Omron-Electronics-G5PZ-1A-DC12
| Part # | Omron-Electronics-G5PZ-1A-DC12 |
| Download | Omron-Electronics-G5PZ-1A-DC12 |
G5PZ
PCB Power Relay
Compact 20 A Power Relay
• 10.5 mm (W) slim size and 1 pole 16 A/20 A switching capability
• High sensitivity of 530 mW coil consumption and further saving energy
with holding voltage 50%
• Min. 6.4 mm of insulation distance and 10 kV impulse withstand voltage
(between coil and contacts)
• IEC60664-1 Reinforced insulation conformed
RoHS Compliant
■
Model Number Legend
G5PZ-
@
@@
–
@
— — —
—
1 2 3
4
1. Number
of Poles
2. Contact
Form
: 1-pole
: SPST-NO (1a)
3. Enclosure
rating
4. Classification
1
A
None : Flux
protection
None : Standard
G
5
P
Z
E
: High-capacity
■
Application Examples
• Air conditioners
• OA equipments
• Industrial machinery
• Home appliances
■
Ordering Information
Classification
Standard
Contact form
Enclosure rating
Flux protection
Model
Rated coil voltage
Minimum packing unit
100 pcs. / Tray
G5PZ-1A
5 VDC
12 VDC
24 VDC
SPST-NO (1a)
High-capacity
G5PZ-1A-E
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G5PZ-1A DC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as
@@
VDC.
■
Ratings
●
Coil
Item
Rated current (mA)
Coil resistance (
Ω
)
Must-operate voltage (V)
Must-release voltage (V)
% of rated voltage
Max. voltage (V)
Power consumption (mW)
Approx. 530
Rated voltage
5 VDC
106
44.1
22.1
47
140%
(at 23°C)
12 VDC
24 VDC
272
75% max.
10% min.
1087
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
●
Contacts
Classification
Model
Standard
G5PZ-1A
High-capacity
G5PZ-1A-E
Item
Load
Resistive load
Single
Contact type
Contact material
Rated load
Ag-alloy (Cd free)
16 A at 250 VAC
16 A
20 A at 250 VAC
20 A
Rated carry current
Max. switching voltage
Max. switching current
250 VAC
16 A
20 A
1
G5PZ
■
Characteristics
PCB Power Relay
■
Actual Load Life (Reference Values)
1.
250 VAC
Inverter load (Standard)
Inrush: 240 A (0-P, Rise Time 3 ms or more), Current 16 A, Cut
off current 0 A
Classification
Standard
G5PZ-1A
High-capacity
G5PZ-1A-E
Item
Model
Contact resistance *1
Operate time
Release time
100 m
Ω
max.
15 ms max.
5 ms max.
50,000 operations min. (at 23°C)
2.
250 VAC
Inverter load (High-capacity)
Inrush: 240 A (0-P, Rise Time 3 ms or more), Current 20 A,
Cut off current 0 A
Insulation resistance *2
Between coil
1,000 M
Ω
min.
4,000 VAC 50/60 Hz 1 min
and contacts
50,000 operations min. (at 23°C)
Dielectric
Between
strength
contacts of the
same polarity
1,000 VAC 50/60 Hz 1 min
Impulse
Between coil
withstand
and contacts
voltage
10 kV (1.2 x 50
μ
s)
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Destruction
Vibration
resistance
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Malfunction
Destruction
Shock
1,000 m/s
2
resistance
Malfunction
Mechanical
200 m/s
2
2,000,000 operations min.
Durability
Electrical
(resistive load)
100,000 operations
at 250 VAC, 16 A
50,000 operations
at 250 VAC, 20 A
G
5
P
Z
Failure rate (P level)
(reference value) *3
5 VDC 100 mA
-40 to 70°C
Ambient operating
temperature
(with no icing or condensation)
Ambient operating humidity
5 to 85%
Weight
Approx. 10.5 g
Note. Values in the above table are the initial values at 23°C.
*1. Measurement
conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement
conditions: Measured at the same points as the dielectric
strength using a 500 VDC ohmmeter.
*3. This
value was measured at a switching frequency of 120 operations/min.
2
G5PZ
■
Engineering Data
PCB Power Relay
●
Ambient Temperature vs. Maximum
Coil Voltage
●
Maximum Switching Capacity
160
Standard models
Test item: G5PZ-1A, 12 VDC
High-capacity models
25
Number of Relays: 5 pcs
140
120
100
80
60
40
20
0
5
1
1
10
100
1000
0
40
60
80
100
20 23
Switching voltage (V)
Ambient temperature (°C)
Note. The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
●
Shock malfunction
Y
G
5
P
Z
1,000
Energized
1,000
Test Item:
Number of Relays: 5 pcs
G5PZ-1A 12 VDC
Test Method:
Rating:
Shock is applied 3 times in 6 directions
along 3 axes and the level at which shock
caused malfunction is measured.
The energized voltage is 100% of the
rated voltage.
X
1,000
Z’
1,000
De-energized
200 m/s
2
1,000
X’
Z
1,000
1,000
Y’
Unit: m/s
2
Shock direction
X
X’
Y
Z
Z’
Y’
Please visit our website, which is noted on the last page.
CAD Data
■
Dimensions
(Unit: mm)
G5PZ
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(Bottom View)
10.5max.
(10.3)*
24max.
(23.8)*
16.5
1
4
2
3
7.5
25max.
(24.9)*
Two, 1.3 dia.
Two, 1 dia.
(No coil polarity)
20
0.5
0.4×0.4
0.4
4
1
1
0.4
CAD Data
*Average value
3
G5PZ
■
Approved Standards
PCB Power Relay
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values
before use.
●
UL Recognized:
CSA Certified:
(File No. E41515)
(File No. LR31928)
Model
G5PZ-1A
Contact form
Coil ratings
5 to 24 VDC
Contact ratings
16 A, 277 VAC (Resistive) 70°C
20 A, 277 VAC (Resistive) 70°C
Number of test operations
6,000
SPST-NO(1a)
G5PZ-1A-E
50,000
●
EN/IEC, VDE Certified:
(Certificate No. 40042966)
Model
Contact form
SPST-NO(1a)
Coil ratings
Contact ratings
Number of test operations
6,000
G5PZ-1A
5, 12, 24 VDC
16 A, 250 V AC (Resistive) 70°C
●
EN/IEC, TÜV Certified:
(Certificate No. R50408241)
Model
Contact form
SPST-NO(1a)
Coil ratings
Contact ratings
Number of test operations
50,000
G5PZ-1A-E
5, 12, 24 VDC
20 A, 250 VAC (cos
φ
=1) 70°C
●
CQC Certified:
(Certificate No. CQC15002133270)
Model
G5PZ-1A
Contact form
Coil ratings
Contact ratings
16 A, 250 VAC (cos
φ
=1) 70°C
20 A, 250 VAC (cos
φ
=1) 70°C
Number of test operations
6,000
SPST-NO(1a)
5, 12, 24 VDC
G5PZ-1A-E
50,000
G
5
P
Z
Creepage distance
9.5 mm min.
Clearance distance
Insulation material group
6.4 mm min.
III a
Type of insulation coil-contact circuit
open contact circuit
Reinforced (Standerd : Pollution degree 2)
(High-capacity : Pollution degree 3)
Type of disconnection open contact circuit
Rated Insulation voltage
Pollution degree
Micro disconnection
250 VAC
2
Rated voltage system
250 V
III
Over voltage category
Category of protection according to IEC 61810-1
RT II
Tracking resistance according to IEC 60112
Flammability class according to UL94
PTI 250 V min. (housing parts)
V-0
4
G5PZ
■
Precautions
PCB Power Relay
●
Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●
Coil Voltage Reduction (Holding Voltage) after Relay
Operation
• If the coil voltage is reduced to the holding voltage after Relay
operation, first apply the rated voltage to the coil for at least
100 ms, as shown below.
• A voltage of at least 50% of the rated voltage is required for
the coil holding voltage. Do not allow voltage fluctuations to
cause the coil holding voltage to fall below this level.
100%
(Rated voltage)
50%
(Holding voltage)
Applied
coil voltage
Power
consumption
Coil resistance*
475
Ω
(5 VDC)
272
Ω
(12 VDC)
1087
Ω
(24 VDC)
Rated voltage
100%
50%
Approx. 530 mW
Approx. 133 mW
Holding voltage
*
The coil resistance were measured at a coil temperature of 23°C with
tolerances of ± 10%.
G
5
P
Z
Please check each region’s Terms & Conditions by region website.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
Europe
Asia-Pacific
China
Korea
Japan
© OMRON Corporation 2007-2020
All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. J143-E1-15
0120(0207)(O)
5