Omron-Electronics-G6RN-1A-AP4-DC24
| Part # | Omron-Electronics-G6RN-1A-AP4-DC24 |
| Download | Omron-Electronics-G6RN-1A-AP4-DC24 |
G6RN
Miniature Power Relay for
Switching 8 A
PCB Power Relay
• Low-profile height of 15 mm (approx. 60% the height of the Omron
G2R model).
• Capable of switching with 8 A at 250 VAC despite its small size.
• High sensitivity with 220mW power consumption.
• Offers high insulation with insulation distance of 8 mm and impulse
withstand voltage of 10kV between coil and contacts.
• Satisfies ambient operating temperature requirement of 85°C.
• Standard model conforms to VDE standards.
RoHS Compliant
■
Application Examples
■
Model Number Legend
G6RN-
@
@
• Control
equipments
— —
G
6
1 2
■
Characteristics
1. Number
of Poles
2. Contact
Form
R
N
1: 1-pole
None: SPDT (1c)
A: SPST-NO (1a)
Contact resistance *1
Operate time
Release time
100 m
Ω
max.
15 ms max.
5 ms max.
Insulation resistance *2
1,000 M
Between
Ω
min.
■
Ordering Information
coil and
4,000 VAC, 50/60 Hz for 1 min
Enclosure
rating
Rated coil
voltage
5, 6, 12 VDC
24 VDC
5, 6, 12 VDC
24 VDC
Minimun
packing unit
contacts
Between
contacts of
the same
polarity
Classification
Contact form
Terminal shape
Model
G6RN-1A
G6RN-1
Dielectric
strength
SPST-NO (1a)
SPDT (1c)
1,000 VAC, 50/60 Hz for 1 min
PCB
terminals
Standard
Fully sealed
20 pcs/tube
Impulse withstand
voltage (between coil
and contacts)
10,000 V (1.2 x 50
μ
s)
Note. When ordering, add the rated coil voltage to the model number.
Example: G6RN-1A DC5
Between
coil and
contacts
Insulation
distance
Clearance: 8 mm,
Creepage: 8 mm
Rated coil voltage
However, the notation
of the coil voltage
on the product case will be marked as
@@
VDC.
10 to 55 to 10 Hz, 0.75 mm
Destruction
single amplitude
(1.5 mm double amplitude)
10 to 55 to 10 Hz
NO: 0.75 mm single amplitude
■
Ratings
Vibration
resistance
●
Coil
Malfunction
(1.5 mm double amplitude)
NC: 0.4 mm single amplitude
(0.8 mm double amplitude)
Must operate
Must release
Max.
voltage
(V)
Item
Rated
current
(mA)
Coil
resistance
(
Ω
)
Power
consumption
(mW)
voltage
(V)
voltage
(V)
Destruction
1,000 m/s
2
Shock
resistance
NO: 100 m/s
2
NC:: 50 m/s
2
10,000,000 operations min.
(at 36,000 operations/hr)
50,000 operations min.
(8 A at 250 VAC, resistive load)
50,000 operations min.
(5 A at 30 VDC, resistive load)
Rated voltage
5 VDC
% of rated voltage
Malfunction
43.9
36.6
18.3
9.2
114
164
655
6 VDC
12 VDC
24 VDC
150%
(at 23°C)
Mechanical
70% max.
10% min.
Approx. 220
2,620
Durability
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
Electrical *3
*2.
*3.
The operating characteristics are measured at a coil temperature of 23°C.
The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
(at 360 operations/hr under
rated load)
Failure rate (P level)
(reference value) *4
Ambient operating
temperature
Ambient operating
humidity
●
Contacts
Load
Item
Contact type
10 mA at 5 VDC
-40 C
to 85
C (with no icing or
°
°
Resistive load
condensation)
Single
5% to 85%
Ag-Alloy + gold plating
(Cd free)
8 A at 250 VAC
5 A at 30 VDC
Contact material
Rated load
Weight
Approx. 9 g
Note. The
data given above are initial values.
*1.
Measurement conditions: 5 VDC, 1 A, voltage drop
method.
Rated carry
current
Max. switching
voltage
Max. switching
current
8 A
*2.
Measurement conditions: The insulation resistance
was measured with a 500 VDC megohmmeter at the
same locations as the dielectric strength was
measured.
250 VAC, 30 VDC
8 A
*3.
*4.
Test conditions: With diode
This value was measured at a switching frequency of
120 operations/min.
1
G6RN
PCB Power Relay
■
Engineering Data
●
Maximum Switching Capacity
●
Durability
●
Ambient Temperature vs.
Maximum Coil Voltage
100
200
250 VAC resistive load
30 VDC resistive load
50
30
50
30
180
AC resistive load
DC resistive load
160
150
140
130
120
110
100
10
8
5
3
10
1
5
3
0.5
0.3
80
0
0.1
1
0
3
5
10
30 50
100
250 500
0
2
4
6
8
10
-40 2023
30
40
50
60
70
80
90 100
Switching Voltage (V)
Switching Current (A)
Ambient
T
e
mperature (°C)
Note. The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
●
Ambient Temperature vs.
●
Shock Malfunction
Maximum Coil Voltage
G6RN-1
Y
100
1,000
Sample: G6RN-1 24 VDC
Number of Relays: 5 pcs
Must operate voltage
Must release voltage
Sample:
contact A
G6RN-1 12 VDC
Number of Relays:
5 pcs
Test conditions: The value at which
malfunction occurred was measured
after applying shock to the test piece 3
times each in 6 directions along 3 axes.
Standard value: 100m/s
2
at contact A,
50m/s
2
at contact B
G
6
R
N
80
60
40
20
X
1,000
Z
max.
X
min.
1,000
88.2
contact B
1,000
X’
1,000
Z’
max.
X
min.
Shock direction
X
X’
1,000
Y’
Unit: m/s
2
Y
Z
0
-40
Z’
-20
0
20
40
60
80 100
Y’
Ambient
T
e
mperature (°C)
■
Dimensions
PCB Mounting Holes
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
G6RN-1
0.5
10
0.5
28.5
Five, 1.3-dia. holes
7.62
(1.19)
1
5
2
0.5
15
3.5
0.1
0.5
4
3
(1.19)
0.1
3.2
7.62
19
(1.5)
0.1
(No coil polarity)
0.1
3.2
3.2
(1.6)
19
3.2
PCB Mounting Holes
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
G6RN-1A
0.5
10
0.5
28.5
Four, 1.3-dia. holes
(1.19)
1
2
0.5
15
3.5
0.1
7.62
0.5
5
3
(1.19)
0.1
19
7.62
19
5.1
(No coil polarity)
0.1
(2.8)
(1.6)
5.1
2
G6RN
PCB Power Relay
■
Approved Standards
●
The rated values approved by each of the safety standards may be different from the performance characteristics individually defined
in this catalog.
UL Recognized
CSA Certified
(File No. E41515)
(File No. 31928)
Number of
poles
Number of test
operations
Model
G6RN-1
Coil ratings
Contact ratings
8 A, 250 VAC 85°C
8 A, 30 VDC 85°C
1
5 to 24 VDC
6,000
EN/TÜV Certified
(Certificate No. 6135)
Number of
poles
Approved switching
operations
Model
Coil ratings
Contact ratings
G6RN-1
G6RN-1A
8 A, 250 VAC (Resistive)
85°C
1
5, 6, 12, 24 VDC
10,000
Creepage distance
8 mm
8 mm
IIIa
Clearance distance
Insulation material group
Rated Insulation voltage
Pollution degree
250 V
2
Rated voltage system
Overvoltage category
Tracking Index of relay base
250 V
III
PTI 250 V min. (housing parts)
Flammability class according to UL94
Ball pressure test (IEC 60695-10-2)
V-0
G
6
R
N
160°C
■
Precautions
●
Please refer to “PCB Relays Common Precautions” for correct use.
•
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
•
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Cat. No. J182-E1-04
1116(0207)(O)
3
