Omron-Electronics-G5V-2-H-DC12
| Part # | Omron-Electronics-G5V-2-H-DC12 |
| Download | Omron-Electronics-G5V-2-H-DC12 |
Low Signal Relay
G5V-2
■
Suitable for handling low signals in
computer peripherals, telecommunica-
tions and security equipment
■
Capable of switching loads up to 2 A
■
Conforms to FCC part 68 1500 V surge
withstand
■
Reliable bifurcated crossbar contacts
■
Fully-sealed construction
Ordering Information
To
O
rder: Select the part number and add the desired coil voltage rating (e.g., G5V-2-
DC12
).
T
y
pe
Contact form
DPDT
Construction
Fully-sealed
Part number
G5V-2
Standard
High-sensitivity
Ultra-sensitive
G5V-2-H
G5V-2-H1
Specifications
■
CONTACT DATA
Load
Resistive load (p.f. = 1)
Rated load
0.50 A at 125 VAC
2 A at 30 VDC
Contact material
Carry current
Ag (Au clad)
2 A
Max. operating voltage
125 VAC
125 VDC
Max. operating current
Max. switching capacity
2 A
62.50 VA
60W
Min. permissible load
10
µ
A, 10 mVDC
G5V-2
G5V-2
■
COIL DATA
Standard type
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(
Ω
)
Coil inductance
(Ref. value) (H)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
Armature OFF
Armature ON
0.05
% of rated voltage
3
166.70
100
18
0.04
0.09
0.16
0.31
0.47
1.98
—
75% max.
5% min.
120% max.
Approx. 500
at 65
°
C
(149
°
F)
5
50
0.11
6
83.30
55.60
41.70
20.80
12
72
0.19
9
162
288
1,152
4,000
0.49
12
24
48
0.74
2.68
—
110% max.
Approx. 580
at 60
°
C
(140
°
F)
High-sensitivity type
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(
Ω
)
Coil inductance
(Ref. value) (H)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
Armature OFF
0.04
Armature ON
0.07
% of rated voltage
3
120
72
60
40
30
15
25
75% max.
5% min.
120% max.
Approx. 360
at 70
°
C
(158
°
F)
5
70
0.12
0.19
6
100
225
400
1,600
0.18
0.29
9
0.40
0.62
12
24
0.75
1.18
3.16
4.81
Ultra-sensitive type
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(
Ω
)
Coil inductance
(Ref. value) (H)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
Armature OFF
0.18
Armature ON
0.26
% of rated voltage
3
50
60
75% max.
5% min.
150% max.
Approx. 150
at 70
°
C
(158
°
F)
5
30
166.70
240
0.46
0.71
6
25
0.70
0.97
9
16.70
12.50
8.30
6.25
540
1.67
2.33
12
24
48
960
2.90
3.99
2,880
7,680
6.72
9.27
Approx. 200
Approx. 300
20.10
26.70
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23
°
C (73
°
F) with a tolerance of
±
10%.
2. The
operating characteristics are measured at a coil temperature of 23
°
C (73
°
F).
2
G5V-2
G5V-2
■
CHARACTERISTICS
Contact resistance
Operate time
50 m
Ω
max. G5V-2, G5V-2-H, 100 m
Ω
max. G5V-2-H1
7 ms max. (mean value: approx. 3.5 ms)
3 ms max. (mean value: approx. 0.8 ms)
Mean value: approx. 0.5 ms
Release time
Bounce time
Operate
Release
Mean value: approx. 3.5 ms
Operating frequency
Mechanical
Electrical
36,000 operations/hour
1,800 operations/hour (under rated load)
1,000 M
Ω
min (at 500 VDC)
Insulation resistance
Dielectric strength
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
750 VAC, 50/60 Hz for 1 minute between contacts of same poles
(500
V
AC, 50/60 Hz for 1 minute between contacts of same poles for
ultra-sensitive type)
Surge withstand voltage
Vibration
1,500 V 10 X 160
µ
s (conforms to part 68 of FCC rules)
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
10 to 55 Hz, 1.50 mm (0.59 in) double amplitude
Shock
1,000 m/s
2
(approx. 100 G)
200 m/s
2
(approx. 20 G)
-25
°
to 70
°
C (-13
°
to 158
°
F)
35% to 85% RH
Ambient temperature
Operating/storage
Humidity
Service life
Mechanical
Electrical
15 million operations min. (at operating frequency of 36,000 operations/hour)
See “Characteristic Data”
6 g (0.21 oz)
Weight
Note: Data
shown are of initial value.
■
CHARACTERISTIC DATA
Maximum switching capacity
Electrical service life
Ambient temperature vs.
maximum voltage
Rated operating voltage (V)
Rated operating current (A)
Ambient temperature [
°
C (
°
F)]
—- 48
VDC coil voltage (standard type)
All other types and voltages
3
G5V-2
G5V-2
Dimensions
Unit: mm (inch)
■
REL
A
Y
S
Fully-sealed
Terminal arrangement/Internal
(bottom view)
Mounting holes
(bottom view)
Note: 1.
and
indicate mounting orientation marks.
2. A
tolerance of
±
0.10 (0.004) applies to the above dimensions.
■
APPROVALS
UL (File No. E41515)/CSA (File No. LR24825)
T
y
pe
Contact form
DPDT
Coil rating
Contact ratings
0.6 A, 125 VAC
0.6 A,110 VDC
2.0 A, 30 VDC
0.6 A, 125 VAC
0.6 A, 110 VDC
1.0 A, 24 VDC
G5V-2
G5V-2-H
3 to 48 VDC
3 to 24 VDC
G5V-2-H1
3 to 48 VDC
Note: 1.
The rated values approved by each of the safety standards may be different from the performance characteristics individually
defined in this catalog.
2. In
the interest of product improvement, specifications are subject to change.
Cat. No. GC R
L
Y
6
9/97
Specifications subject to change without notice.
Printed in the U.S.A.
4