Omron-Electronics-G6K-2F-RF-V-DC5

Part #Omron-Electronics-G6K-2F-RF-V-DC5
Download 
Omron-Electronics-G6K-2F-RF-V-DC5
G6K-2F-RF-V  
Surface-mounting High-frequency Relay  
8-GHz Band Miniature DPDT  
High Frequency Relay for High-speed  
Differential Transmission Signal  
Switching  
• High-frequency characteristics (insertion loss 3 dB or less at 8 GHz)  
• Miniaturized to 11.7 × 7.9 × 7.1 mm (L × W × H).  
• Rated power consumption of 100 mW with high sensitivity  
RoHS Compliant  
■
Model Number Legend  
G6K-

—

2
F

—

–
RF-V  
Application Examples  
• Semiconductor test equipment  
• Test&measurement
 
equipment  
• Communication equipment  
—
—
1 2
 
3 4  
1. Number
 
of poles/  
Contact Form  
2: 2-pole/ DPDT (2c)  
3. Special
 
Function 1  
RF: High-frequency compatible  
■
Standard type specifications  
G
6
K
2
F
4. Special
 
Function 2  
V: 8-GHz
 
band  
Contact type: Bifurcated crossbar  
Ag (Surface Au alloy)  
2. Terminal
 
Shape  
F: Outside-L
 
surface mounting  
terminals  
High-speed differential trans-  
mission compatible type  
R
F
Note. We have a lineup of G6K (U)-2F(P)-RF(-S,-T) products for 1-GHz/3-GHz band high-frequency signal applications.  
V
■
Ordering Information  
Relay Function  
Single-side stable  
Enclosure rating  
Fully sealed  
Contact form  
DPDT (2c)  
Model  
Rated coil voltage  
3, 4.5, 5, 12 VDC  
Minimum packing unit  
40 pcs/tube  
G6K-2F-RF-V  
Note 1. When ordering, add the rated coil voltage to the model number.  
Example: G6K-2F-RF-V DC5  
Rated coil voltage  
However, the notation of the coil voltage on the product case as well as on the packing will be marked as
@@
VDC.  
■
Ratings  
●
Contacts  
●
High-frequency Characteristics
*
1  
Item  
Load  
Resistive load  
125 VAC, 0.3 A  
30 VDC, 1 A  
10 VDC, 10 mA  
8 GHz, 1 W
*  
1 A  
125 VAC or 60 VDC  
1A  
Item  
Frequency  
8GHz  
3 dB max.  
Insertion loss  
Isolation  
Differential  
transmission  
characteristics  
Rated load  
15 dB min.  
Return loss (V.SWR)  
Insertion loss  
5 dB min. (3.57 max.)  
4 dB max.  
Rated carry current  
Max. switching voltage  
Max. switching current  
Between contacts of  
the same polarity  
15 dB min.  
15 dB min.  
Single-ended  
characteristics  
(reference value)  
*
This value is for a V.SWR of 1.2 max. at the load.  
Isolation  
Between contacts of  
different polarity  
Return loss (V.SWR)  
5 dB min. (3.57 max.)  
1 W
*
2  
Maximum carry power  
Maximum switching power  
1 W
*
2  
Note 1. The impedance of the measurement system is 50
Ω
. (Differential im-  
pedance is 100
Ω
.)  
Note 2. The above values are initial values.  
*1.
Contact your OMRON representative if the Relay will be used in an  
application that requires high repeatability in high-frequency  
characteristics.  
*2.
These values are for a V.SWR of 1.2 max. at the load.  
1

G6K-2F-RF-V  
●
Coil: Single  
Surface-mounting High-frequency Relay  
Must operate voltage
 
Must release voltage
 
Maximum voltage  
Power consumption  
Item  
Rated current  
Coil resistance  
(V)  
(V)  
(V)  
(mA)  
(
Ω
)  
(mW)  
Rated voltage  
% of rated voltage  
3 VDC  
33.0  
23.2  
21.1  
9.1  
91  
194  
4.5 VDC  
5 VDC  
80% max.  
10% min.  
150%  
Approx. 100  
237  
12 VDC  
1,315  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.  
Note 2. The operating characteristics are measured at a coil temperature of 23°C.  
Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.  
■
Characteristics  
Contact resistance
*
1  
Operating time
*
2  
Release time
*
2  
100 m
Ω
max.  
3 ms max. (approx. 1.4 ms)  
3 ms max. (approx. 0.7 ms)  
500 M
Ω
min. (at 500 VDC)  
Insulation resistance
*
3  
Between coil and  
contacts  
Between contacts of  
different polarity  
Between contacts of the  
same polarity  
350 VAC, 50/60 Hz for 1 min  
350 VAC, 50/60 Hz for 1 min  
350 VAC, 50/60 Hz for 1 min  
350 VAC, 50/60 Hz for 1 min  
Dielectric  
strength  
Between ground and  
coil/contacts  
Destruction  
Malfunction  
Destruction  
Malfunction  
Mechanical  
10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude)  
10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude)  
1,000 m/s

2  

750 m/s

2  

50,000,000 operations min. (at a switching frequency of 36,000 operations/hour)  
1,000,000 operations min. (10 VDC, 10 mA, at a switching frequency of 1,800 operations/hour)  
100,000 operations min. (Other rated load, at a switching frequency of 1,800 operations/hour)  
-40°C to 70°C (with no icing or condensation)  
Vibration  
resistance  
G
6
Shock  
resistance  
K
2
F
R
F
Durability  
Electrical  
Ambient operating temperature  
Ambient operating humidity  
Weight  
V
5% to 85%  
Approx. 1.16 g  
Note. The above values are initial values.  
*1.
The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.  
*2.
Values in parentheses are actual values.  
*3.
The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength.  
2

G6K-2F-RF-V  
Surface-mounting High-frequency Relay  
■
Engineering Data  
●
High-frequency characteristics (differential transmission characteristics)  
Insertion loss  
Isolation  
Return loss, V.SWR  
<Typical (Initial)>  
<Typical (Initial)>  
<Typical (Initial)>  
0
0
0
5
N.O.  
N.C.  
Sample: G6K-2F-RF-V  
Sample: G6K-2F-RF-V  
1
2
5
10  
15  
20  
25  
4.5  
10  
20  
30  
40  
4
Return loss  
3
4
3.5  
3
5
6
V.SWR  
2.5  
2
7
30  
35  
N.O.  
N.C.  
8
N.O.  
N.C.  
50  
60  
1.5  
1
9
Sample: G6K-2F-RF-V  
40  
10  
0
1
2
3
4
5
6
7
8
9
10 11 12  
0
1
2
3
4
5
6
7
8
9
10 11
 
12  
0
1
2
3
4
5
6
7
8
9
10 11
 
12  
Frequency (GHz)  
Frequency (GHz)  
Frequency (GHz)  
●
High-frequency characteristics (single-ended characteristics)  
Insertion loss  
Isolation  
Return loss, V.SWR  
<Typical (Initial)>  
<Typical (Initial)>  
<Typical (Initial)>  
0
0
0
5
N.O.  
N.C.  
Sample: G6K-2F-RF-V  
Sample: G6K-2F-RF-V  
1
2
5
10  
15  
20  
25  
4.5  
10  
20  
30  
40  
50  
60  
G
6
K
2
F
R
F
4
Return loss  
3
4
3.5  
3
5
6
7
V.SWR  
2.5  
2
V
30  
35  
N.O.  
N.C.  
8
N.O.  
N.C.  
1.5  
1
9
Sample: G6K-2F-RF-V  
10  
40  
0
1
2
3
4
5
6
7
8
9
10 11
 
12  
0
1
2
3
4
5
6
7
8
9
10 11 12  
0
1
2
3
4
5
6
7
8
9
10 11
 
12  
Frequency (GHz)  
Frequency (GHz)  
Frequency (GHz)  
Note 1. The high-frequency characteristics depend on the mounting board. Be sure to check operation including durability in actual equipment before use.  
Note 2. Ambient temperature condition: 23°C.  
Note 3. The impedance of the measurement system is 50
Ω
. (Differential impedance is 100
Ω
.)  
Note 4. S parameter (Touchstone format) data used for circuit simulation is available. Please inquire.  
3

G6K-2F-RF-V
Surface-mounting High-frequency Relay  
●
High-frequency characteristics (Signal Integrity, differential transmission)  
at 8.1 Gbps  
at 10 Gbps  
at 12.5 Gbps  
N.O. Contact  
N.O. Contact  
N.O. Contact  
<Typical (Initial)>  
<Typical (Initial)>  
<Typical (Initial)>  
300  
250  
200  
150  
100  
50  
300  
250  
200  
150  
100  
50  
300  
250  
200  
150  
100  
50  
0
0
0
-50  
-100  
-50  
-100  
-50  
-100  
0
50  
100  
150  
200  
Time (ps)  
250  
0
20 40 60 80
 
100 120
 
140 160 180
 
200  
Time (ps)  
0
20  
40  
60  
80  
100 120 140
 
160  
Time (ps)  
Eye Height  
173 mV  
Eye Width  
121.0 ps  
Jitter P-P  
2.5 ps  
Eye Height  
177 mV  
Eye Width  
96.5 ps  
Jitter P-P  
3.5 ps  
Eye Height  
147 mV  
Eye Width  
75.2 ps  
Jitter P-P  
4.8 ps  
N.C. Contact  
N.C. Contact  
N.C. Contact  
<Typical (Initial)>  
<Typical (Initial)>  
<Typical (Initial)>  
300  
300  
300  
250  
200  
150  
100  
50  
250  
200  
150  
100  
50  
250  
200  
150  
100  
50  
G
6
K
2
F
R
F
V
0
0
0
-50  
-100  
-50  
-100  
-50  
-100  
0
50  
100  
150  
200  
Time (ps)  
250  
0
20  
40  
60  
80  
100 120 140
 
160  
Time (ps)  
0
20 40 60 80
 
100 120
 
140 160 180
 
200  
Time (ps)  
Eye Height  
166 mV  
Eye Width  
116.0 ps  
Jitter P-P  
7.4 ps  
Eye Height  
172 mV  
Eye Width  
94.5 ps  
Jitter P-P  
5.5 ps  
Eye Height  
137 mV  
Eye Width  
74.4 ps  
Jitter P-P  
5.6 ps  
Conditions  
• 2

11

-1 PRBS signal  
• Input differential voltage 200 mV  
• Rise time 25 ps @10 – 90%  
Note 1. Ambient temperature condition: 23°C.  
Note 2. The impedance of the measurement system is 50
Ω
. (Differential impedance is 100
Ω
.)  
Note 3. This data includes loss due to the test board.  
●
Propagation delay time  
Conditions  
Item  
Propagation delay time (ps)  
(typical value)  
Rise time 25 ps @10 – 90%  
N.O. Contact  
N.C. Contact  
107.5  
115.0  
90%  
10%  
Relay input  
waveform  
Voltage  
50%  
Note 1. Ambient temperature condition: 23°C.  
Note 2. The impedance of the measurement system is 50
Ω
. (Differential im-  
pedance is 100
Ω
.)  
Time  
Relay output  
waveform  
50%  
Time  
Propagation delay time  
Voltage  
4

G6K-2F-RF-V  
Surface-mounting High-frequency Relay  
■
Dimensions  
(Unit: mm)  
Mounting Dimensions (Top View)  
Terminal Arrangement/  
Internal Connections  
TOP VIEW  
G6K-2F-RF-V  
Tolerance: ±0.1 mm  
11.7 0.2  
7.9 0.2  
Orientation mark  
10.16  
8.89  
7.1  
8
7
6
5
7.62  
6.35  
5.08  
3.81  
0.15  
−
1.27  
2.54  
0.4 0.1  
(0.76)  
+
(1.68)  
2.54  
1.27  
(5.08)  
3.81  
5.08  
6.35  
1
2
3
4
8.3 0.2  
7.62  
8.89  
10.16  
(9.2)  
Note. Check carefully the coil  
polarity of the Relay.  
4.24  
Note 1. Each value has a tolerance of ±0.3 mm.  
Note 2. The coplanarity of the terminals is 0.15 mm max.  
0.7  
Note 3. The dimensions of the printed circuit board work drawing are a recommended example that take sol-  
dering into consideration. Frequency characteristics vary depending on the band dimensions, so check  
the effect on high-frequency characteristics using a test board before use.  
■
Package specifications  
Tube Packing  
G6K-2F-RF-V in tube packing are arranged so that the orienta-  
tion mark of each Relay in on the left side.  
Be sure not to make mistakes in Relay orientation when mount-  
ing the Relay to the PCB.  
G
6
K
2
F
Stopper  
(gray)  
Orientation of Relays  
Stopper  
(green)  
R
F
V
Tube length: 520 mm (stopper not included)  
No. of Relays per tube: 40 pcs  
5

G6K-2F-RF-V  
Surface-mounting High-frequency Relay  
■
G6K-2F-RF-V Recommended Soldering Method  
●
Recommended Conditions for IRS Method (Surface-mounting Terminals)  
• The thickness of cream solder to be applied should be  
(1) IRS Method (Mounting Solder: Lead)  
between 200 and 250
μ
m and the land pattern should be  
based on OMRON’s recommended PCB pattern.  
• To maintain the correct soldering joint shown in the following  
diagram, we recommend applying solder with the soldering  
conditions shown on the left.  
Soldering  
220~  
245  
Correct Soldering  
Incorrect Soldering  
180~  
200  
Relay  
T
e
rminal  
Land  
PCB  
Preheating  
150  
Heel fillet is  
formed  
Solder  
Insufficient amount of solder  
Excessive amount of solder  
Check the soldering in the actual mounting conditions before use.  
90~120  
20~30  
Time (s)  
(The temperature profile indicates the temperature on the circuit board surface.)  
(2) IRS Method (Mounting Solder: Lead-free)  
Case top panel (peak):  
255°C max.  
Soldering  
G
6
K
250 max.  
230  
180  
2
F
R
F
Preheating  
150  
V
Relay terminal  
section  
120 max.  
30 max.  
Time (s)  
(The temperature profile indicates the temperature on the PCB.)  
6

G6K-2F-RF-V  
Surface-mounting High-frequency Relay  
■
Safety Precautions  
●
For general precautions on PCB Relays, refer to the precautions provided in General Information of the Relay Product  
Data Book.  
Correct Use  
●
Relay Handling  
●
Coating  
• Use the Relay as soon as possible after opening the  
moistureproof package. (As a guideline, use the Relay within  
one week at 30°C or less and 60% RH or less.) If the Relay is  
left for a long time after opening the moisture-proof package,  
the appearance may suffer and seal failure may occur after the  
solder mounting process. To store the Relay after opening the  
moisture-proof package, place it into the original package and  
seal the package with adhesive tape.  
• When washing the product after soldering the Relay to a PCB,  
use a water-based solvent or alcohol-based solvent and keep  
the solvent temperature to less than 40°C. Do not put the  
Relay in a cold cleaning bath immediately after soldering.  
• Do not use silicone coating to coat the Relay when it is  
mounted to the PCB. Do not wash the PCB after the Relay is  
mounted using detergent containing silicone. Otherwise, the  
detergent may remain on the surface of the Relay.  
●
Repeatability  
• Contact your OMRON representative if the Relay will be used  
in an application that requires high repeatability in high-  
frequency characteristics and contact resistance.  
●
Environmental Conditions for Usage, Storage, and  
Transport  
• Avoid direct sunlight when using, storing, or transporting the  
Relay and maintain normal temperature, humidity, and  
pressure conditions.  
●
Long-term, Continuous ON Contacts  
G
6
• Using the Relay in a circuit where the Relay will be ON continuously  
for long periods (rather than switching) can lead to unstable contacts  
because the heat generated by the coil itself will affect the insulation  
and can cause a film to develop on the contact surfaces. We  
recommend using a latching relay (magnetic-holding relay) in this  
kind of circuit. If a single-side stable model must be used in this kind  
of circuit, we recommend adding fail-safe circuits in case the contact  
fails or the coil burns out.  
K
2
F
R
F
V
●
Claw Securing Force During Automatic Mounting  
• During automatic insertion of Relays, be sure to set the  
securing force of each claw to the following so that the Relay’s  
characteristics will be maintained.  
C
B
Direction A: 1.96 N max.  
Direction B: 4.90 N max.  
Direction C: 1.96 N max.  
•
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
•
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Cat. No. K290-E1-02  
0917(0317)(O)  
7