Omron-Electronics-G6B-1114C-US-DC12
| Part # | Omron-Electronics-G6B-1114C-US-DC12 |
| Download | Omron-Electronics-G6B-1114C-US-DC12 |
G6B
PCB Power Relay
High Capacity and High
Dielectri
c
S
trengt
h
M
iniature
Relay with Fully Sealed
Construction in 5 A (8 A)
SPST-NO(1a),
SPST-NO+SPST-NC(1a1b),
DPST-NO(2a),
DPST-NC(2b) Types
• P6B model for connecting sockets are available.
• High insulation with dielectric strength of 3,000VAC
between coil and contacts (impulse withstand voltage of
6 kV).
G
6
B
• Standard model conforms to UL/CSA standards.
• AgSnIn contacts suitable for loads that generate surge voltage (inductive load, capacity load, etc.) are available. (-FD type)
• Ultrasonic cleanable models are available. (-U type)
• Operation indicator & built-in surge absorption diode models are available. (-ND type)
• 2-Pole type available.
• High-reliability models are available.
G6B-1184P-US model (The relay used in Terminal Relay G6B-48BND)
■
Application Examples
RoHS Compliant
• Ideal for output applications of control equipments
■
Model Number Legend
G6B
@
–
@
@@@@
–
@
–
–
@
–
@
–
@
–
@
–
@
1
2
3 4 5
6
7
8
9
10 11
1. Relay
Function
4. Enclosure
rating
8. Operation
Indicator Diode
Availability
None: Single-side stable
4: Fully sealed
U
K
: Single-winding latching
(G6B
@
-1114 models only)
: Double-winding latching
(G6B
@
-1114 models only)
7: Flux protection
None: Standard
ND :
Operation indicator & coil surge
absorption diode
5. Terminal
Shape
P: Straight PCB terminals
(for -1177 type only)
Socket mounting terminals
C: Self-clinching PCB
2. Contact
Form
21: SPST-NO + SPST-NC
22: DPST-NO
9. Approved
Standards
US: UL/CSA
6. Contact
material
None: Standard (Ag-alloy (Cd free))
FD :
AgSnIn contact
10. Washability
20: DPST-NC
None: Standard
11: SPST-NO
(Suitable for DC inductive load with
high inrush current)
U :
For ultrasonically cleanable
3. Classification
1: Standard
11. Mounting
7. Coil
Polarity
None: Mounted directly to PCB
P6B : Mounted to Socket
7: High-capacity
8: Single crossbar
None: 5, 6 Terminal (+), 1, 2 Terminal (-)
1
: 5, 6 Terminal (-), 1, 2 Terminal (+)
1
G6B
■
Ordering Information
PCB Power Relay
●
Standard Models (UL, CSA certified)
Contact material
Terminals
Standard (Ag-alloy (Cd free))
Model Rated
coil voltage
AgSnIn contact
Minimum
packing unit
Number
of poles
Relay Function
Contact form
Model
Rated coil voltage
5, 6, 12, 24 VDC
Straight PCB
G6B-1114P-US
5, 6, 12, 24 VDC
G6B-1114P-FD-US
SPST-NO (1a)
(Standard)
100
pcs/tray
Self-clinching
G6B-1114C-US
PCB
5, 6, 12, 24 VDC
G6B-1114C-FD-US
5, 6, 12, 24 VDC
G6B-1174P-FD-US
12, 24 VDC
5, 6, 12, 24 VDC
5, 12, 24 VDC
—
Straight PCB
G6B-1174P-US
Single-side
stable
SPST-NO (1a)
(High-capacity)
20
pcs/tube
Self-clinching
G6B-1174C-US
PCB
5, 12, 24 VDC
5, 12, 24 VDC
—
G6B-1174C-FD-US
Straight PCB
G6B-1184P-US
—
—
SPST-NO (1a)
(High-reliability )
Self-clinching
PCB
—
—
1-pole
Straight PCB
G6BU-1114P-US
5, 6, 12, 24 VDC
G6BU-1114P-FD-US
12 VDC
—
5, 12, 24 VDC
—
Single-winding SPST-NO
(1a)
latching (Standard)
Self-clinching
G6BU-1114C-US
PCB
Straight PCB
G6BK-1114P-US
5, 6, 12, 24 VDC
G6BK-1114P-FD-US
5, 6, 12, 24 VDC
G6BK-1114C-FD-US
5, 6, 12, 24 VDC
24 VDC
Double-winding SPST-NO
(1a)
Self-clinching
G6BK-1114C-US
PCB
latching
(Standard)
SPST-NO (1a)
(Built-in high-
capacit
y
o
peration
indicator & diode)
Straight PCB
G6B-1177P-ND-US
5, 12, 24 VDC
5, 12, 24 VDC
G6B-1177P-FD-ND-US
5, 12, 24 VDC
G6B-1177C-FD-ND-US
12, 24 VDC
Single-side
stable
100
pcs/tray
Self-clinching
G6B-1177C-ND-US
PCB
Straight PCB
G6B-2114P-US
5, 6, 12, 24 VDC
G6B-2114P-FD-US
5, 12, 24 VDC
G6B-2114C-FD-US
5, 6, 12, 24 VDC
G6B-2214P-FD-US
5, 12, 24 VDC
G6B-2214C-FD-US
5, 6, 12, 24 VDC
5, 12 VDC
G
6
B
SPST-NO (1a)+
SPST-NC (1b)
(Standard)
Self-clinching
G6B-2114C-US
PCB
Straight PCB
G6B-2214P-US
5, 6, 12, 24 VDC
5, 12, 24 VDC
5, 6, 12, 24 VDC
12, 24 VDC
Single-side
stable
DPST-NO (2a)
(Standard)
2-pole
Self-clinching
G6B-2214C-US
PCB
Straight PCB
G6B-2014P-US
5, 6, 12, 24 VDC
G6B-2014P-FD-US
5, 6, 12, 24 VDC
G6B-2014C-FD-US
DPST-NC (2b)
(Standard)
Self-clinching
G6B-2014C-US
PCB
Note: AgSnIn contact models are highly welding-resistant, and roughening of contacts due to inrush current and inductive load is lessened.
●
Models for Reverse Coil Polarity
Contact material
Terminals
Standard (Ag-alloy (Cd free))
Model Rated
coil voltage
5, 6, 12, 24 VDC
G6B-1114P-FD-1-US
AgSnIn contact
Minimum
packing unit
Number
of poles
Relay Function
Contact form
Model
Rated coil voltage
24 VDC
Straight PCB
G6B-1114P-1-US
SPST-NO (1a)
(Standard)
100
pcs/tray
Self-clinching
PCB
—
—
—
—
—
—
—
—
—
—
Single-side
stable
Straight PCB
G6B-1174P-1-US
5, 12, 24 VDC
—
SPST-NO (1a)
(High-capacity)
20
pcs/tube
Self-clinching
PCB
—
—
—
1-pole
Straight PCB
G6BU-1114P-1-US
5, 12 VDC
—
Single-winding SPST-NO
(1a)
Self-clinching
PCB
latching
(Standard)
—
—
5, 6, 12, 24 VDC
—
—
Straight PCB
G6BK-1114P-1-US
—
Double-winding SPST-NO
(1a)
Self-clinching
PCB
latching
(Standard)
—
—
100
pcs/tray
Straight PCB
G6B-2114P-1-US
5, 6, 12, 24 VDC
G6B-2114P-FD-1-US
12, 24 VDC
SPST-NO (1a)+
SPST-NC (1b)
(Standard)
Self-clinching
PCB
—
—
5, 12, 24 VDC
—
—
—
—
—
—
—
Single-side
stable
2-pole
Straight PCB
G6B-2214P-1-US
DPST-NO (2a)
(Standard)
Self-clinching
PCB
—
Note: AgSnIn contact models are highly welding-resistant, and roughening of contacts due to inrush current and inductive load is lessened.
2
G6B
●
Models for Ultrasonically Cleanable
PCB Power Relay
Contact material
Terminals
Standard (Ag-alloy (Cd free))
Model Rated
coil voltage
AgSnIn contact
Minimum
packing unit
Number
of poles
Relay Function
Contact form
Model
Rated coil voltage
6, 12, 24 VDC
Straight PCB
G6B-1114P-US-U
5, 6, 12, 24 VDC
G6B-1114P-FD-US-U
Single-side
stable
SPST-NO (1a)
(Standard)
Self-clinching
G6B-1114C-US-U
PCB
5, 12, 24 VDC
24 VDC
—
—
—
—
—
—
—
Straight PCB
G6BU-1114P-US-U
Single-winding SPST-NO
(1a)
latching (Standard)
1-pole
Self-clinching
PCB
—
Straight PCB
G6BK-1114P-US-U
5, 6, 12, 24 VDC
G6BK-1114P-FD-US-U
12, 24 VDC
Double-winding SPST-NO
(1a)
Self-clinching
G6BK-1114C-US-U
PCB
latching
(Standard)
24 VDC
5, 12, 24 VDC
—
—
G6B-2114P-FD-US-U
—
—
100
pcs/tray
Straight PCB
G6B-2114P-US-U
5, 12, 24 VDC
SPST-NO (1a)+
SPST-NC (1b)
(Standard)
Self-clinching
PCB
—
—
5, 12, 24 VDC
—
Straight PCB
G6B-2214P-US-U
5, 6, 12, 24 VDC
G6B-2214P-FD-US-U
Single-side
stable
DPST-NO (2a)
(Standard)
2-pole
Self-clinching
G6B-2214C-US-U
PCB
12, 24 VDC
5, 12, 24 VDC
—
—
G6B-2014P-FD-US-U
—
Straight PCB
G6B-2014P-US-U
5, 12, 24 VDC
—
DPST-NC (2b)
(Standard)
Self-clinching
PCB
—
Note: When ordering, add the rated coil voltage to the model number.
Example: G6B-1114P-US DC5
Rated coil voltage
G
6
B
However, the notation of the coil voltage on the product case as well as on the packing will be marked as
@@
VDC.
●
Connecting Sockets (Sold Separately)
Applicable relay
Model
Minimum ordering unit
G6B-1114P(-FD)-US-P6B
G6B-1174P(-FD)-US-P6B
G6B-1177P(-FD)-ND-US-P6B
G6BU-1114P-US-P6B
P6B-04P
20 pcs
G6BK-1114P-US-P6B
P6B-06P
P6B-26P
G6B-2114P-US-P6B
G6B-2214P-US-P6B
G6B-2014P-US-P6B
Removal Tool
P6B-Y1
P6B-C2
1 pcs
Hold-down Clips
Note 1. G6B-1174P-US-P6B and G6B-1177P-ND-US-P6B are rated for 8 A when mounted on a PCB. However,
when used with the P6B-04P socket models, the allowable current is derated to 5 A.
2
.
T
he P6B sockets are designed to be used with G6B-
@@@@
P(-FD)-US-P6B relays. Only use G6B relays
that include “-P6B” in their model numbers with the sockets. Do not use standard G6B’s that omit “-P6B”
from their model numbers with the sockets.
3
.
T
he hold-down clips of the P6B-C2 model are not suitable for the G6B-1174P and G6B-1177P models
since they have different heights.
4
.
P
roducts with UL/CSA certification marks will be supplied for orders of standard models.
3
G6B
■
Ratings
PCB Power Relay
●
Coil: 1-Pole, Single-side Stable Type
(Including models for ultrasonically cleanable)
Must operate
Must release
Max. voltage
Item
Rated current Coil resistance
Power consumption
(mW)
voltage (V)
voltage (V)
(V)
(mA)
(
Ω
)
Rated voltage
% of rated voltage
5 VDC
6 VDC
40
125
180
33.3
16.7
8.3
160%
(at 23°C)
70% max.
10% min.
Approx. 200
12 VDC
24 VDC
720
2,880
●
Coil: 2-Pole, Single-side Stable Type
(Including models for ultrasonically cleanable)
Must operate
Must release
Max. voltage
Item
Rated current Coil resistance
Power consumption
(mW)
voltage (V)
voltage (V)
(V)
(mA)
(
Ω
)
Rated voltage
% of rated voltage
5 VDC
6 VDC
60
83.3
50
120
480
140%
(at 23°C)
80% max.
10% min.
Approx. 300
12 VDC
24 VDC
25
12.5
1,920
●
Coil: Single-winding Latching Type
(Including models for ultrasonically cleanable)
Must set
Must reset
Max. voltage
Item
Power consumption
Rated
current
(mA)
Coil
resistance
(
Ω
)
voltage (V)
voltage (V)
(V)
Set coil
(mW)
Reset coil
(mW)
% of rated voltage
Rated voltage
5 VDC
6 VDC
40
125
180
G
6
B
33.3
16.7
8.3
160%
(at 23°C)
70% max.
70% max.
200
200
12 VDC
24 VDC
720
2,880
●
Coil: Double-winding Latching Type
(Including models for ultrasonically cleanable)
Must set voltage
Must reset voltage Max. voltage
Rated current (mA)
Coil resistance (
Ω
)
Power consumption
Item
(V)
(V)
(V)
Set coil
(mW)
Reset coil
(mW)
Rated voltage
Set coil
Reset coil
Set coil
Reset coil
% of rated voltage
5 VDC
6 VDC
56
56
89.2
128.5
515
89.2
128.5
515
46.8
23.3
11.7
46.8
23.3
11.7
130%
(at 23°C)
70% max.
70% max.
280
280
12 VDC
24 VDC
2,060
2,060
●
Coil: Operation Indicator Model
(Flux-resistant type. Do not wash down with water.)
Must operate
Must release
Max. voltage
Item
Rated current Coil resistance
Power consumption
(mW)
voltage (V)
voltage (V)
(V)
(mA)
(
Ω
)
Rated voltage
% of rated voltage
5 VDC
12 VDC
24 VDC
43
116
610
Approx. 200
Approx. 240
Approx. 275
130%
(at 23°C)
19.7
11.3
70% max.
10% min.
2,120
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2
.
T
he operating characteristics are measured at a coil temperature of 23°C.
3
.
T
he “Max. voltage” is the maximum voltage that can be applied to the relay coil.
●
Contacts
G6B-1114P(-FD)(-1)-US
G6B-2114P(-FD)(-1)-US
G6B-2214P(-FD)(-1)-US
G6B-2014P(-FD)-US
G6B-2114C(-FD)-US
G6B-2214C(-FD)-US
G6B-2014C(-FD)-US
G6BU-1114P(-FD)(-1)-US
G6BK-1114P(-FD)(-1)-US
G6B-1114C(-FD)-US
G6BU-1114C-US
G6B-1174P(-FD)(-1)-US
G6B-1177P(-FD)-ND-US
G6B-1174C(-FD)-US
Model
Load
G6B-1184P-US
G6B-1177C(-FD)-ND-US
G6BK-1114C(-FD)-US
Inductive load
Inductive load
Inductive load
= 0.4; L/R = 7 ms)
Inductive load
(cos
φ
= 0.4; L/R = 7 ms)
Resistive load
Resistive load
Resistive load
Resistive load
Item
(cos
φ
= 0.4; L/R = 7 ms)
(cos
φ
= 0.4; L/R = 7 ms)
(cos
φ
Contact type
Contact material
Single
Ag-Alloy (Cd free)
Single crossbar
Single
Ag-Alloy (Cd free)
Au-alloy + Ag (Cd free)
5 A (3 A) at 250 VAC
2 A (2 A) at 250 VAC
8 A (5 A) at 250 VAC
2 A (2 A) at 250 VAC
2 A at 250 VAC
0.5 A at 250 VAC
5 A (3 A) at 250 VAC
1.5 A (1.5 A) at 250 VAC
Rated load
5 A (3 A) at 30 VDC
2 A (2 A) at 30 VDC
8 A (5 A) at 30 VDC
2 A (2 A) at 30 VDC
2 A at 30 VDC
0.5 A at 30 VDC
5 A (3 A) at 30 VDC
1.5 A (1.5 A) at 30 VDC
Rated carry current
5 A (5 A)
8 A (5 A)
2A
2A
5 A (5 A)
Max. switching voltage
Max. switching current
380 VAC, 125 VDC
5 A (5 A)
8 A (5 A)
5 A (5 A)
Note 1. The values in the parentheses ( ) are for -FD models only.
2
.
U
se the -FD type for inductive load and switching load which contact roughening is small.
4
G6B
■
Characteristics
PCB Power Relay
G6B-2114P(-FD)(-1)-US
G6B-2214P(-FD)(-1)-US
G6B-2014P(-FD)(-1)-US
G6B-2114C(-FD)-US
G6B-2214C(-FD)-US
G6B-2014C(-FD)-US
G6B-1114P(-FD)(-1)-US
G6B-1174P(-FD)(-1)-US
G6BU-1114P(-FD)(-1)-US G6BK-1114P(-FD)(-1)-US G6B-1177P(-FD)-ND-US
G6B-1114C(-FD)-US
G6B-1174C(-FD)-US
Model
G6B-1184P-US
G6BU-1114C-US
G6BK-1114C(-FD)-US
G6B-1177C(-FD)-ND-US
Single-winding
latching
Double-winding
latching
Built-in operation indicator
& surge absorption diode
Item
Classification Single-side
stable
Single-side stable
Single-side stable
Contact resistance *1
Operate (set) time
30 m
Ω
max.
50 m
Ω
max.
30 m
Ω
max.
10 ms max.
Release (reset) time
Min. set pulse width
Min. reset pulse width
Insulation resistance *2
10 ms max.
−
−
15 ms (at 23°C)
15 ms (at 23°C)
−
−
1,000 M
Ω
min.
Between coil and
contacts
2,000 VAC,
50/60 Hz for 1 min
3,000 VAC, 50/60 Hz for 1 min
3,000 VAC, 50/60 Hz for 1 min
Between contacts
of the same polarity
Between contacts
of different polarity
1,000 VAC, 50/60 Hz for 1 min
Dielectric
strength
2,000 VAC,
50/60 Hz for 1 min
−
Between set and
reset coils
Impulse withstand voltage
(between coil and contacts)
250 VAC,
50/60 Hz for 1 min
−
−
−
6 kV 1.2
×
50
μ
s
4.5 kV 1.2
×
50
μ
s
6 kV 1.2
×
50
μ
s
6 kV 1.2
×
50
μ
s
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s
2
Vibration
resistance
Shock
resistance
G
6
B
100 m/s
2
300 m/s
2
100 m/s
2
50,000,000 operations min. (at 18,000 operations/hr)
Durability
100,000 operation min. (at 1,800 operations/hr under rated load)
10 mA at 5 VDC
1 mA at 1 VDC
-25°C to 70°C (with no icing or condensation)
5% to 85%
Approx. 3.7 g
Approx. 5.4 g
Failure rate (P level)
(reference value) *3
Ambient operating temperature
Ambient operating humidity
Weight
10 mA at 5 VDC
Approx. 4.5 g
Approx. 3.5 to 4.6 g
Approx. 3.5 g
Approx. 3.5 g
Note 1. The values here are initial values.
2
.
T
he G6B-1177P(-FD)-ND model is flux-resistant. Do not wash it down with water.
*1. The
contact resistance was measured with 1 A at 5 VDC using a voltage-drop method.
*2. Measurement
conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was
measured.(Except the location between set/reset coil)
*3. This
value was measured at a switching frequency of 120 operations/min.
5
G6B
■
Engineering Data
PCB Power Relay
●
Maximum Switching Current
G6B-1114P-US
G6B-1174P-FD-US
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
G6B-1174P-US
40
100
100
50
30
50
30
20
10
G6B-2114P-FD-US
G6B-2214P-FD-US
G6B-2014P-FD-US
AC inductive load
(cos
φ
= 0.4)
AC resistive load
AC resistive load
5
10
8
10
AC resistive
load
3
2
5
5
3
2
1.5
1
AC
inductive
load
3
2
DC inductive load
(L/R = 7 ms)
cos
φ
= 0.4
1
DC resistive load
AC
AC
inductive
load
1
resistive
load
DC resistive load
0.5
DC resistive load
0.5
0.3
0.5
0.3
0.3
0.2
DC inductive load
DC inductive load
(L/R = 7 ms)
0.1
0.1
0.1
0
3
5
10 20
30
100
300 500
0
3
5
10
30 50
100
380 1,000
0
3
5
10
30 50
100
300 500 1,000
Switching voltage (V)
Switching voltage (V)
Switching voltage (V)
●
Ambient Temperature vs.
●
Durability
Maximum Coil Voltage
G6B-1114P-US
G6B-1174P-US
G6B-1174P-FD-US
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
G6B-1114P-US
G6B-1174P-US
G6B-1174P-FD-US
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
1
,
000
1
,
000
200
G
6
B
G6B-2114P(-FD)-US
G6B-2214P(-FD)-US
G6B-2014P(-FD)-US
250 VAC/30 VDC inductive load
(cos
φ
= 0.4, L/R = 7 ms)
G6B-1114P-US
250 VAC/30 VDC resistive load
500
300
500
180
G6B-1114P-US
300
100
G6B-1174P-US
G6B-1174P-FD-US
250 VAC/30 VDC resistive load
G6B-1174P-FD-US
160
100
G6B-1174P-US
250 VAC/30 VDC
resistive load
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
140
130
120
110
100
50
30
50
30
250 VAC/30 VDC resistive load
10
10
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
Higher
capacity
G6B-1114P-US
G6B-1174P-FD-US
G6B-1174P-US
G6B-2114P-FD-US
G6B-2214P-FD-US
G6B-2014P-FD-US
250 VAC resistive load
5
3
5
3
80
60
250 VAC/30 VDC inductive load
(cos
φ
= 0.4, L/R = 7 ms)
1
1
0
20 23
30
40
50
60
70
80 90
0
1
2
3
4
5
6
7
8
9
10
0
1 1.5 2
3
4
5
6
7
8
9
10
Ambient temperature (°C)
Switching current (A)
Switching current (A)
Note: The maximum coil voltage refers to the
maxi-mum value in a varying range of
operating power voltage, not a continuous
voltage.
●
Ambient Temperature vs. Must
Operate and Must Release Voltage
G6B-1114P-US
●
Mutual Magnetic Interference
G6B-1114P-US
G6B-1114P-US
Must operate voltage
Must release voltage
Must operate voltage
Must release voltage
100
Sample:
G6B-1114P-US
Number of Relays: 5 pcs
Must operate voltage
Must release voltage
Initial stage
Test
Initial stage
Test
2.54 mm
+
1.0
+
1.0
max.
X
80
60
40
20
+0.5
+0.5
min.
2.54 mm
0
0
Sample
De-energized
−
0.5
−
1.0
−
0.5
Sample
Average value
Average value
−
1.0
max.
De-energized
Initial stage
Initial stage
Test
Test
Sample
X
min.
+
1.0
+
1.0
+0.5
+0.5
Sample
0
0
Energized
−
0.5
−
1.0
−
0.5
−
1.0
0
−
40
−
20
0
20
40
60
80
Average value
Average value
Energized
Ambient temperature (°C)
6
G6B
●
Shock Malfunction
PCB Power Relay
Y
Y
Y
Reset
1ꢀ000
1,000
Energized
Energized
600
Set
300
X
400
Z
X
1,000
X
1ꢀ000
Z
Z
1,000
1ꢀ000
300
700
100
100
200
200
400
X’
1ꢀ000
X’
1,000
Z’
1ꢀ000
Z’
1,000
X’
300
Z’
300
Unit: m/s
2
1,000
Y’
1ꢀ000
Y’
Unit: m/s
2
Unit: m/s
2
Y’
Sample: G6B-1174P-US
G6B-1174P-FD-US
Test Conditions: Shock is applied in
X, Y,
and Z
directions three times each ꢀith ꢀithoꢁt
Sample: G6B-1114P-US
Number of Relays: 12 pcs
T
e
st Conditions: Shock is applied in
Xꢀ
Y
ꢀ
and Z
directions three times each ꢁith ꢁithout
Sample: G6BK-1114P-US
Number of Relays: 12 pcs
T
e
st Conditions: The value at ꢁhich
malfunction occurred ꢁas measured after
applying shock to the
energizing the Relays
to check the nꢁmber of
malfꢁnctions.
energizing the Relays
Shock direction
Shock direction
Shock direction
X
X’
X
X’
to check the number of
malfunctions.
X
X’
test piece 3 times each
in 6 directions along 3
Y
Y
Y
Z
Z’
Z
Z
Reqꢁirement: None
Requirement: None
axes.
Z’
malfꢁction 100 m/s
2
malfuction 100 m/s
2
Z’
Standard value:
300 m/s
2
Y’
Y’
Y’
(Coil)
(Coil)
(Coil)
●
Hot Start
40
40
40
30
Sample: G6B-2114P-US
G6B-2214P-US
Sample: G6B-1114P-US
G6B-1174P-FD-US
Number of Relays: 10 pcs
Test: the variation of operating voltage is measured
based on cold start at 23°Cꢀ during ꢁhich rated
voltage is applied to the coil ꢁith rated
contact current (5A)ꢀ and left for 1
hour each under different
ambient
temperatures.
Sample: G6B-1174P-US
Test: the variation of operating voltage is measꢁred
based on cold start at 23°C, dꢁring ꢀhich rated
voltage is applied to the coil ꢀith rated contact
cꢁrrent (8A), and left for 1 hoꢁr
G6B-2014P-US
30
20
10
0
30
G
6
B
Test: the variation of operating voltage is
measꢁred based on coil cold start at 23°C, dꢁring
ꢀhich rated voltage is applied to the coil ꢀith rated
contact cꢁrrent (5A), and left
each ꢁnder different ambient
20
temperatꢁres.
20
10
0
for 1 hoꢁr each ꢁnder different
ambient temperatꢁres.
120% applied
110% applied
120% applied
110% applied
100% applied
10
0
120% applied
110% applied
100% applied
100% applied
−
10
−
10
−
20
−
10
−
20
−
20
−
50
−
40
−
20
0
20
40
60
80 100
−
50
−
40
−
20
0
20
40
60
80 100
−
50
−
40
−
20
0
20
40
60
80 100
Ambient temperatꢁre (°C)
Ambient temperatꢁre (°C)
Ambient temperature (°C)
■
Dimensions
(Unit: mm)
1-pole Single-side Stable Models (SPST-NO(1a))
Straight PCB
G6B-1114P(-FD)(-1)-US
10 max.
(9.8)*
G6B-1184P-US
10 max.
(9.8)* 0.3
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
3.5
0.85 0.9
<0.9> <1.0>
0.9<1.0>
0.5<0.4>
20 max.
(19.9)*
0.5
2.54
* Average valꢁe
Foꢁr, 1.1-dia. holes
Dimensions in pointed brackets < > are for the
Relay moꢁnted to Socket.
2.54
(1.2)
1
3
4
6
Self-clinching PCB
G6B-1114C(-FD)-US
Note: Check carefꢁlly the coil
polarity of the Relay. Polarity in
the parenthesis is the models for
reverse coil polarity.
10.16
7.62
10 max.
(9.8)*
(1.1)
10 max.
(9.8)* 0.3
Note: Orientation marks are indicated as folloꢀs:
(1.0)
3.2
3.5
(0.8)
0.5
0.85 0.9
20 max.
(19.9)*
0.9
0.5
* Average valꢁe
7
G6B
PCB Power Relay
1-pole Single-side Stable Models
(SPST-NO(1a))
Straight PCB
G6B-1174P(-FD)(-1)-US
10 max.
(9.9)*
12.5 max.
(12.45)* 0.65
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
3.5
0.9
0.85
<1.0>
<0.9>
0.9<1.0>
0.5<0.4>
20.2 max.
(20.0)*
2.54
0.45
Four, 1.1-dia. holes
* Average value
2.54
Dimensions in pointed brackets < > are for the
Relay mounted to Socket.
(1.2)
1
3
4
6
Self-clinching PCB
G6B-1174C(-FD)-US
Note: Check carefully the coil
polarity of the Relay. Polarity in
the parenthesis is the models for
reverse coil polarity.
10 max.
(9.9)*
10.16
7.62
(1.2)
12.5 max.
(12.45)*
0.65
(1.0)
Note: Orientation marks are indicated as follows:
3.2
3.5
(0.8)
0.5
0.85 0.9
0.9
20.2 max.
(20.0)*
0.45
* Average value
1-pole Single-winding Latching Model (SPST-NO(1a))
Straight PCB
G6BU-1114P(-1)-US
10 max.
(9.8)*
G
6
B
10 max.
(9.8)* 0.3
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
3.5
0.85 0.9
<0.9> <1.0>
0.5<0.4>
0.9<1.0>
20 max.
(19.9)*
2.54
* Average value
0.5
Four, 1.1-dia. holes
2.54
Dimensions in pointed brackets < > are for the
Relay mounted to Socket.
(1.2)
1
6
3
4
S
R
Self-clinching PCB
G6BU-1114C-US
Note: Check carefully the coil
polarity of the Relay. Polarity in
the parenthesis is the models
for reverse coil polarity.
S: Set coil
10 max.
(9.8)*
10.16
7.62
(1.1)
10 max.
(9.8)*
0.3
3.5
(1.0)
R: Reset coil
Note: Orientation marks are indicated as follows:
3.2
0.9
(0.8)
0.5
0.85 0.9
20 max.
(19.9)*
* Average value
0.5
1-pole Double-winding Latching Model (SPST-NO(1a))
Straight PCB
G6BK-1114P(-FD)(-1)-US
10 max.
(9.8)*
10 max.
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
(9.8)* 0.3
3.5
0.85
0.9
<0.9>
<1.0>
0.85
0.9<1.0>
0.5<0.4>
* Average value
<0.9>
2.54
20 max.
(19.9)*
Six, 1.1-dia. holes
0.5
2.54
(1.2)
Dimensions in pointed brackets < > are for the
Relay mounted to Socket.
1
6
2
5
3
R
4
S
Self-clinching PCB
G6BK-1114C(-FD)-US
Note: Check carefully the coil
polarity of the Relay. Polarity in
the parenthesis is the models
for reverse coil polarity.
S: Set coil
10 max.
(9.8)*
2.54
7.62
7.62
(1.1)
10 max.
(9.8)* 0.3
(1.0)
R: Reset coil
Note: Orientation marks are indicated as follows:
3.2
3.5
(0.8)
0.85
0.85
20 max.
(19.9)*
0.9
0.9
0.5
* Average value
0.5
8
G6B
PCB Power Relay
1-pole Single-side stable Models (SPST-NO (1a)) (Built-in high capacity operation indicator & surge absorption diode)
Straight PCB
20.2 max.
0.45
G6B-1177P(-FD)-ND-US
(20)*
3.7
1.7
10 max.
(9.9)*
LED
1.6
0.3
15 max.
(14.8)*
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
0.65
3.5
0.85 0.9
<0.9> <1.0>
0.9<1.0>
0.5<0.4>
Four, 1.1-dia. holes
2.54
10.16
7.62
7.62
* Average value
1
6
3
4
Dimensions in pointed brackets < > are for the
Relay mounted to Socket.
2.54
7.62
(1.2)
Self-clinching PCB
Note: Check carefully the
coil polarity of the Relay.
20.2 max.
(20)*
(1.11)
10.16
7.62
G6B-1177C(-FD)-ND-US
0.45
3.7
Note: The G6B-1177P-ND-US model has a flux-resistant
construction. Do not wash it down with water. Pay
attention to the polarity of the coil since the LED and
surge absorption diode are built-in.
1.7
10 max.
(9.9)*
G
6
B
LED
1.6
0.3
15 max.
(14.8)*
0.65
(1.0)
3.2
0.9
3.5
(0.8)
0.5
0.85 0.9
10.16
7.62
7.62
* Average value
2-poles Single-side stable Models (SPST-NO (1a) + SPST-NC (1b), DPST-NO (2a), DPST-NC(2b))
Straight PCB
20 max.
(19.9)*
G6B-2114P(-FD)(-1)-US
G6B-2214P(-FD)(-1)-US
G6B-2014P(-FD)-US
11 max.
(10.9)*
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
11 max.
(10.9)*
Six, 1.1-dia. holes
2.54
3.5
G6B-2114
3
0.9<0.8>
0.4<0.3>
1
8
4
5
2.54
10.16
7.62
7.62
7.62
(1.7)
* Average value
6
Dimensions in pointed brackets < > are for the
Relay mounted to Socket.
(1.11)
10.16
7.62
G6B-2014
3
1
8
4
5
Self-clinching PCB
G6B-2114C(-FD)-US
G6B-2214C(-FD)-US
G6B-2014C(-FD)-US
20 max.
(19.9)*
6
11 max.
(10.9)*
G6B-2214
3
1
8
4
5
6
11 max.
(10.9)*
Note: Check carefully the coil
polarity of the Relay. Polarity in
the parenthesis is the models
for reverse coil polarity.
(1.0)
3.2
0.8
3.5
(0.8)
0.3
10.16
7.62
7.62
* Average value
9
G6B
■
Connecting Sockets
Dimensions
PCB Power Relay
Socket for 1-pole Single-winding Latching Model and
Single-side Stable Model
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
23.2 max.
P6B-04P
(23)*
Four, 1.1-dia. holes
10 max.
(9.9)*
2.54
3.1
2.54
2.54
2.54
(1.2)
10.1 max.
(10)*
7
(2.71)
10.16
7.62
3.5
0.8
0.4
10.16
7.62
7.62
* Average value
Socket for 1-pole Double-winding Latching Model
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
P6B-06P
23.2 max.
(23)*
10 max.
(9.9)*
3.1
Six, 1.1-dia. holes
2.54
G
6
B
(1.2)
10.1 max.
(10)*
7
3.5
(2.71)
7.62
7.62
0.8
2.54
0.4
2.54
7.62
7.62
7.62
* Average value
Socket for Double-pole Single-side Stable
P6B-26P
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
23.2 max.
(23)*
11 max.
(10.8)*
3.1
Six, 1.1-dia. holes
2.54
10.1 max.
(10)*
(1.6)
7
3.5
(2.61)
10.16
7.62
0.8
0.4
10.16
7.62
7.62
* Average value
■
Removal Tool
■
Hold-down Clips
■
Related Products
P6B-Y1
P6B-C2
The G6B-4 Terminal Relay series with
4-point output is also available.
For details, contact your OMRON sales
representative.
10
G6B
■
Approved Standards
PCB Power Relay
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm the
values before use.
UL Recognized:
(File No. E41643)
Contact
Number of test
operations
Model
Coil ratings
Contact ratings
form
1
5 A, 250 VAC (General Use) 80°C
5 A, 30 VDC (Resistive) 80°C
1/8HP, 250 VAC 80°C
6,000
G6B-1114P(-FD)(-1)-US
G6B-1114C(-FD)-US
3 to 24
VDC
1,000
1/6HP, 250 VAC 80°C
8 A, 277 VAC (General Use) 80°C
8 A, 30 VDC (Resistive) 80°C
2 A, 250 VAC (General Use) 80°C
2 A, 30 VDC (Resistive) 80°C
30,000
G6B-1174P(-FD)(-1)-US
G6B-1174C(-FD)-US
3 to 24
VDC
1
1
3 to 24
VDC
G6B-1184P-US
G6B-2114P(-FD)(-1)-US
G6B-2214P(-FD)(-1)-US
G6B-2014P(-FD)-US
G6B-2114C(-FD)-US
G6B-2214C(-FD)-US
G6B-2014C(-FD)-US
6,000
5 A, 250 VAC (General Use) 80°C
5 A, 30 VDC (Resistive) 80°C
3 to 24
VDC
2
CSA Certified:
(File No. LR31928)
Contact
Number of test
operations
G
6
B
Model
Coil ratings
Contact ratings
form
5 A, 250 VAC (General Use) 80°C
5 A, 30 VDC (Resistive) 80°C
1/6HP, 250 VAC 80°C
6,000
G6B-1114P(-FD)(-1)-US
G6B-1114C(-FD)-US
3 to 24
VDC
1
1,000
6,000
360 W, 120 VAC tungsten 80°C
8 A, 277 VAC (General Use) 80°C
8 A, 30 VDC (Resistive) 80°C
30,000
G6B-1174P(-FD)(-1)-US
G6B-1174C(-FD)-US
3 to 24
VDC
1
2
G6B-2114P(-FD)(-1)-US
G6B-2214P(-FD)(-1)-US
G6B-2014P(-FD)-US
G6B-2114C(-FD)-US
G6B-2214C(-FD)-US
G6B-2014C(-FD)-US
5 A, 250 VAC (General Use) 80°C
5 A, 30 VDC (Resistive) 80°C
6,000
3 to 24
VDC
EN/IEC, TÜV Certified:
(Registration No. R50158246)
Contact
form
Number of test
operations
Model
Coil ratings
Contact ratings
5 A, 250 VAC (cos
φ
= 1) at 70°C
2 A, 250 VAC(cos
φ
= 0.4) at 70°C
5 A, 30 VDC (L/R = 0 ms) at 70°C
8 A, 250 VAC (cos
φ
= 1) at 70°C
2 A, 250 VAC (cos
φ
= 0.4) at 70°C
8 A, 30 VDC (L/R = 0 ms) at 70°C
G6B-1114P(-1)-US
G6B-1114C-US
5, 6, 12, 24
VDC
1
1
G6B-1174P(-1)-US
G6B-1174C-US
5, 6, 12, 24
VDC
20,000
G6B-2114P(-1)-US
G6B-2214P(-1)-US
G6B-2014P-US
G6B-2114C-US
G6B-2214C-US
G6B-2014C-US
5 A, 250 VAC (cos
φ
= 1) at 70°C
1.5 A, 250 VAC (cos
φ
= 0.4) at 70°C
5 A, 30 VDC (L/R = 0 ms) at 70°C
5, 6, 12, 24
VDC
2
3 A, 250 VAC (cos
φ
= 1) at 70°C
3 A, 30 VDC (L/R = 0 ms) at 70°C
5 A, 250 VAC (cos
φ
= 1) at 70°C
2 A, 250 VAC (cos
φ
= 0.4) at 70°C
5 A, 30 VDC (L/R = 0 ms) at 70°C
G6B-1114P-FD(-1)-US
G6B-1114C-FD-US
5, 6, 12, 24
VDC
1
1
G6B-1174P-FD(-1)-US
G6B-1174C-FD-US
5, 6, 12, 24
VDC
10,000
G6B-2114P-FD(-1)-US
G6B-2214P-FD(-1)-US
G6B-2014P-FD-US
G6B-2114C-FD-US
G6B-2214C-FD-US
G6B-2014C-FD-US
1.5 A, 250 VAC (cos
φ
= 0.4) at 70°C
5, 6, 12, 24
VDC
2
3 A, 30 VDC (L/R = 0 ms) at 70°C
11
G6B
■
Precautions
PCB Power Relay
●
Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●
Mounting
●
Inhibit Circuit of the
●
Other precautions
G6B-1177P(-FD)-ND-US Model
• When installing more than two Relays
side by side on a PCB, keep the gaps
as shown below.
• The P6B model has a flux-resistant
construction. Do not wash it down with
water.
• Do not use under conditions in which a
surge is included in the power supply,
such as when an inductive load is
It may cause a malfunction if heat is
not dissipated smoothly from the
Relay.
• Perform wiring of No.1 and No. 2 of
the X terminal as COM for double-
winding latching as shown below. The
operation stability improves by doing
this.
connected in parallel to the coil. Doing
so will cause damage to the installed
(or built-in) coil surge absorbing diode.
Pitch:
2.54 mm
×
2 min.
between terminals
Coil surge
absorption
diode
Inductive
load
G6B
Coil
L
6
5
R
2
Pitch: 2.54 mm × 2 min.
between terminals
S
• No specified mounting direction.
1
●
Using SPDT contact of the
SPST-NO+SPST-NC Relay
●
Mounting Height of Sockets and
COM
Precautions
• Check carefully the coil polarity (+ and -)
of the Relay G6B-1177P(-FD)-ND-US.
Do not reverse the polarity when
connecting. Otherwise the built-in coil
surge absorption diode may be
damaged.
• Do not construct a circuit so that
overcurrent and burning occur if the
NO, NC and SPDT contacts are
short-circuited with the
G
6
B
* 19.5 mm max. for
*17 mm max.
G6B-1174P-FD-US,
G6B-1174P-US models
7 mm max.
and 22 mm max. for
G6B-1177P-FD-ND-US,
G6B-1177P-ND-US models.
SPST-NO+SPST-NC Relay.Arcing
may generate short-circuiting between
contacts if there is short-circuiting
because of conversion to the MBB
contact caused by asynchronous
operation of the NO and NC contacts,
the interval between the NO and NC
contacts is small, or a large current is
left open.
• Hold-down clips (for mounting and
removal) are also available.(For P6B-
C2 model) However, it is not suitable
for G6B-1174P and G6B-1177P
models.
• This Relay is a Power Relay which is
suitable for power load switching. Do
not use the G6B for signal purposes
such as micro load switching under 10
mA.
• Removal tool is also available.
(For P6B-Y1 model) However, it is not
suitable for G6B-1177P model.
•
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
•
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Cat. No. K021-E1-16
0118(0207)(O)
12