Omron-Electronics-G6E-134PL-ST-US-DC9

Part #Omron-Electronics-G6E-134PL-ST-US-DC9
Download 
Omron-Electronics-G6E-134PL-ST-US-DC9
G6E  
Subminiature, Sensitive SPDT  
Signal Switching Relay  
Low Signal Relay  
• High sensitivity: 98-mW (Rated power consumption:  
200mW) pickup coil power.  
• Impulse withstand voltage of 1,500V (10×160
μ
s) meets  
FCC requirements.  
• Stick packing employed in consideration of supporting  
automatic implementation.  
• Plastic-sealed model that allows automatic soldering.  
• New series of ultrasonically cleanable models is available.  
• Standard model conforms to UL/CSA standards.  
RoHS Compliant  
■
Model Number Legend  
G6E-
@
–
@
@@@@
–
@
–
@  
■
Application Examples  
• Telecommunication equipment  
• Office automation machines  
• Industrial equipment  
G
6
E
—
— — — — —  
—
—
1
2 3 4 5 6  
7
8
1. Relay
 
Function  
4. Enclosure
 
Rating  
7. Approved
 
Standards  
• Security equipment  
None: Single-side stable  
4: Fully sealed  
US: UL, CSA  
UL: FILE No.E41515  
U
K
:
:
Single-winding latching  
Double-winding latching  
5. Terminals
 
Shape  
(
)
CSA: FILE No.LR31928  
P: PCB terminals  
8. Special
 
Function  
2. Number
 
of poles/  
Contact Form  
6. Classification  
None : Standard  
None : Standard  
U
: For ultrasonically  
cleanable  
1: 1-pole/SPDT (1c)  
L
: Low sensitivity coil  
(400 mW)  
3. Contact
 
Type  
3: Bifurcated crossbar Ag  
(Au-Alloy) contact  
■
Ordering Information  
●
Standard Models (UL, CSA certified)  
Relay Function  
Single-side stable  
Standard Low-sensitivity  
Rated coil  
voltage  
Single-winding latching  
Standard  
Double-winding latching  
Standard Low-sensitivity  
Classification  
Minimum packing  
unit  
Rated coil  
voltage  
Rated coil  
Model  
Rated coil  
voltage  
Rated coil  
voltage  
Contact form  
SPDT (1c)  
Model  
Model  
Model  
Model  
voltage  
5 VDC  
6 VDC  
5 VDC  
6 VDC  
9 VDC  
12 VDC  
24 VDC  
−
5 VDC  
6 VDC  
5 VDC  
6 VDC  
9 VDC  
12 VDC  
24 VDC  
−
5 VDC  
6 VDC  
−
12 VDC  
24 VDC  
−
G6E  
-134PL-US  
G6EU  
-134P-US  
G6EK  
G6EK  
-134PL-US  
9 VDC  
9 VDC  
G6E  
-134P-US  
-134P-US  
25 pcs/tube  
12 VDC  
24 VDC  
48 VDC  
12 VDC  
24 VDC  
−
−
−
−
−
●
Models for Ultrasonically Cleanable  
Relay Function  
Single-side stable  
Single-winding latching  
Standard  
Double-winding latching  
Standard  
Classification  
Standard  
Rated coil  
voltage  
Low-sensitivity  
Minimum packing  
unit  
Rated coil  
voltage  
Rated coil  
Model  
Rated coil  
Model  
Contact form  
SPDT (1c)  
Model  
Model  
voltage  
voltage  
5 VDC  
6 VDC  
5 VDC  
5 VDC  
5 VDC  
−
−
−
−
−
−
G6E  
-134PL-US-U  
G6EU  
-134P-US-U  
G6EK  
-134P-US-U  
9 VDC  
G6E  
-134P-US-U  
25 pcs/tube  
12 VDC  
24 VDC  
48 VDC  
12 VDC  
24 VDC  
−
12 VDC  
12 VDC  
24 VDC  
−
−
−
−
−
−
Note: When ordering, add the rated coil voltage to the model number.  
Example: G6E-134P-US DC5  
Rated coil voltage  
However, the notation of the coil voltage on the product case as well as on the packing will be marked as
@@
VDC.  
1

G6E  
Low Signal Relay  
■
Ratings  
●
Coil: Single-side Stable  
Must operate
 
Must release  
Max.  
voltage  
(V)  
Rated  
current  
(mA)  
Coil  
resistance  
(
Ω
)  
Power  
consumption  
(mW)  
voltage  
(V)  
voltage  
(V)  
Classification Rated
 
voltage  
% of rated voltage  
5 VDC  
6 VDC  
9 VDC  
4ꢀ.ꢀ  
33.3  
22.2  
16.7  
8.3  
125  
18ꢀ  
19ꢀ%  
(at 23°C)  
4ꢀ5  
Approx. 2ꢀꢀ  
Approx. 4ꢀꢀ  
Approx. 4ꢀꢀ  
Standard  
7ꢀ% max.  
7ꢀ% max.  
1ꢀ% min.  
12 VDC  
24 VDC  
72ꢀ  
2,88ꢀ  
17ꢀ%  
(at 23°C)  
48 VDC  
8.3  
5,76ꢀ  
5 VDC  
6 VDC  
79.4  
66.6  
44.3  
33.3  
16.7  
63  
9ꢀ  
17ꢀ%  
(at 23°C)  
Low-sensitivity  
9 VDC  
2ꢀ3  
1ꢀ% min.  
12 VDC  
24 VDC  
36ꢀ  
1,44ꢀ  
●
Coil: Single-winding latching  
Must set voltage
 
Must reset voltage  
Max. voltage  
(V)  
Power consumption  
Rated current  
(mA)  
Coil resistance  
(V)  
(V)  
Contact type  
Rated voltage  
(
Ω
)  
% of rated voltage  
Set coil (mW)  
Reset coil (mW)  
5 VDC  
6 VDC  
4ꢀ.ꢀ  
33.3  
22.2  
16.7  
8.3  
125  
18ꢀ  
G
6
E
Bifurcated  
crossbar  
19ꢀ%  
(at 23°C)  
9 VDC  
4ꢀ5  
7ꢀ% max.  
7ꢀ% max.  
Approx. 2ꢀꢀ  
Approx. 2ꢀꢀ  
12 VDC  
24 VDC  
72ꢀ  
2,88ꢀ  
●
Coil: Double-winding latching  
Must set  
voltage  
(V)  
Must reset  
voltage  
(V)  
Max.  
voltage  
(V)  
Rated current (mA)  
Coil resistance (
Ω
)  
Power consumption  
Classification Rated
 
voltage  
Set coil  
(mW)  
Reset coil  
(mW)  
Set coil  
Reset coil  
Set coil  
Reset coil  
% of rated voltage  
7ꢀ% max.  
5 VDC  
6 VDC  
4ꢀ.ꢀ  
33.3  
22.2  
16.7  
8.3  
4ꢀ.ꢀ  
33.3  
22.2  
16.7  
8.3  
125  
18ꢀ  
4ꢀ5  
72ꢀ  
2,88ꢀ  
63  
125  
18ꢀ  
4ꢀ5  
72ꢀ  
2,88ꢀ  
63  
19ꢀ%  
(at 23°C)  
Standard  
9 VDC  
12 VDC  
24 VDC  
5 VDC  
7ꢀ% max.  
7ꢀ% max.  
Approx. 2ꢀꢀ
 
Approx. 2ꢀꢀ  
Approx. 4ꢀꢀ
 
Approx. 4ꢀꢀ  
79.4  
66.6  
44.3  
33.3  
16.7  
79.4  
66.6  
44.3  
33.3  
16.7  
6 VDC  
9ꢀ  
9ꢀ  
17ꢀ%  
(at 23°C)  
Low-sensitivity  
9 VDC  
2ꢀ3  
36ꢀ  
1,44ꢀ  
2ꢀ3  
36ꢀ  
1,44ꢀ  
7ꢀ% max.  
12 VDC  
24 VDC  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±1ꢀ%.  
2
.
O
perating characteristics are measured at a coil temperature of 23°C.  
3
.
T
he maximum voltage is the highest voltage that can be imposed on the relay coil.  
4
.
R
efer to the engineering data for relations between the ambient temperature and maximum coil voltage.  
●
Contacts  
Load  
Inductive load  
(cos
φ
= ꢀ.4; L/R = 7 ms)  
Resistive load  
Item  
Contact type  
Contact material  
Bifurcated crossbar  
Ag (Au-Alloy)  
ꢀ.4 A at 125 VAC;  
2 A at 3ꢀ VDC  
ꢀ.2 A at 125 VAC;  
1 A at 3ꢀ VDC  
Rated load  
Rated carry current  
3 A  
Max. switching voltage  
Max. switching current  
25ꢀ VAC, 22ꢀ VDC  
3 A  
2

G6E  
Low Signal Relay  
■
Characteristics (Including Models for Ultrasonically Cleanable)  
Item  
Relay Function  
Single-side Stable  
Single-winding Latching  
5ꢀ m
Ω
max.  
Double-winding Latching  
Contact resistance *1  
Operate (set) time  
Release (reset) time  
Min. set pulse width  
Min. reset pulse width  
Insulation resistance *2  
5 ms max.  
5 ms max.  
−
−
15 ms  
15 ms  
1,ꢀꢀꢀ M
Ω
min. (at 5ꢀꢀ VDC)  
Between coil and contacts  
2,5ꢀꢀ V (1ꢀ
×
16ꢀ
μ
s) (conforms to FCC part 68)  
1,5ꢀꢀ V (1ꢀ
×
16ꢀ
μ
s) (conforms to FCC part 68)  
1,5ꢀꢀ VAC, 5ꢀ/6ꢀ Hz for 1 min  
Impulse withstand  
voltage  
Between contacts of same polarity  
Between coil and contacts  
Between contacts of same polarity  
Destruction  
Malfunction  
Destruction  
Dielectric strength  
1,ꢀꢀꢀ VAC, 5ꢀ/6ꢀ Hz for 1 min  
1ꢀ to 55 to 1ꢀ Hz, 2.5 mm single amplitude (5 mm double amplitude)  
1ꢀ to 55 to 1ꢀ Hz, 1.65 mm single amplitude (3.3 mm double amplitude)  
1,ꢀꢀꢀ m/s

2  

Vibration  
resistance  
Shock resistance  
Malfunction  
3ꢀꢀ m/s

2  

Mechanical  
1ꢀꢀ,ꢀꢀꢀ,ꢀꢀꢀ operations min. (at 36,ꢀꢀꢀ operations/hr)  
1ꢀꢀ,ꢀꢀꢀ operations min. (ꢀ.4 A at 125 VAC resistive load; ꢀ.2 A at 125 VAC inductive load)  
(at 1,8ꢀꢀ operations/hr)  
5ꢀꢀ,ꢀꢀꢀ operations min. (2 A at 3ꢀ VDC resistive load; 1 A at 3ꢀ VDC inductive load)  
(at 1,8ꢀꢀ operations/hr)  
Durability  
Electrical  
2ꢀꢀ,ꢀꢀꢀ operations min. (3 A at 3ꢀ VDC resistive load) (at 1,8ꢀꢀ operations/hr)  
Failure rate (P level) (reference value) *3  
Ambient operating temperature  
Ambient operating humidity  
Weight  
1ꢀ
μ
A at 1ꢀ mVDC  
-4ꢀ°C to 7ꢀ°C (with no icing or condenstion)  
5% to 85%  
Approx. 2.7 g  
Note: The values here are initial values.  
*1. The
 
contact resistance was measured with 1 A at 5 VDC using a voltage-drop method.  
*2. The
 
insulation resistance was measured with a 5ꢀꢀ VDC Megger Tester applied to the same parts as those used for checking the dielectric strength.  
*3. This
 
value was measured at a switching frequency of 12ꢀ operations/min and the criterion of contact resistance is 5ꢀ
Ω
.  
This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions.  
G
6
E
■
Engineering Data  
●
Maximum Switching Power  
●
Durability  
●
Ambient Temperature vs.  
Maximum Coil Voltage  
280  
10  
10,000  
5,000  
3,000  
5
260  
DC resistive load  
G6E-134P-US  
G6EK-134P-US  
G6EU-134P-US  
3
2
240  
30 VDC inductive load  
(L/R = 7 ms)  
1,000  
220  
AC resistive load  
1
500  
300  
200  
180  
DC inductive load  
(L/R = 7 ms)  
0.5  
0.4  
30 VDC resistive load  
0.3  
0.2  
AC inductive load  
G6E-134PL-US  
160  
100  
φ
(cos =
 
0.4)  
125 VAC  
resistive  
load  
G6EK-134PL-US  
G6EU-134P-US  
Only at 48VDC  
0.1  
50  
140  
30  
0.05  
0.03  
120  
125 VAC  
inductive load  
(cos
φ
= 0.4)  
100  
0
10  
5
0.01  
0
3
5
10 20
 
30 50
 
100  
300 500 1,000  
0
0
.2 0.4  
1
2
3
4
-50  
-40  
-20  
0
20  
40  
60  
80 100  
Switching voltage (V)  
Switching current (A)  
Ambient temperature (°C)  
Note: The maximum coil voltage refers to the  
maximum value in a varying range of  
operating power voltage, not a continuous  
voltage.  
●
Ambient Temperature vs. Must  
Operate or Must Release Voltage  
100  
●
Shock Malfunction  
G6E-134P-US  
G6EK-134P-US  
De-energized  
Y
Y
Reset  
1,000  
1,000  
Coil is applied with  
130% of rated voltage  
Set  
Energized  
80  
X
1,000  
X
1,000  
Z
Z
Coil is applied with  
100% of rated voltage  
1,000  
1,000  
600  
Hot start voltage  
60  
Shock direction  
500  
Shock direction  
(max. value)  
X
X’  
X
X’  
Cold start voltage  
(max. value)  
Release voltage at  
Y
Voltage not applied to  
the coil and contacts  
Y
0
0
Z
Z
700  
Z’  
600  
Z’  
40  
hot start (min. value)  
Y’  
Y’  
1,000  
Z’  
1,000  
Z’  
Release voltage at  
X’  
1,000  
X’  
1,000  
cold start (min. value)  
Coil is applied with  
100% of rated voltage  
20  
1,000  
Y’  
1,000  
Y’  
Unit: m/s

2  

Unit: m/s

2  

Voltage not applied to the coil and contacts  
0
Sample: G6EK-134P-US
 
12 VDC  
Number of Relays: 20 pcs  
Sample: G6E-134P-US
 
24 VDC  
Number of Relays: 10 pcs  
-40  
-20  
0
20  
40  
60  
80  
100 120  
Ambient temperature (°C)  
Test Conditions:
 
Shock is applied in ±±, ±ꢁ, and ±Z directions three times each with and without energizing the  
Relays to check the number of contact malfunction.  
3

G6E  
●
Contact Reliability Test *1, *2  
Low Signal Relay  
●
Contact Reliability Test (70°C) *1, *2  
G6E-134P-US  
●
Mutual Magnetic Interference  
G6E-134P-US  
G6E-134P-US  
80  
80  
Must operate voltage  
Must release voltage  
max.  
Must operate voltage  
Must operate voltage  
70  
60  
50  
40  
30  
20  
10  
70  
60  
50  
40  
30  
20  
10  
2.54 mm  
max.  
min.  
Initial stage  
Test  
2.0  
1.0  
min.  
max.  
min.  
Sample: G6E-134P-US
 
24 VDC  
Number of Relays: 10 pcs  
Test conditions: Resistive load at  
10 VDC 0.01 mA  
5.08 mm  
Must  
release  
voltage  
0
−
1.0  
−
2.0  
Relays other  
than the  
testing  
models are  
de-energized  
Must release voltage  
Switching frequency: 1,800 operations/h  
max.  
Average value  
min.  
2.54 mm  
Sample: G6E-134P-US
 
24 VDC  
Number of Relays: 10 pcs  
Test conditions: Resistive load at 5 VDC 1 mA  
Initial stage  
Test  
100  
70  
50  
100  
70  
50  
2.0  
1.0  
max.  
Switching frequency: 120  
operations/min  
NO contact
 
NC contact  
30 50
 
100  
max.  
5.08 mm  
30  
30  
NO contact
 
NC contact  
max.  
0
−
1.0  
−
2.0  
min.  
min.  
min.  
Relays other  
than the  
testing  
models are  
de-energized  
10  
10  
300 500 1,000
 
3,000 5,000  
0.1 0.
3
0
.5  
1
3
5
10  
30 50
 
100 300
 
500  
Rotation (×10

4

turns)  
Average value  
Operating frequency (×10

4

operations)  
●
High-frequency Characteristics  
●
High-frequency Characteristics  
(Isolation) *1, *3  
(Insertion Loss) *1, *3  
G6E-134P-US  
(Average value (initial))  
G6E-134P-US  
(Average value (initial))  
0
0
Sample: G6E-134P  
Number of Relays: 5 pcs  
Sample: G6E-134P  
Number of Relays: 5 pcs  
NC contact  
20  
40  
60  
NC contact  
1
2
G
6
E
NO contact  
NO contact  
3
4
80  
100  
1
10  
100  
1,000  
1
10  
100  
1,000  
Frequency (MHz)  
Frequency (MHz)  
●
Must Operate and Must Release  
Time Distribution *1  
G6E-134P-US  
G6E-134PL-US  
G6E-134P-US 48 VDC  
50  
100  
50  
Sample: G6E-134P-US  
Must operate time  
Sample: G6E-134PL-US  
Sample: G6E-134P-US  
48 VDC  
Must operate time  
Must release time  
Must operate time  
Must release time  
Number of Relays: 100 pcs  
Number of Relays: 100 pcs  
Test conditions:
100% of  
80
coil voltage applied  
Test conditions: 100% of  
40
coil voltage applied  
Number of Relays: 100 pcs  
40 Test
 
conditions:
100% of  
coil voltage applied  
Must release time  
100  
30  
20  
10  
60  
30  
20  
10  
40  
20  
0
1.0 1.2 1.4 1.6 1.8 2.1 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6  
Time (ms)  
0
1
2
3
4
5
0
1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8
 
3.0  
Time (ms)  
Time (ms)  
●
Distribution of Bounce Time *1  
G6E-134P-US  
G6E-134PL-US  
50  
50  
Operating bounce time  
Release bounce time  
Sample:  
G6E-134P-US  
12 VDC  
Operating bounce time  
Release bounce time  
Sample:  
G6E-134PL-US  
12 VDC  
*1. The
 
tests were conducted at an ambient  
temperature of 23°C.  
Number of Relays:  
50 pcs  
Number of Relays:  
50 pcs  
40  
30  
20  
10  
40  
30  
20  
10  
*2. The
 
contact resistance data are periodically  
measured reference values and are not  
values from each monitoring operation.  
Contact resistance values will vary  
according to the switching frequency and  
operating environment, so be sure to check  
operation under the actual operating  
conditions before use.  
*3. High-frequency
 
characteristics depend on  
the PCB to which the Relay is mounted.  
Always check these characteristics,  
including durability, in the actual machine  
before use.  
0
0.1  
0.2  
0.3  
0.4  
Time (ms)  
0
0.3  
0.6  
0.9  
1.2  
1.5  
1.8 2.1  
Time (ms)  
4

G6E  
Low Signal Relay  
■
Dimensions  
Single-side stable  
G6E-134P-US  
G6E-134PL-US  
G6E-134P-US-U  
G6E-134PL-US-U  
PCB Mounting Holes  
(Bottom View)  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Tolerance: ±ꢀ.1  
2.54  
Fi
v
e, 1.ꢀ dia. holes  
16max.  
(15.9)*  
1ꢀmax.  
(9.9)*  
(1.19)  
2.54  
1
+  
−
6  
8
max.  
(7.9)*  
ꢀ.3  
7.62  
12 1ꢀ  
7
3.5  
N
ote: Be s
u
re to confirm  
coil polarity.  
ꢀ.6  
1.6  
ꢀ.25  
5.ꢀ
8  
(1.65)  
7.62  
5.ꢀ
8
7.62  
7.62  
* A
v
erage
v
al
u
e  
N
ote: Orientation marks are indicated as follo
w
s:  
Single-winding latching  
G6EU-134P-US  
G6EU-134P-US-U  
PCB Mounting Holes  
(Bottom View)  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Tolerance: ±ꢀ.1  
2.54  
Fi
v
e, 1.ꢀ dia. holes  
16max.  
(15.9)*  
1ꢀmax.  
(9.9)*  
(1.19)  
+
1  
S
−
6  
+
2.54  
−
R
8
max.  
(7.9)*  
ꢀ.3  
7.62  
12 1ꢀ  
7
N
ote: Be s
u
re to confirm  
3.5  
coil polarity.  
ꢀ.6  
1.6  
ꢀ.25  
5.ꢀ
8  
(1.65)  
7.62  
5.ꢀ
8
7.62  
7.62  
* A
v
erage
v
al
u
e  
G
6
E
N
ote: Orientation marks are indicated as follo
w
s:  
Double-winding latching  
G6EK-134P-US  
G6EK-134PL-US  
PCB Mounting Holes  
(Bottom View)  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Tolerance: ±ꢀ.1  
G6EK-134P-US-U  
2.54  
Six, 1.ꢀ dia. holes  
(1.19)  
16max.  
(15.9)*  
1ꢀmax.  
(9.9)*  
+
1  
S
−
6
+
3
R
2.54  
8
max.  
(7.9)*  
ꢀ.3  
7.62  
12 1ꢀ  
7
N
ote: Be s
u
re to confirm coil  
polarity. The model  
3.5  
G6EK-134P-1-US has positi
v
e  
(+) terminal #3 and negati
v
e  
(-) terminals #1 and #6.  
ꢀ.6  
1.6  
ꢀ.25  
5.ꢀ
8  
(1.65)  
7.62  
5.ꢀ
8
7.62  
7.62  
* A
v
erage
v
al
u
e  
N
ote: Orientation marks are indicated as follo
w
s:  
5

G6E  
Low Signal Relay  
■
Approved Standards  
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm the  
values before use.  
UL recognized:  
(File No. E41515)  
CSA certified:
 
(File No. LR31928)  
Contact  
form  
Number of test  
operations  
Model  
Coil ratings  
Contact ratings  
0.2 A, 250 VAC  
0.6 A, 125 VAC  
2 A, 30 VDC  
SPDT  
(1c)  
5 to 48  
VDC  
G6E( )-134P( )US  
6,000  
0.6 A, 125 VDC  
■
Precautions  
●
Please refer to “PCB Relays Common Precautions” for correct use.  
Correct Use  
●
Long-term Continuously ON  
●
Wiring  
●
Relay Handling  
Contacts  
• Refer to the following diagram when  
wiring to switch a DC load. The  
difference in polarity applied to the  
contacts will affect the endurance of  
the Relay due to the amount of contact  
movement. To extend the endurance  
characteristics beyond the  
• When washing the product after  
soldering the Relay to a PCB, use a  
water-based solvent or alcohol-based  
solvent, and keep the solvent  
temperature to less than 40°C. Do not  
put the Relay in a cold cleaning bath  
immediately after soldering.  
• Using the Relay in a circuit where the  
Relay will be ON continuously for long  
periods (without switching) can lead to  
unstable contacts because the heat  
generated by the coil itself will affect  
the insulation, causing a film to  
develop on the contact surfaces. We  
recommend using a latching relay  
(magnetic-holding relay) in this kind of  
circuit. If a single-side stable model  
must be used in this kind of circuit, we  
recommend using a fail-safe circuit  
design that provides protection against  
contact failure or coil burnout.  
●
Mounting  
G
6
E
performance ratings, wire the common  
(pin 7) terminal to the positive (+) side.  
7
12  
10  
+
−
Load  
Load  
Wiring Diagram  
●
Ultrasonic Cleaning  
• Do not use ultrasonic cleaning on  
standard relay models. Doing so may  
result in resonance, coil burnout, and  
contact adhesion within the Relay.  
Use a model designed for ultrasonic  
cleaning if ultrasonic cleaning is  
required.  
• Do not reverse the polarity of the coil  
(
+
,
−
).  
• Provide sufficient space between  
Relays when mounting two or more on  
the same PCB, as shown in the  
following diagram.  
Close  
mounting  
Distance between terminals:  
2.54 × 2 (pitch) max.  
•
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
•
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Cat. No. K024-E1-11  
0617(0207)(O)  
6