Omron-Electronics-G5Q-1A4-EU-DC5

Part #Omron-Electronics-G5Q-1A4-EU-DC5
Download 
Omron-Electronics-G5Q-1A4-EU-DC5
G5Q  
A Miniature Power Relay with  
1-pole 10A Switching Capacity  
PCB Power Relay  
• Excellent switching performance for a variety of loads.  
• Small, yet provides 8-kV impulse withstand voltage (between coil  
and contacts).  
• Low coil power consumption (SPST-NO: 200 mW, SPDT: 400 mW)  
• Coil insulation system: Class F (UL1446).  
• IEC/EN 60335-1 conformed. (-HA Model)  
• Reduced power consumption with voltage holding and pulse width  
modulation (PWM) control (Only for G5Q-
@
-PW model)  
RoHS Compliant  
■
Model Number Legend  
■
Application Examples  
• Ideal for output applications of control equipment.  
G5Q-
@
@@
–
@
–
@
–
@  
— — —  
—
—
—
1 2 3  
4
5
6
G
5
1. Number
 
of Poles  
4. Classification  
None : Standard  
EU :
 
High-capacity  
1
: 1-pole  
2. Contact
 
Form  
None : SPDT (1c)  
Q
5. Market Code  
A
: SPST-NO (1a)
 
None : General purpose  
HA :
 
Home Appliance according to  
IEC/EN60335-1  
6. Special Requirement  
None : Not supported  
PW :
 
Supported  
3. Enclosure
 
Rating  
None : Flux protection  
4
: Sealed  
1

G5Q  
PCB Power Relay  
■
Ordering Information  
Terminal Shape  
Market Code  
Classification  
Contact Form  
SPST-NO(1a)  
Enclosure Rating  
Flux protection  
Model  
G5Q-1A  
Rated Coil Voltage
 
Minimum Packing Unit  
5VDC  
9VDC  
12VDC  
24VDC  
5VDC  
G5Q-1A-PW  
G5Q-1A4  
12VDC  
24VDC  
5VDC  
9VDC  
Sealed  
Flux protection  
Sealed  
12VDC  
24VDC  
5VDC  
Standard  
9VDC  
G5Q-1  
General purpose  
12VDC  
24VDC  
5VDC  
SPDT(1c)  
G5Q-1-PW  
G5Q-14  
12VDC  
24VDC  
5VDC  
9VDC  
12VDC  
24VDC  
PCB terminals  
100 pcs/tray  
Flux protection  
Sealed  
Flux protection  
Sealed  
G5Q-1A-EU  
G5Q-1A4-EU  
G5Q-1-EU  
SPST-NO(1a)  
SPDT(1c)  
5VDC  
12VDC  
24VDC  
High-capacity  
Standard  
G5Q-14-EU  
G5Q-1A-HA  
5VDC  
12VDC  
24VDC  
G
5
G5Q-1A-HA-PW  
SPST-NO(1a)  
SPDT(1c)  
Q
12VDC  
24VDC  
5VDC  
12VDC  
24VDC  
12VDC  
24VDC  
High-capacity  
Standard  
G5Q-1A-EU-HA  
Home Appliance  
Flux protection  
G5Q-1-HA  
G5Q-1-HA-PW  
High-capacity  
G5Q-1-EU-HA  
Note 1. When ordering, add the rated coil voltage to the model number.  
Example: G5Q-1A DC5  
Rated coil voltage  
Note 2. Contact your OMRON sales representative for tube packing models (40 pcs/tube).  
■
Ratings  
●
Coil  
Must operate  
voltage  
(V)  
Must release  
Power  
consumption  
(mW)  
Rated current  
(mA)  
Coil resistance  
Max. voltage  
Contact form  
Rated voltage  
voltage  
(V)  
(
Ω
)  
(V)  
5 VDC  
9 VDC  
12 VDC  
24 VDC  
5 VDC  
40  
125  
405  
720  
2880  
63  
22.2  
16.7  
8.3  
5% min.  
5 to 34%*  
Approx. 200  
Approx. 32*  
SPST-NO (1a)  
190%  
(at 23°C)  
75% max.  
80  
9 VDC  
12 VDC  
24 VDC  
44.4  
33.3  
16.7  
202  
360  
1440  
5% min.  
5 to 25%*  
Approx. 400  
Approx. 36*  
SPDT (1c)  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.  
Note 2. The operating characteristics are measured at a coil temperature of 23°C.  
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.  
*
Power consumption with holding voltage are Approx. 32 mW for 1a and Approx. 36 mW for 1c. Please confirm the detail on page 6 Coil Voltage Reduction (holding voltage).  
●
Contacts  
Load  
Resistive load  
SPST-NO (1a)  
High-capacity  
Item  
SPDT (1c)  
Standard  
Standard  
High-capacity  
Contact type  
Single  
Contact material  
Ag-Alloy (Cd free)  
10 A at 125 VAC (NO)  
3 A at 125 VAC (NO)  
5 A at 250 VAC (NO)  
3 A at 250 VAC (NO)  
5 A at 30 VDC (NO)  
3 A at 125 VAC (NC)  
3 A at 250 VAC (NC)  
3 A at 30 VDC (NC)  
10 A at 250 VAC (NO)  
3 A at 125 VAC (NO)  
5 A at 250 VAC (NO)  
3 A at 250 VAC (NO)  
5 A at 30 VDC (NO)  
3 A at 125 VAC (NC)  
3 A at 250 VAC (NC)  
3 A at 30 VDC (NC)  
10 A at 125 VAC  
3 A at 125 VAC  
5 A at 250 VAC  
3 A at 250 VAC  
5 A at 30 VDC  
10 A at 250 VAC  
3 A at 125 VAC  
5 A at 250 VAC  
3 A at 250 VAC  
5 A at 30 VDC  
Rated load  
(resistive)  
Rated carry current  
10 A (NO)/3 A (NC)  
Max. switching voltage
 
277 VAC, 30 VDC  
AC: 10 A (NO)/3 A (NC)  
DC: 5 A (NO)/3 A (NC)  
Max. switching current  
2

G5Q  
PCB Power Relay  
■
Characteristics  
Item  
Classification  
Standard model  
Contact resistance *1  
Operate time  
100 m
Ω
max.  
10 ms max.  
5 ms max.  
Release time  
Insulation resistance *2  
1,000 M
Ω
min.  
Between coil and contacts
 
4,000 VAC, 50/60 Hz for 1 min  
Dielectric  
strength  
Between contacts of the  
1,000 VAC, 50/60 Hz for 1 min  
same polarity  
Impulse withstand voltage  
(between coil and contacts)  
8 kV (1.2 x 50
μ
s)  
Destruction  
Malfunction  
Destruction  
Malfunction  
Mechanical  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
Vibration  
resistance  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
1,000 m/s

2  

100 m/s

2  

Shock  
resistance  
10,000,000 operations (18,000 operations per hour)  
•
NO  
25,000 operations: 10 A at 250 VAC resistive load  
(operation: ON for 1 sec, OFF for 3 sec)
 
<High-capacity type>  
50,000 operations: 10 A at 125 VAC resistive load  
(operation: ON for 1 sec, OFF for 3 sec)  
200,000 operations: 3 A at 125 VAC resistive load  
(operation: ON for 1 sec, OFF for 1 sec)  
50,000 operations: 5 A at 250 VAC resistive load  
(operation: ON for 1 sec, OFF for 1 sec)  
100,000 operations: 3 A at 250 VAC resistive load  
(operation: ON for 1 sec, OFF for 1 sec)  
100,000 operations: 5 A at 30 VDC resistive load  
(operation: ON for 1 sec, OFF for 1 sec)  
NC  
G
5
Durability  
Q
Electrical  
•
200,000 operations: 3 A at 125 VAC resistive load  
(operation: ON for 1 sec, OFF for 1 sec)  
100,000 operations: 3 A at 250 VAC resistive load  
(operation: ON for 1 sec, OFF for 1 sec)  
100,000 operations: 3 A at 30 VDC resistive load  
(operation: ON for 1 sec, OFF for 1 sec)  
Failure rate (P level) (reference *3)  
Ambient operating temperature  
10 mA at 5 VDC  
-40°C to 105°C (with no icing or condensation)  
-40°C to 85°C (with no icing or condensation)
 
<High-capacity type>  
Ambient operating humidity  
Weight  
5% to 85%  
Approx. 6.5 g  
Note. Note. Values in the above table are the initial values at 23°C.  
*1. The
 
contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.  
*2. Testing
 
conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.  
*3. This
 
value was measured at a switching frequency of 120 operations/min.  
3

G5Q  
PCB Power Relay  
■
Engineering Data  
●
Maximum Switching Capacity  
●
Ambient Temperature VS.  
●
Shock Malfunction  
Maximum Coil Voltage  
Y
Standard  
Standard  
1,000  
100  
200  
180  
160  
140  
120  
100  
80  
X
Z
1,000  
1,000  
AC resistive load (NO)  
NC  
Contact  
NO Contact  
300  
10  
300  
DC resistive load (NO)  
1,000  
X’  
1,000  
Z’  
AC resistive load (NC)  
60  
40  
1,000  
Y’  
Unit: m/s

2  

DC resistive load (NC)  
10  
20  
Sample: G5Q-14 12 VDC  
Number of Relays: 5 pcs  
Shock direction  
X
X’  
1
0
Y
1
100  
1000  
-40 -20  
0
20 23
 
40  
60  
80  
100  
105  
Ambient temperature (°C)  
120  
Test conditions: Shock is applied  
in ±X, ±Y, and ±Z directions three  
times each with and without  
energizing the Relays to check  
the number of malfunctions.  
The energized voltage is 100% of  
the rated voltage.  
Z
Switching voltgate (V)  
Z’  
Y’  
High-capacity(-EU)  
High-capacity(-EU)  
100  
200  
180  
Requirement: None malfuction  
100 m/s

2  

160  
140  
120  
100  
80  
G
5
Q
AC resistive load (NO)  
AC resistive load (NC)  
10  
DC resistive load (NO)  
60  
40  
DC resistive load (NC)  
10  
20  
1
0
1
100  
1000  
-40 -20  
0
20 23
 
40  
60  
80  
85  
Ambient temperature (°C)  
100  
120  
Switching voltgate (V)  
Note. The Maximum coil voltage refers to the  
maximum value in a varying range of operating  
power voltage, not a continuous voltage.  
■
Dimensions  
(Unit: mm)  
G5Q-1A(4)(-EU)(-HA)(-PW)  
PCB Mounting Holes  
(Bottom View)  
T
o
lerance: 0.1
 
mm  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
10.3MAX  
(10.0)*  
20.3MAX  
(20.0)*  
(1.18
)  
(1.19
)  
7.62 0.1  
1
5
2
3
15.8MAX  
(15.5
)*  
7.62 0.1  
(No coil polarity)  
0.4  
3.4  
0.27  
MAX  
10.16 0.1  
1
0.4 x 0.4  
7.62  
* Average value  
10.16  
7.62  
G5Q-1(4)(-EU)(-HA)(-PW)  
PCB Mounting Holes  
(Bottom View)  
T
o
lerance: 0.1
 
mm  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
10.3MAX  
(10.0)*  
20.3MAX  
(20.0)*  
(1.18
)  
(1.19
)  
1
5
2
3
15.8MAX  
(15.5
)*  
7.62 0.1  
4
(No coil polarity)  
2.54 0.1  
5.08 0.1  
0.4  
3.4  
0.27  
MAX  
1
0.4 x 0.4  
7.62  
10.16 0.1  
2.54  
* Average value  
10.16 5.08  
4

G5Q  
PCB Power Relay  
■
Approved Standards  
UL Recognized:  
CSA Certified:  
(File No. E41515)  
(File No. LR31928)  
Number of test  
operations  
Model  
Contact form  
Coil ratings  
Contact ratings  
10 A 250 VAC N.O. only (Resistive) 40°C  
10 A 30 VDC N.O. only (Resistive) 40°C  
6,000  
100,000  
6,000  
G5Q-1A(4)(-EU)(-HA)(-PW)  
G5Q-1(4)(-EU)(-HA)(-PW)  
SPST-NO (1a)  
SPDT (1c)  
5 to 48 VDC
 
4 A 120 VAC N.O. only (Resistive) 40°C  
3 A 250 VAC N.C. only (Resistive) 40°C  
3 A 30 VDC N.C. only (Resistive) 40°C  
EN/IEC, VDE  
(Certified/No.40009467)  
Number of test  
operations  
Model  
Contact form  
Coil ratings  
Contact ratings  
10 A making and 0 A breaking, 250 VAC (cos
φ
=1) 105°C  
10,000  
75,000  
G5Q-1(4)(-HA)(-PW)  
G5Q-1A(4)(-HA)(-PW)  
5 A marking and 3 A breaking, 30 VDC (0 ms) 105°C  
5 A 250 VAC (cos
φ
=1) (N.O.) 105°C  
SPST-NO (1a)  
SPDT (1c)  
5 to 48 VDC  
10 A 250 VAC (cos
φ
=1) (N.O.) 65°C  
5 A 30 VDC (0 ms) (N.O.) 65°C  
3 A 30 VDC (0 ms) (N.C.) 65°C  
10,000  
G5Q-1A(4)-EU(-HA)  
G5Q-1(4)-EU(-HA)  
4 A 250 VAC (cos
φ
=1) (N.O.)
 
85°C  
100,000  
G
5
Creepage Distance  
6.4 mm min.  
5.5 mm min.  
IIIa  
Clearance Distance  
Insulation Material Group  
Q
Type of Insulation Coil-contact Circuit  
Open Contact Circuit  
Basic (Rated voltage 400 V) / Reinforced (Rated voltage 250 V)  
Micro disconnection  
Rated Insulation Voltage  
Pollution Degree  
250 V  
2
Rated Voltage System  
Over Voltage Category  
250 V / 400 V (EU flux type only)  
III  
Category of Protection according to IEC 61810-1
 
RT II (Flux protection) / RT III (Sealed)  
<HA Models only>  
GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)  
Glow Wire according to IEC 60335-1  
Tracking Index of Relay Base  
Flammability Class according to UL94  
Coil Insulation System  
PTI 250 V min. (housing parts)  
V-0  
F Class (UL 1446)  
5

G5Q  
PCB Power Relay  
■
Precautions  
●
Please refer to “PCB Relays Common Precautions” for correct use.  
Correct Use  
●
Coil Voltage Reduction (Holding Voltage) after Relay  
operation  
• If the coil voltage is reduced to the holding voltage after relay  
●
Power consumption reduction of coil with pulse width  
modulation (PWM)  
• Models with PWM drive capability (-PW) can reduce coil hold-  
operation, first apply the rated voltage to the coil for at least  
100 ms, as shown below.  
• A voltage of at least 40% (G5Q-1A type) /30% (G5Q-1 type) of  
the rated voltage is required for the coil holding voltage.  
Do not allow voltage fluctuations to cause the coil holding volt-  
age to fall below this level.  
ing current with PWM control. This function reduces power  
consumption by reducing the current held by coil.  
• Apply the rated voltage for at least 100 ms at the time of relay  
operation.  
• The following are our verification conditions. When using, it be  
sure to check the actual machine under the actual usage con-  
ditions.  
G5Q-1A  
100%  
■
Example of drive circuit  
■
Conditions of validation  
carried out by OMRON  
(Rated voltage)  
40%  
(Holding voltage)  
Applied coil voltage (100%)  
• Applied
 
voltage: rated volt-  
age  
• Duty: 50% or more  
• Frequency: 10 kHz or more  
• Diode Vf: 0.4 V or less  
100ms min.  
Surge  
Relay  
Coil  
absorption  
diode  
G5Q-1  
100%  
G
5
MOS-FET  
(Rated voltage)  
Pulse input  
Q
30%  
(Holding voltage)  
100ms min.  
G5Q-1A  
Applied  
coil voltage  
Power  
consumption  
Coil resistance*  
125
Ω
(5 VDC)  
720
Ω
(12 VDC)  
2,880
Ω
(24 VDC)  
Rated voltage  
100%  
40%  
Approx. 200 mW  
Approx. 32 mW  
Holding voltage  
*
The coil resistance were measured at a coil temperature of 23°C with toler-  
ances of ±10%.  
G5Q-1  
Applied  
coil voltage  
Power  
consumption  
Coil resistance*  
63
Ω
(5 VDC)  
360
Ω
(12 VDC)  
1,440
Ω
(24 VDC)  
Rated voltage  
Holding voltage  
100%  
30%  
Approx. 400 mW  
Approx. 36 mW  
*
The coil resistance were measured at a coil temperature of 23°C with toler-  
ances of ±10%.  
Please check each region’s Terms & Conditions by region website.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Regional Contact  
Americas  
Europe  
Asia-Pacific  
China  
Korea  
Japan  
© OMRON Corporation 2007-2021
 
All Rights Reserved.  
In the interest of product improvement, specifications are subject to change without notice.  
Cat. No.
J155-E1-16  
0621(0207)  
6