Omron-Electronics-G5NB-1A4-E-DC24

Part #Omron-Electronics-G5NB-1A4-E-DC24
Download 
Omron-Electronics-G5NB-1A4-E-DC24
G5NB  
PCB Power Relay  
A Miniature Relay with 1-pole  
3A/5A Switching Capability and  
10 kV Impulse Withstand Voltage  
• Highly efficient magnetic circuit for high sensitivity (200 mW).  
• Standard model conforms to UL/CSA/VDE standards.  
• Satisfies EN61010 reinforced insulation requirements.  
• IEC/EN 60335-1 conformed. (-HA Model)  
• IEC/EN 60079-15 conformed.
(Only for G5NB-1A4, G5NB-1A4-E Model)  
• Reduced power consumption with voltage holding and pulse width  
modulation (PWM) control (Only for G5NB-
@
-PW model)  
RoHS Compliant  
■
Model Number Legend  
G5NB-
@
@@
–
@
–
@
–
@
–
@
–
@  
G
5
— — —  
—
—
—
—
—
1 2 3  
4
5
6
7
8
N
B
1. Number
 
of Poles  
: 1-pole  
2. Contact
 
Form  
4. Classification  
None : Standard  
6. Coil
 
Insulation Class(UL1446)  
None : Class B  
CF :
 
Class F  
8. Packing  
None : Tray Packing  
SP :
 
Tube Packing  
1
E
: High-capacity  
A
: SPST-NO (1a)  
5. Market
 
Code  
7. Special
 
Requirement  
None : Not supported  
PW :
 
Supported  
None : General purpose  
HA :
 
Home Appliance according  
to IEC/EN60335-1  
3. Enclosure
 
rating  
None : Flux protection  
4
: Sealed  
■
Application Examples  
• Water heaters  
• Refrigerators  
• Air conditioners  
• Home appliances  
• Small electric appliances  
■
Ordering Information  
Terminal Shape Market Code
 
Classification  
Contact form  
Enclosure rating  
Model  
G5NB-1A(-SP)  
Rated coil voltage
 
Minimum packing unit  
5VDC  
Flux protection  
Sealed  
12VDC  
18VDC  
24VDC  
G5NB-1A4(-SP)  
Standard  
G5NB-1A-CF(-SP)  
G5NB-1A-CF-PW(-SP)  
G5NB-1A-PW(-SP)  
5VDC  
General  
purpose  
12VDC  
24VDC  
Flux protection  
Sealed  
5VDC  
G5NB-1A-E(-SP)  
G5NB-1A4-E(-SP)  
100 pcs/Tray  
12VDC  
PCB terminals  
High-capacity  
SPST-NO (1a)  
(50 pcs/Tube)  
18VDC  
24VDC  
G5NB-1A-HA(-SP)  
5VDC  
12VDC  
24VDC  
G5NB-1A-HA-CF(-SP)  
G5NB-1A-HA-CF-PW(-SP)  
G5NB-1A-HA-PW  
Standard  
Home  
Appliance  
Flux protection  
12VDC  
24VDC  
High-capacity  
G5NB-1A-E-HA(-SP)  
Note 1. When ordering, add the rated coil voltage to the model number.  
Example: G5NB-1A DC5  
Rated coil voltage  
However, the notation
 
of the coil voltage
 
on the product case as well as on the packing will be marked as
@@
VDC.  
Note 2. When ordering tape packing, add “-SP” to the model number.  
Be sure since “-SP” is not part of the relay model number, it is not marked on the relay case.  
1

G5NB  
PCB Power Relay  
■
Ratings  
●
Coil  
Item  
Must operate voltage Must release voltage  
Max. voltage  
(V)  
Rated current  
(mA)  
Coil resistance  
Power consumption  
(mW)  
(V)  
(V)  
(
Ω
)  
Rated voltage  
5 VDC  
% of rated voltage  
40  
125  
720  
1,620  
2,880  
Standard:  
12 VDC  
18 VDC  
24 VDC  
16.7  
11.1  
8.3  
10% min.  
10 to 31%*  
180% (at 23°C)  
High-capacity:  
170% (at 23°C)  
Approx. 200  
Approx. 32*  
75% max.  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.  
Note 2. The operating characteristics are measured at a coil temperature of 23°C.  
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.  
*
These numbers are only for -PW type. Power consumption with Holding Voltage is 32mW. Please confirm the detail in page 6 Coil Voltage Reduction (Holding  
Voltage).  
●
Contacts  
Resistive load  
Item  
Load  
Standard  
High-capacity  
Contact Type  
Single  
Contact material  
Ag-alloy (Cd free)  
3 A at 125 VAC  
3 A at 30 VDC  
3 A  
5 A at 250 VAC  
3 A at 30 VDC  
5 A  
Rated load  
Rated carry current  
Max. switching voltage  
Max. switching current  
250 VAC, 30 VDC  
3 A  
5 A  
G
5
■
Characteristics  
■
Actual Load Life (Reference Values)  
1.
120 VAC
motor and lamp load  
N
B
Contact resistance *1  
Operate time  
Release time  
100 m
Ω
max.  
10 ms max.  
10 ms max.  
2.5A surge and 0.5A normal:  
250,000 operations min. (at 23°C)  
2.
160 VDC
valve load (with varistor)  
0.24A:  
250,000 operations min. (at 23°C)  
3.
140 VAC
pump load  
Inrush: 5.4 A (o-p), Steady state: 1.6 A  
200,000 operations min. (Ambient temperature: 23°C)  
4.
100 VAC
motor load  
Insulation resistance *2  
Between coil  
1,000 M
Ω
min.  
4,000 VAC, 50/60 Hz for 1 min  
and contacts  
Dielectric  
strength  
Between  
contacts of the
 
750 VAC, 50/60 Hz for 1 min  
same polarity  
Impulse  
withstand  
voltage  
Between coil  
10 kV (1.2 x 50
μ
s)  
and contacts  
10 to 55 to 10 Hz, 0.75 mm single amplitude  
(1.5 mm double amplitude)  
Destruction  
Malfunction  
Vibration  
Inrush: 10.7 A (o-p), Steady state: 1.1 A  
200,000 operations min. (Ambient temperature: 23°C)  
resistance  
10 to 55 to 10 Hz, 0.75 mm single amplitude  
(1.5 mm double amplitude)  
Destruction  
Malfunction  
Mechanical  
1,000 m/s

2  

Shock  
resistance  
100 m/s

2  

5,000,000 operations min.  
Standard (G5NB-1A, -1A4)  
200,000 operations at 125 VAC, 3A  
200,000 operations at 30 VDC, 3A  
High-capacity (G5NB-1A-E, -1A4-E)  
100,000 operations at 250 VAC, 5A  
200,000 operations at 30 VDC, 3A  
(with a rated load at 1,800 operations/hour)  
Durability  
Electrical  
(resistive load)  
Failure rate (P level)  
(reference value) *3  
Ambient operating  
temperature  
DC5V 10mA  
-40°C to 85°C  
(with no icing or condensation)  
Ambient operating humidity
 
5% to 85%  
Weight Approx.
 
4 g  
Note. Values in the above table are the initial values at 23°C.  
*1. Measurement
 
conditions: 5 VDC, 1 A, voltage drop method  
*2. Measurement
 
conditions: Measured at the same points as the dielectric  
strength using a 500 VDC ohmmeter.  
*3. This
 
value was measured at a switching frequency of 120 operations/min.  
2

G5NB  
PCB Power Relay  
■
Engineering Data  
●
Maximum Switching Capacity  
Standard models  
High-capacity models  
10  
AC resistive  
load  
3
DC resistive  
load  
AC resistive  
load  
DC resistive  
load  
1
0.1  
1
10  
30  
100 250 1,000  
Switching voltage (V)  
Switching voltage (V)  
●
Durability  
Standard models  
High-capacity models  
100  
125 VAC, 30 VDC resistive load  
G
5
50  
30  
N
B
30VDC resistive load  
10  
250VAC resistive load  
5
3
1
0
1
2
3
4
Switching current (A)  
Switching current (A)  
●
Ambient Temperature vs. Maximum Coil Voltage  
Standard models  
High-capacity models  
220  
220  
T
e
st item: G5NB-1A, 24 VDC  
Number of Relays: 5 pcs  
T
e
st Item: G5NB-1A-E,24 VDC  
Number of Relays: 5 pcs  
Uncon-  
firmed  
area  
Uncon-  
200  
200  
180  
160  
140  
120  
firmed  
area  
5A current  
3A current  
180  
160  
140  
120  
100  
80  
100  
80  
0
2
0
2
3  
40  
60  
8
0
8
5 100  
20 23  
0
40  
60  
8085  
100  
Ambient temperature (
°
C)  
Ambient temperature (
°
C)  
Note:
The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage.  
3

G5NB  
PCB Power Relay  
●
Shock malfunction  
Standard models  
High-capacity models  
Y
Y
1,000  
1,000  
Energized  
De-energized  
Energized  
De-energized  
Test Item: G5NB-1A, 24VDC  
Number of Relays: 5 pcs  
Test Item: G5NB-1A-E, 24VDC  
Number of Relays: 5 pcs  
7
0
0  
7
0
0  
1,000  
1,000  
Z’  
1,000  
1,000  
Z’  
X
X
Test Method: Shock is applied 3  
times in 6 directions along 3 axes  
and the level at which shock caused  
malfunction is measured.  
Test Method: Shock is applied 3  
times in 6 directions along 3 axes  
and the level at which shock caused  
malfunction is measured.  
The energized voltage is 100% of  
the rated voltage.  
Rating: 100 m/s

2  

The energized voltage is 100% of  
the rated voltage.  
Rating: 100 m/s

2  

125  
125  
Z
X’  
1,000  
Z
X’  
1,000  
1,000  
1,000  
1,000  
1,000  
Y’  
Unit: m/s

2  

Y’  
Unit: m/s

2  

Shock direction  
Shock direction  
X X’  
X
X’  
Y
Y
Z
Z
Z’  
Z’  
Y’  
Y’  
■
Dimensions  
(Unit: mm)  
G5NB-1A(4)(-E)(-HA)(-CF)(-PW)  
G
5
7.2max.  
(7.0)*  
PCB Mounting Holes  
(Bottom View)  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
20.5max.  
(20.4)*  
N
B
Tolerance: ±0.1 mm  
(1.05)  
11.5  
7
Fo
u
r, 1.1 dia.  
15.3max.  
(15.0)*  
(1.15)  
1
4
2
3
4.7  
3.4  
0.4  
(No coil polarity)  
0.27  
0.33  
0.
8  
11.5  
7
4.7  
*A
v
erage
v
al
u
e  
4

G5NB  
PCB Power Relay  
■
Approved Standards  
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values  
before use.  
●
UL Recognized:  
CSA Certified:  
(File No. E41515)  
(File No. LR31928)  
Number of test  
operations  
Model  
Contact form  
Coil ratings  
Contact ratings  
3A 250V AC (Resistive) 85°C  
3A 30V DC (Resistive) 70°C  
100,000  
6,000  
G5NB-1A(4)(-HA)(-CF)(-PW)  
SPST-NO  
(1a)  
5 to 24V DC  
G5NB-1A(4)-E  
G5NB-1A-E-HA  
5A 250 V AC (Resistive) 85°C  
5A 30 V DC (Resistive) 70°C  
6,000  
●
EN/IEC, VDE Certified  
(Certificate No. 137575)  
Number of test  
operations  
Model  
Contact form  
Coil ratings  
Contact ratings  
3A 250V
 
AC (Resistive) 85°C  
3A 30V
 
DC (Resistive) 85°C  
G5NB-1A(4)(-HA)(-CF)(-PW)  
100,000  
10,000  
SPST-NO  
(1a)  
5A 250 V AC (Resistive) 85°C  
5A 30 V DC (Resistive) 85°C  
5, 12, 18, 24V DC  
G5NB-1A(4)-E  
G5NB-1A-E-HA  
G
5
3A 250V AC (Resistive) 85°C  
100,000  
N
B
Creepage distance  
6.0 mm min.  
6.0 mm min.  
IIIa  
Clearance distance  
Insulation material group  
Pollution degree 2 / Reinforced (Sealed)  
Type of insulation coil-contact circuit  
open contact circuit  
Pollution degree 3 / Basic (Flux protection) / Reinforced (Sealed)  
Micro disconnection  
Rated Insulation voltage  
Pollution degree  
250 V  
3
Rated voltage system  
Over voltage category  
250 V  
III  
Category of protection according to IEC 61810-1
 
RT II (Flux protection) / RT III (Sealed)  
<HA Models only>  
GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)  
Glow wire
 
according to IEC 60335-1  
Tracking resistance
 
according to IEC 60112  
Flammability class according to UL94  
PTI 250 V min. (housing parts)  
V-0  
5

G5NB  
PCB Power Relay  
■
Precautions  
●
Please refer to “PCB Relays Common Precautions” for correct use.  
Correct Use  
●
Coil Voltage Reduction (Holding Voltage) after Relay  
Operation  
●
Power consumption reduction of coil with pulse width  
modulation (PWM)  
• If the coil voltage is reduced to the holding voltage after Relay  
operation, first apply the rated voltage to the coil for at least  
100 ms, as shown below.  
• Models
 
with PWM drive capability (-PW) can reduce coil  
holding current with PWM control. This function reduces power  
consumption by reducing the current held by coil.  
• Apply the rated voltage for at least 100 ms at the time of relay  
operation.  
• A voltage of at least 40% of the rated voltage is required for  
the coil holding voltage. Do not allow voltage fluctuations to  
cause the coil holding voltage to fall below this level.  
• The following are our verification conditions. When using, it be  
sure to check the actual machine under the actual usage  
conditions.  
100%  
(Rated voltage)  
■
Example of drive circuit
 
■
Conditions of validation  
40%  
(Holding voltage)  
carried out by OMRON  
Applied coil voltage (100%)  
• Applied voltage: rated voltage  
100ms min.  
• Duty: 50% or more  
Applied  
Power  
consumption  
• Frequency: 10 kHz or more  
Surge  
Coil resistance*  
Relay  
• Diode Vf: 0.4 V or less  
absorption  
coil voltage  
Coil  
diode  
125
Ω
(5 VDC)  
720
Ω
(12 VDC)  
2880
Ω
(24 VDC)  
Rated voltage  
100%  
40%  
Approx. 200 mW  
Approx. 32 mW  
MOS-FET  
Holding voltage  
Pulse input  
*
The coil resistance were measured at a coil temperature of 23°C with  
tolerances of ± 10%.  
G
5
N
B
Please check each region’s Terms & Conditions by region website.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Regional Contact  
Americas  
Europe  
Asia-Pacific  
China  
Korea  
Japan  
© OMRON Corporation 2007-2021
 
All Rights Reserved.  
In the interest of product improvement, specifications are subject to change without notice.  
Cat. No.
J143-E1-17  
0521(0207)  
6