Power Relay
G5PA-1
New G5P-series Power Relay is Ideal for
Power Supplies of TV Sets and Audio
Systems
Switches an inrush current of 78 A and a constant
current of 5 A, thus meeting TV-5 requirements for
TV and audio system use.
Highly sensitive with a coil power consumption of
250 mW.
Ensures a long service life of 40,000 operations
when switching an inrush current of 100 A.
Incorporates environment-friendly contacts without
cadmium.
RCSE
Equipped with a package of double-insulation
construction ensuring high insulation performance.
Models conforming to UL508, CSA C22.2,
VDE0435/IEC255, and SEMKO are available.
Ordering Information
Classification
Contact form
Enclosure ratings
Model
Standard
SPST-NO
Flux protection
G5PA-1-8
Note:
When ordering, add the rated coil voltage to the model number.
Example: G5PA-1-8 12 VDC
Rated coil voltage
Model Number Legend
G5PA-1-8
j
VDC
1
2
3
1. Number
of Poles
3. Rated
Coil Voltage
1:
1 pole (SPST-NO)
12, 24 VDC
2. Coil
Terminal Width
8: 0.8
mm
Specifications
Coil Ratings
Rated voltage
12 VDC
24 VDC
Rated current
20.8 mA
10.4 mA
Coil resistance
576
!
2,304
!
Must operate voltage
Must release voltage
Max. permissible voltage
Power consumption
80% of rated voltage max.
10% of rated voltage min.
110% of rated voltage
Approx. 250 mW
Note:
1. Each
rated current or coil resistance value must allow a tolerance of
“
10% at a coil temperature of 23
#
C.
2. The
operating characteristics are values at a coil temperature of 23
#
C.
3. The
maximum permissible voltage is the maximum voltage that is applicable to the relay coil for an instant.
1
G5PA-1
G5PA-1
Contact Ratings
Rated load (capacitive load)
Resistive load (reference value)
Max. switching voltage
125 VAC with inrush current of 100 A (0 to peak) and constant current of 3 A (rms)
5 A, 250 VAC; 5A, 30 VDC
250 VAC, 30 VDC
5 A
Max. switching current
Characteristics
Contact resistance (see note 2)
100 m
!
max.
Operate time
15 ms max.
Release time
5 ms max.
Insulation resistance (see note 3)
Dielectric strength
1,000 M
!
min. (at 500 VDC)
4,000 VAC 50/60 Hz for 1 min between coil and contacts
1,000 VAC 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
Vibration resistance
10,000 V (1.2 x 50
$
s) between coil and contacts
Destruction: 10
to 55 Hz, 1.5-mm double amplitude
Malfunction: 10
to 55 Hz, 1.5-mm double amplitude
2
Shock resistance
Life expectancy
Destruction: 1,000
m/s
Malfunction: 200
m/s
2
Mechanical: 1,000,000
operations min. (at 18,000 operations an hour)
Electrical:
40,000 operations min. with a rated load at a 1,800 operations an hour.
80,000 operations min. with a resistive load (reference value)
Ambient temperature
Ambient humidity
Weight
Operating:
–
–
40
#
C to 70
#
C (with no icing)
Operating: 35% to 85%
Approx. 10 g
Note:
1. The
data shown above are initial values.
2. The
contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
3. The
insulation resistance was measured at 500 VDC. There was no difference in measurement position between this item and the
dielectric strength item.
Approved Standards
UL (File No. E41515, UL508)
CSA (File No. LR31928, C22.2 No. 14)
TÜV (Certificate No. R9650435, IEC255/VDE0435)
Model
Coil ratings
Contact ratings
Number of
test
Model
Coil ratings
Contact
ratings
Number of
test
operations
operations
G5PA-1
5 to 24 VDC
5 A, 250 VAC
(cos
% & ‘(
5 A, 30 VDC
(L/R : 0 ms)
100,000
G5PA-1
5 to 24 VDC
5 A, 277 VAC
30,000
5 A, 30 VDC
TV-5 rating
6,000
25,000
SEMKO (Certificate No. 9732043; EN60065)
Model
Coil ratings
Contact ratings
Number of
test
operations
G5PA-1 5
to 28 VDC
5 A/40 A, 250 VAC
10,000
3 A/100 A, 250 VAC
2
G5PA-1
G5PA-1
Engineering Data
Maximum Switching Power
Ambient Temperatures vs.
Maximum Coil Voltage
150
G5PA-1
DC resis-
tance
G5PA-1
AC resis-
tance
load
load
Ambient temperature (
#
C)
Switching voltage (V)
Note:
The maximum coil voltage refers to the maxi-
mum value in a varying range of operating
power voltage, not a continuous voltage.
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
10 max.
(9.85)*
Mounting Holes
(Bottom View)
Terminal Arrangement
/Internal Connections
24 max.
(23.85)*
(Bottom View)
T
o
lerance:
“
0.1 mm.
Two, 1.0-dia. holes
Two, 1.3-dia. holes
25 max.
(24.85)*
No coil polarity
*Average value
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.