Power Relay  
G5PA-1  
New G5P-series Power Relay is Ideal for  
Power Supplies of TV Sets and Audio  
Systems  
Switches an inrush current of 78 A and a constant  
current of 5 A, thus meeting TV-5 requirements for  
TV and audio system use.  
Highly sensitive with a coil power consumption of  
250 mW.  
Ensures a long service life of 40,000 operations  
when switching an inrush current of 100 A.  
Incorporates environment-friendly contacts without  
cadmium.  
RCSE  
Equipped with a package of double-insulation  
construction ensuring high insulation performance.  
Models conforming to UL508, CSA C22.2,  
VDE0435/IEC255, and SEMKO are available.  
Ordering Information  
Classification  
Contact form  
Enclosure ratings  
Model  
Standard  
SPST-NO  
Flux protection  
G5PA-1-8  
Note:
When ordering, add the rated coil voltage to the model number.  
Example: G5PA-1-8 12 VDC  
Rated coil voltage  
Model Number Legend  
G5PA-1-8
j
VDC  
1
2
3
1. Number
 
of Poles  
3. Rated
 
Coil Voltage  
1:  
1 pole (SPST-NO)  
12, 24 VDC  
2. Coil
 
Terminal Width  
8: 0.8
 
mm  
Specifications  
Coil Ratings  
Rated voltage  
12 VDC  
24 VDC  
Rated current  
20.8 mA  
10.4 mA  
Coil resistance  
576
!
 
2,304
!  
Must operate voltage  
Must release voltage  
Max. permissible voltage  
Power consumption  
80% of rated voltage max.  
10% of rated voltage min.  
110% of rated voltage  
Approx. 250 mW  
Note:
1. Each
 
rated current or coil resistance value must allow a tolerance of
“
10% at a coil temperature of 23
#
C.  
2. The
 
operating characteristics are values at a coil temperature of 23
#
C.  
3. The
 
maximum permissible voltage is the maximum voltage that is applicable to the relay coil for an instant.  
1

G5PA-1  
G5PA-1  
Contact Ratings  
Rated load (capacitive load)  
Resistive load (reference value)  
Max. switching voltage  
125 VAC with inrush current of 100 A (0 to peak) and constant current of 3 A (rms)  
5 A, 250 VAC; 5A, 30 VDC  
250 VAC, 30 VDC  
5 A  
Max. switching current  
Characteristics  
Contact resistance (see note 2)  
100 m
!
max.  
Operate time  
15 ms max.  
Release time  
5 ms max.  
Insulation resistance (see note 3)  
Dielectric strength  
1,000 M
!
min. (at 500 VDC)  
4,000 VAC 50/60 Hz for 1 min between coil and contacts  
1,000 VAC 50/60 Hz for 1 min between contacts of same polarity  
Impulse withstand voltage  
Vibration resistance  
10,000 V (1.2 x 50
$
s) between coil and contacts  
Destruction: 10
 
to 55 Hz, 1.5-mm double amplitude  
Malfunction: 10
 
to 55 Hz, 1.5-mm double amplitude  
2
Shock resistance  
Life expectancy  
Destruction: 1,000
 
m/s  
Malfunction: 200
 
m/s  
2
Mechanical: 1,000,000
 
operations min. (at 18,000 operations an hour)  
Electrical:  
40,000 operations min. with a rated load at a 1,800 operations an hour.  
80,000 operations min. with a resistive load (reference value)  
Ambient temperature  
Ambient humidity  
Weight  
Operating:
–
–
40
#
C to 70
#
C (with no icing)  
Operating: 35% to 85%  
Approx. 10 g  
Note:
1. The
 
data shown above are initial values.  
2. The
 
contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.  
3. The
 
insulation resistance was measured at 500 VDC. There was no difference in measurement position between this item and the  
dielectric strength item.  
Approved Standards  
UL (File No. E41515, UL508)  
CSA (File No. LR31928, C22.2 No. 14)  
TÜV (Certificate No. R9650435, IEC255/VDE0435)  
Model  
Coil ratings  
Contact ratings  
Number of  
test  
Model  
Coil ratings  
Contact  
ratings  
Number of  
test  
operations  
operations  
G5PA-1  
5 to 24 VDC  
5 A, 250 VAC  
(cos
% & ‘(  
5 A, 30 VDC  
(L/R : 0 ms)  
100,000  
G5PA-1  
5 to 24 VDC  
5 A, 277 VAC
 
30,000  
5 A, 30 VDC  
TV-5 rating  
6,000  
25,000  
SEMKO (Certificate No. 9732043; EN60065)  
Model  
Coil ratings  
Contact ratings  
Number of  
test  
operations  
G5PA-1 5
 
to 28 VDC  
5 A/40 A, 250 VAC
 
10,000  
3 A/100 A, 250 VAC  
2

G5PA-1  
G5PA-1  
Engineering Data  
Maximum Switching Power  
Ambient Temperatures vs.  
Maximum Coil Voltage  
150  
G5PA-1  
DC resis-  
tance  
G5PA-1  
AC resis-  
tance  
load  
load  
Ambient temperature (
#
C)  
Switching voltage (V)  
Note:
The maximum coil voltage refers to the maxi-  
mum value in a varying range of operating  
power voltage, not a continuous voltage.  
Dimensions  
Note:
All units are in millimeters unless otherwise indicated.  
10 max.  
(9.85)*  
Mounting Holes  
(Bottom View)  
Terminal Arrangement  
/Internal Connections  
24 max.  
(23.85)*  
(Bottom View)  
T
o
lerance:
“
0.1 mm.  
Two, 1.0-dia. holes  
Two, 1.3-dia. holes  
25 max.  
(24.85)*  
No coil polarity  
*Average value  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To
c
onvert millimeters into inches, multiply by 0.03937.
T
o
c
onvert grams into ounces, multiply by 0.03527.  
Cat. No. J113-E1-2A  
3