Omron-Electronics-G5RL-K1-E-DC12
| Part # | Omron-Electronics-G5RL-K1-E-DC12 |
| Download | Omron-Electronics-G5RL-K1-E-DC12 |
G5RL-U/-K
PCB Power Relay
Small-Size and Low-Back High
Performance Latching Relay that
Realizes a 16-A High Inrush
Switching Current
• Creepage distance 8 mm between coil and contacts
• 10 kV impulse withstand voltage
• Ambient operating temperature 85°C
• Suitable for TV-8 rating (G5RL-
@
1A-E)
• In-rush resistant and supports illumination load
• Compatible with capacitor load (IEC60669-1) (G5RL-
@
1A-EL-HA)
• Compatible with the International Safety Standard for Electrical/
Electronic Household Appliances (IEC60335-1) (G5RL-
@
1A-EL-HA)
Note. The actual product is marked differently
form the image shown above.
G
5
■
Model Number Legend
G5RL-
@
@@
–
@
–
@
■
Application Examples
R
L
• Housing equipment
• Building automation
• UPS, FA equipment
• Electric power meter
• Illumination control
• Smart home
1 2 3
4
5
U
/
K
1. Relay
Function
3. Contact
Form
None: SPDT (1c)
A : SPS
T
–
NO (1a)
5
. Market
Code
None: General purpose
HA: Home Appliance
according to
U : Single-winding latching
K : Double-winding
latching
2. Number
of poles
4. Classification
E : High-capacity
EL: In-rush
resistance
(Compatible with
IEC60669-1)
IEC/EN60335-1
1 : 1-Pole
■
Ordering Information
Single-winding latching
Double-winding latching
Minimum
Classification
T
e
rminal
shape
Contact form
Enclosure rating
Flux protection
Rated coil
Rated coil
packing unit
Model
Model
voltage
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
5 VDC
12 VDC
24 VDC
voltage
SPS
T
–
NO (1a)
SPDT (1c)
G5RL-U1A-E
G5RL-K1A-E
High-capacity
PCB terminals
5 VDC
12 VDC
24 VDC
G5RL-U1-E
G5RL-K1-E
100 pcs/tray
In-rush
resistance
SPS
T
–
NO (1a)
G5RL-U1A-EL-HA
G5RL-K1A-EL-HA
Note. When ordering, add the rated coil voltage to the model number.
Example: G5RL-U1A-E DC5
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as
@@
VDC.
1
G5RL-U/-K
PCB Power Relay
■
Ratings
●
Coil
Single-Winding Latching Type
Must set
voltage
Must reset
voltage
Power
consumption
(W)
Max voltage
130%
Rated current
Coil resistance
Rated voltage
(mA)
(
Ω
)
% of rated voltage
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
200
120
100
50
15
41.7
60
70% max.
70% max.
Approx. 0.6
240
960
25
Double-Winding Latching Type
Rated current
Must set
voltage
Must reset
voltage
Power consumption
(W)
Coil resistance (
Ω
)
Set coil
Reset coil
Max voltage
(mA)
Rated voltage
Set coil
Reset coil
% of rated voltage
Set coil
Reset coil
5 VDC
150
62.5
35
33.3
192
686
Approx. 0.75
12 VDC
24 VDC
70% max.
70% max.
130%
Approx. 0.84
Note. The rated current and resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
●
Contacts
G
5
Load
Resistive load
Classification
Contact form
Contact type
Contact material
High-capacity
In-rush resistance
SPST-NO (1a)
R
L
SPST-NO (1a)
SPDT (1c)
Single
Ag Alloy (Cd free)
16 A at 250 VAC (NO)
5 A at 250 VAC (NC)
16 A at 24 VDC (NO)
5 A at 24 VDC (NC)
U
/
K
16 A at 250 VAC
16 A at 24 VDC
Rated load
16 A at 250 VAC
Rated carry current
Max. switching voltage
Max. switching current
16 A
16 A
16 A (NO), 5A (NC)
16 A
250 VAC
16 A
250 VAC, 24 VDC
High-capacity
16 A (NO), 5 A (NC)
■
Characteristics
Classification
Relay function
Contact form
In-rush resistance
Single-winding latching, Double-winding latching
SPST-NO (1a), SPDT (1c)
SPST-NO (1a)
Item
Contact resistance *1
Set time
Reset time
Minimum pulse width *2
Maximum pulse width *2
Insulation resistance *3
100 m
Ω
max.
10 ms max.
10 ms max.
30 ms
1 min
1,000 M
Ω
min.
Between coil and contacts
Between contacts of the
same polarity
6,000 VAC, 50/60 Hz for 1 min
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min
1,250 VAC, 50/60 Hz for 1 min
Impulse withstand
voltage
Between coil and contacts
10 kV (1.2
×
50
μ
s)
Insulation distance
Between coil and contacts
Destruction
Clearance: 6.4 mm, Creepage: 8 mm
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Vibration resistance
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) at set status
Malfunction
Destruction
Malfunction
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) at reset status (Except SPST-NO)
2
1,000 m/s
2
Shock resistance
Durability
150 m/s
at Set status
50 m/s
at Reset status (Except SPST-NO)
2
Mechanical *4
Electrical *4
5,000,000 operations min.
50,000 operations min.
-40° to 85°C (with no icing or condensation)
5% to 85%
20,000 operations min.
Ambient operating temperature
Ambient operating humidity
Weight
Approx. 10 g
Note. Values in the above table are initial values.
*1. The
contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method.
*2. These
are measured at a coil temperature of 23°C and rated coil voltage.
Pulse duty factor should be 10% MAX.
*3. The
insulation resistance is measured between coil and contacts and between contacts of same polarity at 500 VDC.
*4. Operated
with input pulse width “30 ms”.
2
G5RL-U/-K
PCB Power Relay
■
Engineering Data
●
In-Rush Resistant Performance (IEC60669-1 Certified Switching Frequency)
G5RL-U1A-EL-HA
Contact form
Operation coil rating
5, 12, 24 VDC
Contact ratings
Number of test cycles
20,000
IEC60669-1
SPST-NO (1a)
16A 250VAC Capacitor 140
μ
F room temperature
G5RL-K1A-EL-HA
Contact form
Operation coil rating
5, 12, 24 VDC
Contact ratings
Number of test cycles
20,000
IEC60669-1
SPST-NO (1a)
16A 250VAC Capacitor 140
μ
F room temperature
●
Maximum Switching Power
High-Capacity
In-Rush Resistance
50
50
AC resistive Load (N.C.)
AC resistive Load
16
10
16
10
5
5
DC resistive Load (N.C.)
1
1
G
5
R
L
0.5
0.5
0.1
0.1
U
/
K
1
10
24
100
250
1000
1
10
100
250
1000
Switching voltage (V)
Switching voltage (V)
●
Ambient Temperature vs.
Maximum Coil Voltage
●
Malfunction Shock
140
130
120
Y
1,000
NO
800
600
400
200
X’
Z
100
80
200
400
600
800
60
Z’
X
40
20
0
Shock direction
X’
Unit: m/s
2
1,000
X
Y’
Y
Z
−40
−20
0
20
40
60
80 85 100
Z’
Ambient
T
e
mperature (˚C)
Y’
Sample:
G5RL-K1A-E 12VDC
Note. Maximum voltage of set pulse and reset
pulse at duty factor 10% (Maximum pulse
width: 1min).
No. of relays:
5 pcs
Test conditions: Shock is applied in ±X, ±Y, and ±Z
directions three times each with set
and reset status to check the
number of contact malfunctions.
2
Standard value:50 m/s
with set status
2
100 m/s
with reset status
3
G5RL-U/-K
■
Dimensions
PCB Power Relay
(Unit: mm)
G5RL-U1A-E
PCB Mounting Holes
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
(BOTTOM VIEW)
* Average value
5
0.1
29.0max.
(28.8)*
12.7max.
(12.5)*
Six, 1.3
0.1 dia.
1
+
3
4
–
S
–
8
R
+
7.5 0.1
15.7max.
(15.5)*
6
5
(2.3)
20 0.1
Note. Check carefully the coil
polarity of the relay.
3.5
0.43
1
@
0.5
5
7.5
Note.
Orientation marks are indicated as follows:
0.33
20
G5RL-U1-E
PCB Mounting Holes
Terminal Arrangement/
(BOTTOM VIEW)
Internal Connections
* Average value
(BOTTOM VIEW)
29.0max.
(28.8)*
12.7max.
(12.5)*
5
0.1 5 0.1
Eight, 1.3
0.1 dia.
G
5
R
L
1
+
S
–
8
2
3
4
5
–
R
+
15.7max.
(15.5)*
7.5 0.1
7
6
U
/
K
(2.3)
20 0.1
3.5
Note. Check carefully the coil
polarity of the relay.
0.43
0.43
20
1
@
0.5
5
5
7.5
0.33
Note.
Orientation marks are indicated as follows:
G5RL-K1A-E
PCB Mounting Holes
Terminal Arrangement/
(BOTTOM VIEW)
Internal Connections
* Average value
(BOTTOM VIEW)
5
0.1
29.0max.
(28.8)*
12.7max.
(12.5)*
Seven, 1.3
0.1 dia.
(3.75)
–
1
9
8
3
4
5
R
+
S
–
7.5 0.1
15.7max.
(15.5)*
6
3.75 0.1
(2.3)
20 0.1
Note. Check carefully the coil
polarity of the relay.
3.5
0.43
1
@
0.5
0.8
5
Note.
Orientation marks are indicated as follows:
3.75
3.75
0.33
7.5
20
G5RL-K1-E
PCB Mounting Holes
Terminal Arrangement/
(BOTTOM VIEW)
Internal Connections
* Average value
(BOTTOM VIEW)
5
0.15 0.1
29.0max.
(28.8)*
12.7max.
(12.5)*
Nine, 1.3
0.1 dia.
(3.75)
–
1
9
8
2
3
4
5
R
+
S
–
7.5 0.1
15.7max.
(15.5)*
7
6
3.75 0.1
(2.3)
20 0.1
Note. Check carefully the coil
polarity of the relay.
3.5
0.43
0.43
20
1
@
0.5
0.8
5
5
Note.
Orientation marks are indicated as follows:
3.75
3.75
0.33
7.5
4
G5RL-U/-K
PCB Power Relay
G5RL-U1A-EL-HA
PCB Mounting Holes
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
(BOTTOM VIEW)
* Average value
5
0.1
29.0max.
(28.8)*
12.7max.
(12.5)*
Six, 1.3
0.1 dia.
1
+
3
4
1A-EL-HA
–
G5RL-U
5 V DC
S
–
8
R
+
7.5 0.1
15.7max.
(15.5)*
6
5
(2.3)
20 0.1
Note. Check carefully the coil
polarity of the relay.
3.5
0.43
1
@
0.5
5
7.5
Note.
Orientation marks are indicated as follows:
0.33
20
G5RL-K1A-EL-HA
PCB Mounting Holes
Terminal Arrangement/
(BOTTOM VIEW)
Internal Connections
* Average value
(BOTTOM VIEW)
5
0.1
29.0max.
(28.8)*
12.7max.
(12.5)*
Seven, 1.3
0.1 dia.
(3.75)
–
1
9
8
3
4
5
G5RL-K1A-EL-HA
5 V DC
R
+
S
–
G
5
R
L
7.5 0.1
15.7max.
(15.5)*
6
3.75 0.1
(2.3)
20 0.1
Note. Check carefully the coil
polarity of the relay.
3.5
U
/
K
0.43
1
@
0.5
0.8
5
Note.
Orientation marks are indicated as follows:
3.75
3.75
0.33
7.5
20
5
G5RL-U/-K
PCB Power Relay
■
Approved Standards
●
UL Recognized (File No. E41643) and
CSA Certified (File No. LR31928)
Number of
test cycles
Model
Contact form
Coil ratings
Contact ratings
16 A 277 VAC (Resistive) – NO 85°C
TV-5 – NO 40°C
50,000
25,000
25,000
6,000
G5RL-U1A-E
G5RL-K1A-E
Single-winding latching: 3, 5, 6, 12, 24 VDC
Double-winding latching: 5, 12, 24 VDC
SPST-NO (1a)
TV-8 – NO 40°C
8 A 250 VAC (Ballast) – NO 40°C
2,000 W 250 VAC (Tungsten) 70°C
16 A 277 VAC (Resistive) – NO 85°C
8 A 250 VAC (Ballast) – NO 40°C
2,000 W 250 VAC (Tungsten) – NO 40°C
5 A 250 VAC (General) – NC 40°C
6,000
50,000
6,000
G5RL-U1-E
G5RL-K1-E
Single-winding latching: 3, 5, 6, 12, 24 VDC
Double-winding latching: 5, 12, 24 VDC
SPDT (1c)
6,000
50,000
●
UL/C-UL-approved models (File No. E41643)
Number of
test cycles
Model
Contact form
Coil ratings
Contact ratings
G5RL-U1A-EL-HA
G5RL-K1A-EL-HA
Single-winding latching: 5, 12, 24 VDC
Double-winding latching: 5, 12, 24 VDC
SPST-NO (1a)
16 A 250 VAC (General) 85°C
6,000
●
VDE Certified (EN61810-1) (License No. 40007172)
G
5
Number of
test cycles
Model
Contact form
Coil ratings
Contact ratings
R
L
16 A 250 VAC (cos
φ
=1) – NO 85°C
30,000
G5RL-U1A-E
G5RL-K1A-E
Single-winding latching: 3, 5, 6, 12, 24 VDC
Double-winding latching: 5, 12, 24 VDC
SPST-NO (1a)
U
/
K
240 VAC 100 A (0-P) Steady 10 A (rms) – NO 85°C
16 A 250 VAC (cos
φ
=1) – NO 85°C
5 A 250 VAC (cos
φ
=1) – NC 85°C
50,000
30,000
30,000
6,000
G5RL-U1-E
G5RL-K1-E
Single-winding latching: 3, 5, 6, 12, 24 VDC
Double-winding latching: 5, 12, 24 VDC
SPDT (1c)
16 A 250 VAC (cos
φ
=1) 85°C
G5RL-U1A-EL-HA
G5RL-K1A-EL-HA
Single-winding latching: 5, 12, 24 VDC
Double-winding latching: 5, 12, 24 VDC
IEC60669-1:
16 A 250 VAC Capacitor 140
μ
F
room temperature
SPST-NO (1a)
20,000
●
CQC Certified (File No. CQC21002283993)
Number of
test cycles
Model
Contact form
Coil ratings
Contact ratings
G5RL-U1A-EL-HA
G5RL-K1A-EL-HA
Single-winding latching: 5, 12, 24 VDC
Double-winding latching: 5, 12, 24 VDC
SPST-NO (1a)
16 A 250 VAC (cos
φ
=1) 85°C
6,000
6
G5RL-U/-K
PCB Power Relay
■
Precautions
●
Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●
Basic Operation of Latching Relays
●
Wiring of High-Capacity Models (-E) and In-Rush
Resistance Models (-EL)
• In
these relays, the input pulse of the set coil causes the
operating condition to be maintained magnetically or
mechanicall
y
,
w
hereas the input pulse to the reset coil side
puts the relay into the reset condition.
• High-capacity
models (-E) and In-rush resistance models (-EL)
have a structure that connects two terminals from one contact.
When designing the circuit, use both terminals. If you use only
one terminal, the relay may be unable to satisfy specified
performance.
Set inp
u
t
Reset inp
u
t
N
O contact
N
C contact
●
Precautions for Correct Use
• This
product is not suitable for vehicles such as automobiles
(including two-wheeled vehicles).
• If
the product is used in the following applications, consult your
OMRON sales representative to check the necessary items
according to the specification sheets. Also, make sure the
product is used within the specified ratings and performance
ranges with an ample margin and implement safety measures,
such as designing a safety circuit, to minimize danger should
the product fail.
●
Coil Temperature Rise of Long Time Continuous Current
to the Coil
• When
the coil is applied continuous current for a long time, the
coil would be heated too much.
Please decide the coil input pulse width by “heat and cold of
coil temperature.”
G
5
a. Outdoor use, uses involving potential chemical
contamination or electrical interference.
heat and cold of coil temperature
R
L
100
b. Nuclear energy control systems, combustion systems,
railroad systems, aviation systems, medical equipment,
safety equipment, and equipment that could present a risk
to human life or bod
y
.
80
60
40
U
/
K
c. Equipment requiring a high level of reliabilit
y
,
s
uch as gas,
water, or electrical supply systems.
20
0
0
5
10 15 20 25 30 35 40 45 50 55
60
Time (min
u
te)
Please check each region’s Terms & Conditions by region website.
OMRON Corporation
Device & Module Solutions Company
Regional Contact
Americas
Europe
Asia-Pacific
China
Korea
Japan
© OMRON Corporation 2013-2022
All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
Cat. No. K265-E1-11
1122 (0913)
7