Omron-Electronics-G6W-1F-DC9
| Part # | Omron-Electronics-G6W-1F-DC9 |
| Download | Omron-Electronics-G6W-1F-DC9 |
DISCONTINUED
High-frequency Relay
G6W
Surface-mountable 5 GHz Band Miniature
SPDT High-frequency Relay
• Superior high-frequency characteristics, such as an
isolation of 35 dB min., insertion loss of 0.5 dB max., and
V
.
S.W.R. of 1.7 max. at 5 GHz (50
Ω
).
• High-frequency characteristics obtained by adopting
tri-plate micro strip line design.
• Small size at 20 x 9.4 x 8.9 mm (L x W x H).
•
Y
–
shape terminal structure and reverse contact option
simplifies wiring to PCBs.
• RoHS Compliant.
Ordering Information
Classification
Non latching
Single-coil
latching
Dual-coil
latching
SPDT
Fully sealed
Through-hole terminal
Surface-mount terminal
Y
–
shape terminal
Y
–
shape terminal
G6W-1P
G6W-1F
G6WU-1P
G6WK-1P
G6WK-1F
G6WU-1F
Note:
W
hen ordering, add the rated coil
v
oltage to the model n
u
m
b
er.
Example: G6
W
-1P DC12
Rated coil
v
oltage
Model Number Le
g
end:
G6W
–
–
1
2
3
4
5
1. Relay
function
N
one:
N
on-latching
3. Terminal
shape
5. Contact
Arran
g
ement
F:
P:
S
u
rface-mo
u
nt terminals
PCB thro
u
gh-hole terminals
N
one: Standard
contact arrangement
U:
K:
Single-coil latching
R:
Re
v
erse contact arrangement
(A
v
aila
b
le only for
N
on-Latching
v
ersions)
D
u
al-coil latching
4. Terminal
Structure
2. Contact
form
1: SPDT
N
one: Y-shape
terminal
(standard)
■
Typical Applications
•
Mobile phone base station (W-CDMA, UMTS, CDMA-2000, PCS)
•
Wireless LAN and TV transmitters
•
T
e
st and Measurement devices
•
Signal Generators
High-frequency Relay
G6W
327
DISCONTINUED
Specifications
■
Contact Ratings
Load type
Resistive load
Contact material
Rated load
Au clad Cu alloy
10 mA at 30 VAC; 10 mA at 30 VDC
2.5 GHz, 50
Ω,
10 W (See note 2)
0.5 A
Rated carry current
Max. switching voltage
Max. switching current
30 VDC, 30 VAC
0.5 A
■
High-frequency Characteristics
Frequency
2.0 GHz
65 dB min.
0.2 dB max.
2.5 GHz
60 dB min.
5.0 GHz
Isolation
35 dB min.
Insertion loss
V
.
S.W.R.
0.5 dB max.
1.7 max.
1.2 max.
Max. carry power
Max. switching power
20 W (See note 2)
10 W (See note 2)
Note: 1.
The above values are initial values.
2.
These values are for a load with
V
.
S.W.R.
≤
1.2 at an impedance of 50
Ω
.
■
Coil Ratings
Non-latching Relays (G6W-1F, G6W-1P)
Rated voltage
3 VDC
66.7 mA
45
Ω
4.5 VDC
44.4 mA
101
Ω
9 VDC
22.2 mA
405
Ω
12 VDC
16.7 mA
720
Ω
24 VDC
8.3 mA
2,880
Ω
Rated current
Coil resistance
Must operate voltage
Must release voltage
Maximum voltage
Power consumption
80% of max. of rated voltage
10% min. of rated voltage
150% of rated voltage
Approx. 200 mW
Single-coil Latching Relays (G6WU-1F, G6WU-1P)
Rated voltage
9 VDC
12 VDC
Rated current
22.2 mA
16.7 mA
Coil resistance
Must set voltage
Must reset voltage
Maximum voltage
Power consumption
405
Ω
720
Ω
80% max. of rated voltage
80% max of rated voltage
150% of rated voltage
Approx. 200 mW
Dual-coil Latching Relays (G6WK-1F, G6WK-1P)
Rated voltage
3 VDC
120 mA
25
Ω
4.5 VDC
80 mA
56
Ω
9 VDC
12 VDC
30 mA
400
Ω
24 VDC
15 mA
Rated current
40 mA
Coil resistance
Must set voltage
Must reset voltage
Maximum voltage
Power consumption
225
Ω
1,600
Ω
80% max. of rated voltage
80% max. of rated voltage
150% of rated voltage
Approx. 360 mW
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23
°
C with a tolerance of
±
10%.
2.
The operating characteristics are measured at a coil temperature of 23
°
C.
3.
The maximum voltage is the highest voltage that can be imposed on the relay coil.
4.
The voltage measurements for operate/release and set/reset are the values obtained for instantaneous changes in the voltage.
(Rectangular wave).
328
High-frequency Relay
G6W
DISCONTINUED
■
Characteristics
Item
Non-latching
G6W-1F, G6W-1P
100 m
Ω
max.
Single-coil latching
G6WU-1
F
,
G
6WU-1P
Dual-coil latching
G6WK-1
F
,
G
6WK-1P
Contact resistance (See note 2)
Operate (set) time (See note 3)
Release (reset) time (See note 3)
Minimum set/reset signal width
Insulation resistance (See note 4)
10 ms max. (Approx. 3.5 ms)
10 ms max. (Approx. 2.5 ms)
10 ms max. (Approx. 2.5 ms)
—–
12 ms
1,000 M
Ω
min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1 min
Dielectric strength
Coil and contacts
Coil and ground,
contacts and ground
Contact of same
polarity
500 VAC, 50/60 Hz for 1 min
Vibration resistance
Shock resistance
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
10 to 55 Hz, 1.5-mm double amplitude
10 to 55 Hz, 2-mm double amplitude
1,000 m/s
2
500 m/s
2
Endurance
1,000,000 operations min. (at 36,000 operations/hour)
300,000 operations min. (with a rated load at 1,800 operations/hour)
100,000 operations min. (2.5GHz, 50
Ω
, 10 W)
Ambient temperature
Ambient humidity
Weight
Operating: -40
°
C to 70
°
C (with no icing or condensation)
Operating: 5% to 85%
Approx. 3 g
Note: 1.
The above values are initial values.
2.
The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
3.
Values in parentheses are typical values.
4.
The insulation resistance was measured with a 500-VDC Megger
T
e
ster applied to the same parts as those used for checking the dielectric strength.
Engineering Data
Ambient Temperature vs.
Maximum Voltage
Ambient Temperature vs.
Must Set or Must Reset Voltage
Shock Malfunction
250
Y
100
Max. estimated value
1,000
Energized
90
80
70
60
50
40
30
20
max.
avg.
max.
avg.
min.
min.
800
600
400
200
200
X
Z
Not
energized
1,000
1,000
150
100
200
400
600
800
1,000
Z’
1,000
X’
Shock direction
50
0
X
X’
Unit: m/s
2
Sample: G6WK-1P
4.5 VDC
Number of Relays: 10
Y
10
0
Must set voltage
Must reset voltage
1,000
Z
Y’
Z’
−
40
−
20
0
20
40
60
80 100
−
60
−
40
−
20
0
20
40
60
80 100
Y’
Ambient temperature (
°
C)
Ambient temperature (
°
C)
Conditions: Shock is applied in
±
X,
±
Y
,
a
nd
±
Z directions three times each with and
without energizing the relays to check the
number of contact malfunctions.
Note:
“Maximum voltage” is the maximum
voltage that can be applied to the relay
coil.
High-frequency Relay
G6W
329
DISCONTINUED
Electrical Endurance, DC Load:
Must Set and Must Reset Voltage
(See notes 1 and 2)
Electrical Endurance, AC Load:
Must Set and Must ResetVoltage
(See notes 1 and 2)
100
100
80
80
Must set voltage
max.
max.
Must set voltage
60
max.
max.
60
min.
min.
min.
min.
Must reset voltage
40
Must reset voltage
40
Sample: G6WU-1P
9 VDC
Number of Relays: 5
Sample: G6WU-1P
9 VDC
Number of Relays: 5
20
20
Test conditions: 10-mA resistive load at
30-VDC with an operation rate of 50%.
Switching frequency: 1,800 operations/h
Test conditions: 10-mA resistive load at
30-VAC with an operation rate of 50%.
Switching frequency: 1,800 operations/h
0
0
0.001 0.01
0.1
1
10
100 1,000
0.001 0.01
0.1
1
10
100 1,000
Operating frequency (
×
10
3
operations)
Operating frequency (
×
10
3
operations)
Electrical Endurance, DC Load:
Contact Resistance
(See notes 1 and 2)
1,000
Electrical Endurance, AC Load:
Contact Resistance
(See notes 1 and 2)
1,000
Sample: G6WU-1P
9 VDC
NO contact
Sample: G6WU-1P
9 VDC
NO contact
Number of Relays: 5
Test conditions:
Number of Relays: 5
NC contact
Test conditions:
NC contact
10-mA resistive load at 30-VAC
Switching frequency: 1,800 operations/h
500
300
500
300
10-mA resistive load at 30-VDC
Switching frequency: 1,800 operations/h
100
100
50
30
50
30
Contact resistance
Contact resistance
max.
max.
max.
min.
min.
max.
min.
min.
10
10
0.001 0.01
0.1
1
10
100 1,000
0.001 0.01
0.1
1
10
100 1,000
Operating frequency (
×
10
3
operations)
Operating frequency (
×
10
3
operations)
External Magnetic Interference
(Average value)
(Average value)
(Average value)
N
+30
+20
+30
+20
+30
+20
Sample: G6WK-1P 4.5 VDC
Number of Relays: 5
Sample: G6WK-1P 4.5 VDC
Number of Relays: 5
Sample: G6WK-1P 4.5 VDC
Number of Relays: 5
S
N
S
N
S
+10
0
+10
0
+10
0
−
10
−
10
−
10
−
20
−
30
−
20
−
30
−
20
−
30
Must set voltage
Must reset voltage
Must set voltage
Must reset voltage
Must set voltage
Must reset voltage
−
1,200
−
800
−
400
0
400
800 1,200
−
1,200
−
800
−
400
0
400
800 1,200
−
1,200
−
800
−
400
0
400
800 1,200
External magnetic field (A/m)
External magnetic field (A/m)
External magnetic field (A/m)
Note: 1.
The tests were conducted at an ambient temperature of 23
°
C
2.
The contact resistance data are periodically measured reference values and are not values from monitoring each operation.
Contact resistance values will vary according to the switching frequency and operating environment. Therefore, be sure to check
the operation under the actual operating conditions before use.
330
High-frequency Relay
G6W
DISCONTINUED
Isolation
(See notes 1 and 2)
Insertion Loss
(See notes 1 and 2)
V.S.W.R. / Return Loss
(See notes 1 and 2)
[Average (Initial value)]
[Average (Initial value)]
[A
v
erage (Initial
v
al
u
e)]
0
0
0
2.4
2.2
N
.O.
N
.C.
10
20
0.2
0.4
0.6
Ret
u
rn loss
20
30
40
50
2.0
1.
8
1.6
1.4
40
60
80
V
.S.
W
.R.
0.8
1.0
100
120
60
70
1.2
1.0
N.O.
N.C.
N.O.
N.C.
0
1,000 2,000 3,000 4,000 5,000
6,000
Frequency (MHz)
0
1,000 2,000 3,000 4,000 5,000
6,000
Frequency (MHz)
0
1,000 2,000 3,000 4,000 5,000
6,000
Fre
qu
ency (MHz)
Must Set and Must Reset
Time Distribution (see note 1).
Must Set and Must Reset
Bounce Time Distribution (see note 1).
20
30
Sample:
G6WK-1P 4.5 VDC
Number of Relays: 20
Sample:
G6WK-1P 4.5 VDC
Number of Relays:
20
Must set time
Must reset time
Must set bounce time
Must reset bounce time
25
20
15
10
5
15
10
5
0
0.5
1.0
1.5
2.0
2.5
3.0 3.5
0
0.5
1.0
1.5
2.0
2.5
3.0
Time (ms)
Time (ms)
Note: 1.
The tests were conducted at an ambient temperature of 23
°
C.
2.
High-frequency characteristics depend upon the PCB to which the relay is mounted. Always check these characteristics, including en-
durance (life expectancy) in the actual application before use.
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Terminal Arran
g
ement/
Internal Connections
(Top View)
Mountin
g
Pads
G6W-1F
G6WU-1F
(Top View)
Tolerance: 0.1
mm
G6W-1F
2.54 2.54 2.54 2.54
5.0
8
Orientation mark
3.2
17
15 14 13
11
7
1
8
10
+
−
2.7 1.
8
5.0
8
9.4
20
8
1
2
3
5
6
1.1
20
9.4
5.9
3
2.
8
1.1
8
.6
G6WU-1F
Orientation mark
Thro
u
gh-hole
20.4
9.2
17
15 14 13
11
7
1
8
10
S
R
+
−
T
w
el
v
e, 0.6
15.24
Three,
0.4
0.2
0.2
−
+
5.0
8
22.2
11.6
20
8
Note: 1.
Tolerance: 0.3
mm
u
nless specified.
2.
The coplanarity of the terminals is 0.1 mm max.
1
2
3
5
6
High-frequency Relay
G6W
331
DISCONTINUED
Mountin
g
Holes
(Bottom View)
Tolerance: 0.1
mm
Terminal Arran
g
ement/
Internal Connections
(Bottom View)
G6W-1P
G6WU-1P
G6W-1P
Orientation mark
2.54 2.54 2.54 2.54 2.54 2.54
1.6-dia.
0.
8
-dia.
0.
8
-dia.
1.6-dia.
1
2
3
5
6
7
20
8
2.7
1.
8
5.0
8
7.62
+
−
1
8
10
T
w
el
v
e, 1-dia.
17
15 14
13
11
20
9.4
T
w
el
v
e, 1.
8
-dia.
3
5.9
8
.6
Thro
u
gh-hole
G6WU-1P
Orientation mark
19
0.
8
-dia.
1.6-dia.
8
.9
1
2
3
5
6
7
20
8
S
R
+
−
T
w
el
v
e,
0.6
5.0
8
10.16
15.24
19
Three,
0.4
5.0
8
−
+
7.6
1
8
10
17
15 14
13
11
Note:
Tolerance: 0.3
mm
u
nless specified.
Mountin
g
Pads
Terminal Arran
g
ement/
Internal Connections
(Top View)
G6WK-1F
(Top View)
Tolerance: 0.1
mm
G6WK-1F
2.54 2.54 2.54 2.54
5.0
8
Orientation mark
3.2
17 16
1514
13
+
11
7
1
8
10
−
R
+
−
S
2.7 1.
8
5.0
8
9.4
20
9.4
20
8
1
2
3
5
6
1.1
9.2
5.9
3
2.
8
1.1
8
.6
Thro
u
gh-
hole
20.4
Thirteen, 0.6
15.24
Three,
0.4
0.2
0.2
5.0
8
22.2
11.6
Note: 1.
Tolerance: 0.3
mm
u
nless specified.
2.
The coplanarity of the terminals is 0.1 mm max.
Mountin
g
Holes
Terminal Arran
g
ement/
Internal Connections
(Bottom View)
G6WK-1P
(Bottom View)
Tolerance: 0.1
mm
G6WK-1P
Orientation mark
2.54 2.54 2.54 2.54 2.54 2.54
1.6-dia.
0.
8
-dia.
0.
8
-dia.
1.6-dia.
1
2
3
5
6
7
20
8
+
−
S
2.7
1.
8
5.0
8
7.62
20
9.4
+
−
R
1
8
10
Thirteen, 1-dia.
17 16
15 14
13
11
Thirteen, 1.
8
-dia.
8
.9
3
5.9
8
.6
Thro
u
gh-hole
19
0.
8
-dia.
1.6-dia.
Thirteen,
0.6
5.0
8
10.16
15.24
19
Three,
0.4
5.0
8
7.6
Note:
Tolerance: 0.3
mm
u
nless specified.
332
High-frequency Relay
G6W
DISCONTINUED
Recommended Soldering Method
■
Temperature Profile According to IRS Method
When performing reflow-soldering, check the profile on an actual device
after setting the temperature condition so that the temperatures at the
relay terminals and the upper surface of the case do not exceed the
limits specified in the following table.
The thickness of cream solder to be applied should be within a range
between 150 and 200
μ
m on OMRON’s recommended PCB pattern.
Correct Soldering
Incorrect Soldering
Relay
Excessive
amount of
solder
Insufficient
amount of
solder
T4
T3
Terminal
Solder
PCB
Land
T2
T1
Visually check that the Relay is properly soldered.
Bottom Ground Soldering Conditions
To
s
older the bottom ground, manually solder separately from the
terminals according to the following conditions.
•
Soldering iron: 50 W
•
Iron temperature: 380
°
C to 400
°
C
•
Soldering time: 10 s max.
t
2
t
1
Note:
The above conditions are for a PCB with OMRON’s recommended
patterns and hole perforations. The conditions will depend on the
PCB being used. Therefore, it is recommended to double-check
the suitability under actual PCB conditions.
Preheating
Soldering
Time (s)
Item
Preheating
Soldering
(T3, t
2
)
Peak value
(T4)
Soldering
Measuring
position
(T1 to T2, t
1
)
Soldering temperature: Approx. 250
used.)
°
C (At 260
°
C if the DWS method is
Terminal
150
°
C to 180
°
C, 230
°
C min.,
250
°
C max.
255
°
C max.
120 s max.
30 s max.
Soldering time: Approx. 5 s max. (approx. 2 s for the first time and
approx. 3 s for the second time if the DWS method is used.)
Upper surface
—
of case
—
Be sure to adjust the level of the molten solder so that the solder will not
overflow onto the PCB.
Precautions
Claw Securing Force During Automatic Insertion
■
Correct Use
During automatic insertion of Relays, make sure to set the securing force
of the claws to the following values so that the Relay characteristics will
be maintained.
Handling
Use the Relay as soon as possible after opening the moisture-proof
package. If the Relay is left for a long time after opening the moisture-
proof package, the appearance may suffer and seal failure may occur
after the solder mounting process.
T
o
s
tore the Relay after opening the
moisture-proof package, place it into the original package and sealed the
package with adhesive tape.
C
B
A
When washing the product after soldering the Relay to a PCB, use a
water-based solvent or alcohol-based solvent, and keep the solvent tem-
perature to less than 40
°
C. Do not put the Relay in a cold cleaning bath
immediately after soldering.
Direction A: 4.90 N max.
Direction B: 9.80 N max.
Direction C: 9.80 N max.
Dropping the Relay may cause damage to its functional capabilit
y
.
Never use the Relay if it is dropped.
Secure the claws to the area indicated by shading.
Do not attach them to the center area or to only part of the
Relay.
Protect the Relays from direct sunlight during operation, storage, and
transportation and keep the relays under normal temperature, humidit
y
,
and pressure.
Latching Relay Mounting
Coating
Make sure that the vibration or shock that is generated from other
devices, such as relays in operation, on the same panel and imposed on
the Latching Relay does not exceed the rated value, otherwise the Latch-
ing Relay that has been set may be reset or vice versa. The Latching
Relay is reset before shipping. If excessive vibration or shock is imposed,
however, the Latching Relay may be set accidentall
y
.
B
e sure to apply a
reset signal before use.
Do not use silicone coating to coat the Relay when it is mounted to
the PCB. Do not wash the PCB after the Relay is mounted using
detergent containing silicone. Otherwise, the detergent may remain
on the surface of the Rela
y
.
High-frequency Relay
G6W
333
DISCONTINUED
■
High-frequency Characteristics Measurement Method and Substrate to be Measured
High-frequency Characteristics for G6W are measured as shown below.
G6W-1
Vector network analyzer
(Manufacture:
Agilent
T
e
chnologies)
50- termination
resistances
HP8753D
Through-hole substrate
SMD-type substrate
Substrate: t-0.8 BT resin (Dielectric constant at 2 GHz: 3.37)
Substrate: t-0.8 BT resin (Dielectric constant at 2 GHz: 3.37)
1.5
1.4
1.5
0.5 0.5
0.4
0.5
0.4
1.8-dia.
4.5
Through-
hole
Through-hole
1.8
1.5
20
1.8 5.12
R0.6
6
1.5
45
°
45
°
1.5
0.5
0.5
R2.1
0.5
T
w
enty seven,
0.6-dia.,
through-hole
3
3
3
3
Thirty one, 0.6-dia.,
through-hole
8.6
30
8.6
15.24
Undersurface of relay
Undersurface of relay
Convex position
Convex position
Note:
T
o
o
btain high-frequency characteristics close to those specified in this datasheet, solder the convex point on the undersurface of the relay
to the ground pattern of the substrate.
Base plate for high-frequency characteristic compensation
Twenty four, 0.6-dia.,
through-hole
2
13.6
0.5
1.5 15
Note:
The above compensation plate is used to measure the loss by
the rela
y
.
The relay loss is determined by subtracting the data measured
for a compensation base plate from those for a high-frequency
characteristics measuring substrate mounted with a rela
y
.
334
High-frequency Relay
G6W
DISCONTINUED
MEMO
High-frequency Relay
G6W
DISCONTINUED
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To
c
onvert millimeters into inches, multiply by 0.03937.
T
o
c
onvert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
12/10
Specifications subject to change without notice
Printed in USA
Cat. No. X302-E-1
High-frequency Relay
G6W