Omron-Electronics-G4A-1A-E-DC5

Part #Omron-Electronics-G4A-1A-E-DC5
Download 
Omron-Electronics-G4A-1A-E-DC5
G4A  
PCB Power Relay  
Miniature Single-pole Relay with  
80A Surge Current and 20A  
Switching Current  
• Capable of Switching Motor Load of 80-A Surge Current and 20A  
Switching/Cut-off Current  
• Miniature, relay with high switching power and long endurance.  
• Creepage distance conforms to UL and CSA standards.  
• Highly noise-resistive insulation materials employed.  
• Standard model available with flux protection construction.  
RoHS Compliant  
■
Model Number Legend  
G4A-
@
@
–
@
–
@  
■
Application Examples  
• Air
 
conditioner  
— —  
—
—
1 2  
3
4
1. Number
 
of Poles  
3. Terminal
 
Shape  
Non
e
:
#
250 quick-connect/  
PCB coil terminals  
4. Special
 
Function  
E: For long endurance  
1: 1-pole  
G
4
A
2. Contact
 
Form  
A: SPS
T
–
NO (1a)  
P
: PCB terminals/  
PCB coil terminals  
■
Ordering Information  
■
Characteristics  
●
Quick-connect/PCB coil terminals  
Contact resistance *1  
Operate time  
Release time  
Max.  
100 m
Ω
max.  
20 ms max.  
10 ms max.  
Minimum  
Contact form
 
Load Contact
T
e
rminal
 
Coil terminal  
Model  
Rated voltage  
12, 24 VDC  
packing unit  
SPS
T
–
NO  
(1a)  
#250 quick-connect  
terminals  
PCB terminals  
G4A-1A-E  
50 pcs/tray  
operating  
frequency  
Mechanical  
18,000 operations/hr  
●
PCB terminals  
Insulation resistance *2  
1,000 M
Ω
min.  
4,500 VAC 50/60 Hz for  
1 min  
Minimum  
packing unit  
Between coil  
and contacts  
Contact form
 
Load Contact
T
e
rminal
 
Coil terminal  
SPS
T
–
NO  
Model  
Rated voltage  
12, 24 VDC  
Dielectric  
strength  
PCB terminals  
PCB terminals  
G4A-1A-PE  
50 pcs/tray  
Between  
contacts of  
the same  
polarity  
(1a)  
1,000 VAC 50/60 Hz for  
1 min  
Note. When ordering, add the rated coil voltage to the model number.  
Example: G4A-1A-E DC12  
Impulse  
withstand  
voltage  
Rated coil voltage  
Between coil  
and contacts  
8.5 kV (1.2 x 50
μ
s)  
However, the notation of the coil voltage on the product case as well as on the packing will be marked  
as
@@
VDC.  
Insulation Between
 
coil
Clearance: 3.2 mm,  
distance  
and contacts
 
Creepage: 6.4 mm  
10 to 55 to 10 Hz,  
Destruction  
Malfunction  
■
Ratings  
0.75 mm single amplitude  
(1.5 mm double amplitude)  
Vibration  
resistance  
●
Coil  
10 to 55 to 10 Hz,  
Item  
Must operate voltage
 
Must release voltage
 
Max. permissible voltage  
Rated  
current  
(mA)  
Coil  
0.75 mm single amplitude  
Power consumption  
(W)  
(V)  
(V)  
(V)  
resistance  
(1.5 mm double amplitude)  
Rated voltage  
(
Ω
)  
% of rated voltage  
Destruction  
Malfunction  
1,000 m/s

2  

200 m/s

2  

2,000,000 operations min.  
(at 18,000 operations/hr)  
100,000 operations min.  
(ON/OFF: 1 s)  
200,000 operations min.  
(ON/OFF: 1.5 s)  
Shock  
resistance  
12 VDC  
24 VDC  
75  
37.5  
160  
640  
160%  
(at 23°C)  
70% max.  
10% min.  
0.9  
Mechanical  
Note 1. The rated current and coil resistance are  
●
Motor Ratings  
measured at a coil temperature of 23  
with a tolerance of
 
10%.  
°
C  
Resistive  
load  
Switching  
frequency  
Electrical  
durability  
Load conditions  
Durability  
2. The inductances shown above are  
reference values.  
3. Operating characteristics are measured at  
a coil temperature of 23 C.  
4. Max. permissible voltage refers to the  
maximum value in a varying range of  
operating power voltage, not a continuous  
voltage.  
Motor load  
250 VAC:  
Inrush current: 80 A,  
ON: 1.5 s  
OFF: 1.5 s  
200,000  
operations  
30,000 operations min.  
(ON: 3 s, OFF: 5 s)  
°
0.3 s (cos
φ
= 0.7)  
Inverter load  
Break current: 20 A  
(cos =
 
0.9)  
Failure rate (P level)  
(reference value *3)  
Ambient operating  
temperature  
Ambient operating humidity
 
5% to 85%  
Weight Approx.
 
23 g  
φ
100 mA at 5 VDC  
●
Inverter Ratings  
-20°C to 60°C (with no icing  
or condensation)  
Switching  
frequency  
Electrical  
durability  
●
Contacts  
Load conditions  
Load  
100 VAC:  
Resistive load  
Single  
Ag-Alloy (Cd free)  
20 A at 250 VAC  
20 A  
Inrush current:  
200 A (0.P)  
ON: 3 s  
OFF: 5 s  
30,000  
operations  
Note. The data given above are initial values.  
*1. Measurement
 
conditions: 5 VDC, 1 A, voltage  
drop method.  
*2. Measurement
 
conditions: The insulation  
resistance was measured with a 500 VDC  
megohmmeter at the same locations as the  
dielectric strength was measured.  
*3. This
 
value was measured at a switching  
frequency of 120 operations/min.  
Item  
Break current: 20 A  
Contact type  
Contact material  
Rated load  
Rated carry current  
Max. switching voltage  
Max. switching current  
●
Overload Durability (Reference Value)  
Switching  
frequency  
Electrical  
durability  
Load conditions  
250 VAC  
20 A  
250 VAC:  
Inrush current: 80 A  
Break current: 80 A  
ON: 1.5 s  
OFF: 99 s  
1,500  
operations  
(cos
φ
= 0.7)  
1

G4A  
PCB Power Relay  
■
Engineering Data  
●
Maximum Switching Capacity  
G4A-1A-(P)E  
●
Durability  
G4A-1A-(P)E  
●
Ambient Temperature vs.  
Maximum Coil Voltage  
G4A-1A-(P)E  
100  
70  
100  
90  
180  
50  
160  
80  
70  
60  
50  
40  
30  
20  
10  
30  
AC load  
140  
120  
100  
250 VAC resistive load  
10  
7
5
3
1
80  
0
1
3
5
10  
30 50
 
100  
300 50
0
1
,000  
0
5
10  
15  
20  
25  
-25  
0
10  
20  
30  
40  
50  
60  
70 80  
Switching voltage (V)  
Switching current (A)  
Ambient temperature (°C)  
Note. The maximum coil voltage is the maximum  
voltage that can be applied to the relay coil.  
●
Ambient Temperature vs. Must  
Operate and Must Release
V
o
ltages  
G4A-1A-(P)E  
●
Shock Malfunction  
G4A-1A-(P)E  
Number of Relays: 5 pcs  
Y
100  
1,000  
Must Operating voltage  
Must Recovery voltage  
Sample:  
G4A-1A-E DC12V  
Number of Relays: 5 pcs  
800  
1,000  
X
1,000  
Z’  
80  
60  
40  
20  
600  
400  
200  
G
4
A
Test conditions
:
S
hock is applied in ±±, ±ꢀ, ±ꢁ  
directions three times each with  
and without energizing the Relays  
to check the number of  
malfunctions.  
Requirement: 200
 
m/s

2  

200  
400  
600  
Shock direction  
Z
X’  
X
1,000  
1,000  
X’  
800  
Y
Z
contact A  
1,000  
Unit: m/s

2  

Y’  
Z’  
Y’  
0
-60  
-40  
-20  
0
20  
40  
60  
80 100  
Ambient temperature (°C)  
■
Dimensions  
Mounting Holes  
30.ꢀ max.  
(30.1)*  
#250 quick-connect/PCB coil terminals  
G4A-1A-E  
(Bottom View)  
Four, 1.8

+
0.1

dia.  
0
16 max.  
(1ꢀ.7)*  
0.1  
6.2ꢀ  
0.1  
ꢀ.7ꢀ  
0.0ꢀ  
0.8  
0.8  
6.3ꢀ  
12  
0.1  
22  
8
0.1  
27.6  
Terminal Arrangement/Internal Connections  
3.4  
(Top View) (Bottom View)  
2
23.ꢀ max.  
(23.3)*  
4
3
3
1
2
1
0.3  
1.ꢀ  
1.ꢀ  
0.8  
4
3.ꢀ  
* Average value  
Tab Terminal  
PCB Terminal  
(No coil polarity)  
PCB Mounting Holes  
30.5 max.  
(30.1)*  
Straight PCB/PCB coil terminals  
G4A-1A-PE  
(Bottom View)  
Four, 1.8

+
0.1

dia.  
0
16 max.  
(15.7)*  
9.4  
0.1  
0.1  
6.25  
5.75  
0.05  
12  
0.1  
22  
0.1  
27.6  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
26.8 max.  
(26.5)*  
23.3  
4
3
1
2
1
0.3  
1.5  
1.5  
3.5  
0.8  
* Average value  
(No coil polarity)  
2

G4A  
PCB Power Relay  
■
Approved Standards  
●
The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in  
this datasheet.  
UL Recognized  
(File No. E41643)  
CSA Certified  
(File No. LR31928)  
Number of  
poles  
Number of test  
operations  
Number of  
poles  
Number of test  
operations  
Model  
Coil ratings  
Contact ratings  
Model  
Coil ratings  
Contact ratings  
20 A, 250 VAC (Resistive)  
40°C  
20 A, 250 VAC (Resistive)  
40°C  
100,000  
10,000  
15 A, 30 VDC (Resistive)  
40°C  
15 A, 30 VDC (Resistive)  
40°C  
G4A-1A-E  
G4A-1A-PE  
SPS
T
–
NO  
(1a)  
G4A-1A-E  
G4A-1A-PE  
SPS
T
–
NO  
(1a)  
12 to 24 VDC  
12 to 24 VDC  
23 A, 277 VAC (General  
Purpose) 40°C  
23 A, 277 VAC (General  
Purpose) 40°C  
30,000  
25,000  
30,000  
25,000  
TV-15 120 V AC 40°C  
TV-15 120 V AC 40°C  
EN/IEC, VDE Certified  
(Certificate No. 107293)  
Number of  
poles  
SPS
T
–
NO  
(1a)  
Number of test  
operations  
Model  
Coil ratings  
12, 24 VDC  
Contact ratings  
G4A-1A-E  
G4A-1A-PE  
20 A, 250 VAC (cos
φ
=1.0)  
100,000  
50°C  
■
Precautions  
●
Please refer to “PCB Relays Common Precautions” for correct use.  
Correct Use  
G
4
A
●
Mounting  
●
Terminals  
●
Other Precautions  
• When
 
mounting more than two Relays  
side by side, keep a 3 mm gap  
horizontally and vertically between  
Relays to ensure a good heat  
dissipation. It may cause a malfunction  
if heat is not dissipated smoothly from  
the Rela
y
.  
• The
 
terminals fit FASTON receptacle  
250 and are suitable for positive-lock  
mounting. Use only Faston terminals  
with the specified numbers.  
• This
 
Relay is suitable for power load  
switching of air-conditioning  
compressors and power supplies, etc.  
Do not use the G4A to switch micro  
loads less than 100 mA, such as in  
signal applications.  
Select leads for connecting Faston  
receptacles with wire diameters that  
are within the allowable range for the  
load current.  
Do not apply excessive force to the  
terminals when mounting or  
dismounting the Faston receptacle.  
Insert and remove terminals carefully  
one at a time. Do not insert terminals  
at an angle, or insert/remove multiple  
terminals at the same time.  
Refer to the following table for  
recommendations of connectors made  
by OMRON.  
Receptacle  
terminals  
T
y
pe  
Housing  
±T3W-S441-12  
±T3W-S442-12  
±T3W-S443-12  
±T3B-1S white  
#250 terminals  
(width: 6.35 mm)  
3

G4A  
PCB Power Relay  
G
4
A
•
Application examples pro
v
ided in this doc
u
ment are for reference only. In act
u
al applications, confirm e
qu
ipment f
u
nctions and safety
b
efore
u
sing the prod
u
ct.  
•
Cons
u
lt yo
u
r OMRO
N
representati
v
e
b
efore
u
sing the prod
u
ct
u
nder conditions
w
hich are not descri
b
ed in the man
u
al or applying the prod
u
ct to n
u
clear control systems, railroad  
systems, a
v
iation systems,
v
ehicles, com
bu
stion systems, medical e
qu
ipment, am
u
sement machines, safety e
qu
ipment, and other systems or e
qu
ipment that may ha
v
e a serio
u
s  
infl
u
ence on li
v
es and property if
u
sed improperly. Make s
u
re that the ratings and performance characteristics of the prod
u
ct pro
v
ide a margin of safety for the system or  
e
qu
ipment, and
b
e s
u
re to pro
v
ide the system or e
qu
ipment
w
ith do
ub
le safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Cat. No. J056-E1-09  
1116(0207)(O)  
4