Omron-Electronics-G6RL-1-DC12

Part #Omron-Electronics-G6RL-1-DC12
Download 
Omron-Electronics-G6RL-1-DC12
G6RL  
PCB Power Relay  
Low-profile 12.3 mm height power  
relay with maximum switching of 10A  
• Low profile: 12.3 mm in height  
• Max. switching capacity: 2,500 VA (NO)  
• Dielectric strength: 5 kV  
• Clearance and creepage distance: 10 mm.  
• Models with high shock resistance (250 m/s

2

) are available.  
• Models for P1 load (2 x 200 W lamps parallel to ignition transformer) are  
available.  
RoHS Compliant  
■
Model Number Legend  
G6RL-
@ @ @
–
@
–
@  
■
Application Examples  
• Boilers  
1
2 3  
4
5
• PLCs  
1. Number of Poles  
1: 1-pole  
4. Contact material  
G
6
R
L
• I/O ports  
None: Standard
 
(Ag-alloy, Cd free)  
• Timers  
ASI:  
AgSnIn  
• Temperature controllers  
2. Contact Form  
None: SPDT
 
(1c)  
5. Special Functions  
A:  
SPST-NO (1a)  
PL:  
P1 load  
3. Enclosure rating  
None: Flux
 
protection  
4:  
Fully sealed  
■
Ordering Information  
Classification  
Standard  
Terminal Shape  
Contact form  
Enclosure rating  
Model  
G6RL-1A  
G6RL-1A-ASI  
Rated coil voltage  
Minimum packing unit  
Flux protection  
Fully sealed  
3 VDC  
5 VDC  
6 VDC  
12 VDC  
24 VDC  
48 VDC  
SPST-NO (1a)  
P1 Load  
Standard  
G6RL-1A-ASI-PL  
G6RL-1A4-ASI  
PCB terminals  
100 pcs/tray  
G6RL-1  
G6RL-1-ASI  
Flux protection  
SPDT (1c)  
P1 Load  
Standard  
G6RL-1-ASI-PL  
G6RL-14-ASI  
Fully sealed  
Note.
When ordering, add the rated coil voltage to the model number
.  
Example: G6RL-1A DC3  
Rated coil voltage  
However, the notation
 
of the coil voltage
 
on the product case as well as on the packing will be marked as
@@
VDC.  
■
Ratings  
●
Coil  
Standard, P1 Load (-PL type)  
Must operate voltage
 
Must release voltage  
Max. voltage  
(V)  
Rated Voltage  
(VDC)  
Rated current  
Coil resistance  
Power consumption  
(mW)  
(V)  
(V)  
(mA)  
(
Ω
)  
% of rated voltage  
3
5
73.3  
44.0  
36.7  
18.3  
9.2  
40  
113  
6
Approx. 220  
Approx. 240  
163  
150%  
(at 23°C)  
70% max.  
10% min.  
12  
24  
48  
654  
2618  
9600  
5.0  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
 
10%.  
Note 2. The operating characteristics are measured at a coil temperature of 23°C.  
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.  
1

G6RL  
●
Contacts  
PCB Power Relay  
Load  
Resistive load  
Contacts type  
Single  
Contacts material  
Ag-alloy (Cd free)  
10 A at 250 VAC, (NO) resistive load  
8 A at 250 VAC, resistive load  
5 A at 30 VDC, resistive load  
Rated load *  
Rated carry current  
10 A  
Max. switching current  
NO: 10 A, NC: 8 A  
*
G6RL-1(A), G6RL-1(A)4-ASI: 8 A 250 VAC, resistive load; 5 A 24 VDC resistive load.  
■
Characteristics  
Contact resistance *1  
Operate time  
100 m
Ω
max.  
10 ms max.  
5 ms max.  
Release time  
Insulation resistance *2  
1,000 M
Ω
min.  
Between coil and contacts  
5,000 VAC, 50/60 Hz for 1 min  
Dielectric strength  
Between contacts of the same polarity
 
1,000 VAC, 50/60 Hz for 1 min  
Impulse withstand voltage
 
Between coil and contacts  
10kV (1.2
×
50
μ
s)  
Insulation distance  
Between coil and contacts  
Destruction  
Clearance: 10 mm, Creepage: 10 mm  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
Vibration resistance  
10 to 55 to 10 Hz, 0.825 mm single amplitude (1.65 mm double amplitude) when energized  
10 to 55 to 10 Hz, 0.4 mm single amplitude (0.8 mm double amplitude) when de-energized.  
Malfunction  
Destruction  
Malfunction  
Mechanical  
1,000 m/s

2  

NO: 200 m/s

2

, NC: 50 m/s

2  

Shock resistance  
G
6
R
L
10,000,000 operations min. (at 18,000 operations/h)  
G6RL-1(A)  
50,000 operations min. (NO) at 250 VAC, 8A (resistive load)  
50,000 operations min. (NC) at 250 VAC, 8A (resistive load)  
50,000 operations min. at 24 VDC, 5A (resistive load)  
(at 600 operations/h)  
G6RL-1(A)-ASI-(PL)  
100,000 operations min. (NO) at 250 VAC, 10A (resistive load)  
100,000 operations min. at 250 VAC, 8A (resistive load)  
50,000 operations min. at 30 VDC, 5A (resistive load)  
(at 1,800 operations/h)  
Endurance  
Electrical  
G6RL-1(A)4-ASI  
50,000 operations min.
 
(NO) at 250 VAC, 8A (resistive load)  
50,000 operations min. (NC) at 250 VAC, 8A (resistive load)  
50,000 operations min. at 24 VDC, 5A (resistive load)  
(at 1,800 operations/h)  
Failure rate (P level) (reference value) *3  
Ambient operating temperature  
Ambient operating humidity  
Weight  
10 mA at 5 VDC  
-40°C to 85°C (with no icing or condensation)  
5% to 85%  
Approx. 7.8 g  
Note. The given values are initial values.  
*1. Measurement
 
conditions: 5 VDC, 1 A, voltage drop method.  
*2. Measurement
 
conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.  
*3. This
 
value was measured at a switching frequency of 120 operations/min.  
2

G6RL  
■
Engineering Data  
PCB Power Relay  
G6RL-1(A)(4)-(ASI)-(PL)  
G6RL-1(A)(4)-(ASI)-(PL)  
G6RL-1(A)  
●
Ambient Temperature vs. Maximum  
●
Maximum Switching Capacity  
●
Durability  
Coil Voltage  
200  
1,000  
100  
250 VAC inductive load  
50  
AC resistive load (N.O.)  
AC resistive load (N.C.)  
180  
500  
300  
(cos
φ
= 0.4)  
G6RL-1(220 mW)  
DC resistive load  
160  
150  
140  
10  
5
250 VAC resistive load (N.O.)  
100  
50  
120  
100  
24 VDC resistive load  
1
30  
0.5  
80  
60  
10  
0.1  
0
2
4
6
8
10  
–
40 20
 
23 30  
40  
50  
60  
70  
80  
90 100  
1
3
5
10  
30 50
 
100  
300 500 1,000  
Switching voltage (V)  
Switching current (A)  
Ambient temperature (°C)  
Note The
 
“maximum coil voltage” is the maximum  
voltage that can be applied to the Relay coil.  
G6RL-1(A)(4)  
G6RL-1(A)(4)-(ASI)-(PL)  
●
Ambient Temperature vs. Must  
Operate or Must Release Voltage  
120  
●
Shock Malfunction  
Y
9
8
0  
Sample: G6RL 24 VDC  
N
u
m
b
er of relays: 5 pcs  
M
u
st operate
v
oltage  
M
u
st release
v
oltage  
NO contact  
G
6
R
L
100  
8
0  
X
9
8
0  
Z
9
8
0  
max.  
X
min.  
Sample:  
Number of Relays:
 
5 pcs  
Test Conditions:  
G6RL-1 24
 
VDC  
NC contact  
The value at which malfunction  
occurred was measured after  
applying shock to the test piece  
3 times each in 6 directions  
along 3 axes.  
60  
294  
9
8  
9
8
0  
Z’  
40  
X’  
max.  
X
Standard value:  
200m/s

2

(NO)  
min.  
50m/s

2

(NC)  
20  
0
Shock direction  
9
8
0  
Unit: m/s

2  

X’  
X
Y
Y’  
Z
Z’  
−
40  
−
20  
0
20  
40  
60  
8
0 100  
Y’  
Am
b
ient temperat
u
re (°C)  
■
Dimensions  
(Unit: mm)  
G6RL-1A  
G6RL-1A-ASI  
G6RL-1A4-ASI  
PCB Mounting Holes  
Terminal Arrangement/Internal  
Connections  
(Bottom View)  
(Bottom View)  
(2.9)  
5
0.1  
18.9 0.1  
10.0 max.  
28.5 max.  
(1.7)  
1
5
2
3
Four, 1.3
 
0.1 dia. holes  
0.24  
0.4  
0.8  
0.4  
0.8  
(Indicates average  
dimensions.)  
G6RL-1  
G6RL-1-ASI  
G6RL-14-ASI  
PCB Mounting Holes  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
(Bottom View)  
(1.5)  
18.9 0.1  
3.2 0.1  
3.2 0.1  
(1.7)  
10.0 max.  
28.5 max.  
1
5
2
4
3
Five, 1.3
 
0.1 dia. holes  
(Indicates average  
dimensions.)  
0.8  
0.4  
0.24  
0.4  
0.4  
0.8  
3

G6RL  
■
Approved Standards  
PCB Power Relay  
The approval ratings for overseas models are different from the performance values determined individually. Confirm the values before  
use.  
●
UL/C-UL Recognized:  
(File No. E41643)UL508/CSA22.2 No.14  
Models  
G6RL-1A  
Contact from  
Coil ratings  
Contact ratings  
Number of test operations  
SPST-NO (1a)  
SPDT (1c)  
10 A, 250 VAC (NO) (Resistive) 85°C  
8 A, 250 VAC (Resistive) 85°C  
5 A, 30 VDC (Resistive) 85°C  
G6RL-1  
3 to 48 VAC  
6,000  
G6RL-1A(4)-ASI  
G6RL-1(4)-ASI  
SPST-NO (1a)  
SPDT (1c)  
Note.CSA standards: Certified by C-UL.  
●
EN/IEC, VDE Certified:  
(EN61810-1) (Certificate No. C266)  
Models  
G6RL-1A-(ASI)  
Contact from  
SPST-NO (1a)  
Coil ratings  
Contact ratings  
10 A, 250 VAC (NO) 85°C  
8 A, 250 VAC
 
85°C  
Number of test operations  
10,000  
30,000  
50,000  
3, 5, 6, 12, 24, 48 VDC  
3, 5, 6, 12, 24, 48 VDC  
G6RL-1-(ASI)  
G6RL-1A4-ASI  
G6RL-14-ASI  
SPDT (1c)  
5 A , 30 VDC
 
85°C  
10 A, 250 VAC (NO) 85°C  
8 A, 250 VAC
 
85°C  
5 A, 30 VDC
 
85°C  
SPST-NO (1a)  
SPDT (1c)  
10,000  
●
EN/IEC, VDE Certified:  
(EN 60947-5-1) (Certificate No. C266)  
Models  
Contact ratings  
Number of test operations  
AC15 (NO)  
DC13  
AC240, 3
 
A, cos
ϕ
0.3, Room temperaure  
G6RL-1(A)(4)  
DC125, 0.22A,
 
165ms, Room temperaure  
DC250, 0.1A,
 
150ms, Room temperaure  
AC240, 3
 
A, cos
ϕ
0.3, Room temperaure  
DC125, 0.22A,
 
165ms, Room temperaure  
DC250, 0.1A,
 
150ms, Room temperaure  
AC240, 3
 
A, cos
ϕ
0.3, Room temperaure  
DC125, 0.22A,
 
165ms, Room temperaure  
G
6
R
L
DC13  
AC15  
6,000  
G6RL-1(A)-ASI  
G6RL-1(A)4-ASI  
DC13  
DC13  
AC15  
DC13  
●
EN/IEC, VDE Certified:  
(EN60947-4-1) (Certificate No. C266)  
Models  
Contact ratings  
Number of test operations  
AC1 AC250V  
AC3 AC250V  
ꢀ
8 A
 
85°C  
2 A
 
85°C  
5 A
 
85°C  
2 A
 
85°C  
ꢀ
G6RL-1(A)  
G6RL-1(A)-ASI  
6,000  
DC1 DC24V  
DC3 DC24V  
ꢀ
ꢀ
●
EN/IEC, VDE Certified:  
(EN60730-1) (Certificate No. 40021033)  
Models  
Coil ratings  
Contact ratings  
Number of test operations  
2 (2) A
 
AC250V  
65°C  
65°C  
85°C  
65°C  
65°C  
85°C  
G6RL-1(A)  
6 (4) A (NC) AC250V  
8 (4) A (NO) AC250V  
2 (2) A
 
AC250V  
3, 5, 6, 12, 24, 48 VDC  
100,000  
G6RL-1(A)-ASI  
6 (4) A (NC) AC250V  
8 (4) A (NO) AC250V  
●
EN/IEC  
Basic Requirements of Machinery Directive/Low-voltage Directive  
Models  
CE Marking  
Applicable Safety Category  
Applicable Standard No.  
Application Standard No.  
G6RL  
−
1
EN61810-1  
−
Note. Basic requirements of EMC directives (EMI standard No., EMS standard No., Certification Body, File No., Applicable time) … not applicable.  
Creepage distance  
10 mm  
10 mm  
IIIa  
Clearance distance  
Insulation material group  
Rated Insulation Voltage  
Pollution degree  
250 V  
3
250 V  
III  
2
400 V  
II  
Rated voltage system  
Overvoltage category  
Tracking Index of relay base  
Flammability class according to UL94  
Ball pressure test (IEC 60695-10-2)  
PTI 250 V min. (housing parts)  
V-0  
170°C  
4

G6RL  
■
Precautions  
PCB Power Relay  
●
Please refer to “PCB Relays Common Precautions” for correct use.  
Correct Use  
• The G6RL are net intended to be used in automotive  
applications (including two wheel vehicles).  
• If the product is used in the following applications, consult your  
OMRON sales representative to check the necessary items  
according to the specification sheets. Also make sure the  
product is used within the specified ratings and performance  
ranges with an ample margin and implement safety measures,  
such as designing a safety circuit, to minimize danger should  
the product fail.  
a. Outdoor use, uses involving potential chemical  
contamination or electrical interference.  
b. Nuclear energy control systems, combustion systems,  
railroad systems, aviation systems, medical equipment,  
safety equipment, and equipment that could present a risk  
to human life or body.  
c. Equipment requiring a high level of reliability, such as gas,  
water, or electrical supply systems.  
G
6
R
L
Please check each region’s Terms & Conditions by region website.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Regional Contact  
Americas  
Europe  
Asia-Pacific  
China  
Korea  
Japan  
© OMRO
N
Corporation 2007-2020
 
All Rights Reserved.  
In the interest of product improvement, specifications are subject to change without notice.  
Cat. No.
K133-E1-09  
0620(0207
)(O)  
5