Omron-Electronics-G5V-2-H-DC12

Part #Omron-Electronics-G5V-2-H-DC12
Download 
Omron-Electronics-G5V-2-H-DC12
Low Signal Relay  
G5V-2  
■
Suitable for handling low signals in  
computer peripherals, telecommunica-  
tions and security equipment  
■
Capable of switching loads up to 2 A  
■
Conforms to FCC part 68 1500 V surge  
withstand  
■
Reliable bifurcated crossbar contacts  
■
Fully-sealed construction  
Ordering Information  
To
O
rder: Select the part number and add the desired coil voltage rating (e.g., G5V-2-
DC12
).  
T
y
pe  
Contact form  
DPDT  
Construction  
Fully-sealed  
Part number  
G5V-2  
Standard  
High-sensitivity  
Ultra-sensitive  
G5V-2-H  
G5V-2-H1  
Specifications  
■
CONTACT DATA  
Load  
Resistive load (p.f. = 1)  
Rated load  
0.50 A at 125 VAC  
2 A at 30 VDC  
Contact material  
Carry current  
Ag (Au clad)  
2 A  
Max. operating voltage  
125 VAC  
125 VDC  
Max. operating current  
Max. switching capacity  
2 A  
62.50 VA  
60W  
Min. permissible load  
10
µ
A, 10 mVDC  

G5V-2  
G5V-2  
■
COIL DATA  
Standard type  
Rated  
voltage  
(VDC)  
Rated  
current  
(mA)  
Coil  
resistance  
(
Ω
)  
Coil inductance  
(Ref. value) (H)  
Pick-up  
voltage  
Dropout  
voltage  
Maximum  
voltage  
Power  
consumption  
(mW)  
Armature OFF  
Armature ON  
0.05  
% of rated voltage  
3
166.70  
100  
18  
0.04  
0.09  
0.16  
0.31  
0.47  
1.98  
—
75% max.
 
5% min.  
120% max.
 
Approx. 500  
at 65
°
C  
(149
°
F)  
5
50  
0.11  
6
83.30  
55.60  
41.70  
20.80  
12  
72  
0.19  
9
162  
288  
1,152  
4,000  
0.49  
12  
24  
48  
0.74  
2.68  
—
110% max.
 
Approx. 580  
at 60
°
C  
(140
°
F)  
High-sensitivity type  
Rated  
voltage  
(VDC)  
Rated  
current  
(mA)  
Coil  
resistance  
(
Ω
)  
Coil inductance  
(Ref. value) (H)  
Pick-up  
voltage  
Dropout  
voltage  
Maximum  
voltage  
Power  
consumption  
(mW)  
Armature OFF  
0.04  
Armature ON  
0.07  
% of rated voltage  
3
120  
72  
60  
40  
30  
15  
25  
75% max.
 
5% min.  
120% max.
 
Approx. 360  
at 70
°
C  
(158
°
F)  
5
70  
0.12  
0.19  
6
100  
225  
400  
1,600  
0.18  
0.29  
9
0.40  
0.62  
12  
24  
0.75  
1.18  
3.16  
4.81  
Ultra-sensitive type  
Rated  
voltage  
(VDC)  
Rated  
current  
(mA)  
Coil  
resistance  
(
Ω
)  
Coil inductance  
(Ref. value) (H)  
Pick-up  
voltage  
Dropout  
voltage  
Maximum  
voltage  
Power  
consumption  
(mW)  
Armature OFF  
0.18  
Armature ON  
0.26  
% of rated voltage  
3
50  
60  
75% max.
 
5% min.  
150% max.
 
Approx. 150  
at 70
°
C  
(158
°
F)  
5
30  
166.70  
240  
0.46  
0.71  
6
25  
0.70  
0.97  
9
16.70  
12.50  
8.30  
6.25  
540  
1.67  
2.33  
12  
24  
48  
960  
2.90  
3.99  
2,880  
7,680  
6.72  
9.27  
Approx. 200  
Approx. 300  
20.10  
26.70  
Note: 1.
 
The rated current and coil resistance are measured at a coil temperature of 23
°
C (73
°
F) with a tolerance of
±
10%.  
2. The
 
operating characteristics are measured at a coil temperature of 23
°
C (73
°
F).  
2

G5V-2  
G5V-2  
■
CHARACTERISTICS  
Contact resistance  
Operate time  
50 m
Ω
max. G5V-2, G5V-2-H, 100 m
Ω
max. G5V-2-H1  
7 ms max. (mean value: approx. 3.5 ms)  
3 ms max. (mean value: approx. 0.8 ms)  
Mean value: approx. 0.5 ms  
Release time  
Bounce time  
Operate  
Release  
Mean value: approx. 3.5 ms  
Operating frequency  
Mechanical  
Electrical  
36,000 operations/hour  
1,800 operations/hour (under rated load)  
1,000 M
Ω
min (at 500 VDC)  
Insulation resistance  
Dielectric strength  
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts  
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles  
750 VAC, 50/60 Hz for 1 minute between contacts of same poles  
(500
V
AC, 50/60 Hz for 1 minute between contacts of same poles for  
ultra-sensitive type)  
Surge withstand voltage  
Vibration  
1,500 V 10 X 160
µ
s (conforms to part 68 of FCC rules)  
Mechanical durability  
Malfunction durability  
Mechanical durability  
Malfunction durability  
10 to 55 Hz, 1.50 mm (0.59 in) double amplitude  
Shock  
1,000 m/s

2

(approx. 100 G)  
200 m/s

2

(approx. 20 G)  
-25
°
to 70
°
C (-13
°
to 158
°
F)  
35% to 85% RH  
Ambient temperature
 
Operating/storage  
Humidity  
Service life  
Mechanical  
Electrical  
15 million operations min. (at operating frequency of 36,000 operations/hour)  
See “Characteristic Data”  
6 g (0.21 oz)  
Weight  
Note: Data
 
shown are of initial value.  
■
CHARACTERISTIC DATA  
Maximum switching capacity  
Electrical service life  
Ambient temperature vs.  
maximum voltage  
Rated operating voltage (V)  
Rated operating current (A)  
Ambient temperature [
°
C (
°
F)]  
—- 48
 
VDC coil voltage (standard type)  
All other types and voltages  
3

G5V-2  
G5V-2  
Dimensions  
Unit: mm (inch)  
■
REL
A
Y
S  
Fully-sealed  
Terminal arrangement/Internal  
(bottom view)  
Mounting holes  
(bottom view)  
Note: 1.  
and  
indicate mounting orientation marks.  
2. A
 
tolerance of
±
0.10 (0.004) applies to the above dimensions.  
■
APPROVALS  
UL (File No. E41515)/CSA (File No. LR24825)  
T
y
pe  
Contact form  
DPDT  
Coil rating  
Contact ratings  
0.6 A, 125 VAC  
0.6 A,110 VDC  
2.0 A, 30 VDC  
0.6 A, 125 VAC  
0.6 A, 110 VDC  
1.0 A, 24 VDC  
G5V-2  
G5V-2-H  
3 to 48 VDC  
3 to 24 VDC  
G5V-2-H1  
3 to 48 VDC  
Note: 1.
 
The rated values approved by each of the safety standards may be different from the performance characteristics individually  
defined in this catalog.  
2. In
 
the interest of product improvement, specifications are subject to change.  
Cat. No. GC R
L
Y
6  
9/97  
Specifications subject to change without notice.  
Printed in the U.S.A.  
4