Omron-Electronics-G5NB-1A4-EL-HA-DC24

Part #Omron-Electronics-G5NB-1A4-EL-HA-DC24
Download 
Omron-Electronics-G5NB-1A4-EL-HA-DC24
G5NB-EL  
A slim compact Relay with 7 A  
switching capacity  
PCB Power Relay  
• 7 A (250 VAC), 5 A (30 VDC) high capacity switching with compact  
size.  
• Minimum 200,000 operations durability at 5 A (250 VAC) switching.  
• IEC/EN 60335-1 conformed.  
• Ambient operating temperature: max. 85°C  
• IEC/EN 60079-15 conformed. (Only for G5NB-1A4-EL-HA Model)  
RoHS Compliant  
■
Model Number Legend  
G5NB-
@
@@
–
@
–
@
–
@
–

—

@
–

—

@  
— —
 
— —  
—
—
1 2
 
3 4  
5
6
7
8
1. Number
 
of Poles  
4. Classification  
EL :
 
High capacity and electrical durability  
7. High
 
temperature rating  
None : Not supported  
A85 :
 
High temperature rating at 85°C  
G
5
1
: 1-pole  
N
B
2. Contact
 
Form  
5. Conformity
 
standard  
HA :
 
IEC/EN 60335-1 conformed  
A
: SPST-NO (1a)  
8. Packing  
None : Tray Packing  
SP :
 
Tube Packing  
E
L
3. Enclosure
 
rating  
6. Coil
 
Holding Voltage  
None : Not supported  
PW :
 
Supported  
4
: Fully sealed  
■
Application Examples  
• Home appliances  
• Building automation  
• Industrial equipment  
■
Ordering Information  
Classification  
Contact form  
Enclosure rating  
Fully Sealed  
Model  
Rated coil voltage  
DC5,12,24V  
Minimum packing unit  
G5NB-1A4-EL-HA(-SP)  
G5NB-1A4-EL-HA-PW(-SP)  
G5NB-1A-EL-HA-A85  
100pcs./Tray  
50pcs./Tube  
SPST-NO  
(1a)  
Single stable relay  
Flux protection  
100pcs./Tray  
Note 1. When ordering, add the rated coil voltage to the model number.  
Example: G5NB-1A4-EL-HA DC12  
Rated coil voltage  
However, the notation of the coil voltage on the product case as well as on the packing will be marked as
@@
VDC.  
Note 2. When ordering tape packing, add “-SP” to the model number.  
Be sure since “-SP” is not part of the relay model number, it is not marked on the relay case.  
1

G5NB-EL  
PCB Power Relay  
■
Ratings  
●
Coil  
Rated current  
Coil resistance  
Must operate voltage
 
Must release voltage  
Max. voltage  
Power consumption  
(mW)  
Rated voltage  
(mA)  
(
Ω
)  
(V)  
(V)  
(V)  
5 VDC  
12 VDC  
24 VDC  
40  
125  
720  
10% min.  
10 to 39%*  
Approx. 200  
Approx. 50*  
16.7  
8.3  
75% max.  
160% (at 23°C)  
2880  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.  
Note 2. The operating characteristics are measured at a coil temperature of 23°C.  
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.  
*
These numbers are only for -PW type. Power consumption with Holding Voltage is approx.50mW. Please confirm the detail in page 4 Coil Voltage Reduction  
(Holding Voltage).  
●
Contacts  
Item  
Load  
Resistive load  
Single  
Contact Type  
Contact material  
Ag-alloy (Cd free)  
5 A at 250 VAC, 7 A at 250 VAC  
5 A at 30 VDC  
Rated load  
Rated carry current  
5 A at DC, 7 A at AC  
250 VAC, 30 VDC  
5 A at DC, 7 A at AC  
Max. switching voltage  
Max. switching current  
■
Characteristics  
G
5
N
B
Contact resistance *1  
Operate time  
100 m
Ω
max.  
10 ms max.  
E
L
Release time  
10 ms max.  
Insulation resistance *2  
1,000 M
Ω
min.  
Between coil and contacts
 
4,000 VAC, 50/60 Hz for 1 min  
Dielectric  
strength  
Between contacts of the  
750 VAC, 50/60 Hz for 1 min  
same polarity  
Insulation  
distance  
Between coil and contacts
 
Clearance: 6 mm, Creepage: 6 mm  
Impulse  
withstand  
voltage  
Between coil and contacts
 
10 kV (1.2 x 50
μ
s)  
Destruction  
Malfunction  
Destruction  
Malfunction  
Mechanical  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
Vibration  
resistance  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
1,000 m/s

2  

100 m/s

2  

Shock  
resistance  
5,000,000 operations min.  
• Standard, Coil holding voltage type  
200,000 operations at 250 VAC, 5 A  
50,000 operations at 250 VAC, 7 A  
100,000 operations at 30 VDC, 5 A  
Durability  
Electrical (resistive load)  
• High temperature rating type (G5NB-1A-EL-HA-A85)  
100,000 operations at 250 VAC, 5 A at 85°C  
50,000 operations at 250 VAC, 7 A at 85°C  
Failure rate (P level) (reference value) *3
 
DC5V 10mA  
Ambient operating temperature  
Ambient operating humidity  
Weight  
-40°C to 85°C (with no icing or condensation)  
5% to 85%  
Approx. 4 g  
Note. The data shown above are initial value.  
*1. Measurement
 
conditions: 5 VDC, 1 A, voltage drop method  
*2. Measurement
 
conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.  
*3. This
 
value was measured at a switching frequency of 120 operations/min.  
2

G5NB-EL  
PCB Power Relay  
■
Engineering Data  
●
Maximum Switching Capacity  
●
Durability  
10  
100  
7
AC resistive  
load  
5
50  
30  
30V DC resistive load  
250V AC resistive load  
DC resistive  
load  
1
10  
5
3
0.1  
1
1
10  
30  
100  
250  
1,000  
0
1
2
3
4
5
6
7
Switching voltage (V)  
Switching current (A)  
●
Ambient Temperature vs. Maximum Coil Voltage  
●
Shock malfunction  
Y
200  
1,000  
Test Item: G5NB-1A4-EL-HA
 
24 VDC  
Number of Relays: 5 pcs.  
Energized  
De-energized  
180  
Test Item: G5NB-1A4-EL-HA 24 VDC  
Number of Relays: 5 pcs  
7
0
0  
7A current  
1,000  
X
1,000  
Z’  
160  
Test Method: Shock is applied 3  
times in 6 directions along 3 axes  
and the level at which shock caused  
malfunction is measured. The  
energized voltage should be 100% of  
the rated voltage.  
G
5
140  
120  
100  
80  
N
B
125  
Rating: 100 m/s

2  

E
L
Z
X’  
1,000  
1,000  
60  
1,000  
Y’  
Unit: m/s

2  

Shock direction  
40  
0
20 23  
40  
60  
80 85  
100  
X
X’  
Y
Ambient temperature (
°
C)  
Z
Z’  
Note:
The maximum coil voltage refers to the max-  
imum value in a varying range of operating  
power voltage, not a continuous voltage.  
Y’  
■
Dimensions  
(Unit: mm)  
G5NB-1A4-EL-HA(-PW)  
G5NB-1A-EL-HA-A85  
PCB Mounting Holes  
(Bottom View)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
7.2max.  
(7.0)*  
20.5max.  
(20.4)*  
(1.05)  
11.5  
7
Fo
u
r, 1.1 dia.  
15.3max.  
(15.0)*  
(1.15)  
1
4
2
3
4.7  
3.4  
@
0.4  
(No coil polarity)  
0.27  
0.33  
0.
8  
11.5  
7
4.7  
*A
v
erage
v
al
u
e  
3

G5NB-EL  
PCB Power Relay  
■
Approved Standards  
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values  
before use.  
●
UL Recognized:  
(File No. E41515)  
(File No. LR31928)  
CSA Certified:  
Number of test  
operations  
Model  
Contact form  
Coil ratings  
Contact ratings  
7A 250V AC (General Purpose) 85°C  
5A 250V AC (General Purpose) 85°C  
5A 30V DC (Resistive) 85°C  
30,000  
50,000  
6,000  
G5NB-1A4-EL-HA(-PW)  
G5NB-1A-EL-HA-A85  
SPST-NO  
(1a)  
5 to 24V DC  
●
EN/IEC, VDE Certified  
(Certificate No. 137575)  
Number of test  
operations  
Model  
Contact form  
Coil ratings  
Contact ratings  
7A 250V AC (Resistive) 85°C  
5A 30V DC (Resistive) 85°C  
G5NB-1A4-EL-HA(-PW)  
G5NB-1A-EL-HA-A85  
SPST-NO  
(1a)  
5, 12, 24V DC  
10,000  
■
Precautions  
●
Please refer to “PCB Relays Common Precautions” for correct use.  
G
5
Correct Use  
N
B
●
Coil Voltage Reduction (Holding Voltage) after Relay  
operation  
• If the coil voltage is reduced to the holding voltage after Relay  
operation, first apply the rated voltage to the coil for at least  
100 ms, as shown below.  
E
L
• A voltage of at least 50% of the rated voltage is required for  
the coil holding voltage. Do not allow voltage fluctuations to  
cause the coil holding voltage to fall below this level.  
100%  
(Rated voltage)  
50%  
(Holding voltage)  
100ms min.  
Applied  
coil voltage  
Power  
consumption  
Coil resistance*  
125
Ω
(5 VDC)  
720
Ω
(12 VDC)  
2880
Ω
(24 VDC)  
Rated voltage  
100%  
50%  
Approx.200 mW  
Approx.50 mW  
Holding voltage  
*
The coil resistance were measured at a coil temperature of 23°C with  
tolerances of ±10%.  
4

G5NB-EL  
PCB Power Relay  
■
Other data  
Creepage distance  
6.0 mm  
Clearance distance  
6.0 mm  
Insulation Material Group  
Type of insulation coil-contact circuit  
open contact circuit  
III a  
Reinforced  
Micro disconnection  
Rated Insulation Voltage  
Pollution degree  
250V  
3
Rated voltage system  
250V  
III  
Overvoltage category  
Category of protection according to IEC 61810-1  
RT III  
<HA Models only>  
GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)  
Glow wire according to IEC 60335-1  
Tracking Index of relay base  
PTI 250V min. (housing Parts)  
V-0  
Flammability class according to UL94  
G
5
N
B
E
L
Please check each region’s Terms & Conditions by region website.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Regional Contact  
Americas  
Europe  
Asia-Pacific  
China  
Korea  
Japan  
© OMRON Corporation 2014-2019
 
All Rights Reserved.  
In the interest of product improvement, specifications are subject to change without notice.  
Cat. No.
K270-E1-05  
0719(0914)(O)  
5