Omron-Electronics-G5SB-14-CB-DC12

Part #Omron-Electronics-G5SB-14-CB-DC12
Download 
Omron-Electronics-G5SB-14-CB-DC12
G5SB  
Compact Single-pole Relay for  
Switching 5 A  
PCB Power Relay  
• Compact SPDT Relay  
• Incorporates a normally open contact that switches 5 A max.  
(N.O. contacts)  
• Small, yet provides 8-kV impulse withstand voltage (between coil  
and contacts)  
• Standard model conforms to UL/CSA/VDE standards.  
RoHS Compliant  
■
Model Number Legend  
■
Application Examples  
• Ideal for output applications of control equipments  
1. Number
 
of Poles
 
2. Enclosure
 
rating  
G
5
S
B
G5SB-

—

1
4

—  

1: 1-pole/SPDT (1c)
 
4: Fully sealed  
1 2  
■
Ordering Information  
■
Characteristics  
Contact resistance *1  
Operate time  
Release time  
100 m
Ω
max.  
10 ms max.  
5 ms max.  
Contact Terminal Enclosure  
Rated coil
 
Minimum  
voltage
packing unit  
Classification  
Model  
form  
Shape  
rating  
5 VDC  
Insulation resistance *2  
1,000 M
Ω
min.  
9 VDC  
12 VDC  
24 VDC  
SPDT  
PCB  
Fully  
100 pcs/  
Tray  
Between coil  
Standard  
G5SB-14  
4,000 VAC, 50/60 Hz for 1 min  
(1c) terminals sealed  
and contacts  
Dielectric  
Between  
strength  
contacts of the  
1,000 VAC, 50/60 Hz for 1 min  
Note. When ordering, add the rated coil voltage to the model number.  
Example: G5SB-14 DC12  
same polarity  
Impulse  
Between coil  
withstand  
and contacts  
voltage  
Rated coil voltage  
However, the notation of the coil voltage on the product case as well as  
on the packing will be marked as
@@
VDC.  
8 kV (1.2 x 50
μ
s)  
Insulation  
distance  
Between coil  
and contacts  
Clearance: 3.5 mm, Creepage: 6.5 mm  
■
Ratings  
10 to 55 to 10 Hz, 0.75 mm single amplitude  
(1.5 mm double amplitude)  
10 to 55 to 10 Hz, 0.75 mm single amplitude  
(1.5 mm double amplitude)  
1,000 m/s

2  

100 m/s

2  

5,000,000 operations  
(18,000 operations per hour)  
200,000 operations: 3 A (NO)/3 A (NC) at  
125 VAC  
50,000 operations: 5 A (NO)/3 A (NC) at  
125 VAC  
50,000 operations: 5 A (NO) at 250 VAC  
100,000 operations: 3 A (NC) at 250 VAC  
100,000 operations: 5 A (NO)/3 A (NC) at  
30 VDC  
Destruction  
Malfunction  
Vibration  
resistance  
●
Coil  
Item  
Must  
operate release  
voltage voltage  
Must  
Max.  
voltage  
(V)  
Destruction  
Malfunction  
Shock  
resistance  
Rated  
current resistance  
Coil  
Power  
consumption  
(mW)  
(V)  
(V)  
(mA)  
(
Ω
)  
Rated  
Mechanical  
voltage  
% of rated voltage  
5 VDC  
80  
63  
150%  
(at  
23°C)  
9 VDC  
12 VDC  
24 VDC  
44.4  
33.3  
16.7  
202  
360  
75%  
max.  
5% min.  
Approx. 400  
Durability  
Electrical  
(resistive load)  
1,440  
Note 1. The rated current and coil resistance are measured at a coil  
temperature of 23°C with a tolerance of ±10%.  
Note 2.
 
The operating characteristics are measured at a coil temperature of 23°C.  
Note 3.
 
The “Max. voltage” is the maximum voltage that can be applied to the relay coil.  
Switching frequency: 1,800 operations per hour  
Failure rate (P level)  
(reference value) *3  
Ambient operating  
temperature  
Ambient operating humidity  
Weight  
10 mA at 5 VDC  
●
Contacts  
–40°C to 70°C with no icing or condensation  
Item  
Load  
Resistive load  
Single  
5% to 85%  
Approx. 6.5 g  
Contact type  
Contact material  
Ag-alloy (Cd free)  
Note. The data shown above are initial values.  
3 A (NO)/3 A (NC) at 125 VAC  
5 A (NO)/3 A (NC) at 125 VAC  
5 A (NO) at 250 VAC  
*1. The
 
contact resistance is possible with 1 A applied at 5 VDC using a fall-  
of-potential method.  
*2. The
 
insulation resistance is possible between coil and contacts and  
between contacts of the same polarity at 500 VDC.  
Rated load  
3 A (NC) at 250 VAC  
5 A (NO)/3 A (NC) at 30 VDC  
*3. This
 
value was measured at a switching frequency of 120 operations/min.  
Rated carry current  
5 A (NO)/3 A (NC)  
250 VAC, 30 VDC  
5 A (NO)/3 A (NC)  
Max. switching voltage  
Max. switching current  
1

G5SB  
Power Relay  
■
Engineering Data  
●
Maximum Switching Capacity  
●
Ambient Temperature vs.  
Maximum Voltage  
7
200  
180  
AC resistive  
(NO)  
6
5
4
3
2
160  
140  
120  
110  
100  
DC resistive  
(NO)  
AC resistive  
(NC)  
80  
60  
40  
DC resistive  
(NC)  
1
0
20  
0
1
10  
30  
100  
250  
1,000  
-40  
-20  
0
23  
40  
60 70 80
 
100  
Note. The maximum voltage is the maximum  
voltage that can be applied to the relay cooil.  
Switching voltage (V)  
Ambient temperature (°C)  
●
Ambient Temperature vs Must  
●
Shock Malfunction  
Operate and Must Release Voltages  
Y
100  
1,000  
Sample:  
G2RL-14-E 24 VDC  
Number of Relays: 5 pcs  
Must operate voltage  
Must release voltage  
NO contact  
90  
80  
70  
60  
50  
40  
30  
20  
10  
Sample: G5SB-14 12 VDC  
Number of Relays: 5 pcs  
X
Z
Conditions: Shock is applied in ±X, ±Y, ±Z  
directions three times each with and without  
energizing the Relays to check the number  
of malfunctions.  
NC contact  
G
5
S
B
1,000  
1,000  
max.  
X
min.  
250  
Requirement: None malfunction 100 m/s

2  

1,000  
X’  
1,000  
Z’  
650  
max.  
X
min.  
Shock direction  
X’  
X
1,000  
Y’  
Unit: m/s

2  

Y
Z
-30 -20 -10  
0
10 20 30 40 50 60 70 80
 
90  
Ambient temperature (°C)  
Z’  
Y’  
■
Dimensions
(Unit: mm)  
PCB Mounting Holes  
(Bottom View)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
G5SB-14  
10.3mꢁx.  
(10.0)*  
20.3mꢁx.  
(20.0)*  
2.54  
Five, 1.3
 
0.1ꢀ-iꢁ. holes  
(1.19)  
2.54  
15.8mꢁx.  
(15.5)*  
2
3
1
5
7.62  
0.4  
3.4  
4
0.4  
10.16  
0.27  
5.08  
1
(No coil polarity)  
2.54  
(1.18)  
10.16  
2.54  
7.62  
5.08  
*Vꢁlues in pꢁrentheses ꢁre ꢁverꢁge vꢁlues.  
■
Approved Standards  
UL Recognized:  
CSA Certified:  
(File No. E41515)  
(File No. LR31928)  
Number of test  
operations  
Model  
Coil ratings  
Contact ratings  
5A 250V AC N.O. only (Resistive) 40°C  
3A 125V AC N.O. only (Resistive) 40°C  
5A 30V DC N.O. only (Resistive) 40°C  
3A 250V AC N.C. only (Resistive) 40°C  
2A 125V AC N.C. only (Resistive) 40°C  
G5SB  
12 to 24 VDC  
6,000  
EN/IEC, VDE Certified:  
(Certificate No. 40003957)  
Number of test  
operations  
10,000  
Model  
G5SB  
Coil ratings  
12, 24 VDC  
Contact ratings  
5A(N.O)/3A(N.C) 250V AC 70°C  
■
Precautions  
●
Please refer to “PCB Relays Common Precautions” for correct use.  
2

G5SB  
ower Relay  
G
5
S
B
•
Applicꢁtion exꢁmples provi-e- in this -ocument ꢁre for reference only. In ꢁctuꢁl ꢁpplicꢁtions, confirm equipment functions ꢁn- sꢁfety before using the pro-uct.  
•
Consult your OMRON representꢁtive before using the pro-uct un-er con-itions which ꢁre not -escribe- in the mꢁnuꢁl or ꢁpplying the pro-uct to nucleꢁr control systems, rꢁilroꢁ-  
systems, ꢁviꢁtion systems, vehicles, combustion systems, me-icꢁl equipment, ꢁmusement mꢁchines, sꢁfety equipment, ꢁn- other systems or equipment thꢁt mꢁy hꢁve ꢁ serious  
influence on lives ꢁn- property if use- improperly. Mꢁke sure thꢁt the rꢁtings ꢁn- performꢁnce chꢁrꢁcteristics of the pro-uct provi-e ꢁ mꢁrgin of sꢁfety for the system or  
equipment, ꢁn- be sure to provi-e the system or equipment with -ouble sꢁfety mechꢁnisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Cat. No. K122-E1-06  
1116(0207)(O)  