Omron-Electronics-G5NB-1A4-E-DC24
| Part # | Omron-Electronics-G5NB-1A4-E-DC24 |
| Download | Omron-Electronics-G5NB-1A4-E-DC24 |
G5NB
PCB Power Relay
A Miniature Relay with 1-pole
3A/5A Switching Capability and
10 kV Impulse Withstand Voltage
• Highly efficient magnetic circuit for high sensitivity (200 mW).
• Standard model conforms to UL/CSA/VDE standards.
• Satisfies EN61010 reinforced insulation requirements.
• IEC/EN 60335-1 conformed. (-HA Model)
• IEC/EN 60079-15 conformed.
(Only for G5NB-1A4, G5NB-1A4-E Model)
• Reduced power consumption with voltage holding and pulse width
modulation (PWM) control (Only for G5NB-
@
-PW model)
RoHS Compliant
■
Model Number Legend
G5NB-
@
@@
–
@
–
@
–
@
–
@
–
@
G
5
— — —
—
—
—
—
—
1 2 3
4
5
6
7
8
N
B
1. Number
of Poles
: 1-pole
2. Contact
Form
4. Classification
None : Standard
6. Coil
Insulation Class(UL1446)
None : Class B
CF :
Class F
8. Packing
None : Tray Packing
SP :
Tube Packing
1
E
: High-capacity
A
: SPST-NO (1a)
5. Market
Code
7. Special
Requirement
None : Not supported
PW :
Supported
None : General purpose
HA :
Home Appliance according
to IEC/EN60335-1
3. Enclosure
rating
None : Flux protection
4
: Sealed
■
Application Examples
• Water heaters
• Refrigerators
• Air conditioners
• Home appliances
• Small electric appliances
■
Ordering Information
Terminal Shape Market Code
Classification
Contact form
Enclosure rating
Model
G5NB-1A(-SP)
Rated coil voltage
Minimum packing unit
5VDC
Flux protection
Sealed
12VDC
18VDC
24VDC
G5NB-1A4(-SP)
Standard
G5NB-1A-CF(-SP)
G5NB-1A-CF-PW(-SP)
G5NB-1A-PW(-SP)
5VDC
General
purpose
12VDC
24VDC
Flux protection
Sealed
5VDC
G5NB-1A-E(-SP)
G5NB-1A4-E(-SP)
100 pcs/Tray
12VDC
PCB terminals
High-capacity
SPST-NO (1a)
(50 pcs/Tube)
18VDC
24VDC
G5NB-1A-HA(-SP)
5VDC
12VDC
24VDC
G5NB-1A-HA-CF(-SP)
G5NB-1A-HA-CF-PW(-SP)
G5NB-1A-HA-PW
Standard
Home
Appliance
Flux protection
12VDC
24VDC
High-capacity
G5NB-1A-E-HA(-SP)
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G5NB-1A DC5
Rated coil voltage
However, the notation
of the coil voltage
on the product case as well as on the packing will be marked as
@@
VDC.
Note 2. When ordering tape packing, add “-SP” to the model number.
Be sure since “-SP” is not part of the relay model number, it is not marked on the relay case.
1
G5NB
PCB Power Relay
■
Ratings
●
Coil
Item
Must operate voltage Must release voltage
Max. voltage
(V)
Rated current
(mA)
Coil resistance
Power consumption
(mW)
(V)
(V)
(
Ω
)
Rated voltage
5 VDC
% of rated voltage
40
125
720
1,620
2,880
Standard:
12 VDC
18 VDC
24 VDC
16.7
11.1
8.3
10% min.
10 to 31%*
180% (at 23°C)
High-capacity:
170% (at 23°C)
Approx. 200
Approx. 32*
75% max.
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
*
These numbers are only for -PW type. Power consumption with Holding Voltage is 32mW. Please confirm the detail in page 6 Coil Voltage Reduction (Holding
Voltage).
●
Contacts
Resistive load
Item
Load
Standard
High-capacity
Contact Type
Single
Contact material
Ag-alloy (Cd free)
3 A at 125 VAC
3 A at 30 VDC
3 A
5 A at 250 VAC
3 A at 30 VDC
5 A
Rated load
Rated carry current
Max. switching voltage
Max. switching current
250 VAC, 30 VDC
3 A
5 A
G
5
■
Characteristics
■
Actual Load Life (Reference Values)
1.
120 VAC
motor and lamp load
N
B
Contact resistance *1
Operate time
Release time
100 m
Ω
max.
10 ms max.
10 ms max.
2.5A surge and 0.5A normal:
250,000 operations min. (at 23°C)
2.
160 VDC
valve load (with varistor)
0.24A:
250,000 operations min. (at 23°C)
3.
140 VAC
pump load
Inrush: 5.4 A (o-p), Steady state: 1.6 A
200,000 operations min. (Ambient temperature: 23°C)
4.
100 VAC
motor load
Insulation resistance *2
Between coil
1,000 M
Ω
min.
4,000 VAC, 50/60 Hz for 1 min
and contacts
Dielectric
strength
Between
contacts of the
750 VAC, 50/60 Hz for 1 min
same polarity
Impulse
withstand
voltage
Between coil
10 kV (1.2 x 50
μ
s)
and contacts
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Destruction
Malfunction
Vibration
Inrush: 10.7 A (o-p), Steady state: 1.1 A
200,000 operations min. (Ambient temperature: 23°C)
resistance
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Destruction
Malfunction
Mechanical
1,000 m/s
2
Shock
resistance
100 m/s
2
5,000,000 operations min.
Standard (G5NB-1A, -1A4)
200,000 operations at 125 VAC, 3A
200,000 operations at 30 VDC, 3A
High-capacity (G5NB-1A-E, -1A4-E)
100,000 operations at 250 VAC, 5A
200,000 operations at 30 VDC, 3A
(with a rated load at 1,800 operations/hour)
Durability
Electrical
(resistive load)
Failure rate (P level)
(reference value) *3
Ambient operating
temperature
DC5V 10mA
-40°C to 85°C
(with no icing or condensation)
Ambient operating humidity
5% to 85%
Weight Approx.
4 g
Note. Values in the above table are the initial values at 23°C.
*1. Measurement
conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement
conditions: Measured at the same points as the dielectric
strength using a 500 VDC ohmmeter.
*3. This
value was measured at a switching frequency of 120 operations/min.
2
G5NB
PCB Power Relay
■
Engineering Data
●
Maximum Switching Capacity
Standard models
High-capacity models
10
AC resistive
load
3
DC resistive
load
AC resistive
load
DC resistive
load
1
0.1
1
10
30
100 250 1,000
Switching voltage (V)
Switching voltage (V)
●
Durability
Standard models
High-capacity models
100
125 VAC, 30 VDC resistive load
G
5
50
30
N
B
30VDC resistive load
10
250VAC resistive load
5
3
1
0
1
2
3
4
Switching current (A)
Switching current (A)
●
Ambient Temperature vs. Maximum Coil Voltage
Standard models
High-capacity models
220
220
T
e
st item: G5NB-1A, 24 VDC
Number of Relays: 5 pcs
T
e
st Item: G5NB-1A-E,24 VDC
Number of Relays: 5 pcs
Uncon-
firmed
area
Uncon-
200
200
180
160
140
120
firmed
area
5A current
3A current
180
160
140
120
100
80
100
80
0
2
0
2
3
40
60
8
0
8
5 100
20 23
0
40
60
8085
100
Ambient temperature (
°
C)
Ambient temperature (
°
C)
Note:
The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage.
3
G5NB
PCB Power Relay
●
Shock malfunction
Standard models
High-capacity models
Y
Y
1,000
1,000
Energized
De-energized
Energized
De-energized
Test Item: G5NB-1A, 24VDC
Number of Relays: 5 pcs
Test Item: G5NB-1A-E, 24VDC
Number of Relays: 5 pcs
7
0
0
7
0
0
1,000
1,000
Z’
1,000
1,000
Z’
X
X
Test Method: Shock is applied 3
times in 6 directions along 3 axes
and the level at which shock caused
malfunction is measured.
Test Method: Shock is applied 3
times in 6 directions along 3 axes
and the level at which shock caused
malfunction is measured.
The energized voltage is 100% of
the rated voltage.
Rating: 100 m/s
2
The energized voltage is 100% of
the rated voltage.
Rating: 100 m/s
2
125
125
Z
X’
1,000
Z
X’
1,000
1,000
1,000
1,000
1,000
Y’
Unit: m/s
2
Y’
Unit: m/s
2
Shock direction
Shock direction
X X’
X
X’
Y
Y
Z
Z
Z’
Z’
Y’
Y’
■
Dimensions
(Unit: mm)
G5NB-1A(4)(-E)(-HA)(-CF)(-PW)
G
5
7.2max.
(7.0)*
PCB Mounting Holes
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
20.5max.
(20.4)*
N
B
Tolerance: ±0.1 mm
(1.05)
11.5
7
Fo
u
r, 1.1 dia.
15.3max.
(15.0)*
(1.15)
1
4
2
3
4.7
3.4
0.4
(No coil polarity)
0.27
0.33
0.
8
11.5
7
4.7
*A
v
erage
v
al
u
e
4
G5NB
PCB Power Relay
■
Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values
before use.
●
UL Recognized:
CSA Certified:
(File No. E41515)
(File No. LR31928)
Number of test
operations
Model
Contact form
Coil ratings
Contact ratings
3A 250V AC (Resistive) 85°C
3A 30V DC (Resistive) 70°C
100,000
6,000
G5NB-1A(4)(-HA)(-CF)(-PW)
SPST-NO
(1a)
5 to 24V DC
G5NB-1A(4)-E
G5NB-1A-E-HA
5A 250 V AC (Resistive) 85°C
5A 30 V DC (Resistive) 70°C
6,000
●
EN/IEC, VDE Certified
(Certificate No. 137575)
Number of test
operations
Model
Contact form
Coil ratings
Contact ratings
3A 250V
AC (Resistive) 85°C
3A 30V
DC (Resistive) 85°C
G5NB-1A(4)(-HA)(-CF)(-PW)
100,000
10,000
SPST-NO
(1a)
5A 250 V AC (Resistive) 85°C
5A 30 V DC (Resistive) 85°C
5, 12, 18, 24V DC
G5NB-1A(4)-E
G5NB-1A-E-HA
G
5
3A 250V AC (Resistive) 85°C
100,000
N
B
Creepage distance
6.0 mm min.
6.0 mm min.
IIIa
Clearance distance
Insulation material group
Pollution degree 2 / Reinforced (Sealed)
Type of insulation coil-contact circuit
open contact circuit
Pollution degree 3 / Basic (Flux protection) / Reinforced (Sealed)
Micro disconnection
Rated Insulation voltage
Pollution degree
250 V
3
Rated voltage system
Over voltage category
250 V
III
Category of protection according to IEC 61810-1
RT II (Flux protection) / RT III (Sealed)
<HA Models only>
GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)
Glow wire
according to IEC 60335-1
Tracking resistance
according to IEC 60112
Flammability class according to UL94
PTI 250 V min. (housing parts)
V-0
5
G5NB
PCB Power Relay
■
Precautions
●
Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●
Coil Voltage Reduction (Holding Voltage) after Relay
Operation
●
Power consumption reduction of coil with pulse width
modulation (PWM)
• If the coil voltage is reduced to the holding voltage after Relay
operation, first apply the rated voltage to the coil for at least
100 ms, as shown below.
• Models
with PWM drive capability (-PW) can reduce coil
holding current with PWM control. This function reduces power
consumption by reducing the current held by coil.
• Apply the rated voltage for at least 100 ms at the time of relay
operation.
• A voltage of at least 40% of the rated voltage is required for
the coil holding voltage. Do not allow voltage fluctuations to
cause the coil holding voltage to fall below this level.
• The following are our verification conditions. When using, it be
sure to check the actual machine under the actual usage
conditions.
100%
(Rated voltage)
■
Example of drive circuit
■
Conditions of validation
40%
(Holding voltage)
carried out by OMRON
Applied coil voltage (100%)
• Applied voltage: rated voltage
100ms min.
• Duty: 50% or more
Applied
Power
consumption
• Frequency: 10 kHz or more
Surge
Coil resistance*
Relay
• Diode Vf: 0.4 V or less
absorption
coil voltage
Coil
diode
125
Ω
(5 VDC)
720
Ω
(12 VDC)
2880
Ω
(24 VDC)
Rated voltage
100%
40%
Approx. 200 mW
Approx. 32 mW
MOS-FET
Holding voltage
Pulse input
*
The coil resistance were measured at a coil temperature of 23°C with
tolerances of ± 10%.
G
5
N
B
Please check each region’s Terms & Conditions by region website.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
Europe
Asia-Pacific
China
Korea
Japan
© OMRON Corporation 2007-2021
All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No.
J143-E1-17
0521(0207)
6