Omron-Electronics-G6CK-1114P-US-DC5

Part #Omron-Electronics-G6CK-1114P-US-DC5
Download 
Omron-Electronics-G6CK-1114P-US-DC5
G6C  
PCB Power Relay  
Miniature High Capacity Relays  
with SPST-NO 10A and SPST-NO +  
SPST-NC 8A  
• SPST-NO 10A and SPST-NO + SPST-NC 8A for power switching and  
output that satisfy the needs for space-saving.  
• Small High-capacity Relays Compact: 20
×
15
×
10 mm (L
×
W
×
H).  
• Low power consumption: 200 mW.  
• Ultrasonically cleanable models is available.  
• Exclusive P6C model for sockets is now available.  
RoHS Compliant  
■
Model Number Legend  
G6C-
@
–
@
@@@@
–
@
–
@
–
@
–
@  
■
Application Examples  
Ideal for output applications of control  
equipments  
1
2
3 4 5  
6
7
8
9
G
6
C
1. Relay
 
Function  
6. Contact
 
Material  
None: Single-side stable  
None: Standard (Ag-alloy (Cd free))  
FD :
 
AgSnIn Contacts  
U
K
: Single-winding latching  
: Double-winding latching  
(Suitable for DC inductive load  
with high inrush current)  
2. Contact
 
Form  
11: SPS
T
–
NO (1a)  
7. Approved
 
Standards  
21: SPS
T
–
NO (1a) + SPS
T
–
NC (1b)  
US: UL/CSA  
3. Contact
 
Type  
8. Washability  
1: Single  
None: Standard model  
(not compatible with ultrasonically  
cleanable models)  
4. Enclosure
 
rating  
4: Fully sealed  
U
: For ultrasonically cleanable  
7: Flux protection  
9. Mounting  
5. Terminal
 
Shape  
P: PCB terminals  
None: Mounted directly to PCB  
P6C : Mounted to Socket  
Socket mounting
T
e
rminals  
C: Self-clinching PCB  
1

G6C  
PCB Power Relay  
■
Ordering Information  
●
Standard Models (UL, CSA certified)  
Relay Function  
Single-side stable  
Single-winding latching  
Double-winding latching  
Minimun  
packing  
unit  
Enclosure  
rating  
Rated coil  
voltage  
Rated coil  
Rated coil  
voltage  
Model  
Model  
Model  
Contact form  
Terminals  
voltage  
3 VDC  
5 VDC  
−
3 VDC  
5 VDC  
6 VDC  
12 VDC  
24 VDC  
5 VDC  
12 VDC  
24 VDC  
3 VDC  
5 VDC  
12 VDC  
24 VDC  
3 VDC  
5 VDC  
6 VDC  
12 VDC  
24 VDC  
5 VDC  
12 VDC  
24 VDC  
3 VDC  
5 VDC  
6 VDC  
12 VDC  
24 VDC  
3 VDC  
5 VDC  
6 VDC  
12 VDC  
24 VDC  
−
G6C-1117P-US  
G6CU-1117P-US  
G6CK-1117P-US  
12 VDC  
24 VDC  
5 VDC  
Straight PCB  
SPS
T
–
NO (1a)  
G6C-1117P-FD-US  
G6C-1117C-US  
G6CU-1117P-FD-US
12 VDC  
G6CK-1117P-FD-US
12 VDC  
24 VDC  
−
−
−
−
−
G6CK-1117C-US  
12 VDC  
Self-clinching  
PCB  
−
−
−
24 VDC  
3 VDC  
5 VDC  
Flux  
protection  
100 pcs/  
tray  
3 VDC  
5 VDC  
G6C-2117P-US  
G6C-2117P-FD-US  
G6C-2117C-US  
G6CU-2117P-US  
6 VDC  
12 VDC  
24 VDC  
5 VDC  
G6CK-2117P-US  
G6CK-2117P-FD-US  
G6CK-2117C-US  
6 VDC  
12 VDC  
24 VDC  
5 VDC  
−
Straight PCB  
SPS
T
–
NO (1a) +  
SPS
T
–
NC (1b)  
G
6
C
G6CU-2117P-FD-US
12 VDC  
24 VDC  
−
24 VDC  
3 VDC  
5 VDC  
−
5 VDC  
Self-clinching  
PCB  
G6CU-2117C-US  
−
12 VDC  
−
12 VDC  
24 VDC  
Relay Function  
Terminals  
Single-side stable  
Single-winding latching  
Double-winding latching  
Minimun  
packing  
unit  
Enclosure  
rating  
Rated coil  
voltage  
Rated coil  
voltage  
Rated coil  
Model  
Model  
Model  
Contact form  
voltage  
3 VDC  
5 VDC  
6 VDC  
12 VDC  
24 VDC  
5 VDC  
3 VDC  
5 VDC  
6 VDC  
12 VDC  
24 VDC  
5 VDC  
12 VDC  
24 VDC  
3 VDC  
5 VDC  
12 VDC  
24 VDC  
3 VDC  
5 VDC  
6 VDC  
12 VDC  
24 VDC  
5 VDC  
12 VDC  
24 VDC  
3 VDC  
5 VDC  
6 VDC  
12 VDC  
24 VDC  
3 VDC  
5 VDC  
6 VDC  
12 VDC  
24 VDC  
5 VDC  
G6C-1114P-US  
G6CU-1114P-US  
G6CK-1114P-US  
Straight PCB  
SPS
T
–
NO (1a)  
G6C-1114P-FD-US  
G6C-1114C-US  
G6CU-1114P-FD-US
12 VDC  
G6CK-1114P-FD-US
12 VDC  
24 VDC  
24 VDC  
3 VDC  
−
−
G6CU-1114C-US  
12 VDC  
5 VDC  
G6CK-1114C-US  
12 VDC  
Self-clinching  
PCB  
−
24 VDC  
3 VDC  
5 VDC  
Fully  
sealed  
100 pcs/  
tray  
3 VDC  
5 VDC  
G6C-2114P-US  
G6C-2114P-FD-US  
G6C-2114C-US  
G6CU-2114P-US  
6 VDC  
12 VDC  
24 VDC  
5 VDC  
G6CK-2114P-US  
G6CK-2114P-FD-US  
G6CK-2114C-US  
6 VDC  
12 VDC  
24 VDC  
−
Straight PCB  
SPS
T
–
NO (1a) +  
SPS
T
–
NC (1b)  
G6CU-2114P-FD-US
12 VDC  
−
24 VDC  
−
24 VDC  
−
5 VDC  
5 VDC  
6 VDC  
12 VDC  
24 VDC  
Self-clinching  
PCB  
G6CU-2114C-US  
−
−
−
Note. When ordering, add the rated coil voltage to the model number.  
Example: G6C-1117P-US DC3  
Rated coil voltage  
However, the notation of the coil voltage on the product case as well as on the packing will be marked as
@@
VDC.  
2

G6C  
●
Ultrasonically Cleanable Models (UL, CSA certified)  
PCB Power Relay  
Relay Function  
Single-side stable  
Single-winding latching  
Double-winding latching  
Minimun  
packing  
unit  
Enclosure  
rating  
Rated coil  
Rated coil  
voltage  
Rated coil  
voltage  
Model  
Model  
Model  
Contact form  
Terminals  
voltage  
3 VDC  
−
−
5 VDC  
5 VDC  
5 VDC  
Straight PCB
 
G6C-1114P-US-U  
6 VDC  
G6CU-1114P-US-U  
−
G6CK-1114P-US-U  
−
SPS
T
–
NO (1a)  
12 VDC  
24 VDC  
12 VDC  
24 VDC  
5 VDC  
12 VDC  
12 VDC  
−
−
−
−
−
−
−
−
−
24 VDC  
−
Self-clinching  
G6C-1114C-US-U  
PCB  
−
−
−
100 pcs/  
tray  
Fully sealed  
−
5 VDC  
Straight PCB
 
G6C-2114P-US-U  
12 VDC  
24 VDC  
5 VDC  
G6CK-2114P-US-U  
12 VDC  
−
−
−
−
SPS
T
–
NO (1a) +  
SPS
T
–
NC (1b)  
Self-clinching  
G6C-2114C-US-U  
PCB  
12 VDC  
24 VDC  
−
−
Note. When ordering, add the rated coil voltage to the model number.  
Example: G6C-1114P-US-U DC3  
Rated coil voltage  
However, the notation of the coil voltage on the product case as well as on the packing will be marked as
@@
VDC.  
●
Connecting Sockets (Sold Separately)  
Applicable relays  
Model  
Minimun packing unit  
G
6
C
G6C-2114P-US-P6C  
G6C-2117P-US-P6C  
G6C-1114P-US-P6C  
G6C-1117P-US-P6C  
G6CU-2114P-US-P6C  
G6CU-2117P-US-P6C  
G6CU-1114P-US-P6C  
G6CU-1117P-US-P6C  
P6C-06P  
20 pcs/tube  
G6CK-2114P-US-P6C  
G6CK-2117P-US-P6C  
G6CK-1114P-US-P6C  
G6CK-1117P-US-P6C  
P6C-08P  
Removal Tool  
P6B-Y1  
P6B-C2  
1
Hold-down Clips  
Note 1. Use the G6C-
@@@@
P-US-P6C to mount to a P6C Socket.  
2. When using by combining sockets, the rated current will be 5A due to its rated switching current.  
3

G6C  
PCB Power Relay  
■
Ratings  
Coil: 1-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)  
Item  
Must operate
 
Must release  
Max.  
voltage  
(V)  
Rated  
current  
(mA)  
Coil  
resistance  
(
Ω
)  
Power  
consumption  
(mW)  
voltage  
(V)  
voltage  
(V)  
Rated voltage  
% of rated voltage  
3 VDC  
5 VDC  
67  
45  
125  
40  
160%  
(at 23°C)  
6 VDC  
33.3  
16.7  
8.3  
180  
70% max.  
10% min.  
Approx. 200  
12 VDC  
24 VDC  
720  
2,880  
Coil: Single-winding Latching Type (Including models for ultrasonically cleanable)  
Item  
Must set
 
Must reset  
Max.  
voltage  
(V)  
Power consumption  
Rated  
current  
(mA)  
Coil  
resistance  
(
Ω
)  
voltage  
(V)  
voltage  
(V)  
Set coil  
(mW)  
Reset coil  
(mW)  
Rated voltage  
% of rated voltage  
3 VDC  
5 VDC  
67  
45  
125  
40  
160%  
(at 23°C)  
6 VDC  
33.3  
16.7  
8.3  
180  
70% max.
 
70% max.  
200  
200  
12 VDC  
24 VDC  
720  
2,880  
Coil: Double-winding Latching Type (Including models for ultrasonically cleanable)  
Item  
Rated current (mA)  
Set coil
 
Reset coil  
93.5 93.5  
Coil resistance (
Ω
)  
Must set  
voltage  
(V)  
Must reset  
voltage  
(V)  
Max.  
voltage  
(V)  
Power consumption  
G
6
C
Set coil  
(mW)  
Reset coil  
(mW)  
Set coil
 
Reset coil  
Rated voltage  
% of rated voltage  
3 VDC  
5 VDC  
32.1  
89.3  
32.1  
89.3  
56.0  
46.7  
23.3  
11.7  
56.0  
46.7  
23.3  
11.7  
130%  
(at 23°C)  
6 VDC  
129  
129  
70% max.  
70% max.  
280  
280  
12 VDC  
24 VDC  
514  
514  
2,056  
2,056  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.  
2
.
T
he operating characteristics are measured at a coil temperature of 23°C.  
3
.
T
he “Max. voltage” is the maximum voltage that can be applied to the relay coil.  
Contact  
Contact Form  
Rated load  
SPS
T
–
NO (1a)  
SPS
T
–
NO (1a) + SPS
T
–
NC (1b)  
Inductive load  
Inductive load  
(cos
φ
= 0.4; L/R = 7 ms)  
Resistive load  
Resistive load  
(cos
φ
= 0.4; L/R = 7 ms)  
10 A (8 A) at 250 VAC  
10 A (10 A) at 30 VDC  
5 A (5 A) at 250 VAC  
5 A (5 A) at 30 VDC  
8 A (8 A) at 250 VAC  
8 A (8 A) at 30 VDC  
3.5 A (3.5 A) at 250 VAC  
3.5 A (3.5 A) at 30 VDC  
Item  
Contact type  
Contact material  
Single  
Ag-Alloy (Cd free)  
Rated carry current  
10 A (10 A)  
10 A (10 A)  
8 A (8 A)  
8 A (8 A)  
Max. switching voltage  
Max. switching current  
380 VAC, 125 VDC  
Note. The values shown in parentheses (
 
) are for -FD models only.  
4

G6C  
PCB Power Relay  
■
Characteristics
(Including models for ultrasonically cleanable)  
Item  
Classification  
Single-side Stable  
Single-winding Latching
 
Double-winding Latching  
30 m
 
max.  
Contact resistance *1  
Operate (set) time  
Release (reset) time  
Min. set pulse width  
Min. reset pulse width  
Ω
10 ms max.  
10 ms max.  
−
−
20 ms (at 23°C)  
20 ms (at 23°C)  
Between coil and  
1,000 M  
1,000 M  
Ω
Ω
min.  
min.  
contacts  
Between contacts of the  
same polarity  
Insulation  
resistance *2  
Between contacts of  
different polarity  
Between set and reset  
coils  
1,000 M  
Ω
min. (SPS
T
–
NO, SPS
T
–
NC)  
1,000 M
Ω
min.  
−
−
Between coil and  
contacts  
Between contacts of the  
same polarity  
2,000 VAC 50/60Hz for 1min  
1,000 VAC 50/60Hz for 1min  
Dielectric  
strength  
Between contacts of  
different polarity  
2,000 VAC 50/60Hz for 1min (SPS
T
–
NO, SPS
T
–
NC)  
250 VAC 50/60Hz for  
1min  
Between set and reset  
coils  
−
−
Destruction  
Malfunction  
Destruction  
Malfunction  
Mechanical  
Electrical  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
Vibration  
resistance  
1,000 m/s

2  

100 m/s

2  

Shock  
resistance  
Note. The given values are initial values.  
*1. Measurement
 
conditions: 5 VDC, 1 A, voltage  
drop method.  
*2. Testing
 
conditions: measured with a 500 VDC  
megohmmeter (at 250 VDC between set/reset  
coil).  
*3. This
 
value was measured at a switching  
frequency of 120 operations/min.  
50,000,000 operations min. (at 18,000 operations/hr)  
100,000 operation min. (at 1,800 operations/hr under rated load)  
10 mA at 5 VDC  
Durability  
G
6
C
Failure rate (P level) (reference value) *3  
Ambient operating temperature  
Ambient operating humidity  
Weight  
-25°C to 70°C (with no icing or condensation)  
5% to 85%  
Approx. 5.6 g  
■
Engineering Data  
●
Maximum Switching Capacity  
G6C-1114
@
-US  
G6C-1117
@
-US  
G6C-1114
@
-FD-US  
G6C-1117
@
-FD-US  
50  
50  
30  
30  
AC resistive load  
AC resistive load  
10  
10  
8
7
5
5
3
3
AC inductive  
DC resistive load  
AC inductive  
load  
(cos
φ
= 0.4)  
2
load  
DC resistive load  
(cos
φ
= 0.4)  
DC inductive load  
(L/R = 7 ms)  
1
0.7  
0.5  
1
0.7  
0.5  
DC inductive load  
(L/R = 7 ms)  
0.3  
0.2  
0.3  
0.2  
0.1  
0.1  
1
3
5
7 10  
30 50
 
100  
250 380
 
1,000  
1
3
5
7 10  
30 50
 
100  
250 380
 
1,000  
Switching voltage (V)  
Switching voltage (V)  
G6C-2114
@
-US  
G6C-2117
@
-US  
G6C-2114
@
-FD-US  
G6C-2117
@
-FD-US  
50  
50  
30  
30  
AC resistive load  
AC resistive load  
10  
8
10  
8
5
5
3
3
2
DC resistive load  
AC inductive  
load  
(cos
φ
= 0.4)  
2
AC inductive  
load  
(cos
φ
= 0.4)  
DC inductive load  
(L/R = 7 ms)  
DC resistive load  
1
1
0.7  
0.5  
0.7  
0.5  
DC inductive load  
(L/R = 7 ms)  
0.3  
0.2  
0.3  
0.2  
0.1  
0.1  
1
3
5
7 10  
30 50
 
100  
250 380
 
1,000  
1
3
5
7 10  
30 50
 
100  
250 380
 
1,000  
Switching voltage (V)  
Switching voltage (V)  
5

G6C  
PCB Power Relay  
●
Durability  
G6C-1114
@
-US, G6C-2114
@
-US  
G6C-1114  
G6C-1117  
500  
@
-FD-US, G6C-2114  
-FD-US, G6C-2117  
@
-FD-US  
-FD-US  
G6C-1117
@
-US, G6C-2117
@
-US  
@
@
500  
300  
G6C-2114
@
-FD-US  
G6C-2117
@
-FD-US  
250
V
AC resisti
v
e  
30
V
DC resisti
v
e  
300  
G6C-1114
@
-FD-US  
G6C-1117
@
-FD-US  
250
V
AC resisti
v
e  
G6C-2114
@
-US  
100  
100  
G6C-2117
@
-US  
250
V
AC resisti
v
e  
G6C-1114
@
-US  
G6C-1114
@  
-FD-US  
G6C-1117
@  
-FD-US  
50  
30  
30
V
DC resisti
v
e  
50  
30  
G6C-1117
@
-US  
250
V
AC resisti
v
e  
30
V
DC resisti
v
e  
30
V
DC resisti
v
e  
10  
10  
G6C-2114
@
-US  
G6C-1114
@
-US  
G6C-1114
@
-FD-US  
G6C-2114
@
-FD-US  
G6C-2117
@
-FD-US  
250
V
AC ind
u
cti
v
e  
(cos
φ
= 0.4)  
G6C-2117
@
-US  
250
V
AC ind
u
cti
v
e  
(cos
φ
= 0.4)  
5
3
5
3
G6C-1117
@
-US  
250
V
AC ind
u
cti
v
e  
(cos
φ
= 0.4)  
G6C-1117
@
-FD-US  
250
V
AC ind
u
cti
v
e  
(cos
φ
= 0.4)  
30
V
DC ind
u
cti
v
e  
(L/R = 7 ms)  
30
V
DC ind
u
cti
v
e  
(L/R = 7 ms)  
30
V
DC ind
u
cti
v
e  
(L/R = 7 ms)  
30
V
DC ind
u
cti
v
e  
(L/R = 7 ms)  
1
1
0
1
2
3
4
5
6
7
8
9
10 11  
0
1
2
3
4
5
6
7
8
9
10 11  
S
w
itching c
u
rrent (A)  
S
w
itching c
u
rrent (A)  
●
Ambient Temperature vs.  
Maximum Coil Voltage  
200  
●
Ambient Temperature vs Must  
Operate and Must Release voltages  
100  
Must operate voltage  
Sample:  
G6C-114P-US  
Number of Relays:  
5 pcs  
Must release voltage  
180  
160  
max.  
80  
60  
40  
20  
X
min.  
G
6
C
140  
130  
120  
max.  
100  
X
min.  
80  
60  
0
-40  
10 20
 
23 30  
40  
50  
60  
70  
80 90  
-20  
0
20  
40  
60  
80  
Ambient temperature (°C)  
Ambient temperature (°C)  
Note. The maximum coil voltage refers to the  
maximum value in a varying range of  
operating power voltage, not a continuous  
voltage.  
●
Shock Malfunction  
●
Magnetic Interference (between Relays)  
De-energized  
(b contact)  
Energized  
(a contact)  
3
Y
Y
600  
600  
2
400  
200  
400  
200  
X
600  
Z
600  
X
600  
Z
600  
1
max.  
400  
400  
400  
400  
400  
400  
X
min.  
200  
200  
200  
200  
200  
200  
0
l
2
200  
200  
Sample  
200  
400  
200  
400  
500  
-1  
400  
600  
X’  
600  
X’  
Z’  
600  
Z’  
600  
l
1
Shock direction  
-2  
-3  
X
X’  
600  
Y’  
600  
Y’  
Y
Unit: m/s

2  

Unit: m/s

2  

(Mounting pitch)  
Z
Z’  
Initial  
l
l
1
2
=2.54a  
=5.08a  
l
l
1
2
=5.08a  
=7.62a  
l
l
1
=7.62a  
=10.16a  
Y’  
2
(coil)  
Sample: G6C-2114P-US DC24V  
Number of Relays: 6 pcs  
Test conditions: Shock is applied in ±±, ±ꢀ, and ±ꢁ  
directions three times each with without energizing the  
Relays to check the number of malfunctions.  
Requirement: 100 m/s

2  

6

G6C  
PCB Power Relay  
■
Dimensions  
Flux Protection Model  
(Straight PCB)  
G6C-
@
117P (-FD) -US  
PCB Mounting Holes  
(Bottom View)  
Tolerance: ±0.1  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
20 max.  
(19.9)*  
15 max.  
(14.9)*  
1-pole  
2.54  
10 max.  
(9.9)*  
0.3  
Fo
u
r, 1.1-dia. holes  
1-pole  
2.54  
3.5  
1
3
4
−
0.5  
0.65<0.7>  
0.9<1.0>  
<0.4>  
0.9<1.0>  
10.16  
1.11  
10.16  
+
7.62  
* A
v
erage
v
al
u
e  
(2.4)  
8
Dimensions in pointed
b
rackets < > are  
for the Relay mo
u
nted to Socket (-P6C).  
10.16  
7.62  
(1.1)  
Flux Protection Model  
(Self-clinching PCB)  
G6C-
@
117C-US  
2-pole  
2.54  
Six, 1.1-dia. holes  
20 max.  
(19.9)*  
15 max.  
(14.9)*  
2-pole  
2.54  
1
3
6
4
5
−
10 max.  
0.3 (9.9)*  
+
3.2  
3.5  
0.9  
(2.4)  
8
(0.
8
)*  
(1.0)*  
0.65  
0.5  
0.9  
Note: Check carefully the coil  
polarity of the Relay.  
10.16  
1.11  
10.16  
10.16  
7.62  
G
6
C
7.62  
(1.1)  
* A
v
erage
v
al
u
e  
PCB Mounting Holes  
(Bottom View)  
Tolerance: ±0.1  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Fully Sealed Model  
(Straight PCB)  
G6C-
@
114P (-FD) -US  
20 max.  
(19.9)*  
15 max.  
(14.9)*  
1-pole  
2.54  
Fo
u
r, 1.1-dia. holes  
1-pole  
10 max.  
(9.9)*  
0.3  
2.54  
1
3
4
−
3.5  
0.5  
0.65<0.7>  
0.9<1.0>  
<0.4>  
0.9<1.0>  
10.16  
+
(2.4)  
8
1.11  
10.16  
7.62  
* A
v
erage
v
al
u
e  
10.16  
7.62  
(1.1)  
Dimensions in pointed
b
rackets < > are  
for the Relay mo
u
nted to Socket (-P6C).  
2-pole  
2.54  
Fully Sealed Model  
(Self-clinching PCB)  
G6C-
@
114C-US  
20 max.  
(19.9)*  
15 max.  
(14.9)*  
Six, 1.1-dia. holes  
2-pole  
2.54  
1
3
6
4
5
10 max.  
(9.9)*  
−
0.3  
3.2  
3.5  
+
(0.
8
)*  
(2.4)  
8
(1.0)*  
0.65  
0.9  
1.11  
0.5  
Note: Check carefully the coil  
polarity of the Relay.  
0.9  
10.16  
10.16  
7.62  
* A
v
erage
v
al
u
e  
10.16  
7.62  
(1.1)  
Note: Orientation marks are indicated as follows:  
7

G6C  
PCB Power Relay  
Flux Protective  
Single-winding Latching Model  
(Straight PCB)  
PCB Mounting Holes
 
Terminal Arrangement/  
(Bottom View)  
Internal Connections  
20 max.  
(19.9)*  
15 max.  
(14.9)*  
Tolerance: ±0.1  
(Bottom View)  
1-pole  
2.54  
G6CU-
@
117P (-FD) -US  
10 max.  
(9.9)*  
Fo
u
r, 1.1-dia. holes  
0.3  
1-pole  
2.54  
3.5  
1
3
4
−
+
0.5  
0.65<0.7>  
0.9<1.0>  
<0.4>  
0.9<1.0>  
S R  
10.16  
1.11  
10.16  
+ −  
7.62  
* A
v
erage
v
al
u
e  
(2.4)  
8
S: Set coil  
R: Reset coil  
Dimensions in pointed
b
rackets < >  
are for the Relay mo
u
nted to Socket (-P6C).  
10.16  
7.62  
(1.1)  
Flux Protective  
Single-winding Latching Model  
(Self-clinching PCB)  
2-pole  
2.54  
Six, 1.1-dia. holes  
2-pole  
20 max.  
(19.9)*  
15 max.  
(14.9)*  
2.54  
G6CU-
@
117C-US  
1
3
6
4
5
−
+
10max.  
(9.9)*  
0.3  
S R  
+
−
3.2  
3.5  
0.9  
(2.4)  
8
(0.
8
)*  
(1.0)*  
0.65  
0.5  
Note: Check carefully the coil  
polarity of the Relay.  
0.9  
10.16  
1.11  
10.16  
10.16  
7.62  
7.62  
(1.1)  
* A
v
erage
v
al
u
e  
G
6
C
PCB Mounting Holes  
(Bottom View)  
Tolerance: ±0.1  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Fully Sealed Model  
Single Latching Models  
(Straight PCB)  
20 max.  
(19.9)*  
15 max.  
(14.9)*  
1-pole  
2.54  
G6CU-
@
114P (-FD) -US  
10 max.  
0.3 (9.9)*  
Fo
u
r, 1.1-dia. holes  
1-pole  
2.54  
1
3
4
3.5  
−
+
0.5  
0.65<0.7>  
0.9<1.0>  
<0.4>  
S R  
0.9<1.0>  
10.16  
+
−
1.11  
10.16  
(2.4)  
8
7.62  
S: Set coil  
* A
v
erage
v
al
u
e  
10.16  
7.62  
R: Reset coil  
Dimensions in pointed
b
rackets < > are  
for the Relay mo
u
nted to Socket (-P6C).  
(1.1)  
Fully Sealed Model  
Single Latching Models  
(Self-clinching PCB)  
G6CU-
@
114C-US  
2-pole  
2.54  
Six, 1.1-dia. holes  
20 max.  
(19.9)*  
15 max.  
(14.9)*  
2-pole  
2.54  
1
3
6
4
5
−
+
10 max.  
0.3 (9.9)*  
S R  
+
−
3.2  
0.65  
3.5  
(2.4)  
8
(0.
8
)*  
(1.0)*  
0.9  
1.11  
0.5  
Note: Check carefully the coil  
polarity of the Relay.  
0.9  
10.16  
10.16  
10.16  
7.62  
7.62  
* A
v
erage
v
al
u
e  
(1.1)  
Note: Orientation marks are indicated as follows:  
8

G6C  
PCB Power Relay  
Flux Protective  
Double-winding Latching Model  
(Straight PCB)  
G6CK-
@
117P (-FD) -US  
PCB Mounting Holes  
(Bottom View)  
Tolerance: ±0.1  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
20 max.  
(19.9)*  
15 max.  
(14.9)*  
1-pole  
10 max.  
(9.9)*  
2.54  
0.3  
Six, 1.1-dia. holes  
1-pole  
2.54  
3.5  
0.9  
<1.0>  
1
2
7
3
4
−
−
0.65<0.7>  
0.5  
<0.4>  
0.9  
<1.0>  
0.9<1.0>  
S
R
10.16  
10.16  
* A
v
erage
v
al
u
e  
1.11  
+
+
7.62  
(2.4)  
8
S: Set coil  
R: Reset coil  
Dimensions in pointed
b
rackets < > are  
for the Relay mo
u
nted to Socket (-P6C).  
2.54  
7.62  
7.62  
(1.1)  
2-pole  
Flux Protective  
Double-winding Latching Model  
(Self-clinching PCB)  
2.54  
Eight, 1.1-dia. holes  
2-pole  
20 max.  
(19.9)*  
15 max.  
(14.9)*  
2.54  
1
2
7
3
6
4
5
G6CK-
@
117C-US  
−
−
10 max.  
(9.9)*  
S
R
0.3  
+
+
(2.4)  
8
3.2  
3.5  
(0.
8
)*  
(1.0)*  
0.9  
10.16  
* A
v
erage
v
al
u
e  
Note: Check carefully the coil  
polarity of the Relay.  
0.65  
0.9  
1.11  
0.5  
7.62  
7.62  
0.9  
10.16  
2.54  
(1.1)  
7.62  
G
6
C
Fully Sealed  
Double-winding Latching Model  
(Straight PCB)  
G6CK-
@
114P (-FD) -US  
PCB Mounting Holes  
(Bottom View)  
Tolerance: ±0.1  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
20 max.  
(19.9)*  
15 max.  
(14.9)*  
10 max.  
(9.9)*  
1-pole  
0.3  
2.54  
Six, 1.1-dia. holes  
1-pole  
3.5  
0.9  
<1.0>  
2.54  
1
2
7
3
4
0.65<0.7>  
0.5  
0.9  
<1.0>  
−
−
<0.4>  
0.9<1.0>  
10.16  
* A
v
erage
v
al
u
e  
S
R
1.11  
10.16  
7.62  
+
+
(2.4)  
8
Dimensions in pointed
b
rackets < > are  
for the Relay mo
u
nted to Socket (-P6C).  
S: Set coil  
7.62  
7.62  
R: Reset coil  
2.54  
(1.1)  
Fully Sealed  
Double-winding Latching Model  
(Self-clinching PCB)  
G6CK-
@
114C-US  
2-pole  
2.54  
Eight, 1.1-dia. holes  
20 max.  
(19.9)*  
15 max.  
(14.9)*  
2-pole  
2.54  
1
2
7
3
6
4
5
−
−
10 max.  
(9.9)*  
0.3  
S
R
+
+
3.2  
3.5  
(2.4)  
(0.
8
)*  
8
(1.0)*  
0.9  
10.16  
* A
v
erage
v
al
u
e  
0.65  
0.9  
1.11  
0.5  
Note: Check carefully the coil  
polarity of the Relay.  
0.9  
10.16  
7.62  
7.62  
7.62  
2.54  
(1.1)  
Note: Orientation marks are indicated as follows:  
9

G6C  
PCB Power Relay  
■
Connecting Sockets Dimensions  
Socket for single-winding latching/single-side a table Models  
P6C-06P  
PCB Mounting Holes  
(BOTTOM VIEW)  
T
o
lerance:  
23.2max.  
(23)*  
0.1 mm  
15max.  
(14.9)*  
Six, 1.1-dia. holes  
3.1  
2.54  
2.54  
(2.4)  
10.8max.  
(10.6)*  
7.5  
3.5  
10.16  
7.62  
(2.61)  
0.8  
0.4  
10.16  
7.62  
0.1  
* Average value  
10.16  
Socket for double-winding latching Models  
P6C-08P  
23.2max.  
(23)*  
PCB Mounting Holes  
(BOTTOM VIEW)  
0.1 mm  
T
o
lerance:  
15max.  
(14.9)*  
3.1  
G
6
C
Eight, 1.1-dia. holes  
2.54  
2.54  
(2.4)  
10.8max.  
(10.6)*  
7.5  
3.5  
0.8  
0.4  
7.62  
7.62  
(2.61)  
2.54  
7.62  
7.62  
2.54  
0.1  
* Average value  
10.16  
Note: Orientation marks are indicated as follows:  
10  

G6C  
PCB Power Relay  
■
Removal Tool  
■
Hold-down Clips  
P6B-Y1  
P6B-C2  
■
Approved Standards  
●
The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in  
this catalog.  
UL Recognized  
(File No. E41643)  
(File No. LR31928)  
CSA Certified  
Number of  
poles  
Number of test  
operations  
Model  
Coil ratings  
Contact ratings  
10 A, 250 VAC (General use) 80°C  
10 A, 30 VDC (Resistive) 80°C  
1/6 HP 125 VAC, 1/4 H
P
,
1
25 VAC 80°C  
1/3 HP 250 VAC, 1/4 H
P
,
2
50 VAC 80°C  
600 W, 120 VAC, (Tungsten) 80°C (excluding -FD Models)  
6,000  
6,000  
G
6
C
1
530 VA, 20 to 265 VAC Max 2A (Pilot Duty) 80°C  
43.2 VA, 30 VDC (Pilot Duty) 80°C  
30,000  
1,000 (-FD Models)  
12 LRA, 2.2 FLA, 30 VDC 80°C  
G6C (
 
)  
3 to 24 VDC  
8 A, 250 VAC (General use) 80°C  
8 A, 30 VDC (Resistive) 80°C  
1/6 HP 125 VAC, 1/4 H
P
,
1
25 VAC 80°C  
1/3 HP 250 VAC, 1/4 H
P
,
2
50 VAC 80°C  
600 W, 120 VAC, (Tungsten) 80°C (excluding -FD Models)  
6,000  
6,000  
2
530 VA, 20 to 265 VAC Max 2A (Pilot Duty) 80°C  
43.2 VA, 30 VDC (Pilot Duty) 80°C  
30,000  
1,000 (-FD Models)  
12 LRA, 2.2 FLA, 30 VDC 80°C  
EN/IEC, VDE Certified  
(Certificate No. 40014439)  
Number of  
Approved switching  
operations  
Model  
poles  
Coil ratings  
Contact ratings  
10 A, 250 VAC (cos
φ
= 1) 40°C  
5 A, 250 VAC (cos
φ
= 0.4) 40°C  
1
3, 5, 6, 12, 24 VDC  
G6C (
 
)  
20,000  
• Single-stable:  
3, 5, 6, 12, 24 VDC  
7 A, 250 VAC (cos
φ
= 1) 40°C  
3.5 A, 250 VAC (cos
φ
= 0.4) 40°C  
2
EN/IEC, TÜV Certified  
(Registration No. R50158249)  
Coil ratings  
Number of  
Approved switching  
operations  
Model  
poles  
Contact ratings  
10 A, 250 VAC (cos
φ
= 1) 40°C  
• Single-stable:  
3, 5, 6, 12, 24 VDC  
• Latching:  
1
2
5 A, 250 VAC (cos
φ
= 0.4) 40°C  
10 A, 30 VDC (L/R = 0 ms) 40°C  
G6C (
 
)  
20,000  
8 A, 250 VAC (cos
φ
= 1) 40°C  
3.5 A, 250 VAC (cos
φ
= 0.4) 40°C  
8 A, 30 VDC (L/R = 0 ms) 40°C  
3, 5, 6, 12, 24 VDC  
11  

G6C  
PCB Power Relay  
■
Precautions  
●
Please refer to “PCB Relays Common Precautions” for correct use.  
Correct Use  
●
Mounting  
●
Sockets  
●
Using SPDT contact of the  
SPS
T
–
NO+SPS
T
–
NC Relay  
• Do
 
not reverse the polarity of the coil  
(
+
,
−
).  
• Do
 
not construct a circuit so that  
overcurrent and burning occur if the  
NO, NC and SPDT contacts are short-  
circuited with the SPS
T
–
NO+SPS
T
–
NC  
Relay. Arcing may generate short-  
circuiting between contacts if there is  
short-circuiting because of conversion  
to the MBB contact caused by  
17 mm max. for sockets  
7.5 mm  
• When
 
mounting more than two relays  
side by side, keep the gap between  
Relays as shown below to ensure a  
good heat dissipation. It may result in  
malfunction if heat is not dissipated  
smoothly from the Rela
y
.  
• When
 
mounting the Rela
y
,
m
ake sure  
to insert the Relay terminals  
perpendicularly and correctly into the  
socket contact pin.  
• Hold-down
 
clips (for mounting and  
removal) are also available.  
asynchronous operation of the NO and  
NC contacts, the interval between the  
NO and NC contacts is small, or a  
large current is left open.  
2.54 mm ×  
3 pitch min.  
between  
terminals  
• The
 
P6C model has a flux-resistant  
construction. Do not wash it down with  
water.  
●
Other precautions  
2.54 mm × 2 pitch min. between terminals  
• The
 
max. carry current of sockets is 5A.  
• Not
 
applicable to the self-clinching type.  
• This
 
Relay is a Power Relay which is  
suitable for power load switching. Do  
not use the G6C for signal purposes  
such as micro load switching under  
10 mA.  
G
6
C
●
Double-winding Latching Circuit  
• It
 
is recommended to perform wiring of  
No.1 and No.2 of the negative (-)  
terminal as COM wiring, in order to  
improve the operation stability for  
Double-winding Latching.  
(
+
)  
+
−
8
+
−
7
R
2
S
1
COM  
Please check each region’s Terms & Conditions
b
y region
w
e
b
site.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Re
g
ional Contact  
Americas  
Europe  
https://
www
.components.omron.com/  
Asia-Pacific  
China  

https://ec

b
.omron.com.sg/  
https://
www
.ec
b
.omron.com.cn/  
Korea  
Japan  
https://
www
.omron-ec
b
.co.kr/  
https://
www
.omron.co.jp/ec
b
/  
© OMRO
N
Corporation 2007-201
8
All Rights Reser
v
ed.  
In the interest of prod
u
ct impro
v
ement, specifications are s
ub
ject to change
w
itho
u
t notice.  
Cat. No. K01
8
-E1-11  
031
8
(0207)(O)  
12