@ @  
(1)  
(2) (3)
 
(4) (5) (6)  
(1) Basic model name  
G2RV: Slim I/O Relay  
(3) Terminal (wire connection)  
50: Push-In Plus Terminal  
70: Screw terminal  
(5) Contact structure  
Blank: Standard  
AP: Microloads  
(2) Sub type  
(6) Rated input voltage  
12, 24 VDC  
24, 48 VAC/VC  
SR: Slim relay + integrated low profile socket  
(4) Latching lever (test switch)  
0: Without latching lever  
1: With latching lever  
100, 110, 200, 230 VAC  
Ordering Information  
Terminal  
Latching lever  
(Test switch)  
Classification  
(Wire connection)  
Rated input voltage (V)  
Model  
12  
G2RV-SR500 DC12  
DC  
24  
G2RV-SR500 DC24  
24  
G2RV-SR500 AC/DC24  
G2RV-SR500 AC/DC48  
G2RV-SR500 AC100  
AC/DC  
48  
No  
100  
Standard  
110  
G2RV-SR500 AC110  
AC  
200  
G2RV-SR500 AC200  
230  
G2RV-SR500 AC230  
DC  
24  
G2RV-SR501 DC24  
Push-In Plus  
Yes  
Terminal  
AC/DC  
24  
G2RV-SR501 AC/DC24  
G2RV-SR500-AP DC12  
G2RV-SR500-AP DC24  
G2RV-SR500-AP AC/DC24  
G2RV-SR500-AP AC/DC48  
G2RV-SR500-AP AC100  
G2RV-SR500-AP AC110  
G2RV-SR500-AP AC200  
G2RV-SR500-AP AC230  
G2RV-SR700 DC12  
12  
DC  
24  
24  
AC/DC  
48  
Microloads  
No  
100  
110  
200  
230  
12  
AC  
DC  
24  
G2RV-SR700 DC24  
24  
G2RV-SR700 AC/DC24  
G2RV-SR700 AC/DC48  
G2RV-SR700 AC100  
AC/DC  
48  
No  
100  
110  
200  
230  
24  
Standard  
G2RV-SR700 AC110  
AC  
G2RV-SR700 AC200  
G2RV-SR700 AC230  
DC  
G2RV-SR701 DC24  
Screw terminal  
Yes  
AC/DC  
24  
G2RV-SR701 AC/DC24  
G2RV-SR700-AP DC12  
G2RV-SR700-AP DC24  
G2RV-SR700-AP AC/DC24  
G2RV-SR700-AP AC/DC48  
G2RV-SR700-AP AC100  
G2RV-SR700-AP AC110  
G2RV-SR700-AP AC200  
G2RV-SR700-AP AC230  
12  
DC  
24  
24  
AC/DC  
48  
Microloads  
No  
100  
110  
200  
230  
AC  
Note:
Sockets are not sold individually.  
3

G2RV-SR  
Relay for Maintenance  
Model Number Legend  
G2RV-1-SI-G  
G2RV-1-S(-AP)-G  
G2RV-1 – S
@
–
@
– G
 
@  
(1) (2)
 
(3) (4) (5) (6)  
(1) No. of poles  
1: 1 pole  
(4) Contact material  
Blank: Ag alloy  
AP: Ag alloy + Au plating  
(2) Terminal  
S: plug-in  
(5) Types of relay for exchange  
G: G2RV-SR series equipped  
Relay  
(3) Latching lever (Test switch)  
Blank: Without latching lever  
I: With latching lever  
(6) Rated coil voltage  
Number: 11, 21, 48 VDC  
List of Models  
Latching  
Lever  
(Test switch)  
Rated coil  
voltage (V)  
Type  
Model  
Applicable model  
11  
G2RV-1-S-G DC11  
G2RV-1-S-G DC21  
G2RV-SR700/500 DC12V  
G2RV-SR700/500 DC24V  
G2RV-SR700/500 AC/DC24V  
G2RV-SR700/500 AC/DC48V  
G2RV-SR700/500 AC100V  
G2RV-SR700/500 AC110V  
G2RV-SR700/500 AC200V  
G2RV-SR700/500 AC230V  
G2RV-SR701/501 DC24V  
G2RV-SR701/501 AC/DC24V  
G2RV-SR700/500-AP DC12V  
G2RV-SR700/500-AP DC24V  
21  
48  
No  
DC  
DC  
DC  
Standard  
G2RV-1-S-G DC48  
Yes  
21  
11  
21  
G2RV-1-SI-G DC21  
G2RV-1-S-AP-G DC11  
G2RV-1-S-AP-G DC21  
G2RV-SR700/500-AP AC/DC24V  
G2RV-SR700/500-AP AC/DC48V  
G2RV-SR700/500-AP AC100V  
G2RV-SR700/500-AP AC110V  
G2RV-SR700/500-AP AC200V  
G2RV-SR700/500-AP AC230V  
Microload
No  
48  
G2RV-1-S-AP-G DC48  
Note:
Voltage is reduced within the socket for the slim I/O relay, so the rated input voltage and rated coil voltage of replacement relays are different.  
Accessories (order separately)  
Refer to page 25 for G2RV-SR/G3VR-SR Common Accessories.  
4

G2RV-SR  
Specifications  
Ratings  
Coil ratings  
Must operate  
voltage  
Must release  
voltage  
Maximum  
allowable voltage  
Rated current  
Power consumption  
Rated input  
voltage  
AC  
Percentage of the  
rated voltage  
DC  
Percentage of the rated voltage  
AC (VA)  
DC (mW)  
50 Hz  
60 Hz  
12 VDC  
–
–
–
–
27.9 mA  
–
–
Approx. 300 mW  
Approx. 300 mW  
24 VDC  
13.5 mA  
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
110 VAC  
200 VAC  
230 VAC  
12.5 mA
 
12.6 mA  
12.6 mA  
Approx. 0.5 VA
 
Approx. 300 mW  
Approx. 0.4 VA
 
Approx. 250 mW  
5.9 mA  
5.9 mA  
5.9 mA  
6.6 mA  
7.3 mA  
6.1 mA  
6.0 mA  
5.9 mA  
7.6 mA  
8.4 mA  
5.2 mA  
80% max.*  
10% min.  
110%  
–
–
–
–
Approx. 0.8 VA  
Approx. 0.8 VA  
Approx. 1.7 VA  
Approx. 1.7 VA  
–
–
–
–
Note:
The operating characteristics are measured at ambient temperature of 23°C.  
*
Operating voltage will be, for mounting in the upside down direction, 85% max.  
(Upside down: Direction in which the mechanical indicator faces down)  
Contact ratings  
Item  
Standard (G2RV-SR700, 500, 701, 501)  
For microloads
 
(G2RV-SR700-AP, 500-AP) *2  
Contact configuration  
SPDT  
Resistive load  
(cos
φ
=1)  
Inductive load  
(cos
φ
=0.4, L/R=7ms)  
Resistive load  
(cos
φ
=1)  
Load  
6 A at 250 VAC  
6 A at 30 VDC  
2.5 A at 250 VAC  
2 A at 30 VDC  
50 mA at 30 VAC  
50 mA at 36 VDC  
Rated load  
Rated carry current  
6 A  
50 mA  
Maximum switching voltage  
Maximum switching current  
440 VAC, 125 VDC  
6 A  
30 VAC, 36 VDC  
50 mA  
1,500 VA  
180 W  
500 VA  
60 W  
Maximum switching power  
–
Failure rate P value  
(reference value) *1  
10 mA at 5 VDC  
1 mA at 100 mVDC  
*1.
P level:
λ
60
=0.1×10

-6

/times  
This value is the value in switching frequency 120 operations/min.  
*2.
If the Au plating layer is destroyed, the number will be the same as the standard type.  
Characteristics  
Item  
Contact resistance *  
Operate (Set) time *  
Standard (G2RV-SR700, 500, 701, 501)  
100 m
Ω
max.  
For microloads
 
(G2RV-SR700-AP, 500-AP)  
20 ms max.  
AC, AC/DC: 40 ms max.  
DC: 20 ms max.  
Release time *  
Mechanical: 18,000 operations/h  
Electrical: 1,800 operations/h (rated load)  
Maximum operating frequency  
Insulation resistance  
1,000 M
Ω
min. (at 500 VDC)  
Between coil and contacts: 4,000VAC 50/60 Hz 1 min  
Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min  
Dielectric strength  
Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)  
Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)  
Vibration resistance  
Shock resistance  
Destruction: 1,000 m/s

2  

Malfunction: Energized 200m/s

2

, Non-energized 100m/s

2  

Mechanical
5,000,000 operations min.  
Endurance *  
NO contact: 70,000 operations min.  
5,000,000 operations min.  
Electrical  
NC contact: 50,000 operations min.  
Ambient operating temperature
 
Operating: –40 to +55°C (with no icing or condensation)  
Ambient operating humidity  
Weight  
Operating: 5 to 85% RH  
Approx. 30 g  
Contact material  
Ag alloy  
Ag alloy + Au plating  
Note:
Above values are initial values.  
*
Value is at ambient temperature of 23°C.  
5

G2RV-SR  
Approved standards  
UL508 (file No.E41643)  
Model  
Contact form  
Operation coil ratings  
Contact ratings  
Operations  
6 A at 250 VAC (Resistive load)  
6 A at 30 VDC (Resistive load)  
2 A at 400 VAC (Resistive load)*  
12 to 48 VDC  
24 to 230 VAC  
G2RV-SR series  
SPDT  
6,000  
* If
 
the load voltage exceeds 250 VAC, please attach with a spacing  
of 12 mm min., or use a separate plate (XW5Z-EP12).  
12 mm 12 mm 12 mm  
TÜV (EN 61810-1)  
Model  
Contact form  
SPDT  
Operation coil ratings  
12, 24 VDC  
Contact ratings  
Operations  
6 A at 250 VAC (Resistive load)
 
50,000  
6 A at 30 VDC (Resistive load)
 
50,000  
G2RV-SR series  
24, 48 VAC/VDC  
100, 110, 200, 230 VAC  
2 A at 400 VAC (Resistive load)*
 
6,000  
* If
 
the load voltage exceeds 250 VAC, please attach with a spacing  
of 12 mm min., or use a separate plate (XW5Z-EP12).  
12 mm 12 mm 12 mm  
Lloyd’s (File No.07/10020)  
Model  
Contact form  
Operation coil ratings  
Contact ratings  
6 A at 250 VAC (Resistive load)  
2.5 A at 250 VAC (PF0.4)  
6 A at 30 VAC (Ress)  
12, 24 VDC  
24, 48 VAC/VDC  
100, 110, 200, 230 VAC  
G2RV-SR500  
G2RV-SR700  
SPDT  
2 A at 30 VDC (L/R=7ms)  
6 A at 250 VAC (Resistive load)  
2.5 A at 250 VAC (PF0.4)  
6 A at 30 VAC (Ress)  
G2RV-SR501  
G2RV-SR701  
12, 24 VDC  
24 VAC/VDC  
SPDT  
SPDT  
2 A at 30 VDC (L/R=7ms)  
12, 24 VDC  
24, 48 VAC/VDC  
100, 110, 200, 230 VAC  
G2RV-SR500-AP  
G2RV-SR700-AP  
0.05 A at 30 VAC (Resistive load)  
0.05 A at 36 VDC (Resistive load)  
Engineering Data  
Endurance curve (N.O. side)  
Switching capacity of DC resistive load  
10.0  
1000  
30 VDC resistive load  
250 VAC resistive load  
1.0  
100  
30 VDC  
inductive load  
250 VAC
inductive
load  
10  
0
0.1  
2
4
6
20  
60  
100  
140  
180  
220  
Opening and closing current (A)  
DC switching voltage (V)  
6

G2RV-SR  
Dimensions  
(unit: mm)  
Slim I/O Relay + socket  
Push-In Plus Terminal Block  
Models without latching lever (without test switch)  
G2RV-SR500  
Terminal Arrangement/Internal Connection Diagram  
(TOP VIEW)  
12 VDC  
78 max.  
G2RV-SR500-AP  
(+)
Input circuit  
A1  
A2  
G2RV  
(–)  
3.4  
74.5  
74.1  
Other voltage  
35.25  
18.78  
Input circuit  
(5.05)  
A1  
A2  
G2RV  
12  
14  
11  
78.77  
35.3  
90 max.  
24 VDC  
(+)  
A1  
Input circuit  
12  
14  
A2  
(–)  
G2RV  
11  
: Diode bridge  
(5.05)  
: Light emitting diode  
18.78  
35.25  
51.72  
59.71  
6.2 max.  
12  
14  
11  
Models with latching lever (with test switch)  
G2RV-SR501  
Terminal Arrangement/Internal Connection Diagram  
(TOP VIEW)  
12 VDC  
81 max.  
(+)  
A1  
Input circuit  
A2  
(–)  
G2RV  
3.4  
77.5  
74.1  
Other voltage  
Input circuit  
A1  
35.25  
18.78  
(5.05)  
A2  
G2RV  
12  
14  
11  
78.77  
24 VDC  
35.3  
90 max.  
(+)  
A1  
Input circuit  
12  
14  
A2  
(–)  
G2RV  
11  
: Diode bridge  
(5.05)  
: Light emitting diode  
18.78  
35.25  
51.72  
59.71  
6.2 max.  
12  
14  
11  
7

G2RV-SR  
Screw terminal  
Models without latching lever (without test switch)  
G2RV-SR700  
Terminal Arrangement/Internal Connection Diagram  
(TOP VIEW)  
G2RV-SR700-AP  
12 VDC  
Input circuit  
(+)  
A1  
78 max.  
A2  
(–)  
G2RV  
3.4  
74.5  
74.1  
Other voltage  
35.18  
18.71  
Input circuit  
A1  
(5.05)  
A2  
G2RV  
12  
14  
11  
78.77  
35.3  
90 max.  
24 VDC  
(+)
Input circuit  
A1  
12  
14  
A2  
(–)  
G2RV  
11  
: Diode bridge  
(5.05)  
18.71  
35.18  
51.65  
56.2  
: Light emitting diode  
6.2 max.  
12  
14  
11  
Models with latching lever (with test switch)  
G2RV-SR701  
Terminal Arrangement/Internal Connection Diagram  
(TOP VIEW)  
12 VDC  
(+)  
A1  
Input circuit  
81 max.  
A2  
(–)  
G2RV  
3.4  
77.5  
74.1  
Other voltage  
Input circuit  
A1  
35.18  
18.71  
(5.05)  
A2  
G2RV  
12  
14  
11  
78.77  
24 VDC  
35.3  
90 max.  
(+)  
A1  
Input circuit  
12  
14  
A2  
(–)  
G2RV  
11  
: Diode bridge  
(5.05)  
18.71  
35.18  
51.65  
56.2  
: Light emitting diode  
6.2 max.  
12  
14  
11  
8

G2RV-SR  
Relay for maintenance  
Models without latching lever  
G2RV-1-S-G  
G2RV-1-S-AP-G  
5.2 max.  
30.5 max.  
Terminal Arrangement/  
Internal Connection Diagram  
(TOP VIEW)  
33 max.  
(Input circuit)  
16.2  
12  
A1 A2  
14 11  
1.8  
0.5  
2.4  
3.5  
5.04  
5.04  
22  
3
Models with latching lever (test switch)  
G2RV-1-SI-G  
5.2 max.  
30.5 max.  
Terminal Arrangement/  
Internal Connection Diagram  
(TOP VIEW)  
(Input circuit)  
36 max.  
12  
A1 A2  
14 11  
16.2  
0.5  
1.8  
2.4  
3.5  
5.04  
5.04  
22  
3
9

Slim I/O Solid State Relay  
G3RV-SR  
Global standard size, low profile type  
slim I/O solid state relay with width  
6.2 mm.  
• Realized about 25% lower profile than conventional products,  
contributing to further miniaturization of the control panel.  
• Optimal slim, high frequency, high-speed opening and closing  
SSR (solid state relay).  
• Realized a slim shape with a switching capacity up to  
3 A (DC), and 2 A (AC).  
• Because MOSFET is used for the outlet element for the DC  
load, opening and closing load of 100
μ
A to 3 A is possible.  
• Check operating status at a glance at the operating display  
LED.  
For the recent information on models that have been certified  
for safety standards, refer to your OMRON website.  
• Mounted I/O SSR (solid-state relay) uses plug-in terminals that  
are difficult to bend when exchanging.  
• G2RV-SR featuring a general-purpose relay similar in shape to G3RV-SR also available.  
Refer to
Safety Precautions
on page 20.  
Features  
Push-In Plus technology  
Terminal x 5  
• Push-in  
• Screw  
Short bar insertion holes  
Release hole  
Operation display LED  
(Socket section)  
Release lever  
Operation  
display LED  
(SSR section)  
Terminal (insertion) hole  
Release lever  
Relay easily  
fixed/removed  
90
mm  
Plug-in terminal  
Peace of mind as the terminal  
does not bend when replacing  
80
mm  
10  

G3RV-SR  
Model Number Structure  
Model Number Legend  
G3RV-SR
@ @ @
–
@ @  
(1)  
(2)  
(3)  
(4) (5)  
(1) Basic model name  
G3RV: Slim I/O Solid State Relay  
(4) Output voltage specification  
: AC output (triac) zero cross function available  
AL :
 
AC output (triac) zero cross function not available  
: DC output (MOS FET)  
A
(2) Sub type  
D
SR: Slim solid relay + integrated low profile socket  
(5) Rated voltage input  
12, 24 VDC  
24, 48 VAC/VDC  
(3) Terminal (wire connection)  
500: Push-In Plus Terminal  
700: Screw terminal  
100, 110, 200, 230 VAC  
11  

G3RV-SR  
Ordering Information  
Terminal  
(wire connection)  
Applicable  
output load  
Zero cross  
function  
Rated input voltage  
(V)  
Model  
12  
G3RV-SR500-D DC12  
G3RV-SR500-D DC24  
G3RV-SR500-D AC/DC24  
G3RV-SR500-D AC/DC48  
G3RV-SR500-D AC100  
G3RV-SR500-D AC110  
G3RV-SR500-D AC200  
G3RV-SR500-D AC230  
G3RV-SR500-A DC12  
G3RV-SR500-A DC24  
G3RV-SR500-A AC/DC24  
G3RV-SR500-A AC/DC48  
G3RV-SR500-A AC100  
G3RV-SR500-A AC110  
G3RV-SR500-A AC200  
G3RV-SR500-A AC230  
G3RV-SR500-AL DC12  
G3RV-SR500-AL DC24  
G3RV-SR500-AL AC/DC24  
G3RV-SR500-AL AC/DC48  
G3RV-SR500-AL AC100  
G3RV-SR500-AL AC110  
G3RV-SR500-AL AC200  
G3RV-SR500-AL AC230  
G3RV-SR700-D DC12  
G3RV-SR700-D DC24  
G3RV-SR700-D AC/DC24  
G3RV-SR700-D AC/DC48  
G3RV-SR700-D AC100  
G3RV-SR700-D AC110  
G3RV-SR700-D AC200  
G3RV-SR700-D AC230  
G3RV-SR700-A DC12  
G3RV-SR700-A DC24  
G3RV-SR700-A AC/DC24  
G3RV-SR700-A AC/DC48  
G3RV-SR700-A AC100  
G3RV-SR700-A AC110  
G3RV-SR700-A AC200  
G3RV-SR700-A AC230  
G3RV-SR700-AL DC12  
G3RV-SR700-AL DC24  
G3RV-SR700-AL AC/DC24  
G3RV-SR700-AL AC/DC48  
G3RV-SR700-AL AC100  
G3RV-SR700-AL AC110  
G3RV-SR700-AL AC200  
G3RV-SR700-AL AC230  
DC  
24  
24  
AC/DC  
48  
DC load  
AC load  
DC load  
AC load  
—
Yes  
No  
—
100  
110  
AC  
200  
230  
12  
DC  
24  
24  
AC/DC  
48  
Push-In Plus Terminal  
100  
110  
AC  
200  
230  
12  
DC  
24  
24  
AC/DC  
48  
100  
110  
AC  
200  
230  
12  
DC  
24  
24  
AC/DC  
48  
100  
110  
AC  
200  
230  
12  
DC  
24  
24  
AC/DC  
48  
Screw terminal  
Yes  
100  
110  
AC  
200  
230  
12  
DC  
24  
24  
AC/DC  
48  
No  
100  
110  
AC  
200  
230  
Note:
Sockets are not sold individually.  
12  

G3RV-SR  
Solid state relay for maintenance  
Model Number Legend  
G3RV-
@ @
S
@ @  
(1) (2) (3) (4)
 
(5)  
(1) Output voltage  
specification  
D: DC output  
(3) Terminal  
S: Plug-in type  
(4) Zero cross functions  
2: AC output  
Blank: Zero cross function available  
L: Zero cross function not available  
(2) Rated current  
02: AC output 2 A  
03: DC output 3 A  
(5) Rated input voltage  
Number: 12, 24, 48 VDC  
List of Models  
Rated  
output  
Load *  
Rated input  
voltage  
(socket)  
Insulation
Operation
Output Zero
 
cross  
Model  
Applicable model  
method  
Display  
(SSR)
Function  
12 VDC  
G3RV-202S DC12  
G3RV-202S DC24  
G3RV-SR700/500-A DC12V  
G3RV-SR700/500-A DC24V  
24 VDC  
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
110 VAC  
200 VAC  
230 VAC  
12 VDC  
G3RV-SR700/500-A AC/DC24V  
G3RV-SR700/500-A AC/DC48V  
G3RV-SR700/500-A AC100V  
G3RV-SR700/500-A AC110V  
G3RV-SR700/500-A AC200V  
G3RV-SR700/500-A AC230V  
G3RV-SR700/500-AL DC12V  
G3RV-SR700/500-AL DC24V  
G3RV-SR700/500-AL AC/DC24V  
G3RV-SR700/500-AL AC/DC48V  
G3RV-SR700/500-AL AC100V  
G3RV-SR700/500-AL AC110V  
G3RV-SR700/500-AL AC200V  
G3RV-SR700/500-AL AC230V  
G3RV-SR700/500-D DC12V  
G3RV-SR700/500-D DC24V  
G3RV-SR700/500-D AC/DC24V  
G3RV-SR700/500-D AC/DC48V  
G3RV-SR700/500-D AC100V  
G3RV-SR700/500-D AC110V  
G3RV-SR700/500-D AC200V  
G3RV-SR700/500-D AC230V  
Yes  
G3RV-202S DC48  
2 A  
(at 100 to  
240  
Photo-  
triac  
AC  
G3RV-202SL DC12  
G3RV-202SL DC24  
VAC)  
24 VDC  
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
110 VAC  
200 VAC  
230 VAC  
12 VDC  
Yes  
(green)  
No  
G3RV-202SL DC48  
G3RV-D03SL DC12  
G3RV-D03SL DC24  
24 VDC  
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
110 VAC  
200 VAC  
230 VAC  
Photo-  
voltage  
coupler  
3 A  
(at 5 to  
24 VDC)  
DC  
–
G3RV-D03SL DC48  
*
Different depending on the ambient temperature.  
For more details, refer to
Load current vs. ambient rated temperature
on page 16.  
Accessories (order separately)  
Refer to page 25 for G2RV-SR/G3VR-SR Common Accessories.  
13  

G3RV-SR  
Specifications  
Rating (ambient temperature 25°C)  
Input  
G3RV-SR700/500-A series  
Rated current  
Input voltage  
Rated input  
voltage  
Must operate  
Must release  
voltage  
AC  
Percentage of the  
rated voltage  
voltage  
DC  
50 Hz  
60 Hz  
12 VDC  
–
–
–
15.0 mA  
12.0 mA  
10.8 V max.  
21.6 V max.  
21.6 V max.  
43.2 V max.  
90 V max.  
24 VDC  
–
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
11.3 mA
 
11.4 mA
 
11.0 mA  
6.8 mA  
6.2 mA  
6.2 mA  
6.7 mA  
7.5 mA  
6.9 mA  
6.2 mA  
6.2 mA  
7.9 mA  
8.8 mA  
6.0 mA  
1 V min.  
±10%  
–
–
–
–
110 VAC  
99 V max.  
200 VAC  
180 V max.  
207 V max.  
230 VAC  
G3RV-SR700/500-AL series  
Rated current  
AC  
Input voltage  
Rated input  
voltage  
Must operate  
voltage  
Must release  
voltage  
Percentage of the  
rated voltage  
DC  
50 Hz  
60 Hz  
12 VDC  
–
–
–
15.0 mA  
12.0 mA  
10.8 V max.  
21.6 V max.  
21.6 V max.  
43.2 V max.  
90 V max.  
24 VDC  
–
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
11.4 mA
 
11.5 mA
 
11.0 mA  
7.7 mA  
7.3 mA  
7.3 mA  
7.0 mA  
7.7 mA  
7.7 mA  
7.3 mA  
7.3 mA  
8.1 mA  
8.9 mA  
6.9 mA  
1 V min.  
±10%  
–
–
–
–
110 VAC  
99 V max.  
200 VAC  
180 V max.  
207 V max.  
230 VAC  
G3RV-SR700/500-D series  
Rated current  
AC  
Input voltage  
Rated input  
voltage  
Must operate  
voltage  
Must release  
voltage  
Percentage of the  
rated voltage  
DC  
50 Hz  
60 Hz  
12 VDC  
–
–
–
8.0 mA  
10.8 V max.  
21.6 V max.  
21.6 V max.  
43.2 V max.  
90 V max.  
24 VDC  
–
4.6 mA  
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
5.0 mA  
6.8 mA  
6.2 mA  
6.2 mA  
6.7 mA  
7.5 mA  
5.1 mA  
6.9 mA  
6.2 mA  
6.2 mA  
7.9 mA  
8.8 mA  
4.3 mA  
6.0 mA  
1 V min.  
±10%  
–
–
–
–
110 VAC  
99 V max.  
200 VAC  
180 V max.  
207 V max.  
230 VAC  
Output  
Item  
G3RV-SR700/500-A(L)  
100 to 240 VAC (50/60 Hz)  
G3RV-SR700/500-D  
Rated load voltage  
Load voltage range  
Load current  
5 to 24 VDC  
75 to 264 VAC (50/60 Hz)  
3 to 26.4 VDC  
0.1 to 2 A (Ambient temperature=25°C)
 
100
μ
A to 3 A (Ambient temperature=25°C)  
Inrush current resistance  
30 A (60 Hz, 1 cycle)  
30 A (60 Hz, 1 cycle)  
Permissible l

2

t; Joule integral value  
(reference value)  
15A

2

s  
9 A

2

s  
400 W  
72 W  
Applied load capacity  
(Output voltage: 200 VAC)  
(Output voltage: 24 VDC)  
14  

G3RV-SR  
Characteristics  
Item  
G3RV-SR700/500-A  
G3RV-SR700/500-AL  
3 ms max.  
60 ms max.  
G3RV-SR700/500-D  
6 ms max.  
60 ms max.  
1/2 cycle of load power supply  
+1 ms max.  
Operate time  
Release time  
60 ms max.  
Output ON voltage drop  
Output ON resistance  
Leaked current  
1.6 V (RMS) max.  
–
–
0.3
Ω
max. (at 24 VDC)  
5 mA max. (at 200 VAC, 50/60 Hz)  
10 µA max. (at 24 VDC)  
Insulation resistance  
Dielectric strength  
Vibration resistance  
Shock resistance  
100 M
Ω
min. (at 500 VDC)  
Between input and output 2,500 VAC 50/60 Hz 1 min  
Malfunction: 10 to 55 to 10 Hz double amplitude 0.70 mm  
300m/s

2  

Storage: –30 to +100°C (with no icing or no condensation)  
Operating: –30 to +55°C (with no icing or no condensation)  
Ambient operating temperature  
Ambient operating humidity  
Weight  
45 to 85% RH  
Approx. 38 g  
2
Pollution degree  
The degree of protection by  
IEC60529  
IP20  
Rated impulse dielectric  
strength  
4.0 kV/
III  
Load category  
LC-A  
DC-12  
1.5Ie 1.1Ue  
5s ON, 10s OFF, 10 cycles  
Overload current profile  
Rated insulation voltage  
240 V  
Approved standards  
UL 508 (file No.E64562)  
Model  
Input ratings  
12, 24 VDC  
24, 48 VAC/VDC  
100, 110, 200, 230 VAC  
Contact ratings  
24 VDC 3 A (resistive load) at 25°C  
G3RV-SR700/500-D series  
G3RV-SR700/500-A(L) series  
12, 24 VDC  
24, 48 VAC/DC  
240 VAC 2 A (resistive load) at 25°C  
100, 110, 200, 230 VAC  
TÜV(EN 62314)  
Model  
Input ratings  
Contact ratings  
12, 24 VDC  
G3RV-SR700/500-D series  
G3RV-SR700/500-A(L) series  
24, 48 VAC/VDC  
100, 110, 200, 230 VAC  
24 VDC 3 A (resistive load)  
12, 24 VDC  
24, 48 VAC/VDC  
100, 110, 200, 230 VAC  
240 VAC 2 A (resistive load)  
15  

G3RV-SR  
Engineering Data  
Load current vs. ambient rated temperature  
G3RV-SR700/500-A(L) series  
Product mounting spacing 10 mm (Separate Mounting)  
Close mounting (up to 5 units *)  
5
5
4
3
2
4
3
2
1
1
0
0.2  
0
−30 −20  
−30 −20  
0
20 25
 
40 55
 
60  
80  
100  
0
20 25
 
40 55
 
60  
80  
100  
Ambient temperature (°C)  
Ambient temperature (°C)  
G3RV-SR700/500-D series  
Product mounting spacing 10 mm (Separate Mounting)  
Close mounting (up to 5 units *)  
5
5
4
3
2
4
3
2
1
1
0
0.5  
0
−30 −20  
0
20 25
 
40 55
 
60  
80  
100  
−30 −20  
0
20 25
 
40 55
 
60  
80  
100  
Ambient temperature (°C)  
Ambient temperature (°C)  
*
When five or more are installed, install with 10 mm space between  
each.  
For details, please refer to
Mounting
on page 23.  
Inrush Current Resistance: Non-repetitive  
Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively.  
G3RV-SR700/500-A(L) series  
G3RV-SR700/500-D series  
40  
40  
35  
30  
35  
30  
25  
20  
15  
10  
5
25  
20  
15  
10  
5
0
0
10  
30 50
 
100  
300 500
 
1,000 3,000
 
5,000  
Energized time (ms)  
10  
30 50
 
100  
300 500
 
1,000 3,000
 
5,000  
Energized time (ms)  
16  

G3RV-SR  
Dimensions  
(unit: mm)  
Solid state relay + socket  
Push-In Plus Terminal Block  
G3RV-SR500  
Terminal Arrangement/  
Internal Connection Diagram  
(TOP VIEW)  
12 VDC  
Input circuit  
(+)  
A1  
78 max.  
G3RV  
A2  
(–)  
A2–  
INPUT  
3.4  
74.5  
74.1  
A1+  
13 (+)  
35.25  
18.78  
OUTPUT  
14 (–)  
(5.05)  
12  
14  
The information in  
parentheses in for  
a DC
out
put.  
13  
78.77  
35.3  
90 max.  
24 VDC  
(+)
Input circuit  
A1  
G3RV  
A2  
(–)  
A2–  
INPUT  
A1+  
(5.05)  
18.78  
35.25  
51.72  
59.71  
6.2 max.  
13 (+)  
OUTPUT  
14 (–)  
12  
14  
The information in  
parentheses in for  
a DC
out
put.  
13  
Other voltage  
Input circuit  
A1  
A2  
G3RV  
A2–  
INPUT  
A1+  
13 (+)  
OUTPUT  
14 (–)  
12  
14  
The information in  
parentheses in for  
a DC
out
put.  
13  
: Diode bridge  
: Light emitting diode  
17  

G3RV-SR  
Screw terminal  
G3RV-SR700  
Terminal Arrangement/  
Internal Connection Diagram  
(TOP VIEW)  
12 VDC  
78 max.  
Input circuit  
(+)  
A1  
3.4  
74.5  
74.1  
G3RV  
A2  
(–)  
35.18  
18.71  
A2–  
INPUT  
(5.05)  
A1+  
13 (+)  
OUTPUT  
14 (–)  
12  
14  
The information in  
parentheses in for  
a DC
out
put.  
78.77  
35.3  
90 max.  
13  
24 VDC  
(+)  
A1  
Input circuit  
(5.05)  
18.71  
35.18  
51.65  
56.2  
G3RV  
A2  
(–)  
6.2 max.  
A2–  
INPUT  
A1+  
13 (+)  
OUTPUT  
14 (–)  
12  
14  
The information in  
parentheses in for  
a DC
out
put.  
13  
Other voltage  
Input circuit  
A1  
A2  
G3RV  
A2–  
INPUT  
A1+  
13 (+)  
OUTPUT  
14 (–)  
12  
14  
The information in  
parentheses in for  
a DC
out
put.  
13  
: Diode bridge  
: Light emitting diode  
18  

G3RV-SR  
Solid state relay for maintenance  
Terminal Arrangement/  
Internal Connection Diagram  
(TOP VIEW)  
G3RV-D03SL  
G3RV-202S(L)  
G3RV-D03SL (input circuit)  
Input  
30.5 max.  
Load  
33 max.  
15.8  
14 13  
G3RV-202S(L) (input circuit)  
Input  
A1 A2  
1.8  
3.5  
2.4  
22  
3
5.04  
5.2 max.  
Load  
14 13  
A1 A2  
19  

G2RV-SR/G3RV-SR  
Safety Precautions  
Be sure to read the
Safety Precautions for All Relays
in the website at the following URL:  
Format of Warning Indications  
WARNING  
Indicates a potentially hazardous situation  
which, if not avoided, will result in minor or  
Ensure that the socket is not charged during wiring and  
maintenance. Not doing so may result in electric shock.  
moderate injury, or may result in serious  
injury or death. Additionally, there may be  
significant property damage.  
WARNING  
Do not touch the terminal section of the G2RV-SR or the  
surrounding area while the power is being supplied.  
Doing so may result in electric shock.  
Indicates a potentially hazardous situation  
which, if not avoided, may result in minor or  
moderate injury or in property damage.  
CAUTION  
Indicates supplementary comments on  
what to do or avoid doing, to use the  
product safety.  
Precautions  
for Safe Use  
CAUTION  
Minor electrical shock may occasionally occur.  
Do not touch the G3RV terminal section (i.e., current  
carrying parts) while the power is being supplied.  
Includes operating precautions to ensure  
that the product will operate properly and  
that performance and functions will not be  
adversely affected.  
Precautions  
for Correct  
Use  
The G3RV may rupture if short-circuit current flows.  
As protection against accidents due to short-circuiting,  
be sure to install protective devices, such as fuses and  
no-fuse breakers, on the power supply side.  
Meaning of Graphic Symbols for Ensuring Product Safety  
Indicates the possibility of electric shock under  
specific conditions.  
Minor electrical shock may occasionally occur.  
Do not touch the main circuit terminals on the G3RV  
immediately after the power supply has been turned  
OFF.  
Shock may result due to the electrical charge stored  
in the built-in snubber circuit.  
Used for general CAUTION, WARNING, or  
DANGER precautions for which there is no  
specified symbol. (This symbol is also used as  
the alerting symbol, but shall not be used in this  
meaning on the product.)  
Indicates the possibility of explosion or rupture  
under specific conditions.  
Note: G3RV-202S(L), G3RV-SR500/700-A(L) series  
models only  
Minor burns may occasionally occur.  
Indicates the possibility of injuries by high  
temperature under specific conditions.  
Do not touch the G3RV or the heat sink while the  
power is being supplied or immediately after the  
power supply has been turned OFF.  
The G3RV becomes extremely hot.  
Provide a space of at least 3 mm between the G2RV-  
SR and ground. Not doing so may result in a ground  
fault.  
20  

G2RV-SR/G3RV-SR  
Precautions for Safe Use  
Transport  
• Do
 
not use the product if it has been dropped on the ground.  
Dropping the product may adversely affect performance.  
• Do
 
not drop the product or subject it to abnormal vibration or shock  
during transportation or mounting. Doing so may result in  
deterioration of performance, malfunction, or failure.  
• Do
 
not transport the product without it being packaged. Doing so  
may result in damage, malfunction, or failure.  
Usage  
• Please
 
select the load within the rated range. Doing so may result  
in damage, malfunction, or failure.  
• Do
 
not transport the G3RV under the following conditions. Doing  
so may result in damage, malfunction, or deterioration of  
performance characteristics.  
• Please
 
use the power of the rated frequency. It may cause  
malfunction, failure, or risk of burnout.  
<G3RV>  
• High
 
temperature, high humidity conditions  
• Install
 
G3RV according to instructions
Mounting
on page 23. If you  
• Conditions
 
such as temperature change that causes rapid  
condensation  
install in the wrong direction, abnormal heat is generated, and may  
lead to short-circuiting or burning the output element.  
• G3RV
 
is an SSR that generates heat. Please observe the ambient  
temperature setting range of G3RV. If installing in an enclosed  
space, set a fan, and ventilate.  
• Condition
 
where it is not packaged  
Operating and Storage Environments  
• Do
 
not use or store the product in the following locations. Doing so  
may result in damage, malfunction, or deterioration of performance  
characteristics.  
• When
 
mounting G3RV to DIN rail, firmly fits into the groove. If it is  
not properly installed, there is a risk of it falling.  
• Do
 
not store in locations subject to ambient storage  
temperatures outside the range –40 to 70°C (for G2RV) and  
outside the range –30 to 100°C (for G3RV).  
Wiring  
•
For the current to be applied, make sure a wire size with margin is used.  
Otherwise, excessive heat generated by the wires may cause burning  
.
• Locations
 
subject to relative humidity outside the range 5% to  
85% (for G2RV) and outside the range 45% to 85% (for G3RV).  
• Locations
 
subject to high temperature or high humidity.  
• Conditions
 
such as temperature change that causes rapid  
condensation  
• Do
 
not attempt to use the wire if the coat is torn. Not doing so may  
result in electric shock.  
• Always
 
turn OFF the power supply before performing wiring. Not  
doing so may cause electrical shock.  
<G3RV>  
• L
ocations where corrosive gases or flammable gases are present  
• Location
 
where rainwater or water droplets gets splashed  
• Location
 
with splashes of water, oil, and chemicals, etc.  
• Locations
 
with much dust, salt, and iron powder  
• Location
 
with blockers  
• The
 
wires of the socket for G3RV socket should not be passed  
through the same duct as that being connected to the high-voltage  
power supply. Otherwise, inductive noise may damage the G3RV  
or cause it to malfunction.  
• Where
 
static electricity or noise occurs  
Push-In Plus Terminal Block  
• Do
 
not wire anything to the release holes.  
• Where
 
strong electromagnetic field is generated  
• Where
 
there is a risk of exposure to radioactivity  
• Do
 
not use or store Sockets in environments that contain silicone  
gas, sulfidizing gas (e.g., SO

2

or H
2
S), or organic gas, or near  
materials that contain silicone. Doing so may cause the contacts to  
be unstable or to fail.  
•
Do not tilt or twist a flat-blade screwdriver while it is inserted into a release  
hole on the terminal block. The terminal block may be damaged  
.
• Insert
 
a flat-blade screwdriver into the release holes at an angle.  
The terminal block may be damaged if you insert the screwdriver  
straight in.  
• Do
 
not allow the flat-blade screwdriver to fall out while it is inserted  
into a release hole.  
Handling <G3RV>  
• Keep
 
the G3RV well ventilated.  
There is a risk of short-circuiting or burning due to G3RV  
overheating.  
•
Do not bend the wire past its natural bending radius or pull on it  
with excessive force. Doing so may cause the wire disconnection.  
•
Do not insert more than one wire into each terminal (insertion) hole  
.
Mounting  
• To
 
prevent wiring materials from smoking or ignition, confirm wire  
ratings and use the wiring materials given in the following table.  
• Before
 
you start wiring, please make sure that the socket is  
securely attached to the mounting rail. If the socket is unstable, it  
may come loose and risk of injury towards the workers.  
Stripping length  
Recommended Wire  
(Ferrules not used)  
•
Please insert the flat-blade screwdriver to the bottom of the hole. If  
you do not insert the flat-blade screwdriver correctly, the cable will  
0.5 to 1.5 mm

2

/AWG20 to AWG16  
8 mm  
Disposal  
not be connected correctly  
.
• When
 
disposing of the product, do not put into the fire.  
• When
 
lubricant such as oil is attached to the tip of the driver, the  
driver will fall off, with a risk of injury towards the workers.  
• Do
 
not tilt the G2RV-SR/G3RV-SR after mounting to the support  
rail. Doing so may apply excessive force to the mounting portion,  
possibly damaging the product. Attach end plates (PFP-M) to  
sandwich the product and hold it in place.  
21  

G2RV-SR/G3RV-SR  
Precautions for Correct Use  
• Do
 
not use or store the product in the following locations. Doing so  
may result in damage, malfunction, or deterioration of performance  
characteristics.  
• When
 
replacing relays, there is a possibility the relay will pop out  
and fall. Take care to prevent the relay from falling during  
replacement.  
• Where
 
vibration or shock is directly transmitted to the body  
• Where
 
the socket could come into contact with a solvent or  
alkaline agent  
Push-In Plus Terminal Block  
1. Connecting Wires to the Push-In Plus Terminal Block  
Part Names of the Terminal Block  
• Insert
 
the short bar into the insertion hole in the correct orientation,  
and insert until all terminals are all the way in.  
• If
 
using a short bar, install the short bar before performing wiring  
work.  
Release hole  
T
e
rminal (Insertion) hole  
• A
 
push-in Plus terminal block type and a screw terminal type have  
different insertion positions, so a mixed installation using the same  
short bar is not possible.  
Connecting Wires with Ferrules and Solid Wires  
Insert the solid wire or ferrule straight into the terminal block until the  
end strikes the terminal block.  
Orient correctly  
and push all the  
way in.  
Release hole  
T
e
rminal  
(Insertion) hole  
Ferrules or  
solid wire  
Completely inserted  
• If
 
a wire is difficult to connect because it is too thin, use a flat-blade  
screwdriver in the same way as when connecting stranded wire.  
All terminals are inserted all the way in.  
Connecting Stranded Wires  
Use the following procedure to connect the wires to the terminal block.  
(1) Hold a flat-blade screwdriver at an angle and insert it into the  
release hole.  
The angle should be between 10°and15°. If the flat-blade  
screwdriver is inserted correctly, you will feel the spring in the  
release hole.  
(2) With the flat-blade screwdriver still inserted into the release hole,  
insert the wire into the terminal hole until it strikes the terminal  
block.  
(3) Remove the flat-blade screwdriver from the release hole.  
Flat-blade screwdriver  
(3)  
(1)  
Incomplete insertion  
All terminals are not inserted  
all the way in.  
Incorrect installation  
Some terminals not inserted  
completel
y
.  
10 to 15°  
(3)  
(1)  
(2)  
Stranded Wires  
Incomplete  
insertion  
Checking Connections  
• After
 
the insertion, pull gently on the wire to make sure that it will  
not come off and the wire is securely fastened to the terminal block.  
• If
 
you use a ferrule with a conductor length of 10 mm, part of the  
conductor may be visible after the ferrule is inserted into the  
terminal block, but the product insulation distance will still be  
satisfied.  
• Do
 
not insert short bar in the hole for wire or screw driver, it may  
cause the result of failure of pull out.  
2. Removing Wires from the Push-In Plus Terminal Block  
Use the following procedure to remove wires from the terminal block.  
The same method is used to remove stranded wires, solid wires, and  
ferrules.  
(1) Hold a flat-blade screwdriver at an angle and insert it into the  
release hole.  
If insert short bar in the hole for wire or screw driver and try to pull  
out, it may cause damage for short bar or socket and failure in  
electric conductivity.  
• Please
 
insert P2RVC terminal into the short bar insertion hole of  
G2RV-SR/G3RV-SR. If insert P2RVC into the release hole or  
terminal (insertion) hole wrongly, P2RVC may stuck and can not  
remove and it may cause result of damage on P2RVC and G2RV-  
SR/G3RV-SR.  
(2) With the flat-blade screwdriver still inserted into the release hole,  
remove the wire from the terminal insertion hole.  
(3) Remove the flat-blade screwdriver from the release hole.  
Flat-blade screwdriver  
(3)  
(1)  
10 to 15°  
Wire  
(3)  
Please turn off the power of input and output side and remove PLC  
interface unit when replacing mounting relays and SSRs for  
maintenance.  
(1)  
(2)  
22  

G2RV-SR/G3RV-SR  
3. Recommended ferrules and Crimp Tools  
Recommended ferrules  
Recommended Flat-blade Screwdriver  
Use a flat-blade screwdriver to connect and remove wires.  
Use the following flat-blade screwdriver.  
The following table shows manufacturers and models as of 2015/Dec.  
Applicable  
wire  
Stripping  
length  
(mm)  
(Ferrules  
used)  
Ferrules  
Conduct  
length  
Recommended ferrules  
Side  
Front  
Phoeni
x
C
ontact
Weidmuller  
Wago  
product  
(mm

2

)
(AWG)  
(mm)  
product  
product  
2.5 mm dia.  
8
10  
8
10  
12  
10  
12  
10  
12  
10  
12  
10  
12  
10  
12  
AI 0,25-8  
AI 0,25-10  
AI 0,34-8  
AI 0,34-10  
AI 0,5-8  
H0.25/12 216-301  
— —  
H0.34/12 216-302  
0.25  
0.34  
0.5  
24  
22  
20  
18  
0.4 mm  
2.5 mm  
10  
8
—  
—  
H0.5/14  
H0.5/16  
216-201  
216-241  
Model  
Manufacturer  
10  
8
AI 0,5-10  
AI 0,75-8  
AI 0,75-10  
AI 1-8  
ESD 0,40×2,5  
SZS 0,4×2,5  
SZF 0-0,4×2,5
*
 
0.4×2.5×75 302  
AEF.2,5×75  
Wera  
H0.75/14 216-202  
H0.75/16 216-242  
Phoenix Contact  
0.75  
10  
8
Wiha  
H1.0/14  
H1.0/16  
H1.5/14  
H1.5/16  
216-203  
216-243  
216-204  
216-244  
Facom  
Wago  
1/1.25 18/17  
1.25/1.5
17/16  
10  
8
AI 1-10  
210-719  
AI 1,5-8  
SDI 0.4×2.5×75  
Weidmuller  
10  
AI 1,5-10  
*
OMRON’s exclusive purchase model XW4Z-00B is available to  
order as SZF 0-0
,
4×2
,
5 (manufactured by Phoenix Contact).  
CRIMPFOX6  
Recommended crimp tool  
CRIMPFOX6T-F
PZ6 roto  
CRIMPFOX10S  
Variocrimp4  
Screw Terminal  
• Screw terminal  
Note: 1.
 
Make sure that the outer diameter of the wire is smaller than  
the inner diameter of the insulating sleeve of the  
recommended ferrule.  
Applicable wire  
size  
Stripping  
length  
Wired type  
2.
Make sure that the ferrule processing dimensions conform  
to the following figure.  
Stranded wires, without  
ferrule  
0.5 to 1.5 mm

2  

0.5 to 1.5 mm

2  

8 mm  
Stranded wires, with ferrule  
and plastic collar  
8 mm  
8 to 10 mm  
Stranded wires with ferrule,  
without plastic collar  
0.5 to 1.5 mm

2  

0.5 to 1.5 mm

2  

8 mm  
8 mm  
2.6 mm max.  
1.9 mm max.  
Single wire  
3.
If you use AWG24 to AWG22 (0.25 to 0.34 mm

2

) wires, UL  
certification will not apply.  
• Tightening Torque  
0.4 N • m  
• Electric wiring  
Use the electric wire of specified size as shown above. The length  
of the that is not covered is 8 mm.  
Screw terminal  
8 mm  
Stripping length  
<G2RV>  
Operating latching lever (test switch)  
When operating the latching lever for G2RV-SR701/501  
series, use a 2.5 mm width flat-blade screwdriver.  
• Applicable
 
flat-blade screwdriver  
Flat-blade screwdriver with parallel cutting edge: shaft diameter  
2.5 mm (3.0 mm max.)  
Parallel cutting edge flat-blade screwdriver  
Shaft diameter 2.5 mm (3.0 mm max.)  
Wide flat-blade screwdriver  
Driver with a thick shaft cannot be used.  
• Always
 
turn OFF the power supply before operating latching lever.  
• Return
 
to its original state after using the latching lever.  
23  

G2RV-SR/G3RV-SR  
• Do
 
not use the latching lever as a switch.  
<Relationship of SSR and duct (duct depth)>  
• Operation
 
durability of the latching lever is 100 times or more.  
• Do
 
not keep the latching lever ON for a long period of time (24  
hours or more) in order to maintain the operation check function.  
Incorrect Example  
Countermeasure 1  
Recommended height of the duct is  
1/2 or less of the height of the SSR  
Countermeasure 2  
Duct or other object  
blocking airflow  
Duct or other object  
blocking airflow  
Duct or  
Method of operation of the latching lever (test  
switch)  
other object  
blocking  
airflow  
Airflow  
Height of SSR  
<Protective cover: locked>
 
<Protective cover: disengage>  
Contact normal position  
Vertical  
Direction  
Metal  
base  
SSR  
SSR  
Contact operating position (on-state)  
SSR  
Close protective cover  
Open protective cover  
Duct or other object  
blocking airflow  
Duct or other object  
blocking airflow  
Duct or other object  
blocking airflow  
Do not enclose the SSR in a  
duct of the same height.  
It will interfere with the heat  
dissipation of SSR.  
Use ducts that have a  
shallow depth, to provide a
 
place the SSR on a metal base so  
sufficient ventilation area.
 
that it is not surrounded by the ducts.  
If the ducts cannot be made lower,  
<Ventilation Outside the Control Panel>  
Be aware of airflow  
Duct or other object  
blocking airflow  
Exhaust  
(Axial fan)  
Keep the protective cover open when using the latching lever. Move  
until the latching lever clicks to the ON position (ON state). After use  
latching lever, in order to prevent malfunction, return the switch to  
contact normal position (OFF state), and make sure the protective  
cover is firmly closed.  
SSR  
SSR  
SSR  
Using the latching lever  
Example: check the operation of the relay and the sequence circuit  
Inlet  
<G3RV>  
• If
 
the air inlet or air outlet has a filter, clean the filter regularly to  
prevent it from clogging to ensure an efficient flow of air.  
• Do
 
not place objects that may obstruct the proper ventilation for  
outside or inside the inlet or exhaust port, and in the outside  
vicinity.  
• Since
 
the G3RV uses electronic components, do not allow it to fall,  
vibrate, or apply shock that exceeds the criteria. Doing so may  
result in failure, malfunction, or deterioration of performance.  
• Tighten
 
screw terminal for G3RV at torque 0.4 N · m. It may cause  
short-circuit failure or burning.  
• A
 
heat exchanger, if used, should be located in front of the G3RV  
to ensure the efficiency of the heat exchanger.  
• Please
 
use the voltage and current suitable for the input and  
output terminal portion of G3RV. It may cause short-circuit failure  
or burning.  
• Please
 
observe the ambient temperature of G3RV. The rated  
current of the G3RV is measured at an ambient temperature of  
25°C.  
Mounting  
• The
 
G3RV uses a semiconductor in the output element.  
This causes the temperature inside the control panel to increase  
due to heating resulting from the flow of electrical current through  
the load. The G3RV reliability can be increased by adding a  
ventilation fan to the control panel to dispel this heat, thus lowering  
the ambient temperature of the G3RV.  
<The SSR Mounting Pitch (Panel Mounting)>  
Duct or other object blocking airflow  
60 mm min.  
10 mm min.  
SSR  
(It suggests that life expectancy is doubled by each 10°C reduction  
in ambient temperature.)  
Vertical Direction  
EMI  
The G3RV is a Class A product (for industrial environments). When  
used in a residential environment, it may cause radio interference.  
In such case, the user may be required to take appropriate  
measures.  
30 mm min.  
80 mm min.  
*
When five or more are installed, install with 10 mm space between  
each.  
24  

G2RV-SR/G3RV-SR  
For G2RV-SR/G3VR-SR  
Common Accessories (order separately)  
Ordering Information  
Short Bars  
No. of  
poles  
Minimum order  
(Quantity)  
Maximum energizing  
current  
Appearance  
Pitch  
Colors  
Model *  
2
PYDN-6.2-020
@
 
PYDN-6.2-030
@  
PYDN-6.2-040
@  
PYDN-6.2-100
@  
PYDN-6.2-200
@  
3
Red (R),  
Blue (S),  
Yellow (Y)  
6.2 mm  
4
10  
32 A  
10  
20  
Note:
Use for wiring to the adjacent socket.  
*
Replace the box (
@
) in the model number with the code for the covering color.
@
color selection: R = red, S = blue, Y = yellow  
Label  
Minimum order (Sheet)  
(Pieces per sheet)  
Appearance  
Model  
XW5Z-P2.5LB1
*
 
5
(1 sheet/72 pieces)  
XW5Z-P2.5LB2  
*
Available following June 2017 production.  
Separate Plate  
Appearance  
Model  
XW5Z-EP12  
PLC interface unit  
Appearance  
I/O classification  
Connection method  
Common process  
Applicable Models
*  
G2RV-SR500-AP  
Model  
P2RVC-8-I-5-1  
P2RVC-8-I-5  
PNP  
NPN  
PNP  
PNP  
NPN  
Push-In  
Screw  
For input  
G2RV-SR700-AP  
P2RVC-8-I-7-1  
P2RVC-8-O-5-1  
P2RVC-8-O-5  
G2RV-SR500  
G2RV-SR501  
G3RV-SR500  
Push-In  
For output  
G2RV-SR700  
G2RV-SR701  
G3RV-SR700  
Screw  
PNP  
P2RVC-8-O-7-1  
*
Please make sure applicable models, P2RVC can not be used other combination than the above table.  
Parts for DIN Track Mounting  
Minimum order  
(Quantity)  
Appearance  
Type  
Model  
1 m  
PFP-100N  
PFP-50N  
DIN Tracks  
1
0.5 m  
End Plate
*  
PFP-M  
PFP-S  
10  
Spacer  
*
When mounting DIN Track, please use End Plate (PFP-M).  
Refer to your OMRON website for details on PFP-
@
.  
25  

G2RV-SR/G3RV-SR  
Applicable Cables  
Cable  
length L  
(mm)  
Name  
Appearance  
Connecting Cables  
Applicable Connectors  
1,000  
2,000  
3,000  
5,000  
P2RV-A100C  
P2RV-A200C  
P2RV-A300C  
P2RV-A500C  
End A  
Device  
end  
End B  
PLC interface  
unit end  
Cables with Loose  
8 I/O  
Wires  
Various devices  
points  
P2RV-A
@
C  
L
70  
P2RV-4-100C  
1,000  
2,000  
3,000  
5,000  
1,000  
2,000  
3,000  
5,000  
1,000  
2,000  
3,000  
5,000  
P2RV-4-200C  
Cables with  
32 output  
PLC I/O Units with MIL connectors (1:4)  
CJ1W-OD232/OD262, etc.  
Connectors (1:4)  
points  
P2RV-4-
@
C  
P2RV-4-300C  
P2RV-4-500C  
L
L
L
300  
300  
300  
P2RV-4-100IMC  
P2RV-4-200IMC  
P2RV-4-300IMC  
P2RV-4-500IMC  
P2RV-4-100IFC  
P2RV-4-200IFC  
P2RV-4-300IFC  
P2RV-4-500IFC  
Cables with  
32 input  
PLC I/O Units with MIL connectors (1:4)  
CJ1W-ID232/ID262, etc.  
Connectors (1:4)  
points  
P2RV-4-
@
IMC  
Cables with  
32 input  
PLC I/O Units with Fujitsu connectors (1:4)  
CJ1W-ID231/ID261, etc.  
Connectors (1:4)  
points  
P2RV-4-
@
IFC  
P2RV-A050C-OMR GRT1  
P2RV-A100C-OMR GRT1  
P2RV-A050IC-OMR GRT1  
P2RV-A100IC-OMR GRT1  
P2RV-A050C-OMR NX  
P2RV-A100C-OMR NX  
P2RV-A050IC-OMR NX  
P2RV-A100IC-OMR NX  
500  
1,000  
500  
8 output  
Cables with Connectors
 
points  
(1:1)  
Slice I/O Units (1:1)  
For inputs: GRT1-ID8-1  
For outputs: GRT1-OD8-1  
P2RV-A  
@
C-OMR GRT1
 
8 input  
L
points  
1,000  
500  
Removable  
terminal block  
8 output  
PLC I/O Units with screw-less clamp  
terminal block (1:1)  
For inputs: NX-ID4442  
points  
Cables with  
1,000  
500  
Connectors (1:1)  
P2RV-A
@
C-OMR NX
 
8 input  
For outputs: NX-OD4256  
points  
L
1,000  
26  

G2RV-SR/G3RV-SR  
Cable  
length L  
(mm)  
Name  
Appearance  
Connecting Cables  
Applicable Connectors  
P2RV-050C-SCH-A  
P2RV-100C-SCH-A  
P2RV-200C-SCH-A  
P2RV-300C-SCH-A  
P2RV-500C-SCH-A  
P2RV-050C-SCH-B  
P2RV-100C-SCH-B  
P2RV-200C-SCH-B  
P2RV-300C-SCH-B  
P2RV-500C-SCH-B  
P2RV-050C-SCH-C  
P2RV-100C-SCH-C  
P2RV-200C-SCH-C  
P2RV-300C-SCH-C  
P2RV-500C-SCH-C  
P2RV-050C-SCH-D  
P2RV-100C-SCH-D  
P2RV-200C-SCH-D  
P2RV-300C-SCH-D  
P2RV-500C-SCH-D  
P2RV-050C-SIM-A  
P2RV-100C-SIM-A  
P2RV-200C-SIM-A  
P2RV-300C-SIM-A  
P2RV-500C-SIM-A  
P2RV-050C-SIM-B  
P2RV-100C-SIM-B  
P2RV-200C-SIM-B  
P2RV-300C-SIM-B  
P2RV-500C-SIM-B  
500  
End A  
De
v
ice  
end  
End B  
PLC interface  
1,000  
2,000  
3,000  
5,000  
500  
32 input  
points  
u
nit end  
Schneider Electric PLCs with 32-point  
connectors (1:4)  
For inputs: 140 DDI 353 00  
For outputs: 140 DDO 353 00  
1,000  
2,000  
3,000  
5,000  
500  
32 output  
points  
Schneider Electric  
PLC Connecting  
Cables  
L
300  
P2RV-
@
C-SCH-
@  
1,000  
2,000  
3,000  
5,000  
500  
16 input  
points  
Schneider Electric PLCs with  
16-point connectors (1:2)  
For inputs: BMX DDI 1602  
For outputs: BMX DDO 1602  
1,000  
2,000  
3,000  
5,000  
500  
16 output  
points  
L
300  
1,000  
2,000  
3,000  
5,000  
500  
32 input  
points  
Siemens PLCs with  
32-point connectors (1:4)  
For inputs: 6ES7 321-1BL00-0AA0  
For outputs: 6ES7 322-1BL00-0AA0  
1,000  
2,000  
3,000  
5,000  
32 output  
points  
L
L
L
300  
300  
300  
P2RV-050C-SIM-C  
P2RV-100C-SIM-C  
P2RV-200C-SIM-C  
P2RV-300C-SIM-C  
P2RV-500C-SIM-C  
500  
1,000  
2,000  
3,000  
5,000  
Siemens PLC  
Connecting Cables  
P2RV-
@
C-SIM-
@  
Siemens PLCs with  
16-point connectors (1:2)  
For inputs: 6ES7 321-1BH02-0AA0  
16 input  
points  
P2RV-050C-SIM-D  
P2RV-100C-SIM-D  
P2RV-200C-SIM-D  
P2RV-300C-SIM-D  
P2RV-500C-SIM-D  
P2RV-050C-SIM-E  
P2RV-100C-SIM-E  
P2RV-200C-SIM-E  
P2RV-300C-SIM-E  
P2RV-500C-SIM-E  
500  
1,000  
2,000  
3,000  
5,000  
500  
32 input  
points  
Siemens PLCs with  
32-point connectors (1:4)  
For inputs: 6ES7 421-1BL-0AA0  
For outputs: 6ES7 422-1BL-0AA0  
1,000  
2,000  
3,000  
5,000  
32 output  
points  
27  

G2RV-SR/G3RV-SR  
PLC interface unit  
Ratings / characteristices  
Rated voltage  
30 VAC/DC  
Rated current  
0.5 A/poles, 2 A/unit  
Ambient operating temperature  
−
40 to 55°C  
Destruction  
10 to 55 to 10 Hz, single amplitude 0.75 mm (double amplitude 1.5 mm)  
Vibration resistance  
Shock resistance  
Malfunction  
Destruction  
Malfunction  
10 to 55 to 10 Hz, single amplitude 0.75 mm (double amplitude 1.5 mm)  
300 m/s

2  

100 m/s

2  

Electrical schematic  
Input  
P2RVC-8-I-
@
-1 (PNP)  
P2RVC-8-I-5 (NPN)  
1………………..8  
1………………..8  
14  
14  
11  
11  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
Output  
P2RVC-8-O-
@
-1 (PNP)  
P2RVC-8-O-5 (NPN)  
1………………..8  
1………………..8  
A2  
A2  
A1  
A1  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
28  

G2RV-SR/G3RV-SR  
Dimensions  
(unit: mm)  
PLC interface unit  
Push-I
N  
P2RVC-8-I-5(-1)  
P2RVC-8-O-5(-1)  
49.60  
67.16  
12.68  
7×6.20  
29  
Screw  
P2RVC-8-I-7-1  
P2RVC-8-O-7-1  
49.60  
67.16  
12.68  
7×6.20  
29  
29  

G2RV-SR/G3RV-SR  
(Except for PLC interface unit)  
Common Accessories (order separately)  
Dimensions  
(unit: mm)  
Short Bars  
PYDN-6.2-
@@
(6.2 mm)  
Maximum carry  
Pitch  
No. of poles  
L (Length)  
Colors  
Model
*  
current  
2
3
12.4  
18.6  
24.8  
62  
PYDN-6.2-020
@  
PYDN-6.2-030
@  
PYDN-6.2-040
@  
PYDN-6.2-100
@  
PYDN-6.2-200
@  
2
1.20  
9
L
Red (R)  
Blue (S)  
Yellow (Y)  
6.2 mm  
4
32 A  
14  
10  
20  
124  
6.20  
Note:
Use the Short Bars for crossover wiring within one Socket or between Sockets.  
*
Replace the box (
@
) in the model number with the code for the covering color.  
Separate Plate  
XW5Z-EP12  
12  
56  
63  
Parts for DIN Track Mounting  
Refer to your OMRON website for details on the PFP-
@
.  
Safety Precautions  
Precautions for Correct Use  
When mounting a short bar  
• Intermediate
 
pins can be bent by a tool or by hand and cut off for use.  
Mounting a separate plate  
• Use
 
a flat-blade screwdriver to tighten the center top screw and  
secure the plate. Loosen the screw to remove the plate from the  
DIN rail.  
M4 Screw  
Bend  
Cut off  
• The
 
short bar can be cut to as many poles as needed. Insert the  
tool from the plastic part side, and cut along the groove in the  
plastic part between the terminals. When cutting, take care not to  
break or deform the terminals.  
However, because the metal on the cut surface will be exposed,  
insulation countermeasures between adjacent products must be  
ensured. Such countermeasures include widening the intervals  
between products or using XW5Z-EP12 separate plates (order  
separately).  
Cut  
30  

Terms and Conditions Agreement  
Read and understand this catalog.  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have  
any questions or comments.  
Warranties.  
(a) Exclusive Warrant
y
.
O
mron’s exclusive warranty is that the Products will be free from defects in materials and workmanship  
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing  
by Omron). Omron disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESEN
T
A
T
ION, EXPRESS OR IMPLIED, ABOUT  
NON-INFRINGEMEN
T
,
M
ERCHAN
T
A
BILITY OR FITNESS FOR A
P
A
RTICULAR PURPOSE OF THE  
PRODUCTS. BUYER ACKNOWLEDGES TH
A
T
I
T ALONE HAS DETERMINED TH
A
T
T
HE PRODUCTS WILL  
SUI
T
A
B
L
Y
M
EET THE REQUIREMENTS OF THEIR INTENDED USE.  
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products  
or otherwise of any intellectual property right. (c) Buyer Remed
y
.
O
mron’s sole obligation hereunder shall be, at Omron’s election,  
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the  
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price  
of the non-complying Product; provided that in no event shall Omron be responsible for warrant
y
,
r
epair, indemnity or any other  
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,  
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by  
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or  
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system  
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in  
writing, are not to be construed as an amendment or addition to the above warrant
y
.  
Limitation on Liability; Etc.  
OMRON COM
P
A
NIES SHALL NOT BE LIABLE FOR SPECIAL, INDIREC
T
,
I
NCIDEN
T
A
L, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY W
A
Y
C
ONNECTED WITH THE PRODUCTS,  
WHETHER SUCH CLAIM IS BASED IN CONTRAC
T
, WARRANT
Y
,
N
EGLIGENCE OR STRICT LIABILIT
Y
.  
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.  
Suitability of Use.  
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the  
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable  
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is  
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,  
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with  
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.  
NEVER USE THE PRODUCT FOR AN APPLIC
A
T
ION INVO
L
V
ING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  
QUANTITIES WITHOUT ENSURING TH
A
T
T
HE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,  
AND TH
A
T
T
HE OMRON PRODUCT(S) IS PROPER
L
Y
R
A
T
ED AND INS
T
A
LLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Programmable Products.  
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.  
Performance Data.  
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining  
suitability and does not constitute a warrant
y
.
I
t may represent the result of Omron’s test conditions, and the user must correlate it  
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liabilit
y
.  
Change in Specifications.  
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice  
to change part numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be  
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to  
confirm actual specifications of purchased Product.  
Errors and Omissions.  
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  

OMRON Corporation  
Kyoto, JAPAN  
Industrial Automation Company  
Authorized Distributor:  
Regional Headquarters  
OMRON EUROPE B.
V
.  
Wegalaan 67-69, 2132 JD Hoofddorp  
The Netherlands  
OMRON ELECTRONICS LLC  
2895 Greenspoint Parkwa
y
,
S
uite 200  
Hoffman Estates, IL 60169 U.S.A.  
T
e
l: (31)2356-81-300/Fax: (31)2356-81-388  
T
e
l: (1) 847-843-7900/Fax: (1) 847-843-7787  
© OMRON Corporation 2016-2017
 
All Rights Reserved.  
In the interest of product improvement,  
specifications are subject to change without notice.  
OMRON (CHINA) CO., LTD.  
Room 2211, Bank of China
T
o
wer,  
200 Yin Cheng Zhong Road,  
OMRON ASIA
P
ACIFIC PTE. LTD.  
No. 438A Alexandra Road # 05-05/08 (Lobby 2),  
Alexandra
T
e
chnopark,  
PuDong New Area, Shanghai, 200120, China  
T
e
l: (86) 21-5037-2222/Fax: (86) 21-5037-2200  
CSM_
6
_
4
_
12
17  
Cat. No. J214-E1-02  
Singapore 119967  
T
e
l: (65) 6835-3011/Fax: (65) 6835-2711  
0617(0316)